PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “VEINS, FEMORAL”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Rat femoral vein-to-vein grafts as a microvascular practice model: factors that influence patency.

The rat femoral vein has become a standard model for microvascular anastomosis practice as well as for research investigations into various manipulative influences upon venous patency. Although vein grafts to the rat artery are the focus of many experimental studies, few reports have investigated vein-to-vein grafts. This study examines the short-term patency (1-3 days) of vein grafts interpositioned to the rat femoral vein. Several factors are studied for their ability to alter the patency rate. The results indicate that patency is difficult to achieve following the creation of a second serial anastomosis (construction of a vein-to-vein graft). Systemic heparin consistently improves patency rates, and trends toward increased patency are seen for reduction in longitudinal tension of the repaired vessel. It is also implied that a deeper understanding of venous hemodynamics and thrombotic events may lead to improved methodologies in the clinical applications of microvenous repairs. These results indicate that rat vein-to-vein grafts may provide a challenging microvascular training model, while introducing the novice microsurgeon to some of the complicating factors encountered with microvascular grafting.

Anastomosis, Surgical↗

Atrial natriuretic factor in cirrhosis with ascites: plasma levels, cardiac release and splanchnic extraction.

The aim of this study was to determine the plasma levels, cardiac release and splanchnic extraction of atrial natriuretic factor in cirrhosis with ascites. The plasma concentration of immunoreactive atrial natriuretic factor in samples obtained from an antecubital vein was measured in 18 healthy volunteers and in 35 cirrhotics with ascites. In 11 of these cirrhotics and in 11 patients admitted to the hospital for the study of a thoracic pain who had no clinical or hemodynamic signs of cardiac failure (control group), the plasma levels of immunoreactive atrial natriuretic factor in samples from the coronary sinus, right atrium, pulmonary artery, hepatic vein and femoral vein were determined and the coronary sinus blood flow measured by thermodilution. Cirrhotic patients showed significantly higher plasma levels of immunoreactive atrial natriuretic factor in each vascular territory studied than did control subjects (coronary sinus: 101.2 +/- 10.6 vs. 26.1 +/- 4.7 fmoles per ml; right atrium: 32.5 +/- 5.8 vs. 9.4 +/- 3.5; pulmonary artery: 36.8 +/- 10.1 vs. 7.5 +/- 2.4; hepatic vein: 10.7 +/- 2.0 vs. 2.7 +/- 0.8; femoral vein: 18.2 +/- 2.4 vs. 3.1 +/- 0.9; antecubital vein: 14.7 +/- 1.6 vs. 4.0 +/- 0.8). The coronary sinus blood flow was also higher in cirrhotics (200 + 22 ml per min) than in controls (105 +/- 7 ml per min). Consequently, the estimated cardiac release and cardiac production of immunoreactive atrial natriuretic factor were strikingly increased in cirrhotics (13,334 +/- 2,007 and 5,484 +/- 1,734 fmoles per min, respectively) as compared to control subjects (1,669 +/- 338 and 1,431 +/- 350 fmoles per min, respectively; p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Ascites↗

Improved patient survival after cardiac arrest using a cardiopulmonary support system.

A portable cardiopulmonary bypass system that can be rapidly deployed in a nonsurgical setting using nursing staff was used in 38 patients with cardiovascular collapse refractory to ACLS protocol. Percutaneous or cutdown cannulation sites were: femoral vein-femoral artery (n = 18), right internal jugular vein-femoral artery (n = 2), right atrium-ascending aorta (n = 12), or a combination approach (n = 4). Two patients could not be cannulated. Patient diagnoses were pulmonary emboli (n = 3), failed coronary angioplasty (n = 7), myocardial infarction with cardiogenic shock (n = 5), trauma (n = 7), aortic stenosis (n = 2), postcardiotomy deterioration (n = 10), deterioration after cardiac transplantation (n = 2), cardiomyopathy with shock (n = 1), and ruptured ascending aortic dissection (n = 1). Ninety-five percent of patients (36 of 38) were successfully resuscitated to a stable rhythm. Eight diagnostic procedures (coronary angiography, n = 4; pulmonary angiography, n = 3; and aortography, n = 1) were performed while patients were on cardiopulmonary support. Early deaths resulted from massive hemorrhage (n = 8), inability to cannulate (n = 2), and irreversible myocardial injury (n = 10). Sixty-six percent (24 of 36) of patients successfully cannulated underwent conversion to standard cardiopulmonary bypass with attendant operative procedure or placement of ventricular assist device or total artificial heart. Fifty percent (18 of 36) of patients cannulated were successfully weaned from cardiopulmonary support, and 17% (6/36) are long-term survivors.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Femoral artery flow in deep vein thrombosis: hemodynamics of slow versus acute femoral vein occlusion.

