PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Enhancer”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Enhancement of visual responses in monkey striate cortex and frontal eye fields.

1. We have studied the visual enhancement effect in two areas of the cerebral cortex of monkeys. The response of the cells to a visual stimulus was determined both when the monkey used the visual stimulus as the target for a saccadic eye movement and when he did not. 2. In striate cortex cells with nonoriented, simple, complex, and hypercomplex receptive-field types were studied. Clear enhancement of the response to the appropriate visual stimulus was seldom seen when the monkey used the stimulus as a target for a saccade. In addition, any enhancement effect seen was nonselective; it occurred whether the monkey made a saccade to the receptive-field stimulus or some other stimulus at a point distant from the receptive field. The enhancement also occurred whether the monkey made a saccade to the stimulus or just released the bar when the stimulus dimmed. 3. This nonselective enhancement in striate cortex is in striking contrast to the selective enhancement of the visual response seen in the superior colliculus. The different characteristics of the enhancement in striate cortex and the observation of enhancement in the colliculus following ablation of striate cortex suggest that this cortical area is an unlikely source of the collicular enhancement. 4. These observations reinforce the distinction between striate cortex and superior colliculus. Striate cortex is an excellent analyzer of stimulus characteristics but a poor evaluator of stimulus significance. The superior colliculus is an excellent evaluator but a poor analyzer. 5. The area of frontal eye fields in which cells have clear visual responses has been better localized. Enhancement of the visual response of these cells also occurs and, at least for some cells, the response enhancement is selective. The response enhancement, like the visual properties of these frontal eye field cells, appears to be more closely related to the properties of superior colliculus cells than to striate cortex cells.

Animals↗

Silver enhancement of gold antibody probes in pre-embedding electron microscopic immunocytochemistry.

In pre-embedding EM immunocytochemistry with gold probes, the gold must be small enough to penetrate through cell membranes treated with mild detergents. Antibodies labeled with small gold probes (1-1.4 nm) are too small to be resolved in thin sections but can be seen if they are silver-enhanced after the gold has bound to the antigens in the cells. We investigated several aspects of gum arabic-silver lactate-hydroquinone enhancement solution (Danscher solution) by examining gold-conjugated antibodies embedded in agar, sectioned on a vibrotome, and enhanced with different solutions. The rate of silver enhancement was optimized in 50% gum arabic and 200 mM HEPES buffer, pH 5.8. We also examined chemicals used as developers and found that N-propyl gallate (NPG) gave a more uniform development than the routinely used hydroquinone (HQ). The diameter of the silver-enhanced particles after incubation in osmium tetratoxide (OSO4) decreased somewhat with longer incubation time and higher percentages, but the density (number per unit area) of silver-enhanced particles was little changed. The loss of silver-enhanced particle diameter was reduced by lowering the concentration of OSO4 to 0.1%. Comparison of commercial small gold probes showed that NPG enhancement of Nanogold gave more uniform particle size and a better correlation between enhancement time and particle density. When this procedure was applied to cell cultures with monoclonal antibodies, the silver-enhanced particles were similar to those in the agar sections. When free-floating tissue sections were used, longer silver enhancement times were needed to obtain similarly sized particles. This new NPG-silver-enhancement procedure offers a reliable and easy method to localize proteins in cultured cells and tissue sections by pre-embedding electron microscopic immunocytochemistry.

Animals↗

Effectiveness and toxicity screening of various absorption enhancers using Caco-2 cell monolayers.

We studied the enhancing and toxic effects of five different absorption enhancers on the transport of FITC-dextran with an average molecular weight of 4000 (FD-4) across Caco-2 cell monolayers, and their enhancing effects were also compared with those in rat intestine. The enhancing and cytotoxic properties of these enhancers were characterized using the following tests: measurement of the permeability coefficients of FD-4 and the transepithelial electrical resistance (TEER) in Caco-2, the release of cytosolic lactate dehydrogenase (LDH) and intracellular mitochondrial dehydrogenase (MDH) activity. All the absorption enhancers increased the permeability of FD-4 across Caco-2 cell monolayers and a good relationship was observed between the enhancement and their toxic effects. However, EDTA and Na-Cap were effective for improving the transport of FD-4 across Caco-2 cells without serious cytotoxicity. At concentrations with low cytotoxicity, various absorption enhancers exihibited reversible effects on the TEER values in Caco-2 cell monolayers, except for 50 mM sodium salicylate (Na-Sal). Moreover, we obtained a good correlation between the enhancement of these enhancers in Caco-2 cell monolayers and in rat large intestine. This finding indicated that the effectiveness of absorption enhancers in the Caco-2 monolayer system was similar to an in vivo rat system. Therefore, the screening system using Caco-2 cell monolayers is useful for examining the effectiveness and toxicity of absorption enhancers.

