Prevention of intraoperative hypothermia during abdominal surgery.

Heat balance and core and skin temperatures were studied in 111 patients during abdominal surgery. In minor surgical procedures the effects of heating of inspired humidified gases (n = 23) and of a heating mattress (n = 21) were compared with the conditions in an unwarmed control group (n = 24). These two methods were about equally effective in preserving total body heat, although the major effect of the heating mattress was to conserve heat which had been redistributed to the surface, and such heat could subsequently be lost to the environment. During major abdominal surgery 18 unwarmed control patients were compared with patients (n = 25) provided with a heat supply. The combined measures of heated humidified inspired gases, a heating mattress, insulation by a heat-reflecting blanket, warming of all infusions and transfusions and a warm operating room were all needed to balance the great heat losses during the major surgical procedures. With such massive heat supply it was possible to prevent heat loss and a fall in core temperature.

Abdomen↗

Sheepskins and bedding in childhood, and the risk of development of bronchial asthma.

BACKGROUND: Sheepskin bedding might increase house dust mite exposure and so explain some of the increasing prevalence of severity of childhood asthma. METHODS: Relationships between use of different types of bedding, and diagnoses of asthma, symptoms of wheezing, skin prick test evidence of house dust mite sensitivity, and airway responsiveness to methacholine, were examined retrospectively in a birth cohort of children followed longitudinally to age 15 years. RESULTS: In the whole cohort, no associations were identified to suggest a causal relationship between use of any type of bedding and development of features of asthma. Although not an a priori hypothesis, we noted that among children with a family history of atopic disease, those who were house dust mite sensitive were more likely to have used an innerspring mattress (29.6% vs 10.2% who had not used an innerspring mattress, p = 0.005). CONCLUSION: In this subgroup, increased airway responsiveness and mite sensitivity were significantly associated with use of innerspring mattresses, although whether this is a causal or secondary association is not certain. Use of a sheepskin in the bed in early childhood was not an additional risk factor for the development of asthma.

Allergens↗

Cost of pressure ulcer prevention in long-term care.

OBJECTIVE: To describe the total cost of pressure ulcer prevention, component costs of each intervention, and the relationship of costs to subjects' risk level. DESIGN: 3-month cohort trial. SETTING: A 600-bed, state-supported, long-term care facility. PATIENTS: A total of 539 war veterans, 83% of whom were male; mean age was 73 years. MAIN OUTCOME MEASURES: Cost to facility for using each of four preventive interventions: turning, pressure-reducing mattresses, chair cushions, miscellaneous preventive devices. RESULTS: Sixty-eight percent of subjects received a preventive intervention. Total 3-month facility cost of prevention was $132,114, and 97% of the cost was consumed by 30% of the subjects. Turning was the most expensive component, accounting for $99,567. The daily cost of turning for subjects who received it was $8.83 +/- 1.66. Cost increased with subject risk level. Low cost devices were instituted for lower risk subjects, whereas high cost interventions (turning) were reserved for the highest risk subjects. CONCLUSIONS: This long-term care facility expended substantial resources on prevention, and most resources (97%) were expended on less than half (30%) of subjects. Turning was, by far, the most expensive intervention, and the nursing staff reserved it for highest risk subjects. Strategies that substitute moderately priced mattresses for frequent turning may decrease the cost of prevention, as long as mattress cost is less than the daily turning costs it replaces. Future research to define the optimum combinations of preventive interventions for patients of various risk levels is needed.

Aged↗

Mechanical vibration in ambulance transport.

OBJECTIVE: To study the effects of mechanical vibration on neonates during ambulance transport. DESIGN: Study used an infant mannequin in an isolette and measured the vibration levels experienced during controlled ambulance transports. PARTICIPANTS: Transport nurses and paramedics used a hospital-based mobile intensive care unit (MICU). MAIN OUTCOME MEASURE: Measured vibration levels at specific locations within the ambulance and isolette. Investigated nonstandard mattresses and additional modifications to the isolette that would dampen the vibration transferred to the neonate. RESULTS: The analysis of variance showed significant differences (p < .002) in the amount of vibration among the specific locations in the ambulance. A gel-filled mattress decreased the transfer of mechanical vibration to the infant mannequin. Additional modifications to the isolette tray decreased vibration. CONCLUSIONS: Relatively inexpensive modifications can be made to the isolette tray and mattress to decrease the vibration levels experienced in transport.