There are many reports of reduced flow in the femoral artery following acute occlusion of the femoral vein. Poorer results might also be expected in arterial reconstructive surgery for obliterative vascular disease, in the event of deep vein thrombosis (DVT) of the limb. It is likely that patients develop DVT by a slow process that is totally different from experimental acute occlusion of the femoral vein, which leads to reduction of flow in the femoral artery. To test this hypothesis, a model with slow and gradual femoral vein occlusion was used. The results of this study showed that there was only 13.5% reduction in femoral artery flow during a four-hour gradual occlusion of the femoral vein. This excludes the possibility that in the presence of gradually occurring processes such as DVT, there is a hemodynamic basis for reduced flow through the femoral artery or through a bypass.

Animals↗

Utility of lower-extremity duplex sonography in patients with venous thromboembolism.

PURPOSE: We evaluated the utility of venous duplex ultrasonography (VDUS) of the lower extremities in patients with pulmonary embolism (PE) and studied the distribution of venous thrombi in deep vein thrombosis (DVT) patients with and without PE. METHODS: We retrospectively reviewed medical records of all inpatients with a final diagnosis of PE or DVT between 1989 and 2000. RESULTS: Venous thrombosis was detected by VDUS in 229 patients (191 without PE and 38 with PE). The left leg only was involved in 50% of patients (p < 0.05), the right leg only in 33%, and both legs in 17%. The overall distribution of veins affected by DVT was: popliteal vein, 77%; superficial femoral vein, 76%; common femoral vein, 65%; posterior tibial vein, 23%; external iliac vein, 21%; common iliac vein, 9%; great saphenous vein, 7%; and inferior vena cava, 2%. A single venous site was involved in 22% of patients. External iliac vein thrombosis was more frequent in patients with DVT only (24%) than with PE and DVT (5%) (p < 0.05). The venous obstruction was partial in 14% of patients. VDUS of the asymptomatic leg was positive in 14% of patients with unilateral symptoms of DVT, all of whom also had DVT in the symptomatic leg. VDUS was positive for DVT in 90% of patients with PE and concomitant pain or edema of the leg, compared to only 20% of PE patients with no symptoms of DVT. CONCLUSIONS: Sonography should be the first diagnostic test for patients suspected of having PE with any sign or symptom related to DVT. VDUS of the asymptomatic leg is unnecessary in the diagnosis and management of DVT. Omitting the superficial femoral vein examination would lead to some decrease in the sensitivity of VDUS.

Adult↗

Complications of central venous catheterization in critically ill children.

OBJECTIVE: Analysis of central venous catheterization complications in different access sites with the Seldinger technique. Patients and Methods: A prospective study (May 1992 through December 1996) of 308 central venous catheterizations in children of different ages in a pediatric intensive care unit. RESULTS: Access sites were the subclavian vein (76.3%), femoral vein (20.4%), and jugular vein (3.2%). The frequency of catheter placement-related complications was 22%, and the frequency of serious catheter placement-related complications was 2.9% (pneumothorax 1.9%, hemothorax 1%). Catheter placement-related complications were more common in the subclavian than in the femoral vein (chi-square, p =.02) for the larger bore catheters (chi-square, p =.01) and for the higher number of attempts (Student's t -test, p <.001). Catheter placement-related complications were not related to the age, weight, or whether the procedure was performed by the staff physician or resident. The overall complication rate for maintenance-related complications was 36%. Maintenance-related complications were more common in younger children (Student's t -test, p =.03). The most frequent maintenance-related complications were mechanical complications (catheter obstruction and central venous thrombosis), and these were higher for femoral access (chi-square, p <.01) and for catheters indwelling for a longer period of time. Infection was found in 5.8% of patients, mainly due to Staphylococcus epidermidis. Infection was not related to the site of venous access or to the length of time the catheter was left indwelling. CONCLUSIONS: Central venous catheterization can be performed readily in children of all ages with an acceptable degree of risk. The immediate complications were more frequent and severe for subclavian vein catheterization, and the highest risk factor was the number of attempts at catheter insertion. Although the most frequent late complications were mechanical, which were higher for the femoral access and long-indwelling catheters, femoral catheters can be left indwelling for longer periods if routine ultrasound follow-up is performed. Infectious complications were independent of the venous access site or the duration of catheterization.

