Comparison of the dynamics of bile emptying by quantitative hepatobiliary scintigraphy before and after cholecystectomy in patients with uncomplicated gallstone disease.

PURPOSE: Quantitative hepatobiliary scintigraphy, a noninvasive method frequently used to diagnose several biliary tract disorders, shows abnormalities in bile secretion and outflow. It is well known that there are wide variations in the normal pattern of bile emptying, but the effect of cholecystectomy on the bile flow has not yet been investigated. The goal of the current study was to examine the dynamics and normal variations of bile flow by quantitative hepatobiliary scintigraphy before and after cholecystectomy in a group of patients with uncomplicated gallstone disease. METHODS: Twenty patients were evaluated before and after cholecystectomy through cholecystokinin octapeptide-augmented quantitative hepatobiliary scintigraphy, and quantitative parameters of bile emptying (Tmax: time to peak activity, T1/2: half-emptying time before and after cholecystokinin octapeptide and duodenum appearance time) were determined and then compared. RESULTS: Before operation, the bile outflow displayed wide variations, with a moderately delayed common bile duct emptying time in some patients. After cholecystectomy, the T1/2 of the common bile duct decreased significantly when compared with the preoperative status, with only minor patient-to-patient variation, indicating uniformly faster bile emptying (common bile duct T1/2 before and after operation: 30.5 +/- 14.8 and 18.8 +/- 2.6 min, respectively). Cholecystokinin octapeptide administration caused rapid bile outflow from the common bile duct, with a significant decrease in the T1/2 parameters before and after cholecystectomy. CONCLUSIONS: In patients with their gallbladders in situ, the bile emptying rate showed wide variations and may be moderately slow without distal common bile duct obstruction. After cholecystectomy, the rate of bile emptying accelerated and showed only minor variations, thereby increasing the sensitivity of quantitative hepatobiliary scintigraphy for showing partial biliary obstruction.

Adult↗

The use of hepatocyte extraction fraction to evaluate neonatal cholestasis.

PURPOSE: Hepatobiliary scintigraphy is used routinely to evaluate infants with neonatal cholestasis. Hepatobiliary scintigraphy determines biliary patency by detecting radioactivity in the bowel on imaging, in duodenal and gastric aspirates, or all of these. During hepatobiliary scintigraphy, the hepatocyte extraction fraction (HEF) is calculated by deconvolution analysis. Normal values of HEF are more than 90%. It is believed that HEF may predict hepatic dysfunction, because, during hepatobiliary scintigraphy, the radiopharmaceutical used in this test is extracted by the hepatocytes from the blood stream. Therefore, a low value of HEF is seen with more severe hepatocellular disease. The goal of this study was to determine whether HEF has any correlation with synthetic liver function, whether HEF can differentiate obstructive from nonobstructive lesions that cause neonatal cholestasis, and whether HEF can predict the outcome of the different causes of neonatal cholestasis. METHODS: A retrospective analysis of 68 hepatobiliary scintigraphy results was done in patients with neonatal cholestasis for a period covering 6 years. RESULTS: The HEF was available in 67 of these 68 patients, with a median value of 25% (range, 3.3% to 100%). The results of synthetic liver function tests (i.e., albumin and prothrombin time) were normal in all infants with neonatal cholestasis. No significant correlation was detected between HEF and the serum levels of total and direct bilirubin, albumin, alkaline phosphatase, and prothrombin time by exploratory data analysis (R = 0.08; small, P > 0.2). The HEF values in different causes of neonatal cholestasis were compared: extrahepatic biliary atresia, neonatal hepatitis, and a miscellaneous category consisting of alpha1-antitrypsin deficiency, ischemic hepatitis, paucity of bile ducts, and others. The outcomes of these diseases were assessed as resolution, continuing disease, transplantation, or death, but no predictive correlation was found with HEF. CONCLUSIONS: A single determination of HEF is of no value in assessing synthetic liver function (as assessed by albumin and prothrombin time), specific diagnoses, and outcomes in patients with neonatal cholestasis. Therefore, a low isolated value of HEF should not be considered suggestive of poor prognosis and outcome in these patients.

Biliary Tract↗

An unusual white blood cell scan in a child with inflammatory bowel disease: a case report.

