PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation.

Microfluidic devices are increasingly used to perform biological experiments on a single-cell basis. However, long-term stability of cell positions is still an issue. A novel biocompatible method for cell entrapment and release on a microchip is presented. It is based on the controlled formation of an alginate hydrogel by bringing two laminar flows of alginate and calcium ions in the range of 2 mM to 40 mM into contact. The resulting growth of a gel bar is used to enclose and immobilize yeast cells. Adding ethylenediaminetetraacetic acid (EDTA) to the alginate solution allows for control of the hydrogel growth, and by varying the ratio of Ca(2+) to EDTA concentrations gel growth or gel shrinkage can be induced at will. Trapped cells are released during shrinkage of the gel. The trapping efficiency for different cell speeds is investigated and the properties of gel growth are discussed using a diffusion model. Precise positioning of a single cell is demonstrated. The technique presented allows not only the reversible immobilization of cells under gentle conditions but also offers the potential of long-term cell cultures as shown by on-chip incubation of yeast cells. The procedure may provide a simple and fully biocompatible technique for a multitude of innovative experiments on cells in microsystems.

Alginates↗

Batch-mode mixing on centrifugal microfluidic platforms.

We present two novel fluidic concepts to drastically accelerate the process of mixing in batch-mode (stopped-flow) on centrifugal microfluidic platforms. The core of our simple and robust setup exhibits a microstructured disk with a round mixing chamber rotating on a macroscopic drive unit. In the first approach, magnetic beads which are prefilled into the mixing chamber are periodically deflected by a set of permanent magnets equidistantly aligned at spatially fixed positions in the lab-frame. Their radial positions alternatingly deviate by a slight positive and negative offset from the mean orbit of the chamber to periodically deflect the beads inbound and outbound during rotation. Advection is induced by the relative motion of the beads with respect to the liquid which results from the magnetic and centrifugal forces, as well as inertia. In a second approach--without magnetic beads--the disk is spun upon periodic changes in the sense of rotation. This way, inertia effects induce stirring of the liquids. As a result, both strategies accelerate mixing from about 7 minutes for mere diffusion to less than five seconds. Combining both effects, an ultimate mixing time of less than one second could be achieved.

Centrifugation↗

Thermal optimisation of the Reimer-Tiemann reaction using thermochromic liquid crystals on a microfluidic reactor.

Microreactors incorporating thin film resistive heating elements for continuous flow organic synthesis are presented. Internal thermal conditions were monitored in real time using reflectance spectra of temperature sensitive thermochromic liquid crystals (TLC) in a collateral microfluidic network. To demonstrate the precise temperature control provided by this method, the thermal optimisation of the Reimer-Tiemann formylation of beta-naphthol was performed under hydrodynamic pumping regimes.

Crystallization↗

A microfluidic device using a green organic light emitting diode as an integrated excitation source.

A simply fabricated microfluidic device using a green organic light emitting diode (OLED) and thin film interference filter as integrated excitation source is presented and applied to fluorescence detection of proteins. A layer-by-layer compact system consisting of glass/PDMS microchip, pinhole, excitation filter and OLED is designed and equipped with a coaxial optical fiber and for fluorescence detection a 300 microm thick excitation filter is employed for eliminating nearly 80% of the unwanted light emitted by OLEDs which has overlaped with the fluorescence spectrum of the dyes. The distance between OLED illuminant and microchannels is limited to approximately 1 mm for sensitive detection. The achieved fluorescence signal of 300 microM Rhodamine 6G is about 13 times as high as that without the excitation filter and 3.5 times the result of a perpendicular detection structure. This system has been used for fluorescence detection of Rhodamine 6G, Alexa 532 and BSA conjugates in 4% linear polyacrymide (LPA) buffer (in 1 x TBE, pH 8.3) and 1.4 fmol and 35 fmol mass detection limits at 0.7 nl injection volume for Alexa and Rhodamine dye have been obtained, respectively.

Acrylic Resins↗

An automated electrokinetic continuous sample introduction system for microfluidic chip-based capillary electrophoresis.

An automated and continuous sample introduction system for microfluidic chip-based capillary electrophoresis (CE) was developed in this work. An efficient world-to-chip interface for chip-based CE separation was produced by horizontally connecting a Z-shaped fused silica capillary sampling probe to the sample loading channel of a crossed-channel chip. The sample presentation system was composed of an array of bottom-slotted sample vials filled alternately with samples and working electrolyte, horizontally positioned on a programmable linearly moving platform. On moving the array from one vial to the next, and scanning the probe, which was fixed with a platinum electrode on its tip, through the slots of the vials, a series of samples, each followed by a flow of working electrolyte was continuously introduced electrokinetically from the off-chip vials into the sample loading channel of the chip. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine and phenylalanine with LIF detection, by continuously introducing a train of different samples. Employing 4.5 kV sampling voltage (1000 V cm(-1) field strength) for 30 s and 1.8 kV separation voltage (400 V cm(-1) field strength) for 70 s, throughputs of 36 h(-1) were achieved with <1.0% carryover and 4.6, 3.2 and 4.0% RSD for arginine, FITC and phenylalanine, respectively (n = 11). Net sample consumption was only 240 nL for each sample.

