PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “reflection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Measuring the porosity and the tortuosity of porous materials via reflected waves at oblique incidence.

An ultrasonic reflectivity method is proposed for measuring porosity and tortuosity of porous materials having a rigid frame. Porosity is the relative fraction by volume of the air contained within a material. Tortuosity is a geometrical parameter which intervenes in the description of the inertial effects between the fluid filled the porous material and its structure at high frequency range. It is generally easy to evaluate the tortuosity from transmitted waves, this is not the case for porosity because of its weak sensitivity in transmitted mode. The proposed method is based on measurement of reflected wave by the first interface of a slab of rigid porous material. This method is obtained from a temporal model of the direct and inverse scattering problems for the propagation of transient ultrasonic waves in a homogeneous isotropic slab of porous material having a rigid frame [Z. E. A. Fellah, M. Fellah, W. Lauriks, and C. Depollier, J. Acoust. Soc. Am. 113, 61 (2003)]. Reflection and transmission scattering operators for a slab of porous material are derived from the responses of the medium to an incident acoustic pulse at oblique incidence. The porosity and tortuosity are determined simultaneously from the measurements of reflected waves at two oblique incidence angles. Experimental and numerical validation results of this method are presented.

Journal Article↗

Determination of transport parameters in air-saturated porous materials via reflected ultrasonic waves.

An ultrasonic reflectivity method of evaluating the acoustic parameters of porous materials saturated by air (or any other gas) is discussed. The method is based on experimental detection of waves reflected at normal incidence by the first and second interface of the material. This method is based on a temporal model of direct and inverse scattering problems for the propagation of transient ultrasonic waves in a homogeneous isotropic slab of porous material with a rigid frame [Fellah et al., J. Acoust. Soc. Am. 113, 61-73 (2003)]. Generally, the conventional ultrasonic approach can be used to determine tortuosity, and viscous and thermal characteristic lengths via transmitted waves. Porosity cannot be estimated in transmitted mode because of its very weak sensitivity. First interface use of the reflected wave at oblique incidence leads to the determination of porosity and tortuosity [Fellah et al., J. Acoust. Soc. Am. 113, 2424-2433 (2003)] but this is not possible at normal incidence. Using experimental data of reflected waves by the first and second interface at normal incidence simultaneously leads to the determination of porosity, tortuosity, viscous and thermal characteristic lengths. As with the classic ultrasonic approach for characterizing porous material saturated with one gas, both characteristic lengths are estimated individually by assuming a given ratio between them. Tests are performed using weakly resistive industrial plastic foams. Experimental and numerical results, and prospects are discussed.

Journal Article↗

Standing wave patterns in the human ear canal used for estimation of acoustic energy reflectance at the eardrum.

Standing wave patterns were measured in the unoccluded ear canals of 13 human subjects, for applied pure tones of 3 to 13 kHz. Measurements were made, using a probe microphone technique, over a region which could be approximated as a duct of constant cross-sectional area. Analysis of the patterns allowed the reflective properties of the middle ear to be determined in terms of an acoustic energy reflection coefficient, or reflectance, at the eardrum. Over all subjects the trend of the results was for the energy reflection coefficient to rise from about 0.3 at 4 kHz up to 0.8 at 8 kHz, and continue at this value to 13 kHz. There was, however, significant intersubject variation, especially at frequencies greater than 7 kHz.

Acoustic Impedance Tests↗

Effects of a single reflection with varied horizontal angle and time delay on speech intelligibility.

Previously, almost all physical measures for estimating speech intelligibility in a room have been derived from only temporal-monaural criteria. This paper shows that speech intelligibility for a sound field with a single reflection depends not only on the temporal-monaural factor but also on the spatial-binaural factor of the sound field. Articulation tests for sound fields simulated with a single reflection of delay time delta t1 after the direct sound were conducted changing the horizontal incident angle xi of the reflection. Remarkable findings are as followings: (1) speech intelligibility (SI) decreases with increasing delay time delta t1, (2) SI increases when xi approaches 90 degrees; the horizontal angle of the reflection causes a significant effect on SI, and (3) the analysis of variance for articulation test scores clearly demonstrated that the effects of both delta t1 and xi on SI are fully independent. Concerning result (2), if listeners get a spatial separation of signals at the two ears, then the listener's capability for speech perception is assumed to be improved due to "adding" further information to the temporal pattern recognition.