Animals↗

Hepatic metastases: perilesional enhancement on dynamic MRI.

OBJECTIVE: Our purpose was to determine whether the perilesional parenchymal enhancement of hepatic metastases could be correlated with tumoral enhancement on arterial phase images or tumor size on dynamic MRI. MATERIALS AND METHODS: One hundred thirty-four lesions of hepatic metastases in 44 patients were subjected to a retrospective analysis of the dynamic MR images obtained with 3D spoiled gradient-echo sequences. The thickness of the enhancing rim on arterial phase images was regarded as a summation of the enhancing component of tumor periphery and perilesional enhancement, which were estimated by the tumor size on precontrast T1-weighted images. The presence of wedge-shaped perilesional enhancement was also correlated with the lesion size. RESULTS: Except for 17 diffusely enhanced lesions, lesion size was comparable between the lesions with (n = 87; 26 +/- 19 [SD] mm) and without rim enhancement (n = 30; 27 +/- 23 mm) on the arterial phase dynamic MR images (p > 0.05). The degree of peripheral tumoral enhancement showed an inverse correlation (r = -0.389) with the thickness of the circumferential perilesional enhancement (p < 0.001). The mean size of the lesions with wedge-shaped perilesional enhancement (n = 44; 33 +/- 20 mm) was larger than that of the other lesions (n = 90; 25 +/- 19 mm) (p = 0.016). CONCLUSION: The degree of circumferential perilesional enhancement of hepatic metastases on arterial phase dynamic MR images would be independent of the lesion size but inversely correlated with the degree of peripheral tumoral vascularity. An understanding of these features may help tumor characterization and should prompt hypotheses and studies of microvascular phenomena in tumoral and epitumoral environments.

Adult↗

Gadopentetate dimeglumine-enhanced chemical-shift MR imaging of the breast.

Standard T1-weighted MR images enhanced with gadopentetate dimeglumine show relatively minimal enhancement of breast lesions due to the high background signal from fat in the breast. Strongly enhancing lesions may become isointense relative to the fat signal and become invisible or indistinct after contrast administration. Fat-suppressed chemical-shift imaging (CSI) combined with administration of gadopentetate dimeglumine improves lesion detection and characterization in other areas of the body where a strong lipid signal is present. We evaluated this technique in the breast. Twenty patients with mammographic lesions were studied with standard unenhanced T1- and T2-weighted images and enhanced T1-weighted images, as well as with CSI before and after administration of gadopentetate dimeglumine. The series were ranked independently for border and matrix characteristics. The border was assessed for a smooth, irregular, or spiculated margin. The matrix or internal substance was evaluated for visibility and type of enhancement, homogeneous or inhomogeneous. The enhanced CSI images were superior to all other images in the depiction of border and matrix characteristics. Of 20 patients, a corresponding mass was detected on MR in 14. In two of the 14 patients, the lesion was seen only in the enhanced CSI images. Chemical-shift artifacts on enhanced T1-weighted images obscured border detail in several cases. Enhanced CSI improves visualization of breast lesions as compared with conventional MR imaging with or without enhancement. The enhanced CSI technique produces differential enhancement between glandular tissue and lesions while suppressing the signal from fat. This improves the visualization of border and matrix characteristics and depicts lesions that otherwise might be obscured.

Breast Neoplasms↗

Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts.

