PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biocompatibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Chemoenzymatic synthesis of sugar-containing biocompatible hydrogels: crosslinked poly(beta-methylglucoside acrylate) and poly(beta-methylglucoside methacrylate).

Sugar-containing biocompatible hydrogels were synthesized chemoenzymatically by the following two steps: 1. lipase-catalyzed esterification of beta-methylglucoside with acrylic acid/methacrylic acid/vinyl acrylate/vinyl methacrylate in solvent as well as solvent-free process for the formation of sugar-containing monomers; and 2. polymerization process by free-radical polymerization with and without a crosslinker, ethylene glycol dimethacrylate (EGDMA). The solvent-free process resulted in an initial reaction rate approximately 1.5-2 times faster than that of the solvent process along with a complete consumption of beta-methylglucoside during the alcoholysis. The presence of pendant vinyl groups in beta-methylglucoside acrylate (MGAA) and beta-methylglucoside methacrylate (MGMAA) was confirmed by (1)H/(13)C NMR analysis, whereas the successful polymerization with the consumption of the vinyl groups was confirmed by Fourier transform infrared spectroscopy and (13)C NMR spectra. The surfaces of both poly(MGAA) and poly(MGMAA) were analyzed using scanning electron microscopy. The increased contents of EGDMA resulted in a higher tensile strength as well as a reduced swelling ratio of poly(MGAA) and poly(MGMAA). The swelling exponents were within the range of 0.53 and 0.98. In vitro cytotoxicity tests by MTT assay exhibited >90% cell viability in the poly(MGAA) and poly(MGMAA) without EGDMA, whereas a significantly decreased cell viability was observed for those with EGDMA.

Acrylates↗

Development of new injectable bulking agents: biocompatibility of radiopaque polymeric microspheres studied in a mouse model.

Radiopaque polymeric microspheres have a potential as new bulking agents for treatment of stress urinary incontinence (SUI). The advantage over existing bulking agents lies in their X-ray visibility in situ; other polymeric bulking agents (e.g., PTFE or silicone rubbers) are practically radiolucent (i.e., incapable of absorbing X-radiation). Radiopacity is useful in practice because of the high spatial accuracy of X-ray imaging. For instance, X-ray fluoroscopy can be used to assess possible migration of the bulking agent over time or to provide guidance in cases in which a second injection of a bulking agent is necessary (repeated treatment of SUI). Biocompatibility of injected radiopaque microspheres was investigated in vivo by using the mouse as a model. Microspheres were injected subcutaneously (9 animals) or intramuscularly (9 animals), and follow-up was 8 days or 3 months. X-ray fluoroscopy gave clear images of the microspheres as an ensemble, and it was found that no migration occurred during 3 months. Histopathology confirmed that all microspheres stayed close to the site of the injection. The microspheres appeared to be well tolerated; only a few giant cells, manifesting a mild inflammatory reaction, were encountered. At 3 months, capillary blood vessels were observed throughout the microsphere beds, and macrophages and fibroblast cells were seen in between the microspheres. This is encouraging with respect to the intended application, although it must be acknowledged that the data refer merely to a mouse model. Further experiments with larger, more representative models (rabbit and goat) are in progress.

Animals↗

Electrochemical studies on zirconium and its biocompatible alloys Ti-50Zr at.% and Zr-2.5Nb wt.% in simulated physiologic media.

Different electrochemical studies were carried out for Zr and its biocompatible alloys Ti-50Zr at.% and Zr-2.5Nb wt.% in solutions simulating physiologic media, Ringer and PBS (phosphate buffered saline) solutions. The results from rest-potential measurements showed that the three materials are spontaneously passivated in both solutions and that the Ti-50Zr alloy has the greatest tendency for spontaneous oxide formation. Some corrosion parameters (such as the pitting and repassivation potentials) were obtained via cyclic voltammetry in both solutions, revealing that the Ti-50Zr has the best corrosion protection while Zr has the worst. On the other hand, the pre-anodization (up to 8 V vs. SCE) of the alloys in a 0.15 mol/L Na2SO4 solution led to a significant improvement in their protection against pitting corrosion when exposed to the Ringer solution. Elemental analyses by EDX showed that during pitting corrosion, there is no preferential corrosion of any of the alloying elements (Zr, Ti, Nb).

