PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Rapid assay of choline in foods using microwave hydrolysis and a choline biosensor.

A fast procedure for the determination of choline in food was developed by coupling a microwave hydrolysis procedure with an O(2)/choline oxidase-based electrochemical biosensor. Time and temperature were varied to select the best conditions for the microwave hydrolysis. Results have been compared with those found by the traditional method, constituted by hydrolysis at 70 degrees C followed by enzymatic-colorimetric assay. Data obtained by the biosensor method correlated well with the enzymatic-colorimetric assay (R(2) = 0.998). Microwave versus traditional hydrolysis gave a good correlation both with the colorimetric and with biosensor procedures with a relative error below 6%. The method is sensitive and selective enough to be used for a wide variety of food items reducing remarkably the analysis time.

Biosensing Techniques↗

(CdSe)ZnS quantum dots and organophosphorus hydrolase bioconjugate as biosensors for detection of paraoxon.

In this paper, we first report a novel biosensor for the detection of paraoxon based on (CdSe)ZnS core-shell quantum dots (QDs) and an organophosphorus hydrolase (OPH) bioconjugate. The OPH was coupled to (CdSe)ZnS core-shell QDs through electrostatic interaction between negatively charged QDs surfaces and the positively charged protein side chain and ending groups (-NH2). Circular dichroism (CD) spectroscopy showed no significant change in the secondary structure of OPH after the bioconjugation, which indicates that the activity of OPH was preserved. Detectable secondary structure changes were observed by CD spectroscopy when the OPH/QDs bioconjugate was exposed to organophosphorus compounds such as paraoxon. Photoluminescence (PL) spectroscopic study showed that the PL intensity of the OPH/QDs bioconjugate was quenched in the presence of paraoxon. The overall quenching percentage as a function of paraoxon concentration matched very well with the Michaelis-Menten equation. This result indicated that the quenching of PL intensity was caused by the conformational change in the enzyme, which is confirmed by CD measurements. The detection limit of paraoxon concentration using OPH/QDs bioconjugate was about 10(-8) M. Although increasing the OPH molar ratio in the bioconjugates will slightly increase the sensitivity of biosensor, no further increase of sensitivity was achieved when the molar ratio of OPH to QDs was greater than 20 because the surface of QDs was saturated by OPH. These properties make the OPH/QDs bioconjugate a promising biosensor for the detection of organophosphorus compounds.

Aryldialkylphosphatase↗

Using novel polysaccharide-silica hybrid material to construct an amperometric biosensor for hydrogen peroxide.

A new type of sol-gel organic-inorganic hybrid material was developed and used for the fabrication of an amperometric hydrogen peroxide biosensor. This material was prepared from natural chitosan and recently introduced completely water-soluble precursor, tetrakis(2-hydroxyethyl) orthosilicates (THEOS), by the sol-gel process without the addition of organic solvents and catalysts. The gelation time for the sol-gel transition and dynamic rheological properties of the resultant gel matrix could be modulated by the amount of added THEOS. The structure of the hybrid gel was made up of a network and spherical particles, as confirmed by SEM observation. By electrochemical experiments, it was found that such a hybrid gel matrix could retain the native biocatalytic activity of the entrapped horseradish peroxidase and provide a fast amperometric response to hydrogen peroxide. The linear range for the determination of hydrogen peroxide was found to be from 1.0 x 10(-6) to 2.5 x 10(-4) mol/L with a detection limit of 4.0 x 10(-7) mol/L. The apparent Michaelis-Menten constant was determined to be 2.198 mmol/L. To improve the analytical characteristics of the fabricated biosensor, the effects of applied potential and pH value on the steady-state current were studied. Under the optimized experimental conditions, the fabricated biosensor was found to have good analytical performance, reproducibility, and storage stability.

Biocompatible Materials↗

Evaluation of genotoxic and immunotoxic activities of potential glucose biosensor components: ferrocenes.

Three ferrocenes used in glucose biosensor construction were tested in the aspect of genotoxic and immunotoxic activities. All three ferrocenes were not mutagenic in the standard bacterial Ames test. Equally in the Sister Chromatid Exchanges test in human lymphocyte cultures, the genotoxic action of tested ferrocenes could be excluded. However, all three significantly decreased the rate of lymphocyte proliferation and especially diminished the numbers of B-lymphocytes and NK-cells after 72 hours of in vitro culture. Marked differences between the ferrocenes in their immunotoxic activities were noticed, and we were able to select those which would be relatively safe and those which should be avoided in further investigation of the glucose biosensor construction. Our results indicate the necessity to estimate immunotoxic effects as well as genotoxic effects, especially in biosensor components potentially used in vivo.