OBJECTIVE: The value of echo-enhanced color and power Doppler sonography in the evaluation of transjugular intrahepatic portosystemic shunts (TIPS) was assessed and compared with that of unenhanced Doppler sonography and portal angiography. SUBJECTS AND METHODS: In a prospective randomized trial, 31 shunts in 30 patients underwent unenhanced conventional color and power Doppler sonography and portal venography including pressure measurements. The patients were allocated to either echo-enhanced conventional color Doppler sonography or echo-enhanced power Doppler sonography. For echo enhancement, a galactose-based suspension was administered IV. Shunt stenoses, if present, were quantified by percentage of stenosis and correlated with angiography, which was the gold standard. The diagnostic confidence of unenhanced and echo-enhanced Doppler sonography was assessed using a visual analog scale. RESULTS: In the diagnosis of shunt occlusion, echo-enhanced Doppler sonography yielded a sensitivity and a specificity of 100% and 100%, respectively, compared with 100% and 89%, respectively, for unenhanced Doppler sonography. Our evaluation of hemodynamically significant stenoses (portosystemic gradient > or = 15 mm Hg) found echo-enhanced Doppler sonography to be superior to unenhanced Doppler sonography (sensitivity and specificity of 82% and 83%, respectively, compared with 64% and 80%, respectively). In the detection of a shunt stenosis based on morphologic criteria only, echo-enhanced Doppler sonography yielded a sensitivity and a specificity of 78% and 100%, respectively, compared with 47% and 50%, respectively, for unenhanced Doppler sonography. Power Doppler imaging did not improve diagnostic accuracy but did increase diagnostic confidence for unenhanced Doppler sonography compared with conventional color Doppler sonography. The diagnostic confidence for sonographic evaluation of TIPS was significantly (p < .001) increased and the variability of hemodynamic measurements was markedly decreased with echo-enhanced sonography. CONCLUSION: Echo-enhanced Doppler sonography provides images of TIPS like those of angiography and allows morphologic assessment of the shunts, complementary to the essential pulsed Doppler waveform analysis that would be performed in a more guided manner. Also, echo-enhanced Doppler sonography significantly increases the sensitivity and specificity in the diagnosis of shunt dysfunction. The high diagnostic confidence and the diminished variability of spectral Doppler measurements may improve acceptance of sonographic evaluation of TIPS. Echo-enhanced Doppler sonography is safe and effective and may reduce the instances in which TIPS sonographic surveillance is nondiagnostic, in which case angiographic assessment is required.

Adult↗

Renal MR angiography at 1.0 T: three-dimensional (3D) phase-contrast techniques versus gadolinium-enhanced 3D fast low-angle shot breath-hold imaging.

OBJECTIVE: The purpose of this study was to evaluate the diagnostic usefulness of three different MR angiographic techniques at 1.0 T. SUBJECTS AND METHODS: In 22 patients with renal artery stenosis confirmed at intraarterial catheter angiography, we also performed unenhanced and gadolinium-enhanced three-dimensional phase-contrast MR angiography and gadolinium-enhanced single breath-hold three-dimensional fast low-angle shot MR angiography. We determined circulation time to optimize signal acquisition in gadolinium-enhanced breath-hold MR angiography after bolus injection of contrast material. RESULTS: Sensitivity, defined as the detection of a hemodynamically significant stenosis (>50% luminal narrowing), was 85% for enhanced phase-contrast MR angiography, 91% for gadolinium-enhanced MR angiography, and 95% for unenhanced phase-contrast MR angiography. The combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography yielded 100% sensitivity for hilar artery stenoses. There were 13 false-positive findings with unenhanced phase-contrast MR angiography, 10 with enhanced phase-contrast MR angiography, and four with gadolinium-enhanced MR angiography (specificity: 38%, 52%, and 79%, respectively). Accessory renal arteries were not seen on unenhanced or enhanced phase-contrast MR angiography (0/8 patients) but were detected with gadolinium-enhanced MR angiography in five of the eight patients. Interobserver agreement (kappa = .62) was best with gadolinium-enhanced MR angiography. The quality of the images was unsatisfactory for adequate evaluation of segmental renal arteries with all three MR angiographic techniques. CONCLUSION: A combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography at 1.0 T proved useful as a screening protocol for renal artery stenosis.

Adult↗

Oxygen-enhanced MR ventilation imaging of the lung: preliminary clinical experience in 25 subjects.

