PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

A solid-phase microextraction chamber method for analysis of manure volatiles.

Odors from livestock operations are a complex mixture of volatile carbon, sulfur, and nitrogen compounds. Currently, detailed volatiles analysis is both time consuming and requires specialized equipment and methods. This work describes a new method that utilizes a dynamic flux chamber, solid-phase microextraction (SPME), and gas chromatography-mass spectroscopy (GC-MS) to describe and compare the odorous compounds emitted from cattle and swine feces. Evaluation of method parameters produced a protocol for comparing relative emissions based on fixed sample temperature (20 degrees C) and exposed surface area (approximately 523 cm(2)), air flow rates (1 L min(-1) or 16 cm s(-1)), SPME exposure time (5 min), and chamber cleaning procedures (70% ethanol rinse and drying for 30 min at 105 degrees C) to minimize cross-contamination between samples. A variety of volatile organic compounds (VOCs) including alcohols, volatile fatty acids, aromatic ring compounds, ketones, esters, and sulfides were routinely detected and the relative emissions from fresh and incubated (37 degrees C overnight) swine and cattle feces were compared as a measure of potential to produce odorants during manure storage. Differences in the types and relative quantities of volatiles emitted were detected when animal species (cattle or swine), diet, fecal incubation, or sample storage conditions (20, 4, or -20 degrees C) were varied.

Animals↗

Applications of solid-phase microextraction in food analysis.

Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC-mass spectrometry (GC-MS), high-performance liquid chromatography (HPLC) or LC-MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC-MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.

Food Analysis↗

Solid-phase microextraction of organophosphorus pesticides from water.

Frequent occurrences of pollution in natural drainage by industrial chemicals, especially pesticides, have triggered interest in the development of fast and unambiguous analytical techniques to verify these pollutants in order to facilitate rapid remedial actions. In this work, we report the development of a solid-phase microextraction (SPME) method to analyse two common industrial pesticides in water, i.e. malathion and parathion. SPME analysis facilitates direct analysis of chemical species in aqueous systems and avoids lengthy sample preparation procedures. In this study, we compare five commercially available fibres: 7 microns polydimethylsiloxane, 30 microns polydimethylsiloxane. 85 microns polyacrylate, 65 microns Carbowax-divinylbenzene and 65 microns polydimethylsiloxane-divinylbenzene fibres. Profiles of uptake by the fibres against adsorption times were established. The results obtained indicated that the polarity of the fibres is not the main factor affecting the uptake. The structures of the fibres also affected the permeation of the analytes onto the fibres. The limits of detection were determined to be in the low ppb level with a flame ionization detector. These methods have great potential for use in rapid on-site analytical work which is highly demanded in environmental studies.

Chemical Phenomena↗

Negligible depletion solid-phase microextraction with radiolabeled analytes to study free concentrations and protein binding: an example with [3H]estradiol.

A new method is presented that enables sensitive measurement of free concentrations of radiolabeled ligands. Additionally, protein binding of radiochemicals in complex matrixes can be determined with this new technique that combines negligible depletion solid-phase microextraction (nd-SPME) with liquid scintillation counting (LSC) as detection. [3H]Estradiol was taken as an example compound. Possible matrix effects of protein on fiber uptake kinetics were studied. No matrix effect was found, either by fouling of the fiber, or by changed uptake kinetics. The validity of the method was shown in the determination of the affinity constant (Ka) of estradiol for human serum albumin (HSA). The Ka was estimated at 8.9 x 10(4) M(-1), which corresponds well with literature values. This study shows that nd-SPME is suitable to study the free concentration and protein binding of [3H]estradiol. The method described in this paper combines the advantages of nd-SPME with the advantages of radiolabeled analytes, creating a timesaving, simple, and sensitive analytical tool that will be particularly useful in complex matrixes containing many potential interferences for chromatographic methods.

Estradiol↗

Plant-assisted degradation of phenanthrene as assessed by solid-phase microextraction (SPME).

