PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Sequence-selective DNA detection using multiple laminar streams: a novel microfluidic analysis method.

On-site detection methods for DNA have been demanded in the pathophysiology field. Such analysis requires a simple and accurate method, rather than high-throughput. This report describes a novel microfluidic analysis method and its application for simple sequence-selective DNA detection. The method uses a microchannel device with a serpentine structure. Sequence-specific binding of probe DNA can be detected at one side of the microchannel. This method is capable of sequence-specific detection of DNA with high accuracy. Single base mutations can also be analyzed. Combination of laminar stream and laminar secondary flow in the microchannel enable specific detection of probe-bound DNA.

Base Sequence↗

Combinatorial mixing of microfluidic streams.

We have devised a microfluidic mixer design that produces all the mixture combinations of a given number of dilutions of the input compounds. As proof of the concept, we present a device that generates four titrations of two dye solutions, blue and yellow, and combinatorially mixes the blue titrations with the yellow titrations to deliver the sixteen mixture combinations in separate outlet microchannels. Our device features four different flow levels made by stacking nine laser-cut Mylar laminates. The fluidic network has a symmetric design that guarantees that the flow rates are the same at all the outlets, with deviations attributable to imperfections in the fabrication, assembly, or perfusion processes. Design rules for scaling up the number of compounds and/or dilutions are presented. The mixing scheme has broad applicability in high-throughput combinatorial testing applications such as drug screening, cell-based biochemical assays, lab-on-a-chip devices, and biosensors.

Equipment Design↗

A microfluidic device to confine a single cardiac myocyte in a sub-nanoliter volume on planar microelectrodes for extracellular potential recordings.

A hybrid chip is described which combines a microfluidic network fabricated in a silicone elastomer (PDMS) with planar microelectrodes. It was used to measure extracellular potentials from single adult murine cardiac myocytes in a restricted extracellular space. The recorded variations in the extracellular potentials were caused by transmembrane currents associated with spontaneously initiated intracellular calcium waves. Single cells were trapped inside the 100 pl microchamber by pressure gradients and maintained for several hours by continuous perfusion. In addition, the localized delivery of drugs to a portion of the cell was demonstrated. The impedance of the electrodes was reduced by a factor of 10 to 20 after the electrodeposition of platinum black. Biopotentials recorded from single cells with platinum black electrodes showed a three-fold decrease in the noise, resulting in a maximum signal-to-noise ratio of 15:1. Characteristic variations in the frequency and shape of the extracellular potentials were observed among different cells which are most likely due to differences in the sarcoplasmic reticulum Ca(2+) load. Our device architecture permits the integration of electrochemical and optical sensors for multiparameter recordings.

Animals↗

Biomimetic technique for adhesion-based collection and separation of cells in a microfluidic channel.

A basic step in many biological assays is separating and isolating different types of cells from raw samples. To better meet these requirements in microfluidic devices for miniature biomedical analytical systems, an alternative method for separating cells has been devised by mimicking the physiological process of leukocyte recruitment to blood vessel walls: adhesive cell rolling and transient tethering. Reproducing these interactions for cells on surfaces of microstructured fluidic channels can serve to capture and concentrate cells and even to fractionate different cell types from a continuously flowing sample. To demonstrate this principle, two designs for microstructured fluidic channels were fabricated: an array of Square pillars and another with slender, Offset pillars. These structures were coated with E-selectin IgG chimera and the interactions of HL-60 and U-937 cells with these structures were characterized. With inflow of fluidic cell suspensions, the structures were able to efficiently capture and arrest cells directly from the rapid free stream flow. After capture, cells transit through the channel in three phases: cell rolling, cell tethering, and transient re-suspension in free stream flow before re-capture. Under these interactions, captured cells were enriched several hundred-fold from the original concentration. Additionally, among collected cells, the difference in flow-driven, adhesion-mediated cell transit in the Square design suggested that the two cell types could at least be partially fractionated.

Biomimetics↗

Microfluidic biosensing systems. Part I. Development and optimisation of enzymatic chemiluminescent micro-biosensors based on silicon microchips.

Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (micro-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the micro-biosensors in a microfluidic sequential injection analysis (microSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the microSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 2(3)-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 microM luminol and 150 microM PIP at a flow rate of 18 microl min(-1), the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both micro-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP micro-biosensors responded linear in a log-log format within the range 10-1000 microM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP micro-biosensors responded linear (log-log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2-3 days.

