Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations.

Magnetic induction spectroscopy (MIS) aims at the contactless measurement of the passive electrical properties (PEP) sigma, epsilon, and mu of biological tissues via magnetic fields at multiple frequencies. Whereas previous publications focus on either the conductive or the magnetic aspect of inductive measurements, this article provides a synthesis of both concepts by discussing two different applications with the same measurement system: 1) monitoring of brain edema and 2) the estimation of hepatic iron stores in certain pathologies. We derived the equations to estimate the sensitivity of MIS as a function of the PEP of biological objects. The system requirements and possible systematic errors are analyzed for a MIS-channel using a planar gradiometer (PGRAD) as detector. We studied 4 important error sources: 1) moving conductors near the PGRAD; 2) thermal drifts of the PGRAD-parameters; 3) lateral displacements of the PGRAD; and 4) phase drifts in the receiver. All errors were compared with the desirable resolution. All errors affect the detected imaginary part (mainly related to sigma) of the measured complex field much less than the real part (mainly related to epsilon and mu). Hence, the presented technique renders possible the resolution of (patho-) physiological changes of the electrical conductivity when applying highly resolving hardware and elaborate signal processing. Changes of the magnetic permeability and permittivity in biological tissues are more complicated to deal with and may require chopping techniques, e.g., periodic movement of the object.

Animals↗

[Mechanisms of antigenic variation in influenza virus].

Human influenza A viruses evolve rapidly by antigenic shift and antigenic drift. Antigenic shift occurs by genetic reassortment between currently circulating human viruses and influenza viruses of other origin, by re-emergence of a previously circulating virus, and by invasion of animal influenza viruses. The segmental structure of the virus genome enables reassortment in multiply infected cells and also promotes multiple infection because it results in yielding noninfectious particles which randomly lack some genome segment and only become infectious by complementation with others. Antigenic drift is due to an accumulation of nonsynonymous substitutions in the genes encoding the HA and NA proteins. The limited nature of infection to the respiratory epithelium which is the border of the immune system enables the virus to reinfect and grow under the partial immune pressure which results in selecting and expanding antigenic mutants.

Animals↗

[Mechanisms of antigenic variation in influenza virus].

Human influenza A viruses evolve rapidly by antigenic shift and antigenic drift. Antigenic shift occurs by gentic reassortment between currently circulating human viruses and influenza viruses of other origin and by re-emergence of a previously circulating virus. The segmental structure of the virus genome enables reassortment in multiply infected cells and also promotes multiple infection because it results in yielding noninfectious particles which randomly lack some genome segment and only become infectious by complementation with others. Antigenic drift is due to an accumulation of nonsynonymous substitutions in the genes encoding the HA and NA proteins. The limited nature of infection to the respiratory epithelium which is the border of the immune system capacitates the virus to reinfect and grow under the partial immune pressure which results in selecting and expanding antigenic mutants.

Antigenic Variation↗

Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system.

INTRODUCTION: Non-invasive thermometry (NIT) is a valuable and probably indispensable tool for further development of radiofrequency (RF) hyperthermia. A hybridization of an MRI scanner with a hyperthermia system is necessary for a real-time NIT. The selection of the best thermographic method is difficult, because many parameters and attributes have to be considered. METHODS: In the hybrid system (Siemens Symphony/BSD-2000-3D) the standard methods for NIT were tested such as T1, diffusion (ADC: apparent diffusion coefficient) and proton-resonance-frequency shift (PFS) method. A series of three-dimensional datasets was acquired with different gradient-echo sequences, diffusion-weighted EPI spin-echo sequences and calculated MR-temperatures in the software platform AMIRA-HyperPlan. In particular for the PFS-method, corrective methods were developed and tested with respect to drift and other disturbances. Experiments were performed in phantoms and the results compared with direct temperature measurements. Then the procedures were transferred to clinical applications in patients with larger tumours of the lower extremity or the pelvis. RESULTS: Heating experiments and MR-thermography in a homogeneous cylindrical phantom give an excellent survey over the potentials of the methods. Under clinical conditions all these methods have difficulties due to motion, physiological changes, inhomogeneous composition and susceptibility variations in human tissues. The PFS-method is most stable in patients yielding reasonable MR temperature distributions and time curves for pelvic and lower extremity tumours over realistic treatment times of 60-90 min. Pooled data exist for rectal tumour recurrencies and soft tissue sarcomas. The fat tissue can be used for drift correction in these patients. T1 and diffusion-dependent methods appear less suitable for these patients. The standard methods have different sensitivities with respect to the various error sources. The advantages and pitfalls of every method are discussed with respect to the literature and illustrated by the phantom and patient measurements. CONCLUSIONS: MR-controlled RF hyperthermia in a hybrid system is well established in phantoms and already feasible for patients in the pelvic and lower extremity region. Under optimal conditions the temperature accuracy might be in the range of 0.5 degrees C. However a variety of developments, especially sequences and post-processing modules, are still required for the clinical routine.

