PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Characterization of a new solvent-responsive gene locus in Pseudomonas putida F1 and its functionalization as a versatile biosensor.

A new gene cluster, designated sepABC and a divergently transcribed sepR, was found downstream of the two-component todST phosphorelay system that regulates toluene degradation (the tod pathway) in Pseudomonas putida F1 (PpF1). The deduced amino acid sequences encoded by sepABC show a high homology to bacterial proteins known to be involved in solvent efflux or multidrug pumps. SepA, SepB and SepC are referred to be periplasmic, inner membrane and outer membrane efflux proteins respectively. Effects on growth of various PpF1 mutants compared to that of the wild type in the presence of toluene indicated a possible protective role of the solvent efflux system in a solvent-stressed environment. Growth tests with the complemented mutants confirmed the involvement of the Sep proteins in conferring solvent tolerance. The sepR gene encodes a 260-residue polypeptide that is a member of the E. coli IclR repressor protein family. The repressor role of SepR was established by conducting tests with a sep-lacZ transcriptional fusion in Escherichia coli and PpF1, expression of SepR as a maltose-binding fusion protein in a DNA binding assay, and mRNA analysis. Southern hybridization experiments and analysis of the P. putida KT2440 genome sequence indicated that sepR is a relatively rare commodity compared to homologues of the sepABC genes. We developed a whole-cell bioluminescent biosensor, PpF1G4, which contains a chromosomally based sep-lux transcriptional fusion. The biosensor showed significant induction of the sepABC genes by a wide variety of aromatic molecules, including benzene, toluene, ethylbenzene, and all three isomers of xylene (BTEX), naphthalene, and complex mixtures of aliphatic and aromatic hydrocarbons. PpF1G4 represents a second-generation biosensor that is not based on a catabolic promoter but is nonetheless inducible by aromatic pollutants and moreover functional under nutrient-rich conditions.

Bacterial Proteins↗

A new green fluorescent protein-based bacterial biosensor for analysing phenanthrene fluxes.

The polycyclic aromatic hydrocarbon (PAH)-degrading strain Burkholderia sp. RP007 served as host strain for the design of a bacterial biosensor for the detection of phenanthrene. RP007 was transformed with a reporter plasmid containing a transcriptional fusion between the phnS putative promoter/operator region and the gene encoding the enhanced green fluorescent protein (GFP). The resulting bacterial biosensor--Burkholderia sp. strain RP037--produced significant amounts of GFP after batch incubation in the presence of phenanthrene crystals. Co-incubation with acetate did not disturb the phenanthrene-specific response but resulted in a homogenously responding population of cells. Active metabolism was required for induction with phenanthrene. The magnitude of GFP induction was influenced by physical parameters affecting the phenanthrene flux to the cells, such as the contact surface area between solid phenanthrene and the aqueous phase, addition of surfactant, and slow phenanthrene release from Model Polymer Release System beads or from a water-immiscible oil. These results strongly suggest that the bacterial biosensor can sense different phenanthrene fluxes while maintaining phenanthrene metabolism, thus acting as a genuine sensor for phenanthrene bioavailability. A relationship between GFP production and phenanthrene mass transfer is proposed.

Biodegradation, Environmental↗

Multichannel flow-injection-analysis biosensor system for on-line monitoring of glucose, lactate, glutamine, glutamate and ammonia in animal cell culture.

The application of a chemiluminometric method for the on-line monitoring of a hybridoma cell culture is described. Enzyme sensors for glucose, lactate, glutamine, glutamate and ammonia, based on oxidase-catalysed reactions, were developed and connected to a flow-injection-analysis (f.i.a.) biosensor. H2O2 produced by the oxidase-catalysed enzyme reaction was detected by luminol chemiluminescence with a fibre-optic H2O2 biosensor. The system has been used to monitor animal cell cultures. A continuous hybridoma cell cultivation for the production of monoclonal antibodies is presented as an example. It was possible to monitor the bioprocess over a period of 15 days. A complete analysis of all five components could be performed within 42 min. The enzyme sensors were stable during the whole cultivation time without significant loss of activity. The computer-controlled biosensor f.i.a. works with good reliability. The precision for all five components ranged between 2.2 and 4.5%. It was possible to determine glutamine in one step using an anti-interference enzyme reactor. Endogenous glutamate was completely removed up to a level of 0.5 mM.

