PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Mobile Applications”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Feasibility of enhancing high-performance liquid chromatography using microwave radiation.

High-performance liquid chromatography (HPLC) is the most versatile of the chromatographic techniques because it is applicable to a wide variety of analytes. Unfortunately, liquid mobile phases have relatively low diffusivities. A novel approach is presented for increasing the diffusivity of a liquid mobile phase. The method advocated in this study is the first process that has been described by which it is possible to increase the diffusivity of a liquid while having essentially no effect on other physical properties of the liquid, such as the temperature or solvating power. It is demonstrated that it is possible to sharpen peaks, in an HPLC separation, by the application of microwave radiation.

Journal Article↗

Cholinergic stimulation of human microcytoma cell line H69.

Experiments were addressed to investigate the mechanisms by which cholinergic stimulation is coupled to the enhancement of proliferation of small cell lung cancer cells H69. Muscarinic stimulation triggers the release of cytosolic Ca2+ and of inositol(1,4,5)trisphosphate with comparable time courses. The presence of alpha-bungarotoxin or the absence of Ca2+ in external medium suppresses enhancement of clonal growth induced by brief applications of nicotine. Here we suggest that Ca2+ mobilization represents a trigger for the enhancement of small cell lung cancer cell proliferation upon cholinergic stimulation.

Acetylcholine↗

Direct and indirect electroosmotic flow velocity measurements in microchannels.

As microfluidic technologies mature, increasingly complex solutions are employed, and accurate methods for the measurement of electroosmotic flow rates are becoming increasingly important. The methodologies of both a direct method and an indirect method of flow rate measurement are presented here. The direct method involves flow visualization using trace amounts of a caged fluorescent dye. The indirect method is based on the change in current that occurs when one solution in the microchannel is replaced by another. The results of concurrent and independent measurements of electroosmotic velocities of Tris-acetate with EDTA (TAE) and Tris-borate with EDTA (TBE) at 1x concentration in fused silica capillaries are presented. Although these buffers are commonly used in biological chemistry, these mobilities have not previously been reported. Strong agreement among data collected with both methods establishes confidence in the electroosmotic mobility values obtained and indicates that the current-based method, which requires less infrastructure than the direct method, can provide accurate flow rate measurements under these conditions. Constant electroosmotic mobilities of 4.90 x 10(-8) m(2) V(-1) s(-1) for TAE and 3.10 x 10(-8) m(2) V(-1) s(-1) for TBE were determined by tests in a range of electrical field strengths from 5 to 20 kV/m. A linear flow rate increase with applied field strength indicated that constant mobility and negligible Joule heating effects were present. Applicability and limitations of both the measurement methods and these buffers are discussed in the context of microfluidic applications.

Journal Article↗

[Dynamics of protein structures].

This review presents a survey of experimental and theoretical methods capable of providing a many-parameter characterization of internal mobility of protein molecules. Special emphasis is on applications of high-resolution nuclear magnetic resonance for studies of non-crystalline proteins and discussions of possible correlations between protein dynamics and biological functions of proteins.

Amino Acid Sequence↗

Hydrogen storage methods.

Hydrogen exhibits the highest heating value per mass of all chemical fuels. Furthermore, hydrogen is regenerative and environmentally friendly. There are two reasons why hydrogen is not the major fuel of today's energy consumption. First of all, hydrogen is just an energy carrier. And, although it is the most abundant element in the universe, it has to be produced, since on earth it only occurs in the form of water and hydrocarbons. This implies that we have to pay for the energy, which results in a difficult economic dilemma because ever since the industrial revolution we have become used to consuming energy for free. The second difficulty with hydrogen as an energy carrier is its low critical temperature of 33 K (i.e. hydrogen is a gas at ambient temperature). For mobile and in many cases also for stationary applications the volumetric and gravimetric density of hydrogen in a storage material is crucial. Hydrogen can be stored using six different methods and phenomena: (1) high-pressure gas cylinders (up to 800 bar), (2) liquid hydrogen in cryogenic tanks (at 21 K), (3) adsorbed hydrogen on materials with a large specific surface area (at T<100 K), (4) absorbed on interstitial sites in a host metal (at ambient pressure and temperature), (5) chemically bonded in covalent and ionic compounds (at ambient pressure), or (6) through oxidation of reactive metals, e.g. Li, Na, Mg, Al, Zn with water. The most common storage systems are high-pressure gas cylinders with a maximum pressure of 20 MPa (200 bar). New lightweight composite cylinders have been developed which are able to withstand pressures up to 80 MPa (800 bar) and therefore the hydrogen gas can reach a volumetric density of 36 kg.m(-3), approximately half as much as in its liquid state. Liquid hydrogen is stored in cryogenic tanks at 21.2 K and ambient pressure. Due to the low critical temperature of hydrogen (33 K), liquid hydrogen can only be stored in open systems. The volumetric density of liquid hydrogen is 70.8 kg.m(-3), and large volumes, where the thermal losses are small, can cause hydrogen to reach a system mass ratio close to one. The highest volumetric densities of hydrogen are found in metal hydrides. Many metals and alloys are capable of reversibly absorbing large amounts of hydrogen. Charging can be done using molecular hydrogen gas or hydrogen atoms from an electrolyte. The group one, two and three light metals (e.g. Li, Mg, B, Al) can combine with hydrogen to form a large variety of metal-hydrogen complexes. These are especially interesting because of their light weight and because of the number of hydrogen atoms per metal atom, which is two in many cases. Hydrogen can also be stored indirectly in reactive metals such as Li, Na, Al or Zn. These metals easily react with water to the corresponding hydroxide and liberate the hydrogen from the water. Since water is the product of the combustion of hydrogen with either oxygen or air, it can be recycled in a closed loop and react with the metal. Finally, the metal hydroxides can be thermally reduced to metals in a solar furnace. This paper reviews the various storage methods for hydrogen and highlights their potential for improvement and their physical limitations.