Humans↗

[Molecular genetic studies on the immune system: an approach to a clinical application].

It is the function of the immune system to recognize and neutralize numerous antigens invading animals. The more diverse the antigen recognition of the organism, the more efficient is its defense system. There are two types of antigen recognition molecules in the immune system; the immunoglobulin produced by B cells and the T cell antigen receptor. These molecules have variable (V) regions which recognize antigens and constant (C) regions which mediate physiological functions. The latter provide additional diversity to the immune system. For example, the same heavy chain (H) V regions recognizing influenza hemagglutinin are expressed as the mu, gamma, epsilon, and a chains, each of which constitutes a different class of the immunoglobulin. Since the V and C regions are encoded by separate sets of DNA segments, it is the genetic variability of the V gene that determines the antigen recognition diversity. Recent molecular genetic studies on the immunoglobulin gene and the T cell antigen receptor gene indicate that the V region genes of both molecules produce somatic as well as evolutionary variations. Somatic variations include joining of two or three germ-line segments by site-specific recombinations and somatic base replacements. Evolutionary variations include gene duplication, segment transfer (gene conversion), mutational drifts, and so on. Since genetic events, be it somatic or evolutionary, tend to be random, not only useful but also harmful immunoglobulins are produced. Therefore, appropriate selection, be it positive or negative, is a prerequisite for the proper function of the genetic diversity of the immune system as the defense mechanism.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Unidirectional drift of fronts under zero-mean force, and broken symmetries of the rate function.

The deterministic front-ratchet effect, namely, the unidirectional transport of the bistable fronts (BFs) under the additive zero-mean ac forcing, is considered within the piecewise-linear model of the bistable system. Two different mechanisms underlying the front ratchet, two cases of the broken symmetry of (i) the rate function, and/or (ii) the external zero-mean ac forcing are analyzed. Types of unidirectional motion, some versions of the "unforced" migration of BFs, are found in both cases of the travelling (initially propagating) and the static (motionless) fronts. We show that symmetry breaking in the front ratchet could produce progressive, regressive, and reversal types of the unidirectional motion of traveling BFs. By tuning the parameters of the rate function the propagation direction of BF exhibits reversal, as a function of the amplitude of the applied ac forcing. The static BFs, which stay initially at rest, can gain the dc motion discussed if the symmetry of either the rate function or the applied ac forcing is broken. The adiabatic approximation is used. To perform a rigorous analytic treatment for the arbitrary strengths of the driving force we assume that the frequency of the applied ac forcing is small, if compared to the characteristic relaxation rates in the system.

Journal Article↗

The simultaneous measurement of low rates of CO2 and O2 exchange in biological systems.

An instrument for measuring low rates of biological O2 exchange using an open-flow gas analysis system is described. A novel differential O2 sensor that is capable of measuring as little as 0.4 Pa O2 against a back-ground of ambient air (20,900 Pa O2), yet has a dynamic range of +/- 2000 Pa O2 (i.e., +/- ca. 2% O2) is described. Baseline drift was typically less than 0.025 Pa min-1. The differential O2 sensor was incorporated into a respiratory quotient/photosynthetic quotient analyzer that contained other environmental sensors for atmospheric pressure, absolute O2 and CO2 concentration, temperature of the differential O2 sensor block, and differential pressure between reference and sample streams. Protocols for how these sensors can be used to calibrate the differential O2 sensor and to improve its stability with time are described. Together, the differential O2 sensor, the environmental sensors, and the simple calibration techniques allow for simultaneous, noninvasive, and accurate measurements of O2 and CO2 exchange in tissues with metabolic rates as low as about 0.1 mumol O2 or CO2 h-1. Example data are provided in which O2 differentials of 3 to 41 Pa O2 were measured in an open-flow system.

Animals↗

Patterns of protein evolution in Tetrahymena thermophila: implications for estimates of effective population size.

