PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Gas chromatography-mass spectrometry method for determining the methanol and acetic acid contents of pectin using headspace solid-phase microextraction and stable isotope dilution.

A simple, fast, and direct procedure was developed for the simultaneous determination of the methanol and acetic acid present as esters in the plant cell wall polysaccharide pectin. After base-hydrolysis of esters and acidification of pectin samples, headspace solid-phase microextraction (SPME) was performed using a Carboxen-PDMS fiber assembly. Methanol and acetic acid were separated by gas chromatography with a Chrompak PoraPlot Q capillary column and detected using electron impact mass spectrometry with selected ion monitoring. Stable deuterated isotopomers (d3-methanol and d3-acetic acid) were used as internal standards and for constructing calibration curves, providing accurate and absolute quantification of analytes. The methanol and acetic acid contents in 1 mg quantities of fruit and vegetable pectins were readily quantified by this procedure.

Acetic Acid↗

Non-equilibrium solid-phase microextraction coupled directly to ion-trap mass spectrometry for rapid analysis of biological samples.

To determine sub-ppb levels of drugs in biological samples, selective, sensitive and rapid analytical techniques are required. This work shows the possibilities for high-throughput analysis of solid-phase microextraction (SPME) directly coupled to an ion-trap mass spectrometer equipped with an atmospheric pressure chemical ionisation source. As no chromatographic separation is performed, the SPME procedure is the time-limiting step. Direct immersion SPME under non-equilibrium conditions permits the determination of lidocaine in urine within 10 min. After a 5 min sorption time with a 100 microm polydimethylsiloxane-coated fibre, the extraction yield of lidocaine from urine is about 7%. When applying 4 min desorption, using a mixture of ammonium acetate buffer (pH 4.5) and acetonitrile (85 + 15 v/v), about 10% of the analyte is retained on the fibre. An extra cleaning step of the fibre is therefore used to prevent carry-over. By use of tandem MS, no matrix interference is observed. The detection limit for lidocaine is about 0.4 ng ml(-1) and the intraday and interday reproducibility are within 14% over a concentration range of 2-45 ng ml(1).

Humans↗

Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography.

This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma. The method was based on immobilisation of 1.5 microliters of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5 an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300 degrees C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.

Acetic Acid↗

Quantitative determination of trimethylamine in urine by solid-phase microextraction and gas chromatography-mass spectrometry.

Trimethylaminuria (fish odour syndrome) is diagnosed from an increase in urinary excretion of trimethylamine with decreased trimethylamine oxide. We report a new quantitative stable isotope dilution gas chromatography-mass spectrometry procedure for the analysis of these metabolites using solid-phase microextraction (SPME). Both polydimethylsiloxane and mixed Carboxen-polydimethylsiloxane SPME fibres were found to be suitable for the headspace extraction of TMA. This new sampling technique could have wide application for the analysis of volatile and semi-volatile compounds by metabolic screening laboratories.

Gas Chromatography-Mass Spectrometry↗

Application of headspace solid phase microextraction to qualitative and quantitative analysis of tobacco additives in cigarettes.

Cigarettes may contain up to 10% by weight additives which are intended to make them more attractive. A fast and rugged method for a cigarette-screening for additives with medium volatility was developed using automatic headspace solid phase microextraction (HS-SPME) with a 65 microm carbowax-divinylbenzene fiber and gas chromatography-mass spectrometry (GC-MS) with standard electron impact ionisation. In three runs, each cigarette sample was extracted in closed headspace vials using basic, acidic and neutral medium containing 0.5 g NaCl or Na2SO4. Furthermore, the method was optimized for quantitative determination of 17 frequently occurring additives. The practical applicability of the method was demonstrated for cigarettes from 32 brands.

Gas Chromatography-Mass Spectrometry↗

Fast determination of curcumol, curdione and germacrone in three species of Curcuma rhizomes by microwave-assisted extraction followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

Curcumol, germacrone and curdione are the main active ingredients in a common traditional Chinese medicine (TCM) of Rhizoma Curcuma, and commonly used as the TCM quality control markers. In the present work, microwave-assisted extraction (MAE) followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) was developed for the quantitative analysis of curcumol, curdione and germacrone in Rhizoma Curcuma. The MAE and HS-SPME parameters were studied, and the method was validated. The optimal MAE conditions obtained were: microwave power of 700 W and irradiation time of 4 min, and HS-SPME optimal conditions were: fiber coating of 100 microm PDMS, extraction temperature of 80 degrees C, extraction time of 20 min, stirring rate of 1,100 rpm, and salt concentration of 30% NaCl. The proposed method provided good precision (RSD less than 12%) and recoveries between 86% and 93%. The proposed method was applied to the determination of the three marker compounds in three species of Curcuma rhizomes (Curcuma wenyujin, Curcuma phaeocaulis, and Curcuma kwangsiensis). To demonstrate the proposed method reliability, a conventional technique of steam distillation was also used for the analysis of curcumol, germacrone and curdione in the TCMs. The results show that MAE-HS-SPME is a simple, rapid, solvent-free and reliable method for the determination of curdione, curcumol and germacrone in TCM, and also a potential and powerful tool for quality assessment of Rhizoma Curcuma.