Alloys↗

Biocompatibility and degradation of aliphatic segmented poly(ester amide)s: in vitro and in vivo evaluation.

Aliphatic segmented poly(ester amide)s, comprising a crystallizable amide phase and a flexible amorphous ester phase, were investigated for potential use in biomedical applications. By varying the amide content and the type of crystallizable amide segments, the polymer's thermal and mechanical properties can readily be tuned. Polymers with 25 and 50 mol % of amide content are noncytotoxic and sustain growth of fibroblasts onto polymer films. The in vitro degradation of these polymers was followed in PBS (pH 7.4) at 37 degrees C up to 7 months. The poly(ester amide)s showed the characteristics of bulk degradation with a gradual decrease in molecular weight and almost no mass loss. The in vivo degradation of these polymers, followed by subcutaneous implantation in rats up to 6 weeks, was slow and similar to the in vitro degradation. The tissue response upon implantation was followed over 6 weeks. A mild foreign-body reaction, characterized by the presence of macrophages, and sporadically a lymphocyte, were observed in the first week of implantation. After 6 weeks the implant site is characterized by fibrous encapsulation with no signs of inflammation. The poly(ester amide)s tested are biocompatible, but their in vitro as well as in vivo degradation is very slow.

Amides↗

A long-term in vitro biocompatibility study of a biodegradable polyurethane and its degradation products.

The biological safety of degradation products from degradable biomaterials is very important. In this study a new method is proposed to test the cytotoxicity of these degradation products with the aim to save time, laboratory animals, and research funds. A biodegradable polyurethane (PU) foam was subjected to this test method. The PU had soft segments of DL-lactide/epsilon-caprolactone and hard segments synthesized from butanediol and 1,4-butanediiosocyanate. Copolymer foams without urethane segments, consisting of DL-lactide/epsilon-caprolactone, were tested as well. Accumulated degradation products were collected by degrading the foams in distilled water at 60 degrees C up to 52 weeks. Cell-culture medium was prepared from powder medium with this water. In different tests the cytotoxicity of this medium was established. The first signs of cytotoxicity were observed after 3-5 weeks of degradation. This accounts for both materials and reestablishes the good short-term biocompatibility of these materials. The PU showed more toxicity toward the end stages of degradation in comparison with the copolymer. This is probably related to the accumulation of degradation products of the urethane segments. In the in vivo situation the degradation of the PU and the metabolism and excretion of degradation products may differ. Therefore, long-term in vivo studies will have to establish whether these in vitro results are representative for the in vivo behavior of the degrading PU.

Absorbable Implants↗

Development, implantation, in vivo elution, and retrieval of a biocompatible, sustained release subretinal drug delivery system.

A biocompatible, sustained-release subretinal drug-delivery platform was developed to overcome the therapeutic accessibility limitations of current retinal disease treatments. The prototype implants were fabricated by coating nitinol, poly(methyl methacrylate) or chromic gut core filaments, with a drug-eluting polymer matrix. The polymer coatings are manufactured and coated by SurModics. The coating is a mixture of poly(butyl methacrylate) and poly(ethylene-co-vinyl acetate). The drug is either triamcinolone acetonide or sirolimus. The rods were successfully implanted into the subretinal space of 20/24 rabbits. Four rabbits were lost to early surgery from a dysfunctional infusion line and hemorrhage. No serious complications were observed during the 4-week follow-up period. Slight conjunctival redness was reported in all rabbits by 1-day follow-up, but the redness had subsided by the following week. Intraocular lens touch occurred in six rabbits during the implantations; of these, four had a lensectomy at the time of surgery, and the remaining two developed cataract. Corneal edema developed in three rabbits by 1-week follow-up, but subsided within 2 weeks. Initial observations of the implantation and elution characteristics revealed that the implants are well tolerated by the retinal tissue and that the implant can elute triamcinolone acetonide for a period of at least 4 weeks without eliciting an inflammatory response or complications. There were adverse clinical indications with the sirolimus-loaded implants at the delivered dose. Device retrieval required an uncomplicated surgical procedure, and revealed no associated or adherent tissue. Implant drug content analysis and opacity changes to the polymer matrix coating following retrieval demonstrated the sustained elution of the drug.