Acceleration↗

Allergens and endotoxin in settled dust from day-care centers and schools in Oslo, Norway.

UNLABELLED: Allergy to indoor allergens can cause frequent and severe health problems in children. Because little is known about the content of allergens in the indoor environments in Norway, we wanted to assess the levels of cat, dog and mite allergens in schools and day-care centers in Oslo. Allergen levels in dust samples from 155 classrooms and 81 day-care units were measured using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Additionally, we measured the levels of endotoxin in 31 day-care units, using the limulus amebocyte lysate test. Most of the dust samples contained detectable amounts of cat and dog allergens. In mattress and floor dust (day-care centers), and curtain and floor dust (schools) the median Fel d 1 levels were 0.17, 0.002, 0.02 and 0.079 microg/m2, while the median Can f 1 levels were 1.7, 0.03, 0.1 and 0.69 microg/m2, respectively. Levels of cat and dog allergens in school floor dust were associated with the number of pupils with animals at home. In contrast, <1% of the samples had measurable levels of the mite allergen Der p 1. Moreover, the levels of endotoxin tended to be higher in dust from floors (1.4 ng/m2) compared with that from mattresses (0.9 ng/m2). PRACTICAL IMPLICATIONS: To reduce allergen exposure, allergic individuals should be placed in the classes/rooms with the fewest pet owners. Moreover, mattresses in day-care centers are major reservoirs of cat and dog allergens and should be cleaned frequently.

Air Pollution, Indoor↗

Uneven distribution of light in standard phototherapy.

Maldistribution of light is a potential cause of phototherapy failure in the neonate. Differences in light intensity over the surface can be measured with a radiometer as this detects the radiant energy impinging on the incubator mattress. An infant nursed on the front third of the mattress receives less than 40% of the maximal light incident on the centre of the mattress, and consequently degradation of unconjugated bilirubin will be less effective.

Humans↗

Case-control study of sudden infant death syndrome in Scotland, 1992-5.

OBJECTIVE: To investigate the relation between routine infant care practices and the sudden infant death syndrome in Scotland. METHODS: National study of 201 infants dying of the sudden infant death syndrome (cases) and 276 controls by means of home interviews comparing methods of infant care and socioeconomic factors. RESULTS: Sleeping prone (odds ratio 6.96 (95% confidence interval 1.51 to 31.97) and drug treatment in the previous week (odds ratio 2.33 (1.10 to 4.94)) were more common in the cases than controls on multivariate analysis. Smoking was confirmed as a significant risk factor (odds ratio for mother and father both smoking 5.19 (2.26 to 11.91)). The risk increased with the number of parents smoking (P < 0.0001), with the number of cigarettes smoked by mother or father (P = 0.0001), and with bed sharing (P < 0.005). A new finding was an increased risk of dying of the syndrome for infants who slept at night on a mattress previously used by another infant or adult (odds ratio 2.51 (1.39 to 4.52)). However, this increased risk was not established for mattresses totally covered by polyvinyl chloride. CONCLUSIONS: Sleeping prone and parental smoking are confirmed as modifiable risk factors for the sudden infant death syndrome. Sleeping on an old mattress may be important but needs confirmation before recommendations can be made.

Bedding and Linens↗

Endotoxin levels in rural Thai and urban Singaporean homes.