The soil bacterium Sphingomonas yanoikuyae was isolated from a petroleum-contaminated soil and grown on mineral salts agar overlaid with the polycyclic aromatic hydrocarbon phenanthrene. The effect of white mustard, Sinapis alba, on phenanthrene degradation by S. yanoikuyae in artificially contaminated Redi-earth-sand was examined. Solid-phase-microextraction (SPME) gas chromatography-flame ionization detection (GC-FID) was used to quantify the concentration of phenanthrene in the gas phase of Magenta jars containing S. alba and S. yanoikuyae, each alone and with no additions. Gas chromatography-mass spectrometry (GC-MS) of Soxhlet extracts was used to determine the concentration of phenanthrene remaining in Redi-earth-sand. The gas phase concentration of phenanthrene in nonsterile Redi-earth-sand decreased by 99.7% in treatments with S. alba plus S. yanoikuyae, by 98.6% with S. alba, by 96.7% with S. yanoikuyae, and by 95.8% with no additions. Under gnotobiotic conditions, the gas phase concentration of phenanthrene in Redi-earth-sand decreased by 94% in treatments with S. alba plus S. yanoikuyae, by 77% with S. yanoikuyae, by 26% with S. alba, and 0% with no additions. The concentration of phenanthrene in Redi-earth-sand under gnotobiotic conditions decreased in treatments with S. alba plus S. yanoikuyae by 88%, by 67% with S. yanoikuyae, by 13% with S. alba, and 0% with no additions as measured in Soxhlet extracts. These results suggest that SPME-GC can be used to rapidly assess the potential of plants and microorganisms to reduce the level of unaged polyaromatic hydrocarbons such as phenanthrene in soil. This method provided results that were consistent with the more costly Soxhlet extraction method and was less time consuming.

Biodegradation, Environmental↗

Automated headspace solid-phase microextraction and in-matrix derivatization for the determination of amphetamine-related drugs in human urine by gas chromatography-mass spectrometry.

An automated extraction and determination method for the gas chromatography (GC)-mass spectrometry (MS) analysis of amphetamine-related drugs in human urine is developed using headspace solid-phase microextraction (SPME) and in-matrix derivatization. A urine sample (0.5 mL, potassium carbonate (5 M, 1.0 mL), sodium chloride (0.5 g), and ethylchloroformate (20 microL) are put in a sample vial. Amphetamine-related drugs are converted to ethylformate derivatives (carbamates) in the vial because amphetamine-related drugs in urine are quickly reacted with ethylchloroformate. An SPME fiber is then exposed at 80 degrees C for 15 min in the headspace of the vial. The extracted derivatives to the fiber are desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves show linearity in the range of 1.0 to 1000 ng/mL for methamphetamine, fenfluramine, and methylenedioxymethamphetamine; 2.0 to 1000 ng/mL for amphetamine and phentermine; 5.0 to 1000 ng/mL for methylenedioxyamphetamine; 10 to 1000 ng/mL for phenethylamine; and 50 to 1000 ng/mL for 4-bromo-2,5-dimethoxyphenethylamine in urine. No interferences are found, and the time for analysis is 30 min for one sample. Furthermore, this proposed method is applied to some clinical and medico-legal cases by taking methamphetamine. Methamphetamine and its metabolite amphetamine are detected in the urine samples collected from the patients involved in the clinical cases. Methamphetamine, amphetamine, and phenethylamine are detected in the urine sample collected from the victim of a medico-legal case.

Amphetamine-Related Disorders↗

Measurement of trihalomethanes and methyl tertiary-butyl ether in tap water using solid-phase microextraction GC-MS.