Journal Article↗

Anomalies encountered during varicose vein surgery.

During 5,050 stripping operations for varicose veins, three noticeable deviations from the normal anatomy were encountered. In two patients (0.04%) the long saphenous vein entered the femoral vein completely separate from its branches, which joined to form a common trunk before emptying into the femoral vein. In one patient (0.02%), the femoral vein and artery were transposed in the region of the fossa ovalis. In one patient (0.02%), a long saphenous artery was encountered. It arose from the femoral artery just proximal to the origin of the deep femoral artery and accompanied the long saphenous vein along the medial aspect of the upper thigh. In some patients, a large venous cluster overlying the fossa ovalis was encountered, usually the result of a congenital venous anomaly. Surgical problems can be minimized if the possibility of these congenital anomalies is always considered.

Arteriovenous Malformations↗

Anomalies encountered during varicose vein surgery.

During 5,050 stripping operations for varicose veins, three noticeable deviations from the normal anatomy were encountered. In two patients (0,04%) the long saphenous vein entered the femoral vein completely separate from its branches, which joined to form a common trunk before emptying into the femoral vein. In one patient (0,02%), the femoral vein and artery were transposed in the region of the fossa ovalis. In one patient (0,02%), a long saphenous artery was encountered. It arose from the femoral artery just proximal to the origin of the deep femoral artery and accompanied the long saphenous vein along the medial aspect of the upper thigh. In some patients, a large venous cluster overlying the fossa ovalis was encountered, usually the result of a congenital venous anomaly. Surgical problems can be minimized if the possibility of these congenital anomalies is always considered.

Femoral Artery↗

End-to-end versus end-to-side microvascular anastomosis patency in experimental venous repairs.

In this experimental study, venous end-to-end and end-to-side microvascular anastomoses in similar and diameter-discrepant vessels were compared. In 50 rats, end-to-end microvascular repair of the divided epigastric vein and end-to-side repair of the epigastric vein into the femoral vein showed 5-day patency rates of 75 and 88 percent, respectively. These data are not statistically different. In 20 rats, microvascular repair of end epigastric to end femoral veins (size discrepant) and end epigastric to side femoral veins showed 5-day patency rates of 50 and 85 percent, respectively. These data are statistically different (p less than 0.05). We conclude from these experimental data that end-to-side venous repairs may be useful in lowering the anastomosis thrombosis rate seen when size-discrepant veins are repaired.

Animals↗

Pressure gradients and transport in the murine femur upon hindlimb suspension.

Interstitial fluid flow (IFF) is important in a number of processes, including stimulation of cells and nutrient and waste transport. In bone, it arises from the vascular pressure gradient between the medullary cavity and the lymphatic drainage at the periosteal surface and is enhanced by mechanical loading events. However, little is known about the pressure gradients experienced by bone cells in vivo and the role of the induced IFF in bone adaptation. This study investigated IFF changes in bone, in a disuse model and in ambulatory mice, from pressure gradients measured by telemetry, and by fluorescent tracers. The role of IFF-mediated transport of oxygen was assessed by the levels of hypoxic osteocytes in mouse femur after disuse by hindlimb suspension and with or without femoral vein ligation. Femoral intramedullary pressures in alert mice decreased to 77% upon hindlimb suspension and increased by 25% upon ligation, relative to baseline. To determine relative perfusion of cortical bone by IFF, the localization of intracardiac-injected fluorescent albumin conjugate with osteocytes was monitored. The number of osteocytic lacunae per bone area positive for Texas Red albumin was increased by 31% within 20-40 s, in the ligated femur compared to the contralateral sham femur. This confirmed that interstitial fluid flow was increased by femoral vein ligation and indicated that the increase was proportional to the pressure increase. Unloaded bone osteocytes were not hypoxic when compared to loaded controls and venous ligation did not alter these levels significantly. These results support the hypothesis that disuse by hindlimb suspension leads to decreased pressure gradients, which indicate lower IFF. Similarly, the increased pressure gradients, seen upon venous ligation, increased IFF from marrow to periosteum. While a decrease in intramedullary pressure in disuse suggests a decrease in IFF, this did not lead to hypoxia in osteocytes. We conclude that decreased oxygen convective transport in the mouse hindlimb disuse model does not account for cortical bone loss. This study is important in increasing our understanding of the mechanotransductory pathways involved in bone loading and unloading.