Ammonia↗

Detection and quantification of tetracyclines by whole cell biosensors.

Three different mini-Tn5 plasmids, containing a tetracycline-inducible promoter, Ptet and a regulatory gene, tetR, in operon fusions with a reporter gene system (lacZYA, luxCDABE or gfp), were constructed. These biosensor constructs responded to low levels of tetracyclines by producing beta-galactosidase, light or green fluorescent protein. They did so in a quantitative manner, thus enabling the quantification of tetracyclines in the immediate surroundings of the biosensor organism. All three constructs were transferred successfully to different gram-negative bacteria by conjugation. An Escherichia coli strain containing the Ptet-lac construct was used to determine oxytetracycline in milk as a demonstration of the application of these biosensors.

Animals↗

Effects of propyl gallate on interaction between TNF-alpha and sTNFR-I using an affinity biosensor.

AIM: To study the effects of propyl gallate on the interaction of tumor necrosis factor-alpha (TNF-alpha) with its soluble receptor, sTNFR-I. METHODS: Interactions between TNF-alpha and sTNFR-I were analyzed using an IAsys biosensor. sTNFR-I was immobilized on the carboxymethyl dextran (CMD) surface of the IAsys biosensor cuvettes, and TNF-alpha preincubated with different concentrations of propyl gallate was added to the cuvettes. The resonant angle shift caused by the binding between TNF-alpha and sTNFR-I was then recorded. RESULTS: sTNFR-I was immobilized on the CMD surface at a density of 2.76 ng/mm(2). TNF-alpha then bound the immobilized sTNFR-I specifically, and propyl gallate was able to enhance the binding between TNF-alpha and sTNFR-I in a dose-dependent manner. CONCLUSION: The binding between TNF-alpha and sTNFR-I is one of the targets that propyl gallate can act on in vivo. The IAsys biosensor offers a new clue as to the study on the mechanisms of action of propyl gallate.

Antioxidants↗

Sensitivity and dynamics of bioreceptor-based biosensors.

Bioreceptors can provide the basis for specific and sensitive biosensors. There are many sources of bioreceptors in nature for biochemicals of interest in biotechnology and biomedicine. These bioreceptors (antibodies, enzymes, membrane proteins, binding proteins) can be modified and produced in large quantities using modern biotechnological techniques. The characteristics of the biosensor can also be fine-tuned by modifying the structure of the analog-analyte, which will also provide several orders of magnitude of range sensitivity with a given bioreceptor. The ultimate sensitivity of the biosensor may be limited by the dissociation kinetics of the reaction between analyte and bioreceptor because there is a trade-off between sensitivity and sensor response rate to changes in analyte concentration.

Antibodies↗

Monitoring signaling processes in living cells using biosensors.

This collection of nine animations shows how different types of biosensors report changes in cellular processes through the production of a visually detectable signal. Biosensors can be created by attaching one or more fluorescent proteins (such as green fluorescent protein) to a target protein or peptide or by attaching a fluorescent dye that is sensitive to its environment to a protein or peptide. Conformational changes in proteins in response to ligand binding, changes in the concentration of cellular metabolites or signaling messengers, changes in protein localization, and changes in protein activity or covalent modification can all be detected with biosensors. These animations can be used separately or together to illustrate how molecular biology, chemistry, and microscopy have converged to allow cellular processes to be visualized in living cells. Several of the animations describe the production of a fluorescent resonance energy transfer (FRET) signal.

Biosensing Techniques↗

In vivo detection and quantification of tetracycline by use of a whole-cell biosensor in the rat intestine.