Biosensing Techniques↗

Cell lysis on a microfluidic CD (compact disc).

Cell lysis was demonstrated on a microfluidic CD (Compact Disc) platform. In this purely mechanical lysis method, spherical particles (beads) in a lysis chamber microfabricated in a CD, cause disruption of mammalian (CHO-K1), bacterial (Escherichia coli), and yeast (Saccharomyces cerevisiae) cells. Interactions between beads and cells are generated in the rimming flow established inside a partially filled annular chamber in the CD rotating around a horizontal axis. To maximize bead-cell interactions in the lysis chamber, the CD was spun forward and backwards around this axis, using high acceleration for 5 to 7 min. Investigation on inter-particle forces (friction and collision) identified the following parameters; bead density, angular velocity, acceleration rate, and solid volume fraction as having the most significant contribution to cell lysis. Cell disruption efficiency was verified either through direct microscopic viewing or measurement of the DNA concentration after cell lysing. Lysis efficiency relative to a conventional lysis protocol was approximately 65%. In the long term, this work is geared towards CD based sample-to-answer nucleic acid analysis which will include cell lysis, DNA purification, DNA amplification, and DNA hybridization detection.

Animals↗

Filter-based microfluidic device as a platform for immunofluorescent assay of microbial cells.

A filter-based microfluidic device was combined with immunofluorescent labeling as a platform to rapidly detect microbial cells. The coin-sized device consisted of micro-chambers, micro-channels and filter weirs (gap = 1-2 microm), and was demonstrated to effectively trap and concentrate microbial cells (i.e., Cryptosporidium parvum and Giardia lamblia), which were larger in size than the weir gap. After sample injection, a staining solution containing fluorescently-labeled antibodies was continuously provided into the device (flow rate = 20 microl min(-1)) to flush the microbial cells toward the weirs and to accelerate the fluorescent labeling reaction. Using a staining solution that was 10 to 100 times more dilute than the recommended concentration used in a conventional glass method, those target cells with a fluorescent signal-to-noise ratio of 12 could be microscopically observed at single-cell level within 2 to 5 min prior to secondary washing.

Animals↗

Design of microfluidic channel geometries for the control of droplet volume, chemical concentration, and sorting.

Passive microfluidic channel geometries for control of droplet fission, fusion and sorting are designed, fabricated, and tested. In droplet fission, the inlet width of the bifurcating junction is used to control the range of breakable droplet sizes and the relative resistances of the daughter channels were used to control the volume of the daughter droplets. Droplet fission is shown to produce concentration differences in the daughter droplets generated from a primary drop with an incompletely mixed chemical gradient, and for droplets in each of the bifurcated channels, droplets were found to be monodispersed with a less than 2% variation in size. Droplet fusion is demonstrated using a flow rectifying design that can fuse multiple droplets of same or different sizes generated at various frequencies. Droplet sorting is achieved using a bifurcating flow design that allows droplets to be separated base on their sizes by controlling the widths of the daughter channels. Using this sorting design, submicron satellite droplets are separated from the larger droplets.

Equipment Design↗

Precise temperature control in microfluidic devices using Joule heating of ionic liquids.

Microfluidic devices for spatially localised heating of microchannel environments were designed, fabricated and tested. The devices are simple to implement, do not require complex manufacturing steps and enable intra-channel temperature control to within +/-0.2 degrees C. Ionic liquids held in co-running channels are Joule heated with an a.c. current. The nature of the devices means that the internal temperature can be directly assessed in a facile manner.

Equipment Design↗

Robust polymer microfluidic device fabrication via contact liquid photolithographic polymerization (CLiPP).

Microfluidic devices are commonly fabricated in silicon or glass using micromachining technology or elastomers using soft lithography methods; however, invariable bulk material properties, limited surface modification methods and difficulty in fabricating high aspect ratio devices prevent these materials from being utilized in numerous applications and/or lead to high fabrication costs. Contact Liquid Photolithographic Polymerization (CLiPP) was developed as an alternative microfabrication approach that uniquely exploits living radical photopolymerization chemistry to facilitate surface modification of device components, fabrication of high aspect ratio structures from many different materials with numerous covalently-adhered layers and facile construction of three-dimensional devices. This contribution describes CLiPP and demonstrates unique advantages of this new technology for microfabrication of polymeric microdevices. Specifically, the procedure for fabricating devices with CLiPP is presented, the living radical photopolymerization chemistry which enables this technology is described, and examples of devices made using CLiPP are shown.