Curcuma↗

Quantification of 31 volatile organic compounds in whole blood using solid-phase microextraction and gas chromatography-mass spectrometry.

The prevalence of exposure to volatile organic compounds (VOCs) has raised concern about possible health effects resulting from chronic human exposure. To support studies exploring the relation between VOC exposure and health effects, we developed an automated analytical method using solid-phase microextraction (SPME), capillary gas chromatography (GC), and quadrupole mass spectrometry (MS). This method quantifies trace levels (low parts per trillion) of 14 halogenated alkanes, 5 halogenated alkenes, 10 aromatic compounds, and 2 other VOCs in human blood. Detection limits for the SPME-GC-MS method range from 0.005 to 0.12 microg/L, with linear calibration curves spanning three orders of magnitude. The improved throughput of this method will enable us to expand biomonitoring efforts to assess nonoccupational VOC exposure in large epidemiological studies.

Gas Chromatography-Mass Spectrometry↗

Trace determination of volatile sulfur compounds by solid-phase microextraction and GC-MS.

A method was developed for the simultaneous determination of the following nine volatile sulfur compounds in gas samples: carbon disulfide, carbonyl sulfide, ethyl sulfide, ethyl methyl sulfide, hydrogen sulfide, isopropanethiol, methanethiol, methyl disulfide and methyl sulfide. The target compounds were preconcentrated by solid-phase microextraction (SPME) and determined by gas chromatography combined with mass spectrometry. Experimental design was employed to optimize the extraction time and temperature and concurrent detection of the nine compounds was achieved by using an SPME fiber coated with Carboxen-polydimethylsiloxane (75 microns). Detection limits ranged from 1 ppt (v/v) for carbon disulfide to 350 ppt (v/v) for hydrogen sulfide and calibration functions were linear up to 20 ppb (v/v) for all the compounds investigated.

Gas Chromatography-Mass Spectrometry↗

Solid-phase microextraction for the evaluation of partition coefficients of a chlorinated dioxin and hexachlorobenzene into humic substances.

We developed a method for the evaluation of the partition coefficients (K(oc)) of hexachlorobenzene (HCB) and 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin (HpCDD) into humic substances (HSs) by using solid-phase microextraction (SPME). In the aqueous solution containing HCB or HpCDD and HS, the unbound species of HCB or HpCDD were accumulated on the SPME fiber. Subsequently, HCB or HpCDD on the SPME fiber was directly analyzed by GC-ECD. When the concentration of organic carbon in HS ([OC]) was plotted against the ratio of [HCB] or [HpCDD] in the absence of HS to that in the presence of HS, linear relationships were observed. The slope of the line corresponded to the K(oc) value. The log K(oc) values for HCB and HpCDD evaluated were in the ranges of 3.9 - 4.9 and 5.9 - 7.2, respectively. These values were the same order as those in the literature, which were evaluated by other methods (e.g., solubility enhancement, solid-phase extraction and dialysis). The relative standard deviations of the log K(oc) values evaluated in this study were within 5%.

Journal Article↗

Determination of urinary acylcarnitines by ESI-MS coupled with solid-phase microextraction (SPME).

The determination of selected short-, medium- and long-chain acylcarnitines by electrospray ionization mass spectrometry (ESI-MS) is discussed. The differences in fragmentation behaviour and ionization efficiency are described in dependence on collision induced dissociation (CID) conditions and mixture composition. A new method combination, solid-phase microextraction (SPME)-ESI-MS, is introduced to characterize acylcarnitines in body fluids. This method utilizes SPME for pre-concentration of acylcarnitines from complex biological samples and ESI-MS for a selective and sensitive detection. The method is presented by standard experiments determining of acylcarnitines in aqueous solutions and urine samples from patients with secondary carnitine deficiency syndromes or related disorders.

Calibration↗

Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection.