Acoustics↗

Method to measure acoustic impedance and reflection coefficient.

A frequency-domain based system for measuring acoustic impedance and reflection coefficient is described. The calibration procedure uses a least-mean-squares approximation to the Thevenin parameters describing the source and receiver characteristics in which the data measured on closed, cylindrical tubes are matched to a viscothermal tube model. The system is intended for use in acoustical measurement in human ear canals, in which the cross-sectional area of the ear canal at the point of insertion is imprecisely known. This area is acoustically estimated from the impedance data, and the reflection coefficient is calculated in terms of this area and the impedance data. Measurements on a variety of closed tubes show the method is accurate over the frequency range investigated (less than 10.7 kHz). The time-domain reflection function is evaluated by transforming the reflection coefficient from the frequency domain, but the finite bandwidth of the measured data limits the accuracy of time-domain response measurements. The method is well suited for frequency-domain measurements in human ear canals.

Acoustic Impedance Tests↗

The effects of viscoelasticity on the reflection and transmission of ultrasonic waves by an orthotropic plate.

In this paper both theoretical and experimental investigations on the reflection and transmission of an incident plane wave by immersed viscoelastic orthotropic plates are presented. Taking the anisotropy of the layer into account the reflection and transmission coefficients are expressed in terms of nine complex elastic constants. In agreement with the Snell's laws, any waves generated in the layer are bulk heterogeneous plane waves. Using a method already described in the isotropic case, the reflection and transmission coefficients are obtained as a function of the reflection and refraction coefficients of bulk heterogeneous plane waves at the two single solid/liquid interfaces, which limit the plate. In this way, these coefficients can be easily expanded in Debye's series. In addition, for many incident and azimuthal angles, the calculations are compared with trial results on a composite made of unidirectional carbon fibers and epoxy matrix. Finally, by the measurement of the variation of attenuation versus the frequency, a linear model permits the computations in a large frequency range. Conclusions are carried out regarding the use of the LLW method in the inverse problem to recover elastic constants of composite materials.

Acoustics↗

Energy reflectance in the ear canal can exceed unity near spontaneous otoacoustic emission frequencies.

There is some controversy in the literature over whether the so-called "active mechanism" or "cochlear amplifier" is actually a power amplifier that can produce an output signal with more power than its input, or whether it simply minimizes dissipative losses within the cochlea without providing an actual power gain greater than unity. A corollary of this controversy is whether spontaneous otoacoustic emissions (SOAEs) represent the output of a nonlinear oscillator mechanism, i.e., a power amplifier which can produce an oscillatory output signal in the absence of an input oscillatory signal, or whether they represent the output of a noise-driven, passive, nonlinear system. This paper describes measurements of energy reflectance, and acoustic impedance in the ear canals of human subjects with strong SOAEs. The reflectance, and the resistive and reactive parts of the acoustic impedance, all show a frequency fine structure which correlates with SOAE frequencies, and which becomes more pronounced at low stimulus levels. In some ears at some SOAE frequencies, energy reflectance exceeds unity, and correspondingly, acoustic resistance is negative. This result demonstrates that there is a power gain at these frequencies: The power reflected from the cochlea to the ear canal exceeds the power incident. It is also consistent with the theory that these SOAEs are produced by a nonlinear oscillator mechanism in the cochlea.

Ear Canal↗

Thermohaline fine structure in an oceanographic front from seismic reflection profiling.

We present acoustic images of oceanic thermohaline structure created from marine seismic reflection profiles across the major oceanographic front between the Labrador Current and the North Atlantic Current. The images show that distinct water masses can be mapped, and their internal structure imaged, using low-frequency acoustic reflections from sound speed contrasts at interfaces across which temperature changes. The warm/cold front is characterized by east-dipping reflections generated by thermohaline intrusions in the uppermost 1000 meters of the ocean. Our results imply that marine seismic reflection techniques can provide excellent spatial resolution of important oceanic phenomena, including thermohaline intrusions, internal waves, and eddies.