OBJECTIVE: The purpose of this study was to show the feasibility of oxygen-enhanced MR ventilation imaging in a clinical setting with correlation to standard pulmonary function tests, high-resolution CT, and (81m)Kr ventilation scintigraphy. SUBJECTS AND METHODS: Seven healthy volunteers, 10 lung cancer patients, and eight lung cancer patients with pulmonary emphysema were studied. A respiratory synchronized inversion-recovery single-shot turbo-spin-echo sequence (TE, 16; inversion time, 720 msec; interecho spacing, 4 msec) was used for data acquisition. The following paradigm of oxygen inhalation was used: 21% oxygen (room air), 100% oxygen, 21% oxygen. MR imaging data including maximum mean relative enhancement ratio and mean slope of relative enhancement were correlated with forced expiratory volume in 1 sec, diffusing lung capacity, high-resolution CT emphysema score, and mean distribution ratio of (81m)Kr ventilation scintigraphy. RESULTS: Oxygen-enhanced MR ventilation images were obtained in all subjects. Maximum mean relative enhancement ratio and mean slope of relative enhancement of lung cancer patients were significantly decreased compared with those of the healthy volunteers (p < 0.0001, p < 0.0001). The mean slope of relative enhancement in lung cancer patients with pulmonary emphysema was significantly lower than that of lung cancer patients without pulmonary emphysema (p < 0.0001). Maximum mean relative enhancement ratio (r(2) = 0.81) was excellently correlated with diffusing lung capacity. Mean slope of relative enhancement (r(2) = 0.74) was strongly correlated with forced expiratory volume in 1 sec. Maximum mean relative enhancement had good correlation with the high-resolution CT emphysema score (r(2) = 0.38). The maximum mean relative enhancement had a strong correlation with the distribution ratio (r(2) = 0.77). CONCLUSION: Oxygen-enhanced MR ventilation imaging in human subjects showed regional changes in ventilation, thus reflecting regional lung function.

Adult↗

Value of contrast-enhanced sonography for the characterization of focal hepatic lesions in patients with diffuse liver disease: receiver operating characteristic analysis.

OBJECTIVE: Our aim was to assess the diagnostic performance of contrast-enhanced agent detection sonographic imaging to characterize focal hepatic lesions in patients with diffuse liver disease in comparison with baseline sonographic images and to determine whether agent detection imaging can reduce the necessity of further diagnostic workup for lesion characterization. MATERIALS AND METHODS: Contrast-enhanced sonography using 4 g of Levovist at a concentration of 300 mg/mL was performed on 75 focal hepatic lesions in 75 patients with diffuse liver disease. Interval reviews for both baseline without and with contrast-enhanced sonography were performed independently by two radiologists. They were requested to determine the malignity of focal hepatic lesions using a 5-point confidence level and to record the specific diagnoses and the necessity for further imaging for lesion characterization. Radiologists' performances for lesion differentiation using baseline and contrast-enhanced sonography were evaluated using receiver operating characteristic (ROC) analysis. Interobserver agreement was also analyzed. RESULTS: When contrast-enhanced sonography was used, ROC analysis revealed a significant improvement for both reviewers (area under the receiver operating characteristic curve [A(z)] = 0.753 and 0.830 and 0.971 and 0.974 at baseline sonography and contrast-enhanced sonography, respectively; p < 0.002) for differentiating malignant and benign focal liver lesions. Contrast-enhanced sonography also improved specificity from 12% to 91% for reviewer 1 and from 26% to 85% for reviewer 2 compared with baseline sonography. Furthermore, excellent interobserver agreement was achieved for contrast-enhanced sonography (weighted kappa = 0.919), whereas only good agreement was achieved for baseline sonography (weighted kappa = 0.656). A better result for specific diagnosis was obtained by contrast-enhanced sonography (79% and 75%) than by baseline sonography (37% and 48%, p < 0.05). Contrast-enhanced sonography (72% and 63%) outperformed baseline sonography (35% and 28%, p < 0.05) as a confirmatory imaging technique. CONCLUSION: Contrast-enhanced agent detection sonography can be used to characterize focal hepatic lesions in patients with diffuse liver disease reliably and with a higher diagnostic confidence than baseline sonography. Furthermore, contrast-enhanced sonography reduced the need for further diagnostic workups for focal hepatic lesion characterization.

Adult↗

Complement-mediated enhancement of HIV-1 infection in peripheral blood mononuclear cells.

We investigated if complement-mediated enhancement of HIV infection occurs in peripheral blood mononuclear cells (PBMC). In 7 experiments, we evaluated the effect of human complement on HIVIIIB infection in vitro. We measured HIV antigen production on day 4 and found that pre-incubation of HIV with complement led to enhanced production of antigen with a median enhancement of 2.5-fold (range 1.1-6.8). This complement-mediated increase in antigen production was statistically significant (p < 0.02). Complement-mediated enhancement of HIV infection was also tested in CD4 cells enriched from PBMC, and CD4 cells persistently gave higher levels of infection enhancement than PBMC. Thus, CD4 cells appear to be sufficient for complement-mediated enhancement of HIV infection to occur. In addition, we tested if it was possible to detect complement-mediated enhancement of primary HIV isolates in PBMC. We tested 3 isolates and found only a minor effect on antigen production (median enhancement 1.2-fold, range 0.6-1.5). Furthermore, addition of HIV-specific antibodies in combination with complement resulted in enhanced antigen production in 2/3 sera tested. However, the combination of complement and antibodies resulted in only a minor increase in enhancement of HIV infection compared to that obtained with complement alone. Finally, we found evidence of complement-mediated enhancement of HIV infection in resting PBMC. In conclusion, we demonstrated that complement-mediated enhancement of HIV infection does occur in vitro in PBMC.

