Laparoscopic removal of translocated retroperitoneal IUD.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Removal efficiencies of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) by air pollution control devices (APCDs) in the commercial-scale municipal solid waste (MSW) incinerators with a capacity of above 200 ton/day were evaluated. The removal efficiencies of PCDDs/PCDFs were up to 95% when the activated carbon (AC) was injected in front of electrostatic precipitator (EP). Spray dryer absorber/bag filter (SDA/BF) had high removal efficiency (99%)) of PCDDs/PCDFs when a mixture of lime and AC was sprayed into the SDA. When the AC was not added in scrubbing solution, the whole congeners of PCDDs/PCDFs were enriched in the wet scrubber (WS) with negative removal efficiencies of -25% to -5731%. Discharge of PCDDs/PCDFs was decreased with increasing the proportions of AC added in scrubbing solution. Selective catalytic reduction (SCR) system had the removal efficiencies of up to 93% during the test operation.
OBJECTIVE: Glial cell line-derived neurotrophic factor (GDNF) exerts potent trophic influence on midbrain dopaminergic neurons. This randomized controlled clinical trial was designed to confirm initial clinical benefits observed in a small, open-label trial using intraputamenal (Ipu) infusion of recombinant human GDNF (liatermin). METHODS: Thirty-four PD patients were randomized 1 to 1 to receive bilateral continuous Ipu infusion of liatermin 15 microg/putamen/day or placebo. The primary end point was the change in Unified Parkinson Disease Rating Scale (UPDRS) motor score in the practically defined off condition at 6 months. Secondary end points included other UPDRS scores, motor tests, dyskinesia ratings, patient diaries, and (18)F-dopa uptake. RESULTS: At 6 months, mean percentage changes in "off" UPDRS motor score were -10.0% and -4.5% in the liatermin and placebo groups, respectively. This treatment difference was not significant (95% confidence interval, -23.0 to 12.0, p = 0.53). Secondary end point results were similar between the groups. A 32.5% treatment difference favoring liatermin in mean (18)F-dopa influx constant (p = 0.019) was observed. Serious, device-related adverse events required surgical repositioning of catheters in two patients and removal of devices in another. Neutralizing antiliatermin antibodies were detected in three patients (one on-study and two in the open-label extension). INTERPRETATION: Liatermin did not confer the predetermined level of clinical benefit to patients with PD despite increased (18)F-dopa uptake. It is uncertain whether technical differences between this trial and positive open-label studies contributed in any way this negative outcome.
BACKGROUND: Expandable metallic stents (EMS) have seen wide application in patients with malignant stricture and fistulas. They have not seen wide application for benign disease because of concern over acute complications and long-term sequelae. METHODS: Between June 1999 and October 2000, six patients with EMS in place for malignant stricture (n = 3), benign stricture (n = 1), anastomotic leak (n = 1) and benign esophagorespiratory fistula (n = 1) had their stents endoscopically removed. Removal was performed secondarily to the following complications: secondary stricture (n = 1), epidural abscess (n = 1), diskitis (n = 1), resolution of fistula (n = 2), and resolution of anastomotic leak (n = 1). RESULTS: Four patients had one EMS: Ultraflex (n = 3) and Z-stent (n = 1). In two patients, two stents (Ultraflex and Z-stent) were retrieved simultaneously. No procedurally related complications occurred. Two patients with esophageal cancer required additional stents. All three patients with benign fistula and stricture recovered uneventfully. CONCLUSIONS: The safe removal of current brands of EMS may facilitate the wider application of these devices to include selective patients with benign disease.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Over the last 40 years, plasmapheresis technology and its indications for use have been continually evolving. With the growing incidence for autoimmune diseases, unsatisfactory therapeutic options, side effects of drug therapy, and economic relevance, apheresis clinicians have been leaning toward more selective plasmapheresis techniques through the use of plasma fractionators and immunoadsorption columns. Plasma fractionators are mostly used in Asia, and rarely utilized in the U.S. The majority of plasma filters approved by the Food and Drug Administration (FDA) are primary membrane plasma separators, which still require replacement fluid. The secondary plasma fractionators available in the U.S. are limited in used and mostly investigational. Immunoadsorption columns, mostly used in Europe, are gaining popularity in the U.S. Some FDA-approved immunoadsorption columns include the Prosorba protein-A silica column, Immunosorba tryptophan and phenylalanine columns, Immunosorba protein-A sepharose column, and Liposorber dextran sulfate column. In addition, the heparin-induce extracorporeal lipoprotein precipitation (HELP) system is also FDA-approved. However, there are other immunoadsorption technologies used in Europe, such as direct adsorption lipoprotein LDL-hemoperfusion, not yet available in the U.S. While each method of apheresis carries its own risks and benefits, it is the opinion of the authors that these additional apheresis techniques be available to U.S. researchers and clinicians as a therapeutic option. The authors believe that the U.S. need to aggressively investigate more specific plasmapheresis modalities and establish appropriate dialogue with regulatory and reimbursement officials for FDA-approval of these devices.
Female, 57 year-old patient, reported having undergone surgery for correction of urinary incontinence due to sphincteric insufficiency with the implantation of a synthetic pubovaginal sling 14 months earlier. Though she did not present urine loss any longer, approximately 60 days following the surgical procedure she started to report dysuria, pollakiuria and dyspareunia. Attempts of a conservative solution were ineffective. The appearance of a vaginal infra-urethral granuloma and the exteriorization of the synthetic material led to its removal.
Evidence-based medicine has been defined as "the conscientious, explicit, and judicious use of current best evidence in making decisions about the care of individual patients" (Sackett et al., 1996). Evidence-based nursing takes the process one step further by integrating clinical expertise and the data obtained from performance improvement processes with clinical research. The challenge nursing then faces is to translate the evidence into practice. Although central line removal is a fairly common procedure, it is not benign. The authors noted an opportunity for improving central venous catheter (CVC) removal from the subclavian or internal jugular vein. Based upon previously recommended guidelines (Kim et al., 1998), the authors set out to determine the best practice related to CVC removal.
BACKGROUND: As the number of implanted vagal nerve stimulators grows, the need for removal or revision of the devices will become more frequent. Our purpose was to demonstrate the feasibility of complete removal of the vagal nerve stimulator electrode using microsurgical technique. METHODS: . Operative databases at the University of Utah (1995 through 2002), Westchester Medical Center (1995 through 2001), and University of Arizona Health Sciences Center (1995 through 1999) were retrospectively reviewed. Patients who had undergone removal or revision of a previously placed vagal nerve stimulator electrode were identified. Patients who had a vagal nerve stimulator device removed but had the lead trimmed and incompletely removed were excluded. FINDINGS: Seven patients underwent complete removal of the lead. Microsurgical dissection allowed removal of the helical electrode from the vagus nerve without apparent physiological consequences. Four patients had a new electrode placed just proximal to the original lead site. The operative procedure required an additional 30 minutes to complete compared with initial device placement. The four patients who underwent replacement of the electrode demonstrated normal device function and lead resistance at the time of postoperative follow-up. Each experienced a return to prior stimulation response and seizure control. CONCLUSIONS: This series suggests that the electrode can be removed from the vagus nerve and repositioned without significant consequence in most cases.