Biosensing Techniques↗

Glucose biosensors based on dendrimer monolayers.

The peculiarities of glucose biosensors based on different generation of dendrimers (G0, G1 and G4) have been studied by amperometry and QCM techniques. It is shown that stable glucose biosensor can be obtained with low generation of dendrimers. The sensor sensitivity, however considerable, increased with increasing number of generation of dendrimers. This can be due to the increased volume of the dendrimer interior as well as with increased number of binding sites for glucose oxidase (GOX). QCM experiments showed that immobilization of GOX resulted in formation of enzyme multilayers on a dendrimer surface. The enzyme turnover for this system (0.1-0.01 s(-1)) was lower then that for immobilization of GOX onto a supported lipid films by means of avidin-biotin technology (1.1 s(-1)). However, dendrimer based biosensors are more stable in comparison with sBLM based sensors and could be stored in a refrigerator in dry conditions over 15 days without substantial loss of sensitivity.

Journal Article↗

Biosensor development.

This article reviews the recent biosensor developments for medical applications, focusing on the various biological recognition elements used in biosensors and the systems transduction mechanisms. Available instruments utilizing biosensor technology are also examined from a commercial perspective.

Animals↗

High sensitivity microgravimetric biosensor for qualitative and quantitative diagnostic detection of polychlorinated dibenzo-p-dioxins.

A piezoelectric immunosensor system was developed for the rapid detection of polychlorinated dibenzo-p-dioxins (PCDDs). The system uses a competitive inhibition enzyme immunoassay (EIA) based on a mouse monoclonal antibody that is specific for 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and a conjugate of a dioxin-like competitor coupled to the enzyme horseradish peroxidase (HRP). The anti-dioxin antibody was deposited on a 10 MHz AT-cut quartz crystal resonator modified with a self-assembly monolayer of dithiobis-N-succinimidyl propionate. PCDDs at different concentrations in the range 0.001-10 ng mL-1 were mixed with a constant amount of HRP-conjugated competitor. The frequency responses due to the adsorption of the mixed samples on the biosensor surface were measured. The results show that 2,3,7,8-TCDD can be quantitatively detected with the developed immunosensor in the concentration range 0.01-1.3 ng mL-1. Cross-reactivities of the biosensor to various PCDD congeners were also investigated. The sensitivity and selectivity of the quartz crystal microbalance (QCM) biosensor is comparable to EIA and ELISA methods in the detection of polychlorinated dibenzo-p-dioxins. The developed QCM immunosensing system offers significant improvements in speed, sample throughout and cost for the qualitative and quantitative detection of PCDDs compared with GC-MS.

Journal Article↗

Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor.

A disposable lactate biosensor able to operate in flow injection analysis is described and characterized. The biosensing layer, obtained by glutaraldehyde co-crosslinking of lactate oxidase with bovine serum albumin, was cast on an underlying electropolymerized layer of overoxidized polypyrrole. The resulting biosensor was interference-free and showed a K'M value of 2.4 mmol l-1 and a maximum current density of 440 microA cm-2. When integrated in a flow injection analysis system, a sensitivity of 300 +/- 10 nA mmol-1 l, a linear response up to 1 mmol l-1 and detection limits in the low micromolar range were obtained. The introduction of a microdialysis membrane-based sampler reduced the sensitivity to 7.9 +/- 0.2 nA mmol-1 l and extended the linear range up to 50 mmol l-1 lactate. The anti-interference characteristics of the biosensor permitted lactate determination in untreated milk and diluted yoghurt samples.

Animals↗

Chemiluminescence biosensor chip based on a microreactor using carrier air flow for determination of uric acid in human serum.

A chemiluminescence biosensor on a chip coupled to a microfluidic system and a microreactor is described in this paper. The chemiluminescence biosensor measured 25 x 75 x 6.5 mm in dimension, and was readily produced in an analytical laboratory. The sol-gel method is introduced to co-immobilize horseradish peroxidase (HRP) and luminol in the microreactor, and to immobilize uricase in the enzymatic reactor. The main characteristic of the biosensor was to introduce air as the carrier flow instead of the more common solution carrier for the first time. The uric acid was determined by a chemiluminescent (CL) reaction between the hydrogen peroxide produced from the enzymatic reactor and luminol under the catalysis of HRP in the microreactor. The linear range of the uric acid concentration was 1 to 100 mg L(-1) and the detection limit was 0.1 mg L(-1) (3sigma).

Biosensing Techniques↗

Enzyme nanoparticles-based electronic biosensor.

A simple and effective method to prepare an enzyme electronic biosensor by immobilizing enzyme nanoparticles directly onto the gold electrode surface is described; prepared horseradish peroxidase nanoparticles have been successfully used to develop reagentless electronic biosensors for H2O2 detection without promoters and mediators and offer great potential to develop enzyme-based electronic biosensors.