Animals↗

Influence of plaque biofilm removal on reestablishment of the biocompatibility of contaminated titanium surfaces.

The aim of the present study was to evaluate the influence of plaque biofilm removal on the mitochondrial activity of human SaOs-2 osteoblasts grown on titanium surfaces. Volunteers wore acrylic splints with structured titanium discs for 72 h to build up plaque biofilms (n = 30). Specimens were randomly instrumented using either (1) an ultrasonic system at two power settings (EMS1, EMS2) + chlorhexidine (CHX), or (2) plastic curettes + CHX. Untreated (NC, n = 10) and sterile (C, n = 10) titanium discs served as controls. Specimens were incubated with SaOs-2 cells for 6 days. Treatment time (T), residual plaque biofilm (RPB)/clean implant surface areas (%), mitochondrial cell activity (MA) (counts/second), and cell morphology (SEM) were assessed. Statistical analysis revealed the following mean scores (+/-SD): RPB areas: P (58.5 +/- 4.9) > EMS1 (38.4 +/- 4.1) > EMS2 (28.3 +/- 2.0); T: PC (292 +/- 30) = EMS1 (244 +/- 24) > EMS2 (199 +/- 25); MA: C (1.544.661 +/- 203.442) > PC (597.559 +/- 566.984) = EMS2 (389.875 +/- 409.300) = EMS1 (356.653 +/- 293.863; n.s.) > NC (138.676 +/- 86.666). In NC and PC groups, cells were predominantly rounded in shape. However, in the EMS groups, some cells had started to spread, showing complete cytoplasmatic extensions of the cell body on the titanium surface. A monolayer of flattened cells was generally observed in the C group. Within the limits of the present study, it was concluded that MA seemed to be impaired by the presence of RPB areas. However, its removal alone might not be the crucial step in the reestablishment of the biocompatibility of titanium surfaces.

Adult↗

Biocompatibility of elastin-like polymer poly(VPAVG) microparticles: in vitro and in vivo studies.

Poly(L-valine-L-proline-L-alanine-L-valine-L-glycine) (VPAVG) is a new kind of proteinaceous polymer belonging to the Elastin-like family. These polymers are based on the recurrence of certain short peptide monomers that are considered as "building blocks" in the natural elastin. This smart thermoresponsive polymer has the ability to self-associate at physiological temperature to form aggregates with about 60% in water. This ability can be harnessed to prepare microparticles loaded with an active substance. The aim of this report is to evaluate, from the results of the experiment conducted, the biocompatibility of microparticles prepared from poly(VPAVG). We have studied the cytotoxic effects of microparticles, edema formation after subcutaneous injection (1 and 2.5 mg) in rats (n = 6), and also intraocular tolerance after the intravitreal injection of 2.5 mg of poly(VPAVG) microparticles into pigmented rabbits (n = 12). The polymer did not induce any cytotoxicity or nonspecific depression of cellular respiration on macrophages under the range of polymer concentrations investigated in this study (20, 30, 40, and 60 mg/mL). We observed no inflammatory response to microparticles after subcutaneous injection in the hind-paw of rats, with no significant differences between the control group (PBS) and experimental groups. Anterior and posterior segment signs were evaluated after intraocular injection of poly(VPAVG) microparticles. Only a few eyes (2/11) of the experimental group presented inflammation signs at day 28 postinjection. Nevertheless, 45% (5/11) of the eyes receiving microparticles showed tractional retinal detachment. The results observed in this work suggested certain fibroblastic activity induced by poly(VPAVG) microparticles after their intraocular injection.

Alanine↗

Crystallochemistry, textural properties, and in vitro biocompatibility of different silicon-doped calcium phosphates.