Technetium-99m-labeled leukocyte (WBC) imaging is a valuable screening method for inflammatory bowel disease, especially in children, because of its high rate of sensitivity, low cost, and ease of preparation. A 14-year-old girl is described who had juvenile arthritis and iritis complicated by inflammatory bowel disease. She was examined for recurrent abdominal pain. A Tc-99m stannous colloid WBC scan was performed, and tracer accumulation was seen in the small bowel in the region of the distal ileum on the initial 1-hour image. Delayed imaging at 3 hours also revealed tracer accumulation in the cecum and ascending colon, which was not seen on the early image. A biopsy of the colon during endoscopy showed no evidence of active inflammation in the colon. The small bowel was not seen. Computed tomography revealed changes suggestive of inflammatory bowel disease in the distal ileum. The appearance on the WBC study was most likely a result of inflammatory bowel disease involving the distal ileum, with transit of luminal activity into the large bowel.

Adolescent↗

Radionuclide imaging in patients with amputations of the lower leg: typical imaging patterns in five cases.

Amputation of the lower leg is not uncommon in elderly patients with chronic infections or vascular problems of the leg and foot, and most often it is performed below the knee or on the distal part of the lower leg (i.e., Syme's amputation). After operation, healing disorders with or without infection can occur, and usually structural imaging methods are performed for diagnosis. Radionuclide imaging using a combination of bone scans and infection scintigraphy can help to identify bone and soft tissue infection. Interpreting radionuclide scans is difficult, because imaging findings after amputation may depend not only on the level of resection and the disease investigated but also on the time that has elapsed since surgery. Typical imaging patterns of bone or infection scintigraphy of five patients are described

Adult↗

A new method for calculating the distribution of radioactivity in man measured with a whole-body counter.

A whole-body counter with a scanning bed and two opposite (antero-posterior) probes was used to obtain profiles of count rates of radioactivity held in the whole body. The distribution of the activity in the patient was calculated by solving an overdetermined system (more equations than unknowns) of linear equations with the Chebyshev method, the least-squares method, and an iterative method. The iterative method gave the best results, especially in the case of distributions with peaks of radioactivity. Some in-vivo applications of the method are presented.

Diphosphonates↗

Placental transfer of radiopharmaceuticals and dosimetry in pregnancy.

The calculation of radiation dose estimates to the fetus is often important in nuclear medicine. To obtain the best estimates of radiation dose to the fetus, the best biological and physical models should be employed. In this paper the most recent data available on the placental crossover of many radiopharmaceuticals are presented. This information was used with standard kinetic models describing the maternal distribution and retention and with the best available physical models to obtain fetal dose estimates for these radiopharmaceuticals at all stages of pregnancy (presented in a separate paper). The literature yielded information on placental crossover of 15 radiopharmaceuticals, from animal or human data. From these data, radiation dose estimates were developed in early pregnancy and at 3, 6, and 9 mo gestation for these radiopharmaceuticals, as well as for many others used in nuclear medicine (the latter considering only maternal organ contributions to fetal dose).

Adult↗

Radionuclide measurement of differential glomerular filtration rate.

The authors sought to determine whether radionuclides could provide a reasonable estimate of differential renal function in five normal dogs and six dogs with unilateral segmental renal infarction. Glomerular filtration rate (GFR) of each kidney was measured by the standard technique using constant infusions of 99mTc-DTPA, iothalamate, and creatinine following ureteral catheterization. These results were correlated with total GFR estimated by bolus injection of 99mTc-DTPA and analysis of the plasma 99mTc-DTPA disappearance curve obtained by blood sampling. Differential GFR was then calculated by multiplying the total GFR from double exponential analysis of this curve (DTPA2) by each of three measures of differential function. These include the percent differential uptake of 99mTc-DTPA and 99mTc-DMSA in the posterior projection as well as the geometric mean of 99mTc-DMSA uptake. There were good correlations between differential GFR calculated from iothalamate clearances obtained at ureteral catheterization and all noninvasive methods involving radionuclides and DTPA2 (r = 0.85 - 0.99). Single exponential analysis of the 99mTc-DTPA plasma disappearance curve was less satisfactory. The authors suggest that measurement of total and differential GFR calculated from plasma clearance of 99mTc-DTPA and external counting may be a useful method with potential clinical applications.