Biosensing Techniques↗

The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: an electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity.

The apparent Michaelis constant, K(M), for glutamate oxidase (GluOx) immobilised on Pt electrodes increased systematically with enzyme loading. The effect was due, at least in part, to electrostatic repulsion between neighbouring oxidase molecules and the anionic substrate, glutamate (Glu). This understanding has allowed us to increase the Glu sensitivity of GluOx-based amperometric biosensors in the linear response region (100+/-11 nA cm(-2)microM(-1) at pH 7.4; SD, n=23) by incorporating a polycation (polyethyleneimine, PEI) to counterbalance the polyanionic protein. Differences in the behaviour of glucose biosensors of a similar configuration highlight a limitation of using glucose oxidase as a model enzyme in biosensor design.

Amino Acid Oxidoreductases↗

The advantage of using carbon nanotubes compared with edge plane pyrolytic graphite as an electrode material for oxidase-based biosensors.

Carbon nanotubes (CNTs) are promising materials for use in amperometric biosensors. The defect sites at their ends, and on their sidewalls, are considered to be edge plane-like defects and show high electrocatalytic activity toward several biological molecules. However, electrocatalytic activity toward H(2)O(2) has not been compared among bamboo-structured CNTs (BCNTs), which have many defect sites; hollow-structured CNTs (HCNTs), which have few defect sites; edge plane pyrolytic graphite (EPG); and traditional glassy carbon (GC). The advantages of using CNTs in electrodes for biosensors are still equivocal. To confirm the utility of CNTs, we analyzed the electrochemical performance of these four carbon electrodes. The slope of the calibration curve for H(2)O(2) at potentials of both +0.6 V and -0.1 V obtained with a BCNT paste electrode (BCNTPE) was more than 10 times greater than the slopes obtained with an HCNT paste electrode and a GC electrode, reflecting the BCNT's larger number of defect sites. Although the slope with the EPG electrode (EPGE) was about 40 times greater than that with BCNTPE at +0.6 V, the slopes with these two carbon electrodes were nearly equivalent at -0.1 V. EPGE demonstrated excessive electrochemical activity, detecting currents on the basis of consumption of oxygen and oxidation of ascorbic acid, even at -0.1 V. In contrast, BCNTPE could dominantly detect a cathodic current for H(2)O(2) at -0.1 V, even when interfering molecules were added. BCNTPE possesses appropriate electrochemical activity and is an effective electrode materials for developing interference-free oxidase-based biosensors operated by the application of an appropriate potential.

Animals↗

Continuous monitoring of extracellular glucose concentrations in the striatum of freely moving rats with an implanted glucose biosensor.

We have used a glucose oxidase-based sensor implanted in the striatum of freely moving rats to determine the concentration of extracellular glucose in two distinct ways. With a modification of the zero net flux method, in which different concentrations of glucose are infused through a dialysis probe glued to the biosensor, we calculated the concentration at which there was no change in glucose current by regression analysis; this gave a concentration of 0.351 +/- 0.016 mM. Calculating the concentration from the basal current and the in vitro calibration of the biosensor was not significantly different from this. The basal extracellular glucose concentration determined by either method remained constant over a period of several days. Infusion of 50 microM veratridine through the adjacent dialysis probe caused a steep decrease in glucose current as soon as the drug reached the brain in contrast to the delayed fall (7.5 min) seen with microdialysis in previous experiments from this laboratory. These results demonstrate that this biosensor provides a direct, real-time measure of the extracellular concentration of glucose.

Animals↗

Engineering a signal transduction mechanism for protein-based biosensors.

Hybridization-induced conformational changes have been successfully used in biosensors for the transduction of DNA-binding events into readily observable optical or electronic signals. Similar signal transduction has not, however, proven of equal utility in protein-based biosensors. The discrepancy arises because, unlike ssDNA, most proteins do not undergo significant conformational changes upon ligand binding. Here, we describe a solution to this problem. We show that an arbitrarily selected, normally well folded protein can be rationally engineered such that it undergoes ligand-induced folding. The engineered protein responds rapidly (milliseconds) and selectively to its target, and it couples recognition with the largest possible conformational change: folding. These traits suggest that ligand-induced folding could serve as an ideal signal-transduction mechanism. Consistent with this claim, we demonstrate a label-free optical biosensor based on the effect that is sufficiently selective to detect its target even in complex, contaminant-ridden samples such as blood serum.

Biosensing Techniques↗

Anomalous resonance in a nanomechanical biosensor.