An Escherichia coli biosensor strain, harboring the plasmid pTGFP2, was introduced into the gastrointestinal tract of gnotobiotic rats that continuously received drinking water containing tetracycline. Plasmid pTGFP2 contains a transcriptional fusion between a green fluorescent protein (GFP) gene and a tetracycline-regulated promoter and was shown to produce a proportional GFP signal in response to exposure to various tetracycline concentrations when harbored by an E. coli strain. The plasmid was highly unstable in the host bacteria colonizing the intestinal system of the animals, and rapid plasmid loss was observed. Reintroduction of the E. coli MC4100/pTGFP2 strain into animals already colonized by the plasmid-free E. coli strain the day before euthanasia made it possible to extract and analyze the biosensors from intestinal samples. The induction of GFP in the biosensor cells extracted from the animals was estimated on a single-cell basis by use of flow cytometry, and the mean induction of GFP in the samples was compared to a standard curve prepared from known tetracycline concentrations. The results showed that the bioavailable tetracycline concentration within the bacterial growth habitat of the intestine was proportional to the concentration of tetracycline in drinking water but represented only approximately 0.4% of the intake concentration. This is a significant finding which will help to clarify antimicrobial therapy in the intestinal environment.

Animals↗

Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium.

An optical whole-cell biosensor based on a genetically engineered bioluminescent catabolic reporter bacterium was developed for continuous on-line monitoring of naphthalene and salicylate bioavailability and microbial catabolic activity potential in waste streams. The bioluminescent reporter bacterium, Pseudomonas fluorescens HK44, carries a transcriptional nahG-luxCDABE fusion for naphthalene and salicylate catabolism. Exposure to either compound resulted in inducible bioluminescence. The reporter culture was immobilized onto the surface of an optical light guide by using strontium alginate. This biosensor probe was then inserted into a measurement cell which simultaneously received the waste stream solution and a maintenance medium. Exposure under defined conditions to both naphthalene and salicylate resulted in a rapid increase in bioluminescence. The magnitude of the response and the response time were concentration dependent. Good reproducibility of the response was observed during repetitive perturbations with either naphthalene or salicylate. Exposure to other compounds, such as glucose and complex nutrient medium or toluene, resulted in either minor bioluminescence increases after significantly longer response times compared with naphthalene or no response, respectively. The environmental utility of the biosensor was tested by using real pollutant mixtures. A specific bioluminescence response was obtained after exposure to either an aqueous solution saturated with JP-4 jet fuel or an aqueous leachate from a manufactured-gas plant soil, since naphthalene was present in both pollutant mixtures.

Base Sequence↗

Design and application of a biosensor for monitoring toxicity of compounds to eukaryotes.

Here we describe an alternative approach to currently used cytotoxicity analyses through applying eukaryotic microbial biosensors. The yeast Saccharomyces cerevisiae was genetically modified to express firefly luciferase, generating a bioluminescent yeast strain. The presence of any toxic chemical that interfered with the cells' metabolism resulted in a quantitative decrease in bioluminescence. In this study, it was demonstrated that the luminescent yeast strain senses chemicals known to be toxic to eukaryotes in samples assessed as nontoxic by prokaryotic biosensors. As the cell wall and adaptive mechanisms of S. cerevisiae cells enhance stability and protect from extremes of pH, solvent exposure, and osmotic shock, these inherent properties were exploited to generate a biosensor that should detect a wide range of both organic and inorganic toxins under extreme conditions.

2-Methyl-4-chlorophenoxyacetic Acid↗

Novel cyanobacterial biosensor for detection of herbicides.

The aim of this work was to generate a cyanobacterial biosensor that could be used to detect herbicides and other environmental pollutants. A representative freshwater cyanobacterium, Synechocystis sp. strain PCC6803, was chromosomally marked with the luciferase gene luc (from the firefly Photinus pyralis) to create a novel bioluminescent cyanobacterial strain. Successful expression of the luc gene during growth of Synechocystis sp. strain PCC6803 cultures was characterized by measuring optical density and bioluminescence. Bioluminescence was optimized with regard to uptake of the luciferase substrate, luciferin, and the physiology of the cyanobacterium. Bioassays demonstrated that a novel luminescent cyanobacterial biosensor has been developed which responded to a range of compounds including different herbicide types and other toxins. This biosensor is expected to provide new opportunities for the rapid screening of environmental samples or for the investigation of potential environmental damage.