Three silicon-doped calcium phosphates (Si-CaPs) were synthesized by heating precipitated silicon-doped apatite via different thermal treatments. Temperatures of 700 degrees C, 900 degrees C, and 1100 degrees C led to an apatite-glass biphasic material, nanocrystalline Si-doped apatite (SiHA), and Si-doped apatite-alpha tricalcium phosphate biphasic material, respectively. Structure, microstructure, textural properties, and chemical differences were determined for the three bioceramics. Biocompatibility tests were carried out by seeding osteblast-like cells onto the three substrates. Si-CaP treated at 700 degrees C and 900 degrees C led to Ca decrease in the culture media, partially impeding the cell proliferation over them. However, the proliferation capability is restored when additional culture medium is added. Finally, cytotoxicity results indicated that cell damage is much lower in osteblast-like cells seeded onto SiHA and SiHA-alpha tricalcium phosphate samples than in plastic culture control.

Biocompatible Materials↗

Biocompatibility evaluation of surface-treated AISI 316L austenitic stainless steel in human cell cultures.

The effects of AISI 316L austenitic stainless steel, tested in untreated state or subjected to glow-discharge nitriding (at 10 or 20 hPa) and nitriding + post-oxidizing treatments, on human umbilical vein endothelial cells (HUVEC) and on peripheral blood mononuclear cells (PBMC) were evaluated. All the treated samples showed a better corrosion resistance in PBS and higher surface hardness in comparison with the untreated alloy. In HUVEC put in contact for 72 h with the sample types, proliferation and apoptosis decreased and increased, respectively, in the presence of the nitrided + post-oxidized samples, while only slight differences in cytokine (TNF-alpha, IL-6, and TGF-beta1) release were registered. Intercellular adhesion molecule-1 (ICAM-1) increased in HUVEC incubated with all the treated samples, while vascular cell adhesion molecule-1 (VCAM-1) and E-selectin increased in the presence of all the sample types. PBMC incubated for 48 h with the samples showed a decrease in proliferation and an increase in apoptosis in the presence of the untreated samples and the nitrided + post-oxidized ones. All the sample types induced a remarkable increase in TNF-alpha and IL-6 release in PBMC culture medium, while only the untreated sample and the nitrided at 10 hPa induced an increase in ICAM-1 expression. In HUVEC cocultured with PBMC, previously put in contact with the treated AISI 316L samples, increased levels of ICAM-1 were detected. In HUVEC coincubated with the culture medium of PBMC, previously put in contact with the samples under study, a noteworthy increase in ICAM-1, VCAM-1, and E-selectin levels was always registered, with the exception of VCAM-1, which was not affected by the untreated sample. In conclusion, even if the treated samples do not show a marked increase in biocompatibility in comparison with the untreated alloy, their higher corrosion resistance may suggest a better performance as the contact with physiological environment becomes longer.

Biocompatible Materials↗

Zeta-potentials of alginate-PLL capsules: a predictive measure for biocompatibility?

Alginate-poly-L-lysine (PLL) microencapsulation of cells is a promising approach to prevent rejection in the absence of immunosuppression. Clinical application, however, is hampered by insufficient insight in factors influencing biocompatibility of the capsules. By now, it has been accepted that not only the chemical composition of the materials applied but also other factors contribute to bioincompatibility. The zeta-potential serves as a measure for the electrical charge of the surface and has been shown to be a predictive value for the interfacial reactions between the biomaterial and the surrounding tissue in other applications. In the present study, we have assessed the streaming potential of alginate-PLL capsules composed of either low-, intermediate-, or high-guluronic (G) alginate to calculate the zeta-potential. The zeta-potentials of the capsules were compared to the biological response against the capsules at 4 weeks after implantation in the rat. We show that high-G and low-G alginates provoke a more severe response in the rat than capsules prepared of intermediate-G alginate. This correlates with a higher zeta-potential of the high-G and low-G alginates and by a change in zeta-potential at lower pH. These lower pH-levels are common directly after implantation as the consequence of a host-response associated with mandatory surgery. Our results suggest that we should not only consider the capsule properties under physiological circumstances to explain bioincompatibility but also the capsule features during common pathophysiological situations.