Journal Article↗

INDEPTH Wide-Angle Reflection Observation of P-Wave-to-S-Wave Conversion from Crustal Bright Spots in Tibet

Three-component wide-angle seismic data acquired in southern Tibet during Project INDEPTH show strong P-to-S converted reflections from reflectors that are aligned at a depth of approximately 15 kilometers beneath the northern Yadong-Gulu rift. These converted reflections are locally higher in amplitude than the corresponding P-wave reflections. Modeling of reflection mode conversion as a function of incidence angle indicates that this condition obtains for a reflector that is a solid over fluid interface; it is not typical of a solid-solid interface. The likely candidates for a fluid trapped within the crystalline crust of southern Tibet are granitic magma and water (brine).

Journal Article↗

Reflections on the early years of nuclear medicine.

In the early years of nuclear medicine, physicians explored applied nuclear physics, and physicists pursued uncharted areas in medicine. Reflections from Jim Adelstein, MD, PhD, John McAfee, MD, Henry Wagner, MD, Fred Bonte, MD, Dave Kuhl, MD, and Alex Gottschalk, MD, add to the appreciation of the diversity in those early years. These reflections may serve many purposes. For some, they may provoke nostalgia for the better life gone by. For others, reflections may create an awareness of the people and the process of what it took to be where we are today. For still others, this may provide some impetus to better understand the origins of modern imaging technologies and their diffusion. Which techniques in use today will be in use 30 years from now? Why will some survive and others go by the wayside? From research into the process of technology transfer and diffusion, can we learn to put our efforts today where they will have the greatest benefits to human beings some 30 years from now? How can we maximize the present value of our efforts to improve diagnostic imaging? Reflections from the past may help.

Diffusion of Innovation↗

Reflectance spectrophotometry for the assessment of gastroduodenal mucosal perfusion.

Reflectance spectrophotometry in assessing gastroduodenal mucosal perfusion was evaluated. Ischemia without congestion, e.g., during hemorrhagic hypotension or celiac artery occlusion, was associated with a reduction in the indexes of mucosal hemoglobin concentration and of oxygen saturation. Ischemia with congestion, e.g., during portal vein occlusion, or in absolute ethanol or suction-induced mucosal lesions, was associated with an increase in the index of mucosal hemoglobin concentration but a reduction in the index of oxygen saturation. An increase in the index of mucosal hemoglobin concentration associated with a normal index of oxygen saturation was found in the postischemic hyperemia after release of celiac artery occlusion and during the sustained increase in corpus mucosal blood flow induced by vagus nerve stimulation. Thus reflectance spectrophotometric measurements reflected ischemia, without or with congestion, and hyperemia. Additionally, although regional differences in reflectance spectrophotometric measurements were demonstrated in the duodenal, antral, and corpus mucosa, such differences bore no consistent relationship to regional differences in blood flow demonstrated in previous studies.

Animals↗

Functional origin of reflected pressure waves in a multibranched model of the human arterial system.

The effects of wave travel and wave reflection were simulated in a mathematical model of the whole arterial tree consisting of 142 uniform transmission line segments. The arterial model was partitioned into three separate segments: upper limbs, trunk, and lower limbs. Aging was simulated by increasing average pulse wave velocities of these segments (10.9-12.9, 8.0-11.7, and 9.0-11.3 m/s for upper limbs, trunk, and lower limbs, respectively). Reflection coefficients at the terminal elements were altered to simulate vasodilation (0.0) and vasoconstriction (0.95). The impedance patterns and spatial distribution of pressure waveforms generated by the model simulating aging and vasoconstriction were similar to in vivo measurements by other investigators. Reflected pressure waves from each segment reached the ascending aorta and contributed differently to the late systolic peak on the aortic pressure wave. Aging does not alter the origin of these reflected pressure waves in the trunk. Aortic impedance and pressure wave changes induced by simulation of dilation of splanchnic bed were similar to those observed experimentally with nitroglycerin.