A simple procedure for the determination of methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), ethyl butyl ether (EBE), tert-amyl methyl ether (TAME), benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using headspace (HS) solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with flame ionization detector (FID) and 100% dimethylpolysiloxane fused capillary column. A 2 Plackett-Burman design for screening and a central composite design (CCD) for optimizing the significant variables were applied. Fiber type, extraction temperature, sodium chloride concentration, and headspace volume were the significant variables. A 65 microm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 10 degrees C, 300 g/l, and 20 ml of headspace (in 40 ml vial) were respectively chosen for the best extraction response. An extraction time of 10 min was enough to extract the ethers and BTEX. The relative standard deviation (R.S.D.) for the procedure varied from 2.6 (benzene) to 8.5% (ethylbenzene). The method detection limits (MDLs) found were from 0.02 (toluene, ethylbenzene, and xylenes) to 1.1 microg/l (MTBE). The optimized method was applied to the analysis of the rivers, marinas and fishing harbors surface waters from Gipuzkoa (North Spain). Three sampling were done in 1 year from June 2002 to June 2003. Toluene was the most detected analyte (in 90% of the samples analyzed), with an average concentration of 0.56 microg/l. MTBE was the only dialkyl ether detected (in 15% of the samples) showing two high levels over 400 microg/l that were related to accidental fuel spill.

Chromatography, Gas↗

Optimisation of a solid-phase microextraction method for the determination of parabens in water samples at the low ng per litre level.

A procedure for the determination of five esters of p-hydroxybenzoic acid (parabens) in water samples is presented. Analytes (methyl, ethyl, propyl, butyl and benzyl paraben) are concentrated on a solid-phase microextraction (SPME) fibre, converted on their tert-butyldimethylsilyl derivatives and selectively determined using gas chromatography in combination with tandem mass spectrometry (GC-MS/MS). Influence of different factors on the efficiency of extraction and on-fibre derivatization steps is described in detail. For all species, the highest enrichment factors were achieved using a polyacrylate (PA) fibre exposed directly to stirred water samples, containing 150 mg/ml of sodium chloride, at room temperature. Performance of the further on-fibre derivatization reaction was also maximum at room temperature, considering a short exposition period of the SPME fibre to vapours of the silylation reagent. Under optimised conditions, the proposed method achieved quantification limits from 0.001 to 0.025 ng/ml and it was free of matrix effects; therefore, external calibration can be used as the quantification technique. From our knowledge, this work describes the first application of SPME and gas chromatography to the determination of parabens in water. The analysis of a limited number of real samples revealed the presence of parabens in raw sewage water at concentrations up to 3 ng/ml.

Calibration↗

Headspace solid phase microextraction for the gas chromatographic analysis of methyl-parathion in post-mortem human samples. Application in a suicide case by intravenous injection.

A simple and rapid procedure for the determination of methyl-parathion (m-p) in post-mortem biological samples was developed using headspace solid phase microextraction (SPME) and gas chromatography (GC) with nitrogen-phosphorous detection (NPD). Methyl-parathion was extracted on 85 microm polyacrylate SPME fiber. Salt addition, extraction temperature, and extraction time were optimized to enhance the sensitivity of the method. The linearity (y = 0.0473x - 0.0113, R2 = 0.9992) and the dynamic range (0.1-40 microg/ml) were found very satisfactory. The recoveries of methyl-parathion were found to be 46% in spiked human whole blood, 53% in spiked homogenized liver tissue, and 54% in spiked homogenized kidney tissue compared with samples prepared in water. The coefficients of variations for 2, 4, and 20 microg/ml of methyl-parathion in blood ranged from 0.9 to 5.1%, whereas the detection limit of the method was satisfactory (1 ng/ml in aqueous samples, 50 ng/ml in whole blood). The developed procedure was applied to post-mortem biological samples from a 21-year-old woman fatally poisoned (suicide) by intravenous injection of methyl-parathion. The intact insecticide was found in the post-mortem blood at a concentration of 24 microg/ml. No methyl-parathion was detected in the liver, kidneys, and gastric contents.

Adult↗

Validation of a solid-phase microextraction method for the determination of organophosphorus pesticides in fruits and fruit juice.

A method for the determination of organophosphorus pesticides (diazinon, fenitrothion, fenthion, quinalphos, triazophos, phosalon and pyrazophos) in fruit (pears) and fruit juice samples was developed and validated. The samples were diluted with water, extracted by solid-phase microextraction (SPME) and analysed by gas chromatography (GC) using a flame photometric detector in phosphorous mode. Limits of detection of the method for fruit and fruit juice matrices were below 2 micrograms/kg for all pesticides. Relative standard deviations for triplicate analyses of samples fortified at 25 micrograms/kg of each pesticide were not higher than 8.7%. Recovery tests were performed for concentrations between 25 and 250 micrograms/kg. Mean recoveries for each pesticide were all above 75.9% and below 102.6% for juice, and between 70 and 99% for fruit except for pyrazophos in the fruit sample (with mean recovery of 53%). Therefore, the proposed method is applicable in the analysis of pesticides in fruit matrices and the use of the method in routine analysis of pesticide residues is discussed.