Alginates↗

Composition and in vitro biocompatibility of corroding tungsten coils.

The purpose of the article is to evaluate composition and biocompatibility of corroding mechanically detachable spirals (MDS, Balt Extrusion, Montmorency, France). Analysis of the material composition of corroding MDS coils was assessed by inductively coupled plasma atomic emission spectroscopy, inductively coupled plasma mass spectroscopy, and wavelength-dispersive x-ray spectrometry. Toxicity assays were performed with human venous endothelial cells, venous smooth muscle cells and fibroblasts. The analyses of the MDS coils demonstrated a tungsten content of the dissolving MDS spirals of > 99.9 mas%. In vitro, human endothelial, vascular smooth muscle cells and fibroblasts were not adversely affected by markedly elevated tungsten concentrations (60,500 microg/l) after 12 days in the culture medium. The examined cells showed an extensive vital growth on the coil surface. Corrosion of tungsten coils leads to markedly elevated tungsten levels in the culture medium. However, growth and vitality of endothelial cells, fibroblasts, and vascular smooth muscle cells are not adversely affected by elevated tungsten concentrations.

Biocompatible Materials↗

In vitro and in vivo biocompatibility evaluation of a polyalkylimide hydrogel for soft tissue augmentation.

Injectable fillers are commonly used in Plastic and Reconstructive Surgery to correct serious and slight aesthetic defects due to their low invasiveness and an easy implant technique procedure. Synthetic hydrogels are proposed as filler materials for their similarity with soft tissue and to avoid many disadvantages of naturally derived materials such as short persistence, allergenicity, and immunogenicity. Our studies are focused on the biocompatibility evaluation of a polyacrylic hydrogel containing alkylimide-amide groups and pyrogen free water (96%) (Bio-Alcamid by means of the in vitro cytotoxicity and mutagenicity assays and the in vivo skin irritation, sensitization test, and subcutaneous implant. All tests conducted on Bio-Alcamid showed no toxicity. It is a substance easy to inject and remove; it does not migrate, and its safety allows it to be a suitable filler for the correction of slight and also very serious aesthetic defects.

3T3 Cells↗

New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility.

Various oxidation treatments were applied to nearly equiatomic NiTi alloys so as to form a Ni-free protective oxide on the surface. Sample surfaces were analyzed by X-ray Photoelectron Spectroscopy, and NiTi transformation temperatures were determined by differential scanning calorimetry (DSC) before and after the surface treatment. An ion release experiment was carried out up to one month of immersion in SBF for both oxidized and untreated surfaces. The results show that oxidation treatment in a low-oxygen pressure atmosphere leads to a high surface Ti/Ni ratio, a very low Ni surface concentration and a thick oxide layer. This oxidation treatment does not significantly affect the shape memory properties of the alloy. Moreover, the oxide formed significantly decreases Ni release into exterior medium comparing with untreated surfaces. As a consequence, this new oxidation treatment could be of great interest for biomedical applications, as it could minimize sensitization and allergies and improve biocompatibility and corrosion resistance of NiTi shape memory alloys.

Alloys↗

The biocompatibility of silk fibroin films containing sulfonated silk fibroin.

Sulfonation reaction may be an effective method for preparation of heparin-like materials. However, no sulfonated polymer based on protein backbone was used for improving the blood compatibility of biomaterials. In this study, the biocompatibility of new kind of composite materials films obtained by blending silk fibroin (SF) with sulfonated silk fibroin (SSF) was evaluated. The anticoagulant activity was characterized with prothrombin time (PT), activated partial thromboplastin time (APTT), and thrombin time (TT), which all increased remarkably, the clot times exceeded the measurement limit of clot detection instrument. Its platelet adhesion was also investigated as another parameter of blood compatibility. The cell compatibility of composite films was evaluated through cell morphologies on the films and cell viability by methyl thiazolyl tetrazolium (MTT) assay. Tensile strength and elongation at break of the composite films reached to 44.6 MPa and 50.3%, respectively. All these results indicated that SF/SSF composite film was a potential material for blood-contact materials and tissue engineering matrix.