Aorta↗

Comparative analysis of aortic impedance and wave reflection in ferrets and dogs.

Our modified version of the T-tube arterial model (consisting of two parallel, loss-free transmission paths terminating in lumped loads of complex and frequency-dependent nature) was applied to experimental measurements of ascending aortic pressure and of ascending and descending aortic flows taken from dogs and ferrets. Our aim was to provide quantitative evaluation of the aortic pressure and flow pulse wave components as they relate to the distribution of arterial properties and relate to wave travel and reflection in mammalians of consistently different size and shape. Estimated effective lengths (distances to effective reflection sites) of the head-end (d(h)) and body-end (d(b)) transmission paths were approximately 12 and 30 cm, respectively, in the dog and 6.5 and 13 cm, respectively, in the ferret. These lengths and distributions of estimated arterial properties were consistent with the difference in the body size and with the more central location of the heart in the ferret's body than it is in the dog's body. In both animal species the ascending aortic pressure and flow waves could be interpreted in terms of forward and reflected components arising from the two distinct effective reflection sites, although the higher d(h)/d(b) ratio in the ferret determined the presence of one broad, indistinct minimum in the modulus of ascending aortic impedance in the frequency range from 0 to 10 Hz, rather than two distinct minima as observed in the dog.

Animals↗

Exaggerated wave reflection in the kangaroo simulates arterial counterpulsation.

The ascending aortic pressure wave in kangaroos is quite different from that seen in other experimental animals and in humans, despite an ascending aortic flow wave that is virtually identical. The diastolic pressure surge in the ascending aortic pressure wave of kangaroos is very prominent--so much so that peak diastolic pressure is often greater than peak systolic pressure, with the pressure wave resembling that recorded in humans during intra-aortic balloon counterpulsation. Ascending aortic impedance patterns in kangaroos indicate the presence of a single functionally discrete reflecting site in the peripheral circulation, with high reflection coefficient. All findings--of pulse contour and impedance patterns--are explicable on the basis of arterial anatomy and body shape. Wave reflection from the distant, large, and vascular lower body appears to dominate the effects of wave reflection from the short, small, and less vascular head and forelimb system.

Animals↗

Pulmonary vascular impedance and wave reflections in the hypoxic calf.

The alterations in pulsatile hemodynamics that occur during hypoxic pulmonary vasoconstriction have not been well characterized. Changes in oscillatory hemodynamics, however, may affect right ventricular-pulmonary vascular coupling and the dissipation of energy within the lung vasculature. To better define hypoxic pulsatile hemodynamics, we measured main pulmonary artery proximal and distal micromanometric pressures and ultrasonic flow in four open-chest calves during progressive hypoxia. Main pulmonary artery impedance and pressure transmission spectra were calculated using spectral analysis methods. Measured pressure and flow signals were separated in the time domain into forward and backward components. Hypoxia increased pulmonary blood pressure and resistance and produced multiple modifications in the impedance and pressure transmission spectra that indicated increased wave reflections and elasticity. The impedance and apparent phase velocity first-harmonic values were increased in amplitude, and the pressure transmission modulus plot showed an increased peak value. In addition, the impedance modulus plot demonstrated a rightward shift and increased oscillation in the mid- to high-frequency range. The time domain analysis also confirmed increased wave reflections and elasticity. Hypoxia produced large backward-traveling (reflected) pressure and flow waves. The initial portions of these waves arrived at the heart during systole, producing characteristic changes in the measured pressure and flow waveforms. With prolonged hypoxia, main pulmonary artery pulse wave velocity increased by 30%. Thus, hypoxia is associated with complex alterations in pulmonary artery elasticity and wave reflections that act to increase the oscillatory afterload of the right ventricle.

Animals↗

Reflectance spectroscopy of pancreatic microcirculation.