BACKGROUND: Exposure to dust endotoxin and allergens in early childhood may influence the development of allergic diseases. AIMS: This study aimed to evaluate dust endotoxin and dust mite allergens in urban Singapore and rural Thai homes of young children and study potential environmental influences. METHODS: Mattress dust endotoxin and Der p 1, Der f 1, group 2 (Der f 2 and Der p 2) and Blo t 5 allergen levels were quantified in 101 infant mattress dust samples, 51 from urban Singapore and 50 from rural Thailand. Comprehensive questionnaires on the home environment and cleaning practices were completed. RESULTS: Endotoxin levels in rural Thailand were significantly higher than in urban Singapore (geometric mean 26,334.12 +/- 4.60 and 18,377.85 +/- 2.52 endotoxin units/g, respectively; p = 0.032). In contrast, higher levels of Der f 1 (p = 0.02), group 2 (p < 0.01) and Blo t 5 (p < 0.01) allergens were found in Singapore homes compared with rural Thai homes. Multiple logistic regression analysis showed that the use of detergents (p = 0.001) and disinfectants (p = 0.024) to clean floors and mattress protectors (p = 0.021) were independently associated with lower endotoxin levels. CONCLUSION: Endotoxin levels are higher in rural compared with urban homes in South East Asia. The reverse was true for dust mite allergen levels. Certain identifiable home environmental conditions and practices accounted for the differences in endotoxin levels.

Air Pollution, Indoor↗

Limitations of a home characteristics questionnaire as a predictor of indoor allergen levels.

We examined associations between reported home characteristics and levels of indoor allergens in 499 homes of a birth cohort of children of allergic/asthmatic families from the Boston area. The risk of having dust mite allergen (Der f 1 or Der p 1) > or = 2 microg/g on the bedroom floor was highest in houses, but 16% of apartments had levels this high. Compared with that from smooth floors, dust from carpeted bedroom floors had 2.1 times the risk of dust mite allergen > or = 10 microg/g, but levels exceeded 2 microg/g in 32% of uncarpeted floors. The risk of dust mite allergen > or = 10 microg/g of dust from plastic-encased mattresses was 0.5 times that for cloth mattresses, but levels in 21% of plastic-encased mattresses were > or = 2 microg/g. In 93% of homes with and 3% of homes without cats, Fel d 1 was > or = 8 microg/g, but 34% of homes without cats had Fed d 1 > or = 1 microg/g. Cockroach allergen (Bla g 1 or Bla g 2) was > or = 2 U/g of kitchen dust in 26% of apartments and only 6% of houses, and it was detected in 48% of homes with no reported signs of cockroaches in the previous 12 mo. Home characteristics reporting is a relatively weak predictor of the absence of allergen, and exposure can occur even when no cats are present, beds are encased in plastic, no carpets are present, and no signs of cockroaches have been reported.

Air Pollution, Indoor↗

Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques.

BACKGROUND: Interface contact pressure between the tendon and bone has been shown to influence healing. This study evaluates the interface pressure of the rotator cuff tendon to the greater tuberosity for different rotator cuff repair techniques. HYPOTHESIS: The transosseous tunnel rotator cuff repair technique provides larger pressure distributions over a defined insertion footprint than do suture anchor techniques. STUDY DESIGN: Controlled laboratory study. METHODS: Simulated rotator cuff tears over a 1 x 2-cm infraspinatus insertion footprint were created in 25 bovine shoulders. A transosseous tunnel simple suture technique (n = 8), suture anchor simple technique (n = 9), and suture anchor mattress technique (n = 8) were used for repair. Pressurized contact areas and mean pressures of the repaired tendon against the tuberosity were determined using pressure-sensitive film placed between the tendon and the tuberosity. RESULTS: The mean contact area between the tendon and tuberosity insertion footprint was significantly greater for the transosseous technique (67.7 +/- 5.8 mm(2)) compared with the suture anchor simple (34.1 +/- 9.4 mm(2)) and suture anchor mattress (26.0 +/- 5.3 mm(2)) techniques (P < .05). The mean interface pressure exerted over the footprint by the tendon was also greater for the transosseous technique (0.32 +/- 0.05 MPa) compared with the suture anchor simple (0.26 +/- 0.04 MPa) and suture anchor mattress (0.24 +/- 0.02 MPa) techniques (P < .05). CONCLUSION: The transosseous tunnel rotator cuff repair technique creates significantly more contact and greater overall pressure distribution over a defined footprint when compared with suture anchor techniques. CLINICAL RELEVANCE: Stronger and faster rotator cuff healing may be expected when beneficial pressure distributions exist between the repaired rotator cuff and its insertion footprint. Tendon-to-tuberosity pressure and contact characteristics should be considered in the development of improved open and arthroscopic rotator cuff repair techniques.