Animals↗

Manipulation of beclomethasone-hydrofluoroalkane interactions using biocompatible macromolecules.

The aim of this work was to physically stabilise beclomethasone dipropionate (BDP) microparticles within a hydrofluoroalkane (HFA) propellant using biocompatible polymers in order to allow the efficient delivery of the steroid to the airways from a pressurised metered dose inhaler (pMDI). BDP microparticles were coated with a number of different "amphiphilic" macromolecular excipients by spray-drying an aqueous BDP suspension in which the excipients were dissolved. The physical stability of the coated BDP microparticles was assessed both indirectly using a twin-stage impinger (TSI) and directly using "in-situ" laser diffraction particle size analysis in a range of nonpolar solvents. The solubility of the formulation excipients within a number of the nonpolar vehicles was determined using an internally manufactured filtration rig and the influence of zeta potential within the microparticle suspensions measured in a series surrogate nonpolar systems. The size of the pure BDP microparticles increased significantly (p < 0.05, ANOVA) from 3.13 +/- 0.15 microm to 9.86 +/- 0.50 microm upon suspension within a nonpolar HFA solvent. However, the addition of poly(vinyl alcohol) (PVA) and poly(vinyl pyrrolidone) (PVP) to the BDP microparticles dramatically reduce this aggregation leading to the production of physically stable suspensions with excellent aerosolisation properties (Stage 2 deposition >40% in the twin-stage impinger). It is postulated that the enhanced physical stability observed when PVA and PVP are coated onto BDP microparticles is partially as a result of steric stabilisation in HFA solvents. However, the large zeta potential associated with the nonpolar microparticle suspensions suggest that charge stabilisation may also influence the physical stability within these systems.

Aerosol Propellants↗

Enhanced biocompatibility in biostable poly(carbonate)urethane.

In this work, we synthesized two MDI-based polyurethanes, including a poly(ether)urethane (PEU) and a poly(carbonate)urethane (PCU), by using different soft segments, poly(tetramethylene oxide) and poly(hexyl, ethyl)carbonate diol (M approximately 2,000). We demonstrated that, in addition to the enhanced biostability of PCU over PEU, the biological performances of PCU in vitro were also improved in general. These included, better cellular attachment and proliferation, less platelet activation, as well as reduced monocyte activation. The unusual wide-ranging enhancement in biocompatibility for PCU was believed to be related to the larger micro-phase separation in PCU (approximately 25 nm) that caused distinct protein adsorption on the surface. The total number of adherent monocytes (nonactivated and activated) on the bare sample surfaces, albumin pre-adsorbed sample surfaces, and fibrinogen pre-adsorbed sample surfaces.

Adsorption↗

Hydrogel networks of poly(ethylene oxide) star-molecules supported by expanded polytetrafluoroethylene membranes: characterization, biocompatibility evaluation and glucose diffusion characteristics.

The present work discusses the grafting by electron beam irradiation of poly(ethylene oxide) (PEO) star-shaped polymers onto porous expanded polytetrafluoroethylene (EXPTFE) surfaces. The resulting materials are intended to combine the good biocompatible properties of PEO with the outstanding mechanical properties of PTFE. The star-shaped PEOs were synthesized via anionic polymerization. 3 Mev electron beam irradiation was applied to graft these PEO stars onto porous EXPTFE surfaces. The hydrophobic EXPTFE surface had to be pre-modified with N-vinylpyrrolidone. ESCA was used to quantify the amount of grafted star-shaped PEO. Unmodified EXPTFE surfaces are well known, when implanted in a body, to be rapidly covered by a layer of cells and fibrin. The EXPTFE coated with PEO were implanted in the peritoneal cavity of rats (or under the back skin). This implantation did not induce any inflammation reactions and SEM analysis had attested the absence of adsorbed cells and fibrin. The glucose diffusion properties of these membranes were studied by a lag time analysis method and compared to those of pure PEO hydrogels. As expected, glucose diffuses through the hydrogel coated membrane and diffusion is not affected by the presence of the EXPTFE membrane.

Animals↗