A technique employing diffuse reflectance spectroscopy (DRS) is described to assess and mirror dynamic changes of pancreatic tissue perfusion. An especially designed reflectance spectrophotometer was initially used to derive the quantitative relation between hemoglobin concentration ([Hb]) and reflectance measurements in vitro. Over a wide range of scattering related to the medium in which the measurements were made (scattering coefficient: 6.5-13 cm-1), a close, direct correlation existed with a slope of 0.376 +/- 0.012. In Sprague-Dawley rats under general anesthesia, the pancreas was isolated in situ and perfused with graded infusions of hemoglobin solutions. A correlation, comparable to the in vitro setting, was found between a [Hb] of 0 and 14 g/dl in the perfusate with slopes of 0.0037 and 0.0035. Changes in perfusion induced by adrenergic drugs produced changes in hemoglobin oxygen saturation and [Hb] that correspond with measured alterations of systemic arterial pressure and aortic blood flow. We conclude that diffuse reflectance spectroscopy reliably provides data on intrapancreatic hemoglobin oxygen saturation and [Hb] that can be a valuable tool for minimally invasive on-line evaluation of these aspects of pancreatic perfusion in the rat. This newly designed device is superior to previously used ones in that it analyzes the entire spectrum and therefore can account for changes in scattering that are very likely to occur with pathophysiological alterations such as edema formation.

Animals↗

Acute effects of cold exposure on central aortic wave reflection.

The purpose of this study was to determine the effects of acute cold exposure on the timing and amplitude of central aortic wave reflection and central pressure. We hypothesized that cold exposure would result in an early return of reflected pressure waves from the periphery and an increase in central aortic systolic pressure as a result of cold-induced vasoconstriction. Twelve apparently healthy men (age 27.8 +/- 2.0 yr) were studied at random, in either temperate (24 degrees C) or cold (4 degrees C) conditions. Measurements of brachial artery blood pressure and the synthesis of a central aortic pressure waveform (by noninvasive radial artery applanation tonometry and use of a generalized transfer) were conducted at baseline and after 30 min in each condition. Central aortic augmentation index (AI), an index of wave reflection, was calculated from the aortic pressure waveform. Cold induced an increase (P < 0.05) in AI from 3.4 +/- 1.9 to 19.4 +/- 1.8%. Cold increased (P < 0.05) both brachial and central systolic pressure; however, the magnitude of change in central systolic pressure was greater (P < 0.05) than brachial (13 vs. 2.5%). These results demonstrate that cold exposure and the resulting peripheral vasoconstriction increase wave reflection and central systolic pressure. Additionally, alterations in central pressure during cold exposure were not evident from measures of brachial blood pressure.

Adult↗

Action potential reflection and failure at axon branch points cause stepwise changes in EPSPs in a neuron essential for learning.

In leech mechanosensory neurons, action potentials reverse direction, or reflect, at central branch points. This process enhances synaptic transmission from individual axon branches by rapidly activating synapses twice, thereby producing facilitation. At the same branch points action potentials may fail to propagate, which can reduce transmission. It is now shown that presynaptic action potential reflection and failure under physiological conditions influence transmission to the same postsynaptic neuron, the S cell. The S cell is an interneuron essential for a form of nonassociative learning, sensitization of the whole body shortening reflex. The P to S synapse has components that appear monosynaptic (termed "direct") and polysynaptic, both with glutamatergic pharmacology. Reflection at P cell branch points on average doubled transmission to the S cell, whereas action potential failure, or conduction block, at the same branch points decreased it by one-half. Each of two different branch points affected transmission, indicating that the P to S connection is spatially distributed around these branch points. This was confirmed by examining the locations of individual contacts made by the P cell with the S cell and its electrically coupled partner C cells. These results show that presynaptic neuronal morphology produces a range of transmission states at a set of synapses onto a neuron necessary for a form of learning. Reflection and conduction block are activity-dependent and are basic properties of action potential propagation that have been seen in other systems, including axons and dendrites in the mammalian brain. Individual branch points and the distribution of synapses around those branch points can substantially influence neuronal transmission and plasticity.

Action Potentials↗