The prevalence of water disinfection byproducts in drinking water supplies has raised concerns about possible health effects from chronic exposure to these compounds. To support studies exploring the relation between exposure to trihalomethanes (THMs) and health effects, we have developed an automated analytical method using headspace solid-phase microextraction coupled with capillary gas chromatography and mass spectrometry. This method quantitates trace levels of THMs (chloroform, bromodichloromethane, dibromochloromethane, and bromoform) and methyl tertiary-butyl ether in tap water. Detection limits of less than 100 ng/L for all analytes and linear ranges of three orders of magnitude are adequate for measuring the THMs in tap water samples tested from across the United States. THMs are stable for extended periods in tap water samples after quenching of residual chlorine and buffering to pH 6.5, thus enabling larger epidemiologic field studies with simplified sample collection protocols.

Gas Chromatography-Mass Spectrometry↗

A simple method for the extraction of volatile organic compounds contained in air samples from adsorbent materials by solid phase microextraction and their analysis by gas chromatography/mass spectrometry.

The monitoring of air pollution requires simple, rapid and sensitive sampling and analytical techniques with minimal sample manipulation that are usable for routine analyses. In our laboratories we have developed a method for the analysis of air samples collected by adsorbent cartridges based on solid phase microextraction (SPME) coupled to gas chromatography/mass spectrometry. We investigated the influence of some variables (time and temperature) using toluene as analyte (one of the most common air pollutants) and toluene-d(8) on the SPME extraction, and the sensitivity (LOQ) of the method. We then tested the method on an air sample collected in an industrial area and carried out characterisation of the volatile organic compounds present.

Adsorption↗

Rapid determination of C6-aldehydes in tomato plant emission by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization.

A simple, rapid, sensitive, and solvent-free method was developed for determination of plant-signalling compounds, the three C6-aldehydes hexanal, (Z)-3-hexenal, and (E)-2-hexenal, in tomato plant emission by gas chromatography-mass spectrometry (GC-MS) and solid-phase microextraction (SPME) with on-fiber derivatization. In this method, O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) in aqueous solution was first headspace adsorbed onto a 65 microm poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber at 25 degrees C for 5 min, and then the fiber with adsorbed PFBHA was used for headspace extraction of tomato plant emission at 25 degrees C for 6 min. Finally, the resulting oximes adsorbed on the fiber were desorbed and analyzed by GC-MS. Extraction conditions and method validation were studied. The proposed method had low detection limit values for the three aldehydes from 0.1 to 0.5 ng/L and good precision (RSD less than 10%). In this work, the method was applied to investigation of tomato plant defense response to Helicoverpa armigera.

Adsorption↗

Development of headspace solid-phase microextraction with on-fiber derivatization for determination of hexanal and heptanal in human blood.

Hexanal and heptanal in human blood have been regarded as potential biomarkers of lung cancer. Owing to their high volatilities and activities, it is difficult to accurately measure the two biomarkers. In the current work, headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization technique was developed for quantitative analysis of hexanal and heptanal in human blood. In the proposed method, the two aldehydes in blood were headspace extracted by using a poly (dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine (PFBHA) at 60 degrees C for 8 min. The aldehyde oximes formed on the fiber were desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). The method validations including detection limit, recovery and precision were studied. It was found that the method provided low detection limits of 0.006 nM for hexanal and 0.005 nM for heptanal, recoveries from 89% to 95% and R.S.D. values less than 8.5%. The present method was applied to quantitative analysis of hexanal and heptanal in normal blood and lung cancer blood. Hexanal concentrations from 7.33 to 15.23 microM and heptanal concentrations from 2.47 to 9.23 microM were found in the lung cancer blood, while both hexanal and heptanal in the control blood were lower than 0.6 microM. This further demonstrated that hexanal and heptanal might be the biomarkers of lung cancer. The experimental results showed that GC-MS and HS-SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for determination of in hexanal and heptanal human blood.

Aldehydes↗

Solid phase microextraction of alkenylbenzenes and other flavor-related compounds from tobacco for analysis by selected ion monitoring gas chromatography-mass spectrometry.