The decrease in resonant frequency (-Deltaomega(r)) of a classical cantilever provides a sensitive measure of the mass of entities attached on its surface. This elementary phenomenon has been the basis of a new class of bio-nanomechanical devices as sensing components of integrated microsystems that can perform rapid, sensitive, and selective detection of biological and biochemical entities. Based on classical analysis, there is a widespread perception that smaller sensors are more sensitive (sensitivity approximately -0.5omega(r)/m(C), where m(C) is the mass of the cantilever), and this notion has motivated scaling of biosensors to nanoscale dimensions. In this work, we show that the response of a nanomechanical biosensor is far more complex than previously anticipated. Indeed, in contrast to classical microscale sensors, the resonant frequencies of the nanosensor may actually decrease or increase after attachment of protein molecules. We demonstrate theoretically and experimentally that the direction of the frequency change arises from a size-specific modification of diffusion and attachment kinetics of biomolecules on the cantilevers. This work may have broad impact on microscale and nanoscale biosensor design, especially when predicting the characteristics of bio-nanoelectromechanical sensors functionalized with biological capture molecules.

Adsorption↗

Galactosides in the rhizosphere: utilization by Sinorhizobium meliloti and development of a biosensor.

Identifying the types and distributions of organic substrates that support microbial activities around plant roots is essential for a full understanding of plant-microbe interactions and rhizosphere ecology. We have constructed a strain of the soil bacterium Sinorhizobium meliloti containing a gfp gene fused to the melA promoter which is induced on exposure to galactose and galactosides. We used the fusion strain as a biosensor to determine that galactosides are released from the seeds of several different legume species during germination and are also released from roots of alfalfa seedlings growing on artificial medium. Galactoside presence in seed wash and sterile root washes was confirmed by HPLC. Experiments examining microbial growth on alpha-galactosides in seed wash suggested that alpha-galactoside utilization could play an important role in supporting growth of S. meliloti near germinating seeds of alfalfa. When inoculated into microcosms containing legumes or grasses, the biosensor allowed us to visualize the localized presence of galactosides on and around roots in unsterilized soil, as well as the grazing of fluorescent bacteria by protozoa. Galactosides were present in patches around zones of lateral root initiation and around roots hairs, but not around root tips. Such biosensors can reveal intriguing aspects of the environment and the physiology of the free-living soil S. meliloti before and during the establishment of nodulation, and they provide a nondestructive, spatially explicit method for examining rhizosphere soil chemical composition.

Base Sequence↗

A biosensor assay for studying ligand-membrane receptor interactions: binding of antibodies and HIV-1 Env to chemokine receptors.

The HIV envelope (Env) protein mediates entry into cells by binding CD4 and an appropriate coreceptor, which triggers structural changes in Env that lead to fusion between the viral and cellular membranes. The major HIV-1 coreceptors are the seven transmembrane domain chemokine receptors CCR5 and CXCR4. The type of coreceptor used by a virus strain is an important determinant of viral tropism and pathogenesis, and virus-receptor interactions can be therapeutic targets. However, Envs from many virus strains interact with CXCR4 and CCR5 with low affinity such that direct study of this important interaction is difficult if not impossible using standard cell-surface binding techniques. We have developed an approach that makes it possible to study ligand binding to membrane proteins, including Env-coreceptor interactions, using an optical biosensor. CCR5, CXCR4, and other membrane proteins were incorporated into retrovirus particles, which were purified and attached to the biosensor surface. Binding of conformationally sensitive antibodies as well as Env to these receptors was readily detected. The equilibrium dissociation constant for the interaction between an Env derived from the prototype HIV-1 strain IIIB for CXCR4 was approximately 500 nM, explaining the difficulty in measuring this interaction using standard equilibrium binding techniques. Retroviral pseudotypes represent easily produced, stable, homogenous structures that can be used to present a wide array of single and multiple membrane-spanning proteins in a native lipid environment for biosensor studies, thus avoiding the need for detergent solubilization, purification, and reconstitution. The approach should have general applicability and can be used to correlate Env-receptor binding constants to viral tropism and pathogenesis.

Animals↗

Functionalized xenon as a biosensor.

The detection of biological molecules and their interactions is a significant component of modern biomedical research. In current biosensor technologies, simultaneous detection is limited to a small number of analytes by the spectral overlap of their signals. We have developed an NMR-based xenon biosensor that capitalizes on the enhanced signal-to-noise, spectral simplicity, and chemical-shift sensitivity of laser-polarized xenon to detect specific biomolecules at the level of tens of nanomoles. We present results using xenon "functionalized" by a biotin-modified supramolecular cage to detect biotin-avidin binding. This biosensor methodology can be extended to a multiplexing assay for multiple analytes.

Avidin↗