High levels of synonymous substitutions among alleles of the surface antigen SerH led to the hypothesis that Tetrahymena thermophila has a tremendously large effective population size, one that is greater than estimated for many prokaryotes (Lynch, M., and J. S. Conery. 2003. Science 302:1401-1404.). Here we show that SerH is unusual as there are substantially lower levels of synonymous variation at five additional loci (four nuclear and one mitochondrial) characterized from T. thermophila populations. Hence, the effective population size of T. thermophila, a model single-celled eukaryote, is lower and more consistent with estimates from other microbial eukaryotes. Moreover, reanalysis of SerH polymorphism data indicates that this protein evolves through a combination of vertical transmission of alleles and concerted evolution of repeat units within alleles. SerH may be under balancing selection due to a mechanism analogous to the maintenance of antigenic variation in vertebrate immune systems. Finally, the dual nature of ciliate genomes and particularly the amitotic divisions of processed macronuclear genomes may make it difficult to estimate accurately effective population size from synonymous polymorphisms. This is because selection and drift operate on processed chromosomes in macronuclei, where assortment of alleles, disruption of linkage groups, and recombination can alter the genetic landscape relative to more canonical eukaryotic genomes.

Alleles↗

Head movement associated with performance of mandibular tasks.

The present study was designed to examine the hypothesis that the motor system controlling phonation is functionally coupled with the motor system controlling posture of the head and neck, as previously suggested (U. Haddar, T.J. Steiner, E.C. Grant and F.C. Rose Human Movement Science 2: 35 and Language and Speech 26: 117). Head tilt and trunk drift in the antero-posterior and right-left directions were measured simultaneously for 20 s before and during three types of speech sounds (/pa/, /ta/ and /ka/) as well during a maximum jaw open-close task in 14 healthy young subjects. The major findings obtained in all of the four tasks were: (i) the trunk drift measured in both directions was negligible in comparison with the head tilt; (ii) the head tilt in the antero-posterior direction was much larger than in the right-left direction and (iii) the head tilt during performance of the four tasks consisted of 'initial' and 'sustained' phases. In the initial phase, the head tilted posteriorly in association with the start of individual tasks. In the sustained phase, the head tilted either anteriorly or posteriorly when the task progressed. The magnitude of the net head tilt in the sustained phase negatively correlated with that of the initial head tilt. These findings indicate that phonation, in the form of jaw open-close, accompanies head movement in two consecutive phases.

Adult↗

Implications of rotational kinematics for the oculomotor system in three dimensions.

1. This paper develops three-dimensional models for the vestibuloocular reflex (VOR) and the internal feedback loop of the saccadic system. The models differ qualitatively from previous, one-dimensional versions, because the commutative algebra used in previous models does not apply to the three-dimensional rotations of the eye. 2. The hypothesis that eye position signals are generated by an eye velocity integrator in the indirect path of the VOR must be rejected because in three dimensions the integral of angular velocity does not specify angular position. Computer simulations using eye velocity integrators show large, cumulative gaze errors and post-VOR drift. We describe a simple velocity to position transformation that works in three dimensions. 3. In the feedback control of saccades, eye position error is not the vector difference between actual and desired eye positions. Subtractive feedback models must continuously adjust the axis of rotation throughout a saccade, and they generate meandering, dysmetric gaze saccades. We describe a multiplicative feedback system that solves these problems and generates fixed-axis saccades that accord with Listing's law. 4. We show that Listing's law requires that most saccades have their axes out of Listing's plane. A corollary is that if three pools of short-lead burst neurons code the eye velocity command during saccades, the three pools are not yoked, but function independently during visually triggered saccades. 5. In our three-dimensional models, we represent eye position using four-component rotational operators called quaternions. This is not the only algebraic system for describing rotations, but it is the one that best fits the needs of the oculomotor system, and it yields much simpler models than do rotation matrix or other representations. 6. Quaternion models predict that eye position is represented on four channels in the oculomotor system: three for the vector components of eye position and one inversely related to gaze eccentricity and torsion. 7. Many testable predictions made by quaternion models also turn up in models based on other mathematics. These predictions are therefore more fundamental than the specific models that generate them. Among these predictions are 1) to compute eye position in the indirect path of the VOR, eye or head velocity signals are multiplied by eye position feedback and then integrated; consequently 2) eye position signals and eye or head velocity signals converge on vestibular neurons, and their interaction is multiplicative.(ABSTRACT TRUNCATED AT 400 WORDS)

Computer Simulation↗

Influenza vaccination in older patients. Immunogenicity, epidemiology and available agents.