Artifacts↗

Determination of selected monohydroxy metabolites of 2-, 3- and 4-ring polycyclic aromatic hydrocarbons in urine by solid-phase microextraction and isotope dilution gas chromatography-mass spectrometry.

Eighteen monohydroxy polycyclic aromatic hydrocarbon metabolites (OH-PAHs) representing polycyclic aromatic hydrocarbons (PAHs) containing up to four rings in human urine have been measured. The method includes the addition of carbon-13 labeled internal standards, enzymatic hydrolysis, and solid-phase microextraction followed by gas chromatography with high-resolution mass spectrometry. By using response factors calculated with the carbon-13 labeled standards, results are presented for calibration, relative standard deviations and analyte levels from an unspiked human urine pool. The method detection limits ranged from 0.78 ng/l for hydroxyphenanthrenes to 15.8 ng/l for 1-hydroxynaphthalene, and the recoveries ranged between 6% for hydroxychrysene and 47% for 1-hydroxypyrene. The relative standard deviation was lowest for 3-hydroxyphenanthrene at 2.4% and went up to 18.7% for 6-hydroxychrysene. The method was calibrated from 10 to 1200 ng/l. Eleven of the 18 metabolites were found in background pooled urine samples. This validated method is a convenient and reliable tool for determining urinary OH-PAHs as biomarkers of exposure to eight PAHs.

Calibration↗

Analysis of 2-methylisoborneol and geosmin in catfish by microwave distillation--solid-phase microextraction.

The semivolatile cyclic alcohols 2-methylisoborneol (MIB) and geosmin (GSM) impart muddy or musty flavors to water and food products. A rapid quantitative analytical technique has been developed whereby microwave distillation is used to remove the volatile organic compounds from a lipophilic matrix into an aqueous matrix. Solid-phase microextraction (MD-SPME) is then used to extract and concentrate the analytes, which are then desorbed in the injection port of a gas chromatograph/mass spectrometer (GC/MS) for analysis. Limits of detection are 0.01 microg/kg and limits of quantification are 0.1 microg/kg. MD-SPME is comparable in precision, requires no solvents, and is faster than current methods of analysis. This methodology allows detection of MIB and GSM at concentrations below human sensory thresholds in fish tissue.

Animals↗

Rapid analysis of halothane in biological samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry--a case of a double homicide.

A simple, rapid, and sensitive method for the analysis of halothane in biological samples was developed. The procedure describes the extraction of halothane from blood, liver, kidney, brain, urine, bile, and stomach contents by headspace solid-phase microextraction (HS-SPME) followed by capillary gas chromatography coupled with mass spectrometry (GC-MS). The recovery in blood samples after addition of ammonium sulfate and sulfuric acid was 72% compared to a sample prepared in water (100%). Linearity was established over a concentration range of 0.1-100 mg/kg of spiked blood samples with an excellent coefficient of correlation (0.996) and a limit of detection of 0.004 mg/kg. The time for analysis was approximately 40 min per sample including the extraction step. The procedure was used for quantitation of halothane in various samples in a case of a double homicide. HS-SPME in combination with GC-MS was an effective method for the determination and quantitation of halothane in biological material.

Aged↗

Solid phase microextraction ion mobility spectrometer interface for explosive and taggant detection.

Ion mobility spectrometry (IMS) is a rugged, inexpensive, sensitive, field portable technique for the detection of organic compounds. It is widely employed in ports of entry and by the military as a particle detector for explosives and drugs of abuse. Solid phase microextraction (SPME) is an effective extraction technique that has been successfully employed in the field for the pre-concentration of a variety of compounds. Many organic high explosives do not have a high enough vapor pressure for effective vapor sampling. However, these explosives and their commercial explosive mixtures have characteristic volatile components detectable in their headspace. In addition, taggants are added to explosives to aid in detection through headspace sampling. SPME can easily extract these compounds from the headspace for IMS vapor detection. An interface that couples SPME to IMS was constructed and evaluated for the detection of the following detection taggants: 2-nitrotoluene (2-NT), 4-nitrotoluene (4-NT), and 2,3-dimethyl-2,3-dinitrobutane (DMNB). The interface was also evaluated for the following common explosives: smokeless powder (nitrocellulose, NC), 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT), 2,4,6-trinitrotoluene (2,4,6-TNT), hexahydro-1,3,5-trinitro-s-triazine (RDX), and pentaerythritol tetranitrate (PETN). This is the first peer reviewed report of a SPME-IMS system that is shown to extract volatile constituent chemicals and detection taggants in explosives from a headspace for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.

Butanes↗