Alloys↗

A new hemostatic puncture closure device for the immediate sealing of arterial puncture sites.

After angiography, 6 to 24 hours of bedrest is indicated to assure that adequate hemostasis of the femoral artery has been achieved. Recently, a new hemostatic puncture closure device (HPCD) has been developed, which consists of a resorbable polymer anchor, a resorbable suture, a small collagen plug and an 8Fr delivery device. The device is delivered into the femoral artery through the introducer sheath, the anchor is secured against the intraluminal artery wall, and the collagen plug is deployed on the arterial wall. The prototype of the HPCD was used in 20 patients administered heparin. After insertion of the HPCD, hemostasis was achieved in 1.2 +/- 2.1 minutes; in 2 patients a light pressure dressing was applied for 4 hours to stop oozing. No late bleeding occurred. In 1 patient the positioning suture broke, requiring the application of a pressure bandage. Patients were uneventfully mobilized after 6.7 +/- 3.5 hours. In all patients serial duplex scanning of the femoral artery was performed before and after 1, 7, 30 and 90 days after HPCD placement. In 5 patients a small subcutaneous hematoma close to the site of introduction could be detected by ultrasound 1 day after catheterization. All but 1 patient had normalization of the flow patterns in the femoral artery. It is concluded that: (1) the HPCD is an effective device to achieve immediate hemostasis after arterial catheterization despite antithrombotic therapy, (2) early mobilization was uneventful, (3) duplex ultrasound studies demonstrated only transient changes in the punctured femoral artery, and (4) further investigations are needed to establish the efficacy and safety of the device.

Equipment Design↗

Are hard-copy prints from peroperative fluoroscopy images useful as documentation?

We have examined the applicability of peroperative image documentation, in promoting early mobilization after osteosynthesis and saving the standard X-ray examination. One hundred and twenty-three patients with proximal femoral fractures were included in the investigation. Hard-copy reprints were recorded from peroperative fluoroscopy images by Fuji Film Thermal Imaging System FTI 200. These reprints were compared with the standard X-rays to assess the quality of the osteosynthesis and possible restriction in mobilization. The specificity of finding an unstable osteosynthesis was 0.40, whereas the sensitivity of finding a stable osteosynthesis was 0.96. In all, four unstable osteosyntheses were overlooked on the hard copy reprints. The specificity of finding patients in need of restricted mobilization was 0.44 and the sensitivity of finding patients allowed free mobilization was 0.93. Eight patients needing restricted mobilization were overlooked on the reprints. Hard-copy images do not safely reveal unstable osteosynthesis and cannot replace the standard X-rays taken postoperatively.

Fluoroscopy↗

Pseudo-electrochromatography--negative-ion electrospray mass spectrometry of aromatic glucuronides and food colours.

Pseudo-electrochromatography is a combination of liquid chromatography and an electromigration technique, especially directed at the separation of ionic compounds prior to mass spectrometric detection with a mobile phase composition compatible with mass spectrometry. The application of pseudo-electrochromatography to the separation of food colours and aromatic glucuronides is described. An example of selectivity tuning by applying voltages of differing polarity during the chromatographic run is given. The coupling of pseudo-electrochromatography with electrospray mass spectrometry is demonstrated. Differences in the effects of the axial potential over the column between silica-based and polymeric packing materials are discussed.

Chromatography↗

A procedure to measure the specific activities of dopamine and its metabolites in rat striatum, based on HPLC, electrochemical detection and liquid scintillation counting.