Electrophoresis, Capillary↗

Microfluidic capturing-dynamics of paramagnetic bead suspensions.

We study theoretically the capturing of paramagnetic beads by a magnetic field gradient in a microfluidic channel treating the beads as a continuum. Bead motion is affected by both fluidic and magnetic forces. The transfer of momentum from beads to the fluid creates an effective bead-bead interaction that greatly aids capturing. We demonstrate that for a given inlet flow speed a critical density of beads exists above which complete capturing takes place.

Magnetics↗

Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays.

We present a soft lithographic method to fabricate multiphenotype cell arrays by capturing cells within an array of reversibly sealed microfluidic channels. The technique uses reversible sealing of elastomeric polydimethylsiloxane (PDMS) molds on surfaces to sequentially deliver various fluids or cells onto specific locations on a substrate. Microwells on the substrate were used to capture and immobilize cells within low shear stress regions inside channels. By using an array of channels it was possible to deposit multiple cell types, such as hepatocytes, fibroblasts, and embryonic stem cells, on the substrates. Upon formation of the cell arrays on the substrate, the PDMS mold could be removed, generating a multiphenotype array of cells. In addition, the orthogonal alignment and subsequent attachment of a secondary array of channels on the patterned substrates could be used to deliver fluids to the patterned cells. The ability to position many cell types on particular regions within a two dimensional substrate could potentially lead to improved high-throughput methods applicable to drug screening and tissue engineering.

Cell Adhesion↗

Thermally-actuated, phase change flow control for microfluidic systems.

An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself-the freezing and melting of a portion of a liquid slug-to noninvasively close and open flow passages (referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.

Microfluidic Analytical Techniques↗

Microfluidic device as a new platform for immunofluorescent detection of viruses.

A bead-based microfluidic device was developed and demonstrated to achieve rapid and sensitive enzyme-linked immunosorbent assay (ELISA) with quantum dots as the labeling fluorophore for virus detection. In comparison to standard ELISA performed on the same virus, the minimal detectable concentration of the target virus was improved from 360 to 22 ng mL-1, the detection time was shortened from >3.25 h to <30 min, and the amount of antibody consumed was reduced by a factor of 14.3.

Animals↗

New replication technique for the fabrication of thin polymeric microfluidic devices with tunable porosity.

In this article we present a new versatile replication method to produce thin polymeric microfluidic devices with tunable porosity. This method is based on phase separation of a polymer solution on a microstructured mold. Compared to existing microfabrication techniques, such as etching and hot embossing, our technique offers four advantages: (a) simple and cheap process that can be performed at room temperature outside clean room facilities; (b) very broad range of applicable materials (including materials that could not be processed before); (c) ability to make thin flexible chips; (d) ability to introduce and tune porosity in the chip. By introducing porosity, the channel walls can be used for selective transport of gasses, liquids and solutes. A proof-of-concept will be given, by showing fast CO2 transport through the channel walls of a porous polymer chip. Furthermore, it will be demonstrated that the gas permeation performance of chips can be enhanced dramatically by a decrease in chip thickness and incorporation of porosity. We expect that the development of porous chips can lead to the on-chip integration of multiple unit operations, such as reaction, separation, gas liquid contacting and membrane emulsification.

Carbon Dioxide↗

Hydrodynamic filtration for on-chip particle concentration and classification utilizing microfluidics.

We propose here a new method for continuous concentration and classification of particles in microfluidic devices, named hydrodynamic filtration. When a particle is flowing in a microchannel, the center position of the particle cannot be present in a certain distance from sidewalls, which is equal to the particle radius. The proposed method utilizes this fact, and is performed using a microchannel having multiple side branch channels. By withdrawing a small amount of liquid repeatedly from the main stream through the side channels, particles are concentrated and aligned onto the sidewalls. Then the concentrated and aligned particles can be collected according to size through other side channels (selection channels) in the downstream of the microchannel. Therefore, continuous introduction of a particle suspension into the microchannel enables both particle concentration and classification at the same time. In this method, the flow profile inside a precisely fabricated microchannel determines the size limit of the filtered substances. So the filtration can be performed even when the channel widths are much larger than the particle size, without the problem of channel clogging. In this study, concentrations of polymer microspheres with diameters of 1-3 microm were increased 20-50-fold, and they were collected independently according to size. In addition, selective enrichment of leukocytes from blood was successfully performed.

Cell Separation↗

Handheld recirculation system and customized media for microfluidic cell culture.

A palm-sized microfluidic recirculation system and customized media enable simplified long-term culture and imaging of cells. The combination of bare Braille display modules, a leveled monolithic surface for complete chip mounting, and a transparent heater improved portability, mechanical stability and optical accessibility. Modification of basal culture media with Leibovitz's L-15 medium enabled an incubator-free culture of carbonate-dependent cells by eliminating the need for exogenous carbon dioxide. This capability is demonstrated through time-lapse recording of proliferation of C2C12 myoblasts and MC3T3-E1 osteoblasts for over 2 weeks in ambient atmosphere without medium exchange. The method opens up new possibilities for portable cell culture and for long-term continuous visual monitoring of cells.