Animals↗

Percutaneous placement of the Greenfield vena caval filter.

During the period from August 1986 to August 1987, 50 patients underwent percutaneous placement of a Greenfield vena caval filter from the right femoral vein, left femoral vein, or right internal jugular vein at our institution. All 50 patients had a contraindication to anticoagulation therapy or had complications of anticoagulation for deep venous thrombosis or pulmonary emboli. The percutaneous placement was accomplished in the angiographic suite with use of local anesthesia and was well tolerated by all patients. Only three complications related to the percutaneous approach occurred during the short-term follow-up (3 months to 1 year). These complications were deep venous thrombosis of the leg in two patients and misplacement of the filter in one patient. The three patients tolerated these complications well. We conclude that placement of Greenfield vena caval filters can be readily accomplished by means of percutaneous entry. Our experience demonstrated minimal associated morbidity and no mortality.

Aged↗

Composite valve graft replacement of the ascending aorta and the aortic valve by a modified button technique: the influence of aortic pathology on early mortality and late survival.

The risk factors for in-hospital mortality and mid-term survival in patients undergoing composite graft replacement of the aortic root with reimplant or coronary arteries by a modified button technique were evaluated with special emphasis on the underlying aortic pathology. Between 1985 and 1993 74 patients underwent replacement of the ascending aorta and the aortic valve following a modified button technique. The patients were divided into three groups according to aortic pathology: annuloaortic ectasia (43.58%), type A dissection (18.24%), and miscellaneous (13.18%). In-hospital mortality rates were 4.7%, 33.3% and 23.1%, respectively (P = 0.011). Univariate analysis showed that aortic pathology, NYHA class, emergency operation, redo operation, acute aortic dissection, preoperative cardiogenic shock, preoperative cardiac tamponade, longer cardiopulmonary bypass (CPB) and aortic cross-clamp times, and the need of femoral vein or femoral artery cannulation at intervention had univariate influence on in-hospital mortality. Multivariable stepwise logistic regression analysis identified CPB time odds ratio (OR) = 1.021/min, P = 0.007), the need of femoral vein cannulation at intervention (OR= 4.85, P = 0.008) and preoperative cardiac tamponade (OR = 3.11, P = 0.07) as independent predictors of in-hospital death. Follow-up ranged from 1 to 98 months (mean 39 +/- 30 months) with an actuarial survival rate of 75 +/- 9%, 52 +/- 13% and 67 +/- 14% at 5 years in annuloaortic ectasia, type A dissection, and miscellaneous patients, respectively (P = 0.18); when survival was evaluated in hospital survivors only, Kaplan-Meier survival rates were 77 +/- 9%, 79 +/- 14% and 89 +/- 10% at 5 years (P = 0.87). Comparing survival of annuloaortic ectasia patients (5-year survival 75 +/- 9%) versus survival of all other patients pooled together (5-year survival 55 +/- 11%), there was a statistically significant difference (P < 0.05); such a difference was no longer significant when comparing hospital survivors alone (5-year survival rate 77 +/- 9% annuloaortic ectasia patients vs 79 +/- 12% all other patients P = 0.61). Although aortic root replacement carries higher in-hospital mortality in some high-risk subgroups of patients, mid-term survival seems to be less affected by aortic pathology; high-risk patients are expected to have an out-hospital outcome comparable to the low-risk ones.