Animals↗

Biovolatilization of antimony and sudden infant death syndrome (SIDS).

1. The aerobic filamentous fungus S. brevicaulis IMI 17297 methylated antimony from Sb2O3 substrate, with the formation of gaseous trimethylantimony (TMA). No evidence was found for the generation of other gaseous antimony compounds by this organism. 2. Biovolatilization of inorganic antimony was greatest during cultivation of the fungus on solid media at 25 degrees C, and occurred more readily from antimony (III) substrates than from antimony (V) substrates. 3. Under simulated cot environment conditions (CO2 enriched atmosphere, 33 degrees C) the fungus exhibited an altered morphology and a reduced capability to volatilize inorganic antimony from the pure compound. 4. No evidence of antimony biovolatilization from cot mattress PVC was found, unless antimony was released from PVC by heat treatment (at 80 or 100 degrees C). 5. These data suggest that normal cot environment conditions are non-optimal for volatilization of antimony by S. brevicaulis, and that Sb2O3 in cot mattress PVC is not bioavailable. 6. Cot mattress isolates of S. brevicaulis also volatilized antimony (not encapsulated by PVC), whereas those of other filamentous fungi (Penicillium spp., Aspergillus niger, Aspergillus fumigatus, Alternaria sp.) and of bacteria (Bacillus spp.) did not. 7. The oxidation products of TMA may be the true determinants of toxicity for biogenic antimony gases produced in an aerobic environment.

Antimony↗

Overview of research to investigate pressure-relieving surfaces.

Pressure-relieving equipment plays a key role in the prevention and treatment of pressure ulcers. Every year an increasing amount of equipment is launched on to the market. The efficacy of this equipment is traditionally qualified with interface pressure and case studies, but rarely with randomized controlled trials. With the advent of The New NHS: Modern, Dependable (Department of Health (DoH), 1997) and Pressure Ulcer Risk Assessment and Prevention (National Institute for Clinical Excellence (NICE), 2001), a clinical governance system has started to be put into place and hopefully more evidence will be produced by the manufacturers and the NHS. With some 200 different types of mattresses on the market, emphasis needs to be placed on good quality randomized clinical trials to establish effectiveness of what can be costly equipment. This article gives an overview of how, historically, pressure-relieving mattresses were marketed on case studies and interface measurement. Recently, randomized controlled clinical trials are being used to demonstrate the efficacy of the mattress and reduction in the incidence of pressure ulcers. Seating is also an important aspect in continuing 24-hours pressure area prevention and treatment. Patient posture in a chair needs to be fully understood by the practitioner and key strategies are made in this article. Little research into seating has been undertaken and is urgently required.

Beds↗

A randomised controlled trial of two pressure-reducing surfaces.

This randomised controlled trial of two dry-flotation pressure-reducing surfaces evaluates pressure sore incidence, patient comfort and the appropriate use of equipment in 100 orthopaedic patients. The trial involved five full Roho mattresses, five Sofflex mattresses and 10 Roho Quatro cushions to be used to complement the beds. Given the low rate of pressure sore incidence in this high-risk group it is not possible to determine whether there is any difference in effectiveness between the two mattresses. Both appear to provide similar levels of comfort, with the majority of patients finding them either comfortable or very comfortable. The initial setting of the equipment was, however, unsatisfactory.

Activities of Daily Living↗

Potential to prevent carbon dioxide rebreathing of commercial products marketed to reduce sudden infant death syndrome risk.