Some constituents found in natural flavorings are known to exhibit toxic properties. We developed a rapid method for quantifying 12 flavor-related compounds in cigarette tobacco using headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. Using selected ion monitoring, we quantified and positively identified coumarin; pulegone; piperonal and nine alkenylbenzenes, including trans-anethole, safrole, methyleugenol and myristicin in one or more brands of cigarettes. In 62% of 68 brands analyzed, we detected one or more of the flavor-related compounds ranging from 0.0018 to 43 microg/g. Toxic properties of these flavor-related compounds may constitute an additional health risk related to cigarette smoking.

Benzene Derivatives↗

Analysis of benzothiazole in Italian wines using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

Benzothiazoles are a part of the molecular structure of a large number of natural products, biocides, drugs, food flavors, and industrial chemicals. They also appear in the environment mainly as a result of their production and use as rubber vulcanization accelerators. A new headspace solid-phase microextraction (HS-SPME) method for analysis of benzothiazole (BTH) in wine is described. This method is fast, inexpensive, and does not require solvents. The detection limit of BTH in wine was 45 ppt with linearity up to 100 ppb. The quantification of BTH is performed by the standard additions method and does not require the use of an internal standard. We have analyzed 12 wines from different grape varieties grown in several regions, using SPME extraction and gas chromatography-mass spectrometry (GC-MS) detection. Under these experimental conditions, benzothiazole was found in all wines analyzed. Concentration levels in samples varied from 0.24 microg/L (Vermentino) to 1.09 microg/L (Franciacorta).

Benzothiazoles↗

Automated in-tube solid phase microextraction coupled with HPLC-ES-MS for the determination of catechins and caffeine in tea.

A polypyrrole (PPY) coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for catechins and caffeine. Compared with commercial capillaries that were currently used for in-tube solid phase microextraction (SPME), the PPY coated capillary showed better extraction efficiency for all of the compounds studied. Electrospray mass spectrometric (ES-MS) detection conditions were also investigated. After optimization of the extraction and detection conditions, a method for the sensitive and selective determination of catechins and caffeine was developed by coupling the PPY coated capillary in-tube SPME with HPLC-ES-MS. Catechins could be determined in both positive and negative ion detection modes. The detection limit (S/N = 3) for each of the studied catechins was < 0.5 ng mL-1. Caffeine could only be determined under positive ES-MS detection conditions and its detection limit was 0.01 ng mL-1. Caffeine and the five catechins in several tea samples were determined using the developed method. Small amounts of catechins were also detected in grape juice and wine samples.

Caffeine↗

A simple, rapid and sensitive method for determination of aldehydes in human blood by gas chromatography/mass spectrometry and solid-phase microextraction with on-fiber derivatization.

Aldehydes are considered potential markers for enhanced oxidative stress and have been proposed as a diagnostic measure of cancer status. Do to their volatility and activity, it is very difficult to accurately measure aldehydes in human blood. In the present work, gas chromatography/mass spectrometry (GC/MS) and solid-phase microextraction (SPME) with on-fiber derivatization was developed for determination of aldehydes in human blood. O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) in aqueous solution was first adsorbed by a SPME fiber, and then the aldehydes in blood samples were headspace extracted by the SPME fiber and rapidly derivatized with PFBHA on the SPME fiber. Finally, the oximes formed were desorbed and detected by GC/MS in electron ionization (EI) mode. Validation of the present method was carried out, and the method was applied to quantitative analysis of the aldehydes in lung cancer blood. The results demonstrated that GC/MS and SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for the determination of aldehydes in human blood.

Aldehydes↗

Determination of benzene at trace levels in air by a novel method based on solid-phase microextraction gas chromatography/mass spectrometry.

A new method for the determination of benzene at trace levels in air is presented. The method consists of the collection of air samples on adsorbent cartridges with simultaneous adsorption of pre-established amounts of D6-labeled internal standard. Desorption from the cartridge is performed by solid-phase microextraction (SPME) with analysis by gas chromatography/mass spectrometry (GC/MS) using an ion trap mass spectrometer. The influence of several parameters (type of SPME fiber, temperature, time, for example) was investigated, and good linearity in the range 10-400 ng of C6D6, with a coefficient of variance (CV) around 3-5%, was obtained. The method was tested by sampling air in a town center in Italy, and a benzene concentration of approximately 50 microg/m(3) was determined. The maximum limit recommended by the European Community is 10 microg/m(3).