Aortic Dissection↗

Continuous venovenous hemofiltration improves arterial oxygenation in endotoxin-induced lung injury in pigs.

BACKGROUND: Hypoxemia is common in septic acute lung failure. Therapy is mainly supportive, and most trials using specific inhibitors of key inflammatory mediators (ie., tumor necrosis factor alpha, interleukin 1) have failed to prove beneficial. The authors investigated if a nonspecific blood purification technique, using zero-balanced high-volume continuous venovenous hemofiltration (CWH), might improve arterial oxygenation in a fluid-resuscitated porcine model of endotoxin-induced acute lung injury. METHODS: Piglets of both sexes weighing 25-30 kg were anesthetized and mechanically ventilated. After baseline measurements, animals received an intravenous infusion of 0.5 mg/kg endotoxin (Escherichia coli lipopolysaccharide). One hour after endotoxin, animals were randomly assigned to either treatment with CWH (endotoxin + hemofiltration, n = 6) or spontaneous course (endotoxin, n = 6). At 4 h after randomization, animals were killed. Hemofiltration was performed from femoral vein to femoral vein using a standard circuit with an EF60 polysulphone hemofilter. RESULTS: Endotoxin challenge induced arterial hypoxemia, an increase in peak inspiratory pressure, pulmonary hypertension, and systemic hypotension. Treatment with CWH did not improve systemic or pulmonary hemodynamics. However, arterial oxygenation was increased in endotoxin-challenged animals at 5 h after completion of endotoxin infusion, as compared with animals not receiving CVVH (arterialoxygen tension, 268+/-33 vs. 176+/-67 mm/Hg, respectively, P < 0.01). In addition, treatment with CWH attenuated the endotoxin-induced increase in peak inspiratory pressure and increased lung compliance. CONCLUSION: These results suggest that nonspecific blood purification with high-volume CWH improves arterial oxygenation and lung function in endotoxin-induced acute lung injury in pigs, independent of improved hemodynamics, fluid removal, or body temperature.

Animals↗

Comparison of different methods for measuring intra-abdominal pressure.

OBJECTIVE: Intra-abdominal pressure (IAP) can be measured in different ways but is usually measured indirectly via the urinary bladder. The aim of the study was to: 1) compare urinary bladder pressure, femoral vein pressure, and inferior caval vein pressure with IAP at different levels of IAP; and 2) try to find an optimal amount of fluid to be instilled into the urinary bladder before measurement of the bladder pressure, and to compare changes in blood flow in the femoral vein with that in the caval vein at different pressure levels. DESIGN: Experimental study. SETTING: Animal research laboratory. SUBJECTS: Eight domestic swine of both sexes, weighing 30.6+/-2.9 kg (mean+/-SD). INTERVENTIONS: Catheters connected to pressure transducers were placed into the urinary bladder, the inferior caval vein, the femoral vein, and the superior caval vein. Transit time flow probes were placed around the inferior caval vein and the femoral vein. After a stabilizing period, the abdominal pressure was increased stepwise by instillation of Ringer's solution into the abdomen and then decreased. Thereafter, we instilled fluid into the bladder at an IAP of 8 mmHg and at 20 mmHg and measured the amount of fluid needed to elevate the intra-vesical pressure by 2 mmHg. RESULTS: The pressures recorded in the urinary bladder, the inferior caval vein, and the femoral vein reflected the pressure in the abdominal cavity very well. The fluid volume needed to increase the bladder pressure by 2 mmHg was significantly lower at 20 mmHg IAP than at 8 mmHg. Blood flow in the femoral vein and the inferior caval vein showed a similar pattern and decreased when the intra-abdominal pressure increased. CONCLUSIONS: In our porcine model, and increasing the IAP by means of instillation of Ringer's solution, a reliable estimation of the IAP was obtained by measuring the pressure in the urinary bladder, the femoral vein or the inferior caval vein. The IAP estimated indirectly as the urinary bladder pressure is affected by the amount of fluid in the bladder, which should not exceed 10-15 ml. The decrease in femoral vein blood flow reflects the changes in inferior caval vein flow during increased IAP.

Abdomen↗

Lengthening the greater saphenous vein with the use of the lateral femoral cutaneous vein.