A procedure to determine the specific activities (s.a.) of the putative neurotransmitter dopamine (DA) and its metabolites in rat striatum is described. For this purpose 200 mu Ci L-[3,5-3H]tyrosine was injected via a jugular vein cannula into freely moving rats. Contents and radioactivity of striatal tyrosine, DA, 3,4-dihydroxyphenylacetic acid (DOPAC), 3-methoxytyramine (3-MT) and homovanillic acid (HVA) were determined by means of HPLC, electrochemical detection (ECD) and liquid scintillation counting. In the phase system applied DA, DOPAC, 3-MT and HVA can be separated in a single run after direct injection of striatal supernatants. The selectivity of the phase system was sufficient to analyse the supernatant of two rat striata over a 150 X 4.6 mm column, even when DA turnover was strongly stimulated. Tyrosine levels and radioactivity were measured by re-analysis of the front peak with divergent mobile phase parameters. In order to demonstrate the applicability of the present procedure, the s.a. of DA and its metabolites, as found 20 min after [3H]tyrosine administration, and the effect of haloperidol thereupon, are presented.

3,4-Dihydroxyphenylacetic Acid↗

Resolution of the stereoisomers of baclofen by high performance liquid chromatography.

The GABA analogue baclofen [3-(p-chlorophenyl)-4-aminobutanoic acid] has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies.

Baclofen↗

Indirect UV detection of hydrophilic ionized compounds in reversed-phase liquid chromatography by use of a UV-absorbing ion of the same charge.

Ion-pair reversed-phase liquid chromatographic systems have been developed that allow the detection and quantitation of low amounts of hydrophilic ionized substances, which otherwise display little or no capability for optical detection. The mobile phase contains a UV-absorbing ion of the same charge and hydrophobic character as the samples, most often together with a hydrophobic counter-ion to give the samples suitable retention; the stationary phase consists of octadecylsilica. Chromatograms featuring two system peaks are usually obtained, and these give rise to some deviations from the usual response pattern. In the present work the influence on retention and detection sensitivity of the non-absorbing counter-ion, the UV-absorbing ion and the uncharged organic modifier have been studied systematically. Principles for optimizing the detector response by changing the mobile phase composition have been deduced. Examples of applications of the indirect detection technique to the analysis of hydrophilic compounds of pharmaceutical and biological interest, such as amino acids, water-soluble vitamins and piperazine, are presented.

Journal Article↗

Calcium signals and the in vitro migration of chick ciliary ganglion cells.

We have studied calcium signals and their role in the migration of neuronal and nonneuronal cells of embryonic chick ciliary ganglion (CG). In vitro, neurons migrate in association with nonneuronal cells to form cellular aggregates. Changes in the modulus of the velocity of the neuron-nonneuronal cell complex were observed in response to treatments that increased or decreased intracellular calcium concentration. In addition, both cell types generated spontaneous calcium activity that was abolished by removal of extracellular calcium. Calcium signals in neurons could be characterized as either spikes or waves. Neuronal spikes were found to be related to action potential generation whereas neuronal waves were due to voltage-independent calcium influx. Nonneuronal cells generated calcium oscillations that were dependent on calcium release from intracellular stores and on voltage-independent calcium influx. Application of thimerosal, a compound that stimulates calcium mobilization from internal stores, increased: (1) the amplitude of spontaneous nonneuronal oscillations; (2) the area of migrating nonneuronal cells; and (3) the velocity of the neuronal-nonneuronal cell complex. We conclude that CG cell migration is a calcium dependent process and that nonneuronal cell calcium oscillations play a key role in the modulation of velocity.

Animals↗

Transport and anaerobic biodegradation of propylene glycol in gravel-rich soil materials.

Continued input of airplane de-icing/anti-icing fluids (ADAF) to runway adjacent soils may result in the depletion of soil-borne terminal electron acceptors. We studied the transport and transformation of propylene glycol (PG), the major constituent of many ADAF, in topsoil and subsoil samples using saturated column experiments at 4 degrees C and 20 degrees C. The export of soil-borne DOC was generally high, non-exhaustive and rate limited. Retardation of added PG was negligible. Rapid PG degradation was observed only in topsoil materials high in organic matter at 20 degrees C. At 4 degrees C, no significant degradation was observed. Thus, under unfavorable, i.e., wet and cold conditions typical for winter de-icing operations, PG and its metabolites will be relocated to deeper soil horizons or even to the groundwater. In subsoil materials, PG degradation was very slow and incomplete. We found that subsoil degradation depended on the import of active microorganisms originating from the organic-rich topsoil material. The degradation efficiency is strongly influenced by the flow velocity, i.e., the residence time of PG in the soil column. Poorly crystalline iron(III) and manganese(IV) (hydr)oxides are used during microbial respiration acting as terminal electron acceptors. This results in the formation and effective relocation of reduced and mobile Fe and Mn species. Long-term application of ADAF to runway adjacent soil as well as the lasting consumption of Fe and Mn will tend to decrease the soil redox potential. Without proper counteractive measures, this will eventually favor the development of methanogenic conditions.