Biosensing Techniques↗

Detection of Yersinia pestis fraction 1 antigen with a fiber optic biosensor.

A fiber optic biosensor was used to detect the fraction 1 (F1) antigen from Yersinia pestis, the etiologic agent of plague. The instrument employs an argon ion laser (514 nm) to launch light into a long-clad fiber and measures the fluorescence produced by an immunofluorescent complex formed in the evanescent wave region. This sensing area is a short section (12.5 cm) at the end of the optical fiber from which the cladding has been removed and in which the silica core has been tapered. Capture antibodies, which bind to F1 antigen, were immobilized on the core surface to form the basis of the sandwich fluoroimmunoassay. The ability to detect bound F1 antigen was provided by adding tetramethylrhodamine-labeled anti-plaque antibody to form fluorescent complexes. The evanescent wave has a limited penetration depth (< 1 lambda), which restricts detection of the fluorescent complexes bound to the fiber's surface. The direct correlation between the F1 antigen concentration and the signal provided an effective method for sample quantitation. This method achieved a high level of accuracy for determining F1 antigen concentrations from 50 to 400 ng/ml in phosphate-buffered saline, serum, plasma, and whole blood, with a 5-ng/ml limit of detection. Subsequent blind studies, which included serum samples from patients, yielded results in good agreement with measurements by enzyme-linked immunosorbent assay. A major advantage of the fiber optic biosensor is that results can be generated within minutes while isolating the user from hazardous samples. These factors favor development of this biosensor into a facile and rapid diagnostic device.

Animals↗

Biosensors in chemical separations.

Identification of biomolecules in complex biological mixtures represents a major challenge in biomedical, environmental, and chemical research today. Chemical separations with traditional detection schemes such as absorption, fluorescence, refractive index, conductivity, and electrochemistry have been the standards for definitive identifications of many compounds. In many instances, however, the complexity of the biomixture exceeds the resolution capability of chemical separations. Biosensors based on molecular recognition can dramatically improve the selectivity of and provide biologically relevant information about the components. This review describes how coupling chemical separations with online biosensors solves challenging problems in sample analysis by identifying components that would not normally be detectable by either technique alone. This review also presents examples and principles of combining chemical separations with biosensor detection that uses living systems, whole cells, membrane receptors, enzymes, and immunosensors.

Animals↗

Imaging endoplasmic reticulum calcium with a fluorescent biosensor in transgenic mice.

The use of biosynthetic fluorescent sensors is an important new approach for imaging Ca(2+) in cells. Genetically encoded indicators based on green fluorescent protein, calmodulin, and fluorescence resonance energy transfer (FRET) have been utilized to measure Ca(2+) in nonmammalian transgenic organisms and provide information about the organization and regulation of Ca(2+) signaling events in vivo. However, expression of biosynthetic FRET-based Ca(2+) indicators in transgenic mammals has proven to be problematic. Here, we report transgenic expression of an endoplasmic reticulum (ER) Ca(2+) biosensor in mouse pancreas. We targeted expression of a yellow cameleon3.3er (YC3.3er) transgene with mouse insulin I promoter. YC3.3er protein expression was limited to pancreatic beta-cells within islets of Langerhans and absent in the exocrine pancreas and other tissues. Animals developed and matured normally; sensor expression was unaffected by age. Glucose tolerance in transgenic mice was also unaffected, indicating the transgenic biosensor did not impair endocrine pancreas function. ER Ca(2+) responses after administration of thapsigargin, carbachol, and glucose were measured in individual beta-cells of intact islets using confocal microscopy and confirmed the function of the biosensor. We conclude that controlling transgene transcription with a cell-specific promoter permits transgenic expression of FRET-based Ca(2+) sensors in mammals and that this approach will facilitate real-time optical imaging of signal transduction events in living tissues.

Animals↗

Characterization of a set of HIV-1 protease inhibitors using binding kinetics data from a biosensor-based screen.