Besides quality, the length of the greater saphenous vein dictates the feasibility of vein bypass grafts in femorodistal popliteal or tibial revascularization. A simple and effective technique of lengthening the greater saphenous vein is described that allows the use of the laterofemoral cutaneous vein in continuity. This technique can be applied when the distal segment of the greater saphenous vein is inadequate or unavailable.

Aged↗

Pharmacokinetics of mitomycin C following hepatic arterial chemoembolization with gelfoam.

Twelve mongrel dogs were randomly allocated into two groups using matched paired-design. Catheters were inserted into the hepatic artery, hepatic vein and the femoral vein, respectively. In the first group, gelfoam supplemented with mitomycin C (MMC) was injected into the hepatic artery, whereas the second group received a hepatic arterial injection of MMC solution alone. Simultaneous blood sampling from the hepatic and femoral vein at regular intervals was performed. MMC concentrations in plasma was determined using high performance liquid chromatography (HPLC) and the pharmacokinetics of MMC were determined. MMC concentrations in hepatic and femoral veins did not differ and no significant difference in pharmacokinetics was found when comparing MMC administration into the hepatic artery with or without gelfoam supplementation. Thus, our results revealed that gelfoam could not delay the clearance of MMC from the liver.

Animals↗

Superficial femoral popliteal vein: An anatomic study.

OBJECTIVE: The superficial femoral popliteal vein (SFPV) has been used as an alternative conduit for both arterial and venous reconstructive surgery. Its popularity continues to grow, despite concern about the potential for venous morbidity after harvest. The purpose of this study was to determine an anatomic "safe" length of SFPV for harvest, assuming that the preservation of at least one valve and one significant collateral vein in the remaining popliteal vein (PV) segment can minimize venous morbidity. METHODS: Forty-four SFPVs were harvested from 39 cadaveric specimens. The length of both the superficial femoral vein (SFV) and PV was measured, and the number and location of valves and significant side branches (more than 2 mm in diameter) of the PV were measured. The Student two-tailed t test was used as a means of comparing vein lengths between the sexes. Correlation coefficients were determined for the effect of patient height on vein length, stratified by means of sex. RESULTS: Vein length (SFV mean, 24.4 +/- 4 cm; PV mean, 18.8 +/- 4 cm) varied with sex (male SFV mean, 28.1 +/- 5 cm; male PV mean, 21. 5 +/- 3 cm; female SFV mean, 22.6 +/- 4 cm; female PV mean, 18.4 +/- 3 cm; P =.01). Valve number (mean, 1.8 +/- 0.5) and location and collateral vein number (mean, 5 +/- 1.8) and location were variable and independent of height or sex. CONCLUSION: An anatomic "safe" length of SFPV for harvest to minimize venous morbidity would include all the SFV and 12 cm of PV in 95% of women and 15 cm of PV in 95% of men. We found that the male sex was a significant determinant for a longer safe length of vein that can be harvested.

Cadaver↗

The effect of total hip replacement and general surgery on antithrombin III in relation to venous thrombosis.

This investigation was undertaken to identify and correlate one factor that makes patients undergoing total hip replacement more susceptible to venous thrombosis and pulmonary embolism than those who have almost any other elective orthopaedic procedure, and to determine why the operation of total hip replacement has proved to be relatively resistant to antithrombotic prophylaxis compared with general surgical procedures. Using the depletion of antithrombin III as a marker of activation of the coagulation system, two groups of patients were compared: twenty-one who were subjected to hip arthroplasty and fourteen who underwent general surgical procedures. Both during and after operation the decrease in the quantity of antithrombin III in hip-arthroplasty patients was significantly greater (p less than 0.05) than the decrease in general surgical patients. Seventy-three per cent of hip-replacement patients had venographic evidence of recent thrombosis, 60 per cent of which were discontinuous femoral-vein thrombi. Femoral-vein thrombosis occurs frequently in hip-arthroplasty patients and is relatively resistant to current antithrombotic prophylaxis. The data presented suggest that during hip surgery there is a strong systemic activation of the clotting cascade that is associated with local vessel injury and local stasis in the femoral vein, an association not found in most general surgical procedures.

Abdomen↗