Excess hospitalisation and deaths attributable to influenza virus infections often occur during epidemics and even in interepidemic periods. Influenza vaccines in current use are inactivated preparations that contain 15 micrograms each of the most recently circulating influenza A (H3N2 and H1N1) and B viruses. At present, 3 types of inactivated influenza virus vaccines are available: (a) whole virus vaccines; (b) split virus vaccines; and (c) subunit vaccines. All 3 types are similarly immunogenic in primed patients. Vaccine efficacy depends on a close antigenic match between the vaccine composition and the influenza strains circulating in the human population. The continuous antigenic drift of the viral membrane antigens (haemagglutinin and neuraminidase) necessitates an update of the vaccine composition each year according to the recommendations of the World Health Organization (WHO). Subunit and split virus vaccines cause fewer systemic reactions than whole virus vaccines. At present, live attenuated influenza virus vaccines are not licensed. In perspective, combined administration of live and inactivated vaccines seems to be advantageous. Influenza vaccine is approximately 75% effective in reducing deaths in elderly and high risk persons. Several studies have shown that the antiviral agent amantadine is a useful adjunct to vaccination for preventing influenza A in institutional settings. Currently, the proper use of inactivated vaccine according to the recommendations of public health authorities is the only way to reduce the annual influenza-associated medical and economic burden.

Aged↗

A quality control system and its application to clinical chemistry.

A quality control system is presented that involves the Quality Control Log for documenting data, decisions, and corrective actions. It emphasizes the use of the Calibration Work Record, cusum, and comparison of means to monitor acute and chronic drift and method bias. It introduces clinically useful limits criteria for efficient and cost-effective quality control.

Calibration↗

Cross-correlation analyses of nonlinear systems with spatiotemporal inputs.

Methods are presented for analyzing the low-order stimulus-response cross-correlation functions (or kernels) of visual neurons studied with spatiotemporal white noise. In particular, formulas are derived that relate the low-order kernels of a cell to its responses to single-drifting, double-drifting, and counterphase gratings. The harmonic response terms contributed by the low-order kernels include a mean response term, first- and second-harmonic terms, and sum- and difference-harmonic terms. Using the formulas in this paper, one can obtain kernel-based predictions for the spatiotemporal-frequency tuning of each harmonic. These kernel-based predictions can then be compared with harmonic tuning data obtained in experiments with real grating stimuli. The methods are illustrated using data recorded from one simple and one complex cell from the primary visual cortex of the monkey. The approach of transforming low-order kernels into predicted harmonic tuning functions provides a useful data reduction technique as well as providing insight into the interpretation of kernels.

Animals↗

A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT).

Magnetic induction tomography (MIT) is a low-resolution imaging modality which aims at the three-dimensional (3D) reconstruction of the electrical conductivity in objects from alternating magnetic fields. In MIT systems the magnetic field perturbations to be detected are very small when compared to the excitation field (ppm range). The voltage which is induced by the excitation field in the receiver coils must be suppressed for providing sufficient dynamic range. In the past, two very efficient strategies were proposed: adjusted planar gradiometers (PGRAD) and the orientation of a receiver coil with respect to the excitation coil such that the net magnetic flow is zero (zero flow coil, ZFC). In contrast to the PGRAD no voltage is induced in the ZFC by the main field. This is advantageous because two comparatively high voltages in the two gradiometer coils can never be subtracted perfectly, thus leaving a residual voltage which is prone to drift. However, a disadvantage of the ZFC is the higher susceptibility to interferences from far RF sources. In contrast, in the gradiometer such interferences are cancelled to a high degree. We developed a new type of gradiometer (zero flow gradiometer, ZFGRAD) which combines the advantages of ZFC and PGRAD. All three systems were compared with respect to sensitivity and perturbation to signal ratio (PSR) defined as the ratio of the signal change due to a magnetic perturbation field at the carrier frequency and the signal change due to shifting a metallic sphere between two test points. The spatial sensitivity of the three systems was found to be very similar. The PSR of the ZFGRAD was more than 12 times lower than that of the ZFC. Finally, the feasibility of image reconstruction with two arrays of eight excitation coils and eight ZFGRAD, respectively, was shown with a single-step Gauss-Newton reconstructor and simulated measurement data generated for a cylindrical tank with a spherical perturbation. The resulting images show a clear, bright feature at the correct position of the sphere and are comparable to those with PGRAD arrays.

Animals↗

pH gradient electrophoresis and isoelectric focusing of lipoproteins on agarose bead thin layers.

