Nerve grafting in peripheral nerve microsurgery of the upper extremity.

The use of microsurgical techniques is essential in peripheral nerve surgery, in which dissection at the fascicular level is required. Magnification with an operating microscope allows for an accurate evaluation of the severity of the trauma to the nerve tissue and permits atraumatic interfascicular dissection. Fascicular or interfascicular dissection and repair with the use of nerve grafts was carried out in 220 peripheral nerve lesions of the upper extremity. Our results of nerve-grafting in the upper extremity (median, ulnar, and radial-nerves) indicate an inverse association between the age of the patient and the delay between injury and grafting. In addition, we found that nerve grafting without tension produces superior results over simple neurorrhaphy under tension and permits better axonal growth and nerve recovery.

Adolescent↗

Reconstructive microsurgery of lymph vessels: the personal method of lymphatic-venous-lymphatic (LVL) interpositioned grafted shunt.

Our clinical observations in 64 patients affected by chronic obstructive lymphedema (either arm or leg) undergoing interposition autologous lymphatic-venous-lymphatic (LVL) anastomoses are reported. This microsurgical technique is an alternative to other lymphatic shunting methods, especially when venous dysfunction coexists in the same limb and, therefore, when direct lymphatic-venous anastomosis is accordingly inadequate. Preoperative diagnostic evaluation (including lymphatic and venous isotopic scintigraphy, Doppler venous flowmetrics, and pressure manometry) plays an essential role in assessing the conditions of both the lymphatic and venous systems and in establishing which microsurgical procedure, if any, is indicated. Our microsurgical technique consists of inserting suitably large and lengthy autologous venous grafts between lymphatic collectors above and below the site of obstruction to lymph flow. The data show that, using this technique, both limb function and edema improved, and in all patients followed up for over 5 years edema regression was permanent.

Anastomosis, Surgical↗

Derivative lymphatic microsurgery: indications, techniques, and results.

Microsurgical derivative procedures to treat chronic lymphedemas of the limbs are reported here. Techniques used consisted of lymphatic capsule-venous anastomoses (in pediatric patients) and end-to-side lymphatic-venous anastomoses. Results after more than 5 years showed improvement in about 70% of the cases. The importance of an accurate preoperative diagnostic evaluation and the precise indications for these microsurgical procedures are discussed. Some personal modifications of derivative microsurgical techniques and their advantages are also pointed out.

Adult↗

Atraumatic suction tip for microsurgery: technical note.

During microneurosurgery, frequent suction is essential for a successful operative course. A new self-made disposable suction tip is described which facilitates atraumatic suction, even near vital anatomical structures. The efficacy of this suction tip was confirmed in selected operative procedures.

Humans↗

Robotics in microsurgery: use of a surgical robot to perform a free flap in a pig.

We present the concept that a surgical robot may be used to successfully perform a free flap. To study different microsurgical techniques, a porcine free flap model was developed in our laboratory. Dissection of the free flap model and isolation of the vessels were completed under traditional loupe magnification. The da Vinci robot was then used to perform vessel adventitiectomy and microanastomoses. The model was observed for 4 h postoperatively, noting flap color, temperature, capillary refill, and Doppler signal. At the end of this period, the flap was noted to be viable; anastomoses were evaluated and found to be grossly and microscopically patent. Advantages conferred by the da Vinci robot include elimination of tremor, scalable movements, fully articulating instruments with six degrees of spatial freedom, and a dynamic three-dimensional visualization system. Drawbacks include the cost and the absence of true microsurgical instruments.

Anastomosis, Surgical↗

Is there a role for microsurgery in the prevention of arm lymphedema secondary to breast cancer treatment?

The secondary lymphedema of the upper limb (post-mastectomy lymphedema) has an incidence, in patients who underwent axillary lymphadenectomy for breast cancer, between 5 to 25%, up to 40% after radiotherapic treatment. We studied 50 patients treated for breast cancer. The patients were divided in two groups of 25 each, comparable for age, sex, pathology and treatment and followed up to 5 years after operation for breast. One group of 25 patients was controlled only clinically (physical examination, water volumetry) at 1-3-6 months and 1-3-5 years from breast cancer treatment. The other group of 25 patients was followed also by lymphatic scintigraphy performed pre-operatively and after 1-3-6 months and 1-3-5 years from operation. In the first group, followed only clinically, lymphedema appeared in 9 patients after a period variable from 1 week to 2 years, with highest incidence between 3 and 6 months. In the second group of 25 patients, the preventive therapeutic protocol allowed to have a clinically evident arm lymphedema only in 2 patients. The comparison of the two groups of 25 patients proved a statistically significant difference in the appearance of arm secondary lymphedema (p = 0.01, using Fisher's exact test). The diagnostic and therapeutic preventive procedures allow to reduce the incidence rate of lymphedema significantly, in comparison with patients who did not undergo this protocol of prevention.

Adenocarcinoma↗

Collaboration with microsurgery prevents arterial complications and provides superior success in partial liver transplantation.

Hepatic artery thrombosis is the most common technical complication in liver transplantation. The objective of this study was to investigate the arterial complications of partial liver transplantation using microsurgical technique. At a period of 31-months, we participated in a total of 42 right lobes, 7 left lobes, and 1 whole-liver liver transplantations from cadaveric (n = 20) or living (n = 30) donors. Hepatic artery anastomosis was performed using microsurgical techniques. All anastomoses were accomplished successfully. Fifteen patients expired postoperatively and 35 hepatic artery anastomoses remained patent at a mean follow-up period of 10.6 +/- 8.4 months. The mean diameters of the donor and recipient hepatic arteries were 2.9 +/- 1.2 mm and 3.2 +/- 1.1 mm, respectively. Specific technical challenges were encountered during operation in eight cases (16%). We have found that microsurgical techniques are not only useful for a superior anastomosis but also reliable to adapt to vascular anomalies with less arterial complications. complications.

Adult↗