Air Pollutants, Occupational↗

Gas chromatography-mass spectrometry with solid-phase microextraction method for determination of methyl salicylate and other volatile compounds in leaves of Lycopersicon esculentum.

Methyl salicylate (MeSA) in many plants is a important signaling compound, which plays an important role in a pathogen-induced defense response. In this paper, gas chromatography-mass spectrometry (GC-MS) with headspace solid-phase microextraction (HS-SPME) was developed for determination of MeSA and other volatile compounds in leaves of a tomato plant (Lycopersicon esculentum). Tomato leaves were ground under liquid nitrogen and sampled by HS-SPME, with a 100 microm polydimethylsiloxane fiber, and finally analyzed by GC-MS. Eighteen compounds in the leaves of tomato plant infested by tobacco mosaic virus (TMV) were separated and identified, among them MeSA, which was quantitatively analyzed by the standard addition method. MeSA concentrations higher than 2.0 microg g(-1) fresh weight accumulated in leaves of TMV-infested tomato plant as the defense response to TMV. A similar concentration of MeSA in the leaves of MeSA-treated tomato plant was also found. No MeSA in leaves of control tomato plant was detected. These findings suggest that MeSA might be a signaling compound in the tomato plant response to TMV. The present method for determination of MeSA required only simple sample preparation and no organic solvent, and provided an excellent relative standard deviation of less than 5.0% and a low detection limit of 10 ng g(-1) fresh weight for MeSA. These results show that GC-MS-HS-SPME is a simple, rapid and sensitive method for determination of MeSA and other plant-signaling compounds in plant tissues.

Gas Chromatography-Mass Spectrometry↗

Solid-phase microextraction coupled with capillary electrophoresis for the determination of propranolol enantiomers in urine using a sol-gel derived calix[4]arene fiber.

A new type of diglycidyloxy-calix[4]arene coated fiber made by sol-gel method was initially prepared for capillary electrophoresis (CE) sample pretreatment. By using headspace solid-phase microextraction (SPME) combined with a novel back-extraction facility coupled off-line to capillary zone electrophoresis (CZE), the simultaneous determination of propranolol enantiomers in human urine was achieved. The clean up effect and preconcentration effect were realized for the first time without derivatization during the SPME process in terms of these strong polarity and thermal stable compounds. Ultrasonic back-extraction and field amplified sample injection (FASI) technologies were employed. Extraction and back-extraction parameters were optimized. Preconcentration of the sample by calix[4]arene fiber based SPME and FASI increased the sensitivity, yielding a limit of detection (LOD) of 0.01microg/ml by CZE-diode array detection (DAD). Method repeatability (RSD<6.5%) and fiber reusability (>150 extraction procedures) were observed over a linear range (0.05-10microg/ml) in urine samples. Based on the superior thermal stability, high alkali- and solvent-resistant ability, marvelous repeatability and long lifetime of the novel fiber, this SPME-FASI-CZE procedure could meet the demand of minimum required performance limit (MRPL) set by the World Anti-doping Agency (WADA) for the detection of propranolol in urine samples.

Adrenergic beta-Antagonists↗

Solid-phase microextraction of hop volatiles. Potential use for determination and verification of hop varieties.

The composition of hop essential oil is an important tool for evaluation of hop quality. As each hop variety has a typical essential oil pattern (fingerprint), hop oil analyses can be used to distinguish between hop varieties. The headspace solid-phase microextraction (SPME) method as described in this contribution is a simple sample preparation technique and represents an alternative procedure for essential oil fingerprint determination. Different SPME parameters (extraction temperature, extraction time and sample mass) were studied and the results were compared with those obtained by the routine distillation method. It is shown that SPME results can be used for determination and verification of varieties grown in Slovenia by means of principal components analysis.

Chromatography, Liquid↗