Anaerobiosis↗

[Liquid chromatographic parameters of groups of herbicidal active substances. I. Urea herbicides].

Because of the polarity of herbicidal urea derivatives, liquid chromatography is the most suitable method for their determination. The separation of a number of active substances is described. A versatile applicable ternary solvent mixture is used as the mobile phase. Several columns are tested for their separation performances and their capability to retain active substances and some known degradation products. To fully utilize the sensitivity of the photometric detector the UV spectra of the tested compounds are determined.

Chromatography, Liquid↗

Development of an advanced rocket propellant handler's suit.

Most launch vehicles and satellites in the US inventory rely upon the use of hypergolic rocket propellants, many of which are toxic to humans. These fuels and oxidizers, such as hydrazine and nitrogen tetroxide have threshold limit values as low as 0.01 PPM. It is essential to provide space workers handling these agents whole body protection as they are universally hazardous not only to the respiratory system, but the skin as well. This paper describes a new method for powering a whole body protective garment to assure the safety of ground servicing crews. A new technology has been developed through the small business innovative research program at the Kennedy Space Center. Currently, liquid air is used in the environmental control unit (ECU) that powers the propellant handlers suit (PHE). However, liquid air exhibits problems with attitude dependence, oxygen enrichment, and difficulty with reliable quantity measurement. The new technology employs the storage of the supply air as a supercritical gas. This method of air storage overcomes all of three problems above while maintaining high density storage at relatively low vessel pressures (<7000 kPa or approximately 1000 psi). A one hour prototype ECU was developed and tested to prove the feasibility of this concept. This was upgraded by the design of a larger supercritical dewar capable of holding 7 Kg of air, a supply which provides a 2 hour duration to the PHE. A third version is being developed to test the feasibility of replacing existing air cooling methodology with a liquid cooled garment for relief of heat stress in this warm Florida environment. Testing of the first one hour prototype yielded data comparable to the liquid air powered predecessor, but enjoyed advantages of attitude independence and oxygen level stability. Thermal data revealed heat stress relief at least as good as liquid air supplied units. The application of supercritical air technology to this whole body protective ensemble marked an advancement in the state-of-the-art in personal protective equipment. Not only was long duration environmental control provided, but it was done without a high pressure vessel. The unit met human performance needs for attitude independence, oxygen stability and relief of heat stress. This supercritical air (and oxygen) technology is suggested for microgravity applications in life support such as the Extravehicular Mobility Unit.

Adult↗

Bisalbuminemia in two Croatian families.

BACKGROUND: Bisalbuminemia is a dysproteinemia characterized by the occurrence of two albumin fractions on serum protein separation by electrophoresis on cellulose acetate sheets. Bisalbuminemia may occur as a hereditary trait or as analytical interference with some drugs, especially penicillin. METHODS: Two patients with the finding of bisalbuminemia are presented. Both patients (patient 1 was a 4-1/2-month-old male infant, and patient 2 was a 15-year-old boy) were admitted for respiratory infection. RESULTS: Bisalbuminemia was detected by serum protein electrophoresis and confirmed by isoelectric focusing in pH gradient gel (pH range 4.0-6.5). This finding was supported by simultaneous detection of abnormal albumin in the mother of patient 1, while the father had normal albumin. The abnormal fast albumin in both patients had an increased relative mobility of 1.08 when measured from the sample application position. CONCLUSIONS: The results presented are the first description of albumin mutations in Croatia (that according to the CISMEL group could be classified as ZC/HZ), and present the first step in identification prior to determination of structural change and amino acid sequence in the albumin molecule.

Adolescent↗

Identification of the cockroach neuropeptide Pea-CAH-II as a second adipokinetic hormone in the firebug Pyrrhocoris apterus.

A new member of the AKH/RPCH family was isolated from the corpora cardiaca of the firebug Pyrrhocoris apterus. It is the second adipokinetic peptide identified in this species. The peptide was characterized and its structure was deduced from the multiple MS(N) electrospray mass spectra as that of an octapeptide with the sequence pGlu-Leu-Thr-Phe-Thr-Pro-Asn-Trp-NH(2.) The peptide differs from the original P. apterus AKH (Pya-AKH) by one amino acid in position 3. Topical application and/or injection of the peptide induced lipid mobilization, but was inactive in mobilization of carbohydrates.

Animals↗