Equipment Design↗

A microfluidic method for removal of the zona pellucida from mammalian embryos.

Many in vitro procedures involve manipulation of the zona pellucida (chimerics, transgenics, biopsy). We have demonstrated a microfluidic channel network to precisely control (spatially and temporally) the delivery of chemical treatments for the removal of the zona pellucida. Building devices in polydimethylsiloxane (PDMS) with channel dimensions on the same order as that of the embryo diameter (approximately 120 microm) allows precise control of the local fluid environment. The system uses pressure driven flows to control embryo positioning, embryo movement, and plug formation. Zona removal is achieved by briefly washing a plug of lysing agent (acid Tyrode's medium) over the embryo.

Animals↗

A microfluidic device based on gravity and electric force driving for flow cytometry and fluorescence activated cell sorting.

A novel method based on gravity and electric force driving of cells was developed for flow cytometry and fluorescence activated cell sorting in a microfluidic chip system. In the experiments cells flowed spontaneously under their own gravity in a upright microchip, passed through the detection region and then entered into the sorting electric field one by one at an average velocity of 0.55 mm s(-1) and were fluorescence activated cell sorted (FACS) by a switch-off activation program. In order to study the dynamical and kinematic characteristics of single cells in gravity and electric field of microchannels a physical and numerical module based on Newton's Law of motion was established and optimized. Hydroxylpropylmethyl cellulose (HPMC) was used to minimize cell assembling, sedimentation and adsorption to microchannels. This system was applied to estimate the necrotic and apoptotic effects of ultraviolet (UV) light on HeLa cells by exposing them to UV radiation for 10, 20 or 40 min and the results showed that UV radiation induced membrane damage contributed to the apoptosis and necrosis of HeLa cells.

Apoptosis↗

High-sensitivity miniaturized immunoassays for tumor necrosis factor alpha using microfluidic systems.

We use microfluidic chips to detect the biologically important cytokine tumor necrosis factor alpha (TNF- alpha) with picomolar sensitivity using sub-microliter volumes of samples and reagents. The chips comprise a number of independent capillary systems (CSs), each of which is composed of a filling port, an appended microchannel, and a capillary pump. Each CS fills spontaneously by capillary forces and includes a self-regulating mechanism that prevents adventitious drainage of the microchannels. Thus, interactive control of the flow in each CS is easily achieved via collective control of the evaporation in all CSs by means of two Peltier elements that can independently heat and cool. Long incubation times are crucial for high sensitivity assays and can be conveniently obtained by adjusting the evaporation rate to have low flow rates of approximately 30 nL min(-1). The assay is a sandwich fluorescence immunoassay and takes place on the surface of a poly(dimethylsiloxane)(PDMS) slab placed across the microchannels. We precoat PDMS with capture antibodies (Abs), localize the capture of analyte molecules using a chip, then bind the captured analyte molecules with fluorescently-tagged detection Abs using a second chip. The assay results in a mosaic of fluorescence signals on the PDMS surface which are measured using a fluorescence scanner. We show that PDMS is a compatible material for high sensitivity fluorescence assays, provided that detection antibodies with long excitation wavelength fluorophores ( > or =580 nm) are employed. The chip design, long incubation times, proper choice of fluorophores, and optimization of the detection Ab concentration all combine to achieve high-sensitivity assays. This is exemplified by an experiment with 170 assay sites, occupying an area of approximately 0.6 mm(2) on PDMS to detect TNF-alpha in 600 nL of a dendritic cell (DC) culture medium with a sensitivity of approximately 20 pg mL(-1)(1.14 pM).

Antibodies↗

Immunomagnetic T cell capture from blood for PCR analysis using microfluidic systems.

A one-step immunomagnetic separation technique was performed on a microfluidic platform for the isolation of specific cells from blood samples. The cell isolation and purification studies targeted T cells, as a model for low abundance cells (about 1:10,000 cells), with more dilute cells as the ultimate goal. T cells were successfully separated on-chip from human blood and from reconstituted blood samples. Quantitative polymerase chain reaction analysis of the captured cells was used to characterize the efficiency of T cell capture in a variety of flow path designs. Employing many (4-8), 50 microm deep narrow channels, with the same overall cross section as a single, 3 mm wide channel, was much more effective in structuring dense enough magnetic bead beds to trap cells in a flowing stream. The use of 8-multiple bifurcated flow paths increased capture efficiencies from approximately 20 up to 37%, when compared to a straight 8-way split design, indicating the value of ensuring uniform flow distribution into each channel in a flow manifold for effective cell capture. Sample flow rates of up to 3 microL min(-1) were evaluated in these capture beds.