A new method of isoelectric focusing (IEF) and pH gradient electrophoresis, using thin layers of agarose gel beads, was devised to investigate chylomicrons and very low density lipoproteins (VLDL). pH gradient stability and cathodal gradient drift were similar to those of polyacrylamide gel IEF, and linearity of gradients was maintained for 23 hr. Chylomicrons and VLDL were detectable without staining. Chylomicrons from human serum and from rat lymph migrated in this system. Rat lymph chylomicrons, obtained by ultracentrifugation, migrated in several discrete bands, and this heterogeneity or rat chylomicrons was confirmed by electron microscopic demonstration of chylomicrons in each band. This new technique has permitted the first measurement of isoelectric points of some lipoproteins in the ultracentrifuged fraction of human serum chylomicrons and the first separation of multiple discrete fractions of ultracentrifuged lymph chylomicrons.

Animals↗

Visual features that vary together over time group together over space.

The visual system perceives objects as coherent even when some parts are hidden or discontinuous. How this representation is constructed from local features of many nearby objects is termed the 'binding problem.' Here we manipulate contrast in several drifting gratings that can be perceived as either independent objects or parts of a single object. Contrast modulations that are correlated in time enhance perceptual coherence, whereas uncorrelated modulations impair coherence. Presumably, correlated contrast modulations produce correlated responses in cortical neurons. Therefore, our results are consistent with the hypothesis that temporal correlation of neural activity is important for feature binding.

Contrast Sensitivity↗

In situ multi-satellite detection of coherent vortices as a manifestation of Alfvénic turbulence.

Turbulence in fluids and plasmas is a ubiquitous phenomenon driven by a variety of sources-currents, sheared flows, gradients in density and temperature, and so on. Turbulence involves fluctuations of physical properties on many different scales, which interact nonlinearly to produce self-organized structures in the form of vortices. Vortex motion in fluids and magnetized plasmas is typically governed by nonlinear equations, examples of which include the Navier-Stokes equation, the Charney-Hasegawa-Mima equations and their numerous generalizations. These nonlinear equations admit solutions in the form of different types of vortices that are frequently observed in a variety of contexts: in atmospheres, in oceans and planetary systems, in the heliosphere, in the Earth's ionosphere and magnetosphere, and in laboratory plasma experiments. Here we report the discovery by the Cluster satellites of a distinct class of vortex motion-short-scale drift-kinetic Alfvén (DKA) vortices-in the Earth's magnetospheric cusp region. As is the case for the larger Kelvin-Helmholtz vortices observed previously, these dynamic structures should provide a channel for transporting plasma particles and energy through the magnetospheric boundary layers.

Journal Article↗

ED(27) trophoblast-like cells isolated from first-trimester chorionic villi are genetically identical to HeLa cells yet exhibit a distinct phenotype.

ED(27) trophoblast-like cells were prepared from human chorionic villus samples obtained at 9 weeks gestation and have been grown continuously in vitro without phenotypic drift for nearly a decade. These cells express many trophoblast markers, including cytokeratin, placental alkaline phosphatase (PLAP), secretion of 17beta-estradiol, and a microvillous apical surface. The ED(27) cell line is a useful model system for studies of placental cell biology and has been distributed to laboratories world-wide. However, experiments to investigate their relationship to primary villous cytotrophoblast have shown that these cells do not secrete detectable amounts of human chorionic gonadotropin in culture and, when digested with trypsin, disperse into individual cells. Furthermore, immunocytochemical studies demonstrated that, unlike villous cytotrophoblasts, ED(27) cells were immunoreactive with monoclonal antibodies recognizing some HLA Class I antigens. This was not HLA-G, however, as would be expected if these cells originated from extravillous cytotrophoblasts, but rather classical HLA-A, B which is thought not to be expressed by any trophoblast subpopulations. These inconsistencies prompted us to question the authenticity of the continuous cell line as it now exists. Genetic haplotype analysis using the polymerase chain reaction (PCR) revealed that ED(27) was genetically identically to the HeLa cell line. Inasmuch as HeLa cells have never been grown in the laboratory (DAK), the only possible origin of HeLa cell contamination of ED(27) cells was the WISH cell line, and further PCR analysis revealed that this cell line was also genetically identical to HeLa. Like ED(27) cells, HeLa cells and WISH cells synthesized small amounts of estrogen and were found to express PLAP and antigens recognized by the monoclonal antibodies ED822, directed against the syncytiotrophoblast, and J1B5 directed against villous cytotrophoblast. These results point out the need for adherence to rigorous and consistent quality control measures to assure the authenticity of cell lines used as in vitro model systems.

Adult↗