OBJECTIVE: Rebreathing of exhaled air is one proposed mechanism for the increased risk for sudden infant death syndrome among prone sleeping infants. We evaluated how carbon dioxide (CO(2)) dispersal was affected by a conventional crib mattress and 5 products recently marketed to prevent prone rebreathing. SETTING: Infant pulmonary laboratory. EQUIPMENT: An infant mannequin with its nares connected via tubing to an 100-mL reservoir filled with 5% CO(2). The sleep surfaces studied included: firm mattress covered by a sheet, Bumpa Bed, Breathe Easy, Kid Safe/Baby Air, Halo Sleep System, and Sleep Guardian. The mannequin was positioned prone face-down or near-face-down. The sleep surfaces were studied with the covering sheet taut, covering sheet wrinkled, and with the mannequin arm positioned up, near the face. MEASUREMENTS: . We measured the fall in percentage end-tidal CO(2) as the reservoir was ventilated with the piston pump. The half-time for CO(2) dispersal (t(1/2)) is an index of the ability to cause or prevent rebreathing. RESULTS: Compared with the face-to-side control, 5 of 6 surfaces allowed a significant increase in t(1/2) in all 3 prone scenarios. The firm mattress and 4 of the 5 surfaces designed to prevent rebreathing consistently allowed t(1/2) above thresholds for the onset of CO(2) retention and lethal rebreathing in an animal model (J Appl Physiol. 1995;78:740). CONCLUSIONS: With very few exceptions, infants should be placed supine for sleep. For infants placed prone or rolling to the prone position, significant rebreathing of exhaled air would be likely on all surfaces studied, except one.

Bedding and Linens↗

Pressure ulcer prevention.

The purpose of this collective review is to outline the predisposing factors in the development of pressure ulcers and to identify a pressure ulcer prevention program. The most frequent sites for pressure ulcers are areas of skin overlying bony prominences. There are four critical factors contributing to the development of pressure ulcers: pressure, shearing forces, friction, and moisture. Pressure is now viewed as the single most important etiologic factor in pressure ulcer formation. Prolonged immobilization, sensory deficit, circulatory disturbances, and poor nutrition have been identified as important risk factors in the development of pressure ulcer formation. Among the clinical assessment scales available, only two, the Braden Scale and Norton Scale, have been tested extensively for reliability and/or validity. The most commonly used risk assessment tools for pressure ulcer formation are computerized pressure monitoring and measurement of laser Doppler skin blood flow. Pressure ulcers can predispose the patient to a variety of complications that include bacteremia, osteomyelitis, squamous cell carcinoma, and sinus tracts. The three components of pressure ulcer prevention that must be considered in any patient include management of incontinence, nutritional support, and pressure relief. The pressure relief program must be individualized for non-weight-bearing individuals as well as those that can bear weight. For those that can not bear weight and passively stand, the RENAISSANCE Mattress Replacement System is recommended for the immobile patient who lies supine on the bed, the stretcher, or operating room table. This alternating pressure system is unique because it has three separate cells that are not interconnected. It is specifically designed so that deflation of each individual cell will reach a ZERO PRESSURE during each alternating pressure cycle. The superiority of this system has been documented by comprehensive clinical studies in which this system has been compared to the standard hospital bed as well as to two other commercially available pressure relief mattresses. The most recent advance in pressure ulcer prevention is the development of the ALTERN8* seating system. This seating system provides regular periods of pressure relief and stimulation of blood flow to skin areas while users are seated. By offering the combination of pressure relief therapy and an increase in blood flow, the ALTERN8* reportedly creates an optimum pressure ulcer healing environment. Foam is the most commonly used material for pressure reduction and pressure ulcer prevention and treatment for the mobile individual. For those immobilized individuals who can achieve a passive standing position, a powered wheelchair that allows the individual to achieve a passive standing position is recommended. The beneficial effects of passive standing have been documented by comprehensive scientific studies. These benefits include reduction of seating pressure, decreased bone demineralization, increased blander pressure, enhanced orthostatic circulatory regulation, reduction in muscular tone, decrease in upper extremity muscle stress, and enhanced functional status in general. In the absence of these dynamic alternating pressure seating systems and mattresses, there are enormous medicolegal implications to the healthcare facility. Because there is not sufficient staff to provide pressure relief to rotate the patient every 2 hours in a hospital setting, with the exception of the intensive care unit, the immobile patient is prone to develop pressure ulcers. The cost of caring for these preventable pressure ulcers may now be as high as 60,000 dollars per patient. The occupational physical strain sustained by nursing personnel in rotating their patients has led to occupational back pain in nurses, a major source of morbidity in the healthcare environment.