Blood Cell Count↗

Microfluidic solid phase suspension transport with an elastomer-based, single piezo-actuator, micro throttle pump.

We report a Micro Throttle Pump (MTP) which has been shown to pump 5 microm diameter polystyrene beads at a concentration of 4.5 x 10(7) beads ml(-1). This new MTP design is constructed in a straightforward manner and actuated by a single piezoelectric (PZT) element. Maximum flow rates at 800 Hz drive frequency of 132 microl min(-1) with water and 108 microl min(-1) with a bead suspension were obtained. Maximum back-pressures of 6 kPa were observed in both cases. The reported MTP employs specific location of distinct internal microfluid structures cast in a single compliant elastomeric substrate to exploit the opposing directions of flexure of regions of a piezoelectric-glass composite bonded to the elastomer. By this novel means, distinct flexural regions, exhibiting compressive and tensile stresses respectively, allow both the pump's integrated input and output throttles and its pump chamber to be actuated concurrently by a single PZT. To support MTP design we also report the characterisation of an individual throttle's resistance as a function of actuator deflection and discuss the underlying mechanism of the throttling effect.

Elastomers↗

Dynamics of capillary flow of blood into a microfluidic channel.

In this paper, a novel mathematical approach is devised to analyze the flow of blood from a droplet into a microcapillary channel. Special attention is devoted to estimate the effects of variable hydraulic resistance over different flow regimes, influence of suspended RBC particulates on the non-Newtonian flow characteristics and implications of a dynamically-evolving contact angle. Flow characteristics depicting advancement of the fluid within the microfluidic channel turn out to be typically non-linear, as per relative instantaneous strengths of the capillary forces and viscous resistances. It is found that the greater the 'pseudoplasticity' of the blood, the weaker the retarding shear forces. The driving forces, on the other hand, become stronger with time, on account of a reduction of contact angle with a decrease of blood flow velocity, although this strengthening is less prominent for blood samples with greater 'pseudoplasticity'. It is revealed that RBCs suspended in blood samples have a strong influence on the effective blood viscosity, and consequently, may drive the fluid significantly faster into the microchannel, especially when the characteristic length scales of the suspensions approach the hydraulic radius of the channel.

Blood Flow Velocity↗

A microfluidic system enabling Raman measurements of the oxygenation cycle in single optically trapped red blood cells.

Using a lab-on-a-chip approach we demonstrate the possibility of selecting a single cell with certain properties and following its dynamics after an environmental stimulation in real time using Raman spectroscopy. This is accomplished by combining a micro Raman set-up with optical tweezers and a microfluidic system. The latter gives full control over the media surrounding the cell, and it consists of a pattern of channels and reservoirs defined by electron beam lithography that is moulded into rubber silicon (PDMS). Different buffers can be transported through the channels using electro-osmotic flow, while the resonance Raman response of an optically trapped red blood cell (RBC) is simultaneously registered. This makes it possible to monitor the oxygenation cycle of the cell in real time and to investigate effects like photo-induced chemistry caused by the illumination. The experimental set-up has high potential for in vivo monitoring of cellular drug response using a variety of spectroscopic probes.

Adult↗

Parylene flexible neural probes integrated with microfluidic channels.

The fluidic channel in the flexible probe has three functions: (i) to inject chemicals into the tissues, (ii) to measure the neural activities from the tissues, and (iii) to improve the mechanical stiffness of the probe by filling the channel with a solid material. A 10-microm-thick microfluidic channel was embedded into the probe by using sacrificial photoresist patterns. Polyethylene glycol (PEG), which is solid at room temperature and dissolves when in contact with water, was used to fill the channel and increase the stiffness of the probe before insertion into the tissue. The impedance of the electrode inside the fluidic channel was around 100 kOmega at 1 kHz when the channel was filled with saline solution. We were able to insert the probe into a rat's brain and measure the neural signals with the electrode.

Animals↗