Cell Culture Techniques↗

Microfluidic arrays for logarithmically perfused embryonic stem cell culture.

We present a microfluidic device for culturing adherent cells over a logarithmic range of flow rates. The device sets flow rates through four separate cell-culture chambers using syringe-driven flow and a network of fluidic resistances. The design is easy to fabricate with no on-chip valves and is scalable both in the number of culture chambers as well as in the range of applied flow rates. Using particle velocimetry, we have characterized the flow-rate range. We have also demonstrated an extension of the design that combines the logarithmic flow-rate functionality with a logarithmic concentration gradient across the array. Using fluorescence measurements we have verified that a logarithmic concentration gradient was established in the extended device. Compared with static cell culture, both devices enable greater control over the soluble microenvironment by controlling the transport of molecules to and away from the cells. This approach is particularly relevant for cell types such as embryonic stem cells (ESCs) which are especially sensitive to the microenvironment. We have demonstrated for the first time culture of murine ESCs (mESCs) in continuous, logarithmically scaled perfusion for 4 days, with flow rates varying >300x across the array. Cells grown in the slowest flow rate did not proliferate, while colonies grown in higher flow rates exhibited healthy round morphology. We have also demonstrated logarithmically scaled continuous perfusion culture of 3T3 fibroblasts for 3 days, with proliferation at all flow rates except the slowest rate.

3T3 Cells↗

Integrated microfluidic UV absorbance detector with attomol-level sensitivity for BSA.

An integrated UV absorbance detection system employing a novel silicon-in-plastic technology to seamlessly integrate bare UV photodiode chips into polymer microfluidic systems has been developed. Detection platforms fabricated using this approach exhibit exceptionally low concentration and mass detection limits down to 15 nM and 9.8 amol, respectively, for bovine serum albumin (BSA) as a model protein. In addition to providing high sensitivity, sub-nanoliter detection volumes are enabled by the use of direct photodiode integration. The fabrication methodology is detailed, and system performance metrics including detection limits, detection volume, dynamic range, and linearity are reported.

Animals↗

Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients.

Experimental systems that provide temporal and spatial control of chemical gradients are required for probing into the complex mechanisms of eukaryotic cell chemotaxis. However, no current technique can simultaneously generate stable chemical gradients and allow fast gradient changes. We developed a microfluidic system with microstructured membranes for exposing neutrophils to fast and precise changes between stable, linear gradients of the known chemoattractant Interleukin-8 (IL-8). We observed that rapidly lowering the average concentration of IL-8 within a gradient, while preserving the direction of the gradient, resulted in temporary neutrophil depolarization. Fast reversal of the gradient direction while increasing or decreasing the average concentration also resulted in temporary depolarization. Neutrophils adapted and maintained their directional motility, only when the average gradient concentration was increased and the direction of the gradient preserved. Based on these observations we propose a two-component temporal sensing mechanism that uses variations of chemokine concentration averaged over the entire cell surface and localized at the leading edge, respectively, and directs neutrophil responses to changes in their chemical microenvironment.

Chemotaxis↗

Alternating droplet generation and controlled dynamic droplet fusion in microfluidic device for CdS nanoparticle synthesis.

A multifunctional and high-efficiency microfluidic device for droplet generation and fusion is presented. Through unique design of the micro-channels, the device is able to alternately generate droplets, generating droplet ratios ranging from 1 ratio 5 to 5 ratio 1, and fuse droplets, enabling precise chemical reactions in several picoliters on a single chip. The controlled fusion is managed by passive control based on the channel geometry and liquid phase flow. The synthesis of CdS nanoparticles utilizing each fused droplet as a microreactor for rapid and efficient mixing of reagents is demonstrated in this paper. Following alternating droplet generation, the channel geometry allows the exclusive fusion of alternate droplets with concomitant rapid mixing and produces supersaturated solution of Cd2+ and S2- ions to form CdS nanoparticles in each fused droplet. The spectroscopic properties of the CdS nanoparticles produced by this method are compared with CdS prepared by bulk mixing.

Cadmium Compounds↗

Electronic drop sensing in microfluidic devices: automated operation of a nanoliter viscometer.

We describe three droplet sensing techniques: a digital electrode, an analog electrode, and a thermal method. All three techniques use a single layer of metal lines that is easy to microfabricate and an electronic signal can be produced using low DC voltages. While the electrode methods utilize changes in electrical conductivity when the air/liquid interface of the droplet passes over a pair of electrodes, the thermal method is based on convective heat loss from a locally heated region. For the electrode method, the analog technique is able to detect 25 nL droplets while the digital technique is capable of detecting droplets as small as 100 pL. For thermal sensing, temperature profiles in the range of 36 degrees C and higher were used. Finally, we have used the digital electrode method and an array of electrodes located at preset distances to automate the operation of a previously described microfluidic viscometer. The viscometer is completely controlled by a laptop computer, and the total time for operation including setup, calibration, sample addition and viscosity calculation is approximately 4 minutes.

Electrodes↗