Aged↗

Inhaled air trapping effect of Japanese bedding as a risk of sudden unexpected death in infancy.

We assessed some Japanese bedding on the assumption of the effects of air trapping using an infant mannequin. The change of CO2 concentration in the airway of a mannequin head placed on bedding was continuously monitored using a CO2 analyzer during simulated breathing. To compare the level of CO2 dispersal among different items of bedding, CO2 half time (t1/2) values were used. The t1/2 values were calculated by measuring the time required for the expired percent CO2 to reach 1/2 the initial percent end-tidal PCO2. We also measured softness and resistance to airflow (R) of the same items. As for the bedding, 4 types of futon and several types of bottom sheets/towels were combined. The t1/2 value in supine position was 9.8 seconds. When the model was placed prone on futon, the t1/2 values increased to 14.1 seconds (hard mattress type)--17.2 seconds (soft cotton-like futon). With respect to present Japanese baby futon (hard mattress type), there may be a relatively low potential for rebreathing to occur, compared with soft futon. In every case, the t1/2 value was prolonged by the use of a towel spread on the futon. CO2 dispersal may depend not only on the softness of the futon, but also on the combination of bottom sheet/towel and mattress. There was no relationship between R values and t1/2 values. The potential of rebreathing increased in face down position among all bedding, and supine position was the best CO2 dispersal position.

Bedding and Linens↗

Age, side height, and spindle shape of the crib in climbing over the side.

The crib is the only infant product in which a consumer, such as a parent or caretaker, is encouraged to leave the infant unattended, usually alone in the bedroom, while the infant is sleeping or going to sleep or waking. Given frequent falls from the crib, federal crib regulations have set the minimum distance between the top of the mattress support and top of the crib side rail as 26 in. and this height must include a 6-in. thick mattress. When a mattress is used with the crib, the actual height of the crib side as a barrier is 20 in. These crib regulations also require instructions for the caretaker to discontinue using the crib when the child's height is 35 inches. These federal crib regulations attempt to create an escape-resistant sleeping environment for all children who are less than 35 in. tall. Of 144 children between the ages of 12.5 and 36.5 mo. observed while attempting to climb out of a crib, who also had standing heights of less than 35 in., many were able to climb from cribs with side rail heights of 26 in. When the crib side-rail height was raised beyond the minimum of 26 in., the frequency of children climbing over the crib rails decreased.

Accidental Falls↗

House dust mite allergy in Florida. Mite survey in households of mite-sensitive individuals in Tampa, Florida.

This study evaluated the prevalence of positive house dust mite skin tests in a population of atopic individuals and identified the mite species present in mattress and house dust samples in homes of the Tampa Bay area. Four hundred consecutive individuals were evaluated for respiratory complaints and skin tested with standardized extracts of Dermatophagoides pteronyssinus (Dp) and Dermatophagoides farinae (Df). Two hundred forty individuals (60%) had a positive skin test to the mite extracts. Dust samples were collected in 40 homes of mite-allergic individuals and analyzed by light microscopy. Mite species were found in 53 of the 60 dust samples (20 mattresses and 40 carpets). Mite numbers ranged from 110-6200 mites/g of mattress dust and from 120-5500 mites/g of carpet dust. Eleven different mite species were identified and Blomia tropicalis (Bt), not previously identified in the United States, was found in 30% of the samples. Dp and Df wee the predominant species. These observations suggest that house dust mite allergy is common in the Tampa Bay area and that the house dust mite fauna comprises several mite species besides Dp and Df. Prospective studies in progress are designed to confirm the role of different mite species in house dust mite allergy.

Air Pollutants↗