The interaction between 290 structurally diverse human immunodeficiency virus type 1 (HIV-1) protease inhibitors and the immobilized enzyme was analyzed with an optical biosensor. Although only a single concentration of inhibitor was used, information about the kinetics of the interaction could be obtained by extracting binding signals at discrete time points. The statistical correlation between the biosensor binding data, inhibition of enzyme activity (K(i)), and viral replication (EC(50)) revealed that the association and dissociation rates for the interaction could be resolved and that they were characteristic for the compounds. The most potent inhibitors, with respect to K(i) and EC(50) values, including the clinically used drugs, all exhibited fast association and slow dissociation rates. Selective or partially selective binders for HIV-1 protease could be distinguished from compounds that showed a general protein-binding tendency by using three reference target proteins. This biosensor-based direct binding assay revealed a capacity to efficiently provide high-resolution information on the interaction kinetics and specificity of the interaction of a set of compounds with several targets simultaneously.

Biosensing Techniques↗

Optical biosensor with dispersion compensation.

Dispersion limits performance in many optical systems. In surface plasmon resonance (SPR) biosensors, the sensing area is an optical element in which the dispersion depends on the effective refractive index of the biochemical compounds to be measured. We report a method of compensating for wavelength dispersion in SPR biosensors employing two integrated diffractive optical coupling elements in a polymer substrate. The dispersion compensation is achieved over the whole dynamic measurement range and provides a biosensor more robust to wavelength fluctuations than prism-coupler SPR systems. The concept can readily be employed in other types of sensor measuring refractive-index changes.

Algorithms↗

Fluorescent energy transfer readout of an aptazyme-based biosensor.

Biosensors are devices that amplify signals generated from the specific interaction between a receptor and an analyte of interest. RNA structural motifs called aptamers have recently been discovered as receptor components for biosensors owing to the ease with which they can be evolved in vitro to bind a variety of ligands with high specificity and affinity. By coupling an aptamer as allosteric control element to a catalytic RNA such as the hammerhead ribozyme, ligand binding is transduced into a catalytic event. We have made use of fluorescence resonance energy transfer (FRET) to further amplify ligand induced catalysis into an easily detectable fluorescence signal. This chapter reviews in detail the methods and protocols to prepare a theophylline specific aptazyme and to label its substrate with fluorophores. We also include detailed protocols to characterize by FRET the binding affinity of the target, theophylline, as well as the external substrate to the aptazyme. The chapter should therefore facilitate the implementation of RNA-based biosensor components for other analytes of interest.

Aptamers, Nucleotide↗

Analyte-receptor binding kinetics for different types of biosensors. A fractal analysis.

A fractal analysis is presented for analyte-receptor binding kinetics for different types of biosensor applications. Data taken from the literature may be modeled using a single-fractal analysis, a single- and a dual-fractal analysis, or a dual-fractal analysis. The latter two methods represent a change in the binding mechanism as the reaction progresses on the surface. Predictive relationships developed for the binding rate coefficient as a function of the analyte concentration are of particular value since they provide a means by which the binding rate coefficients may be manipulated. Relationships are presented for the binding rate coefficients as a function of the fractal dimension Df or the degree of heterogeneity that exists on the surface. When analyte-receptor binding is involved, an increase in the heterogeneity on the surface (increase in Df) leads to an increase in the binding rate coefficient. It is suggested that an increase in the degree of heterogeneity on the surface leads to an increase in the turbulence on the surface owing to the irregularities on the surface. This turbulence promotes mixing, minimizes diffusional limitations, and leads subsequently to an increase in the binding rate coefficient. The binding rate coefficient is rather sensitive to the degree of heterogeneity, Df, that exists on the biosensor surface. For example, the order of dependence on Df1 is 7.25 for the binding rate coefficient k1 for the binding of a Fab fragment of an antiparaquat monoclonal antibody in solution to an antigen in the form of a paraquat analog immobilized on a sensor surface. The predictive relationships presented for the binding rate coefficient and the fractal dimension as a function of the analyte concentration in solution provide further physical insights into the binding reactions on the surface, and should assist in enhancing biosensor performance. In general, the technique is applicable to other reactions occurring on different types of surfaces, such as cell-surface reactions.

Biosensing Techniques↗