CD4-Positive T-Lymphocytes↗

Antibody-mediated enhancement of dengue virus infection in mouse macrophage cell lines, Mk1 and Mm1.

Antibody-mediated enhancement of dengue type 2 virus (D2V) replication in murine macrophage cell lines (Mk1 and Mm1) was studied. While both Mk1 and Mm1 supported D2V replication in the absence of enhancing antibodies, virus production was enhanced when both cell lines were inoculated with D2V in the presence of dengue type 1 virus (D1V)-hyperimmune rabbit IgG, D1V-hyperimmune mouse ascitic fluids, or D2V-hyperimmune mouse ascitic fluids at subneutralizing concentrations. The enhancement ratios were greater in Mk1 than in Mm1. Type-specific neutralizing monoclonal anti-D2V antibody also mediated D2V replication enhancement in Mk1 to the same extent as mediated by three other enhancing antibodies described above. In contrast, however, the same monoclonal antibody mediated only a slight and smaller magnitude of D2V replication enhancement in Mm1 than did the other enhancing antibodies. Fluorescent antibody observations revealed that virus replication enhancement in both Mk1 and Mm1 was due primarily to an increase in the numbers of virus-infected cells. D2V infection enhancement in Mk1 by the anti-D2V mouse ascitic fluids at a dilution showing nearly 50% plaque-reduction activity was markedly suppressed by addition of complement to the inocula, whereas that by the monoclonal antibody, which has been identified as mouse IgG1, was not. Phagocytoses of tritiated thymidine-labeled bacteria by Mk1 and Mm1 were also enhanced when the bacteria had been opsonized with antibody. The phagocytosis enhancement ratios were again greater in Mk1 than in Mm1.

Animals↗

Factors influencing the need for enhancement after laser in situ keratomileusis.

PURPOSE: To confirm that enhancements after primary laser in situ keratomileusis (LASIK) are effective in dealing with residual refractive errors, and to determine if any variables prior to or during the primary LASIK procedure predisposed eyes to require subsequent enhancement. METHODS: A retrospective study of eyes undergoing primary LASIK with the VISX S2 or S3 laser and Hansatome microkeratome between January 1, 2000 and January 1, 2002 was done. Of the 393 eyes of 207 patients, 58 eyes (14%) underwent enhancement within a 16-month window of the primary procedure. Statistical comparisons were made between enhanced (n = 37) and non-enhanced (n = 148) patients, and enhanced (n = 48) and non-enhanced (n = 303) eyes, treated for myopia only. RESULTS: In comparing the primary LASIK parameters of enhanced to non-enhanced eyes in myopic patients, no significant difference was found in right vs left eye, season of the primary treatment, preoperative astigmatism, pachymetry, or amount of attempted astigmatism correction. A multivariate logistic regression analysis revealed that male gender, patient age over 45 years, and a history of recent rigid contact lens use within 6 months of primary LASIK were significantly associated with the need for enhancement. CONCLUSION: Enhancements were an effective way of dealing with residual refractive errors after primary LASIK. Age greater than 45 years or a history of recent rigid contact lens use were significantly associated with the need for enhancement in patients with myopia or myopic astigmatism.

Adult↗

Assessment of the therapeutic response of hepatocellular carcinoma treated with transcatheter arterial chemoembolization: comparison of contrast-enhanced sonography and 3-phase computed tomography.

OBJECTIVE: The purpose of this study was to compare contrast-enhanced sonography with 3-phase computed tomography (CT) in assessing the therapeutic response of hepatocellular carcinomas (HCCs) treated with transcatheter arterial chemoembolization (TACE). METHODS: Twenty-nine nodular HCCs treated with TACE were examined with contrast-enhanced sonography, 3-phase helical CT, and conventional angiography. Contrast-enhanced sonographic and CT findings were interpreted separately and prospectively for the presence or absence of contrast enhancement in the treated HCCs. Conventional angiography served as the reference standard. RESULTS: Intratumoral enhancement was seen in 19 HCCs (61%) on contrast-enhanced sonography and 12 HCCs (39%) on CT. Enhancement patterns on sonography were blush in 8 (42%), branching in 2 (11%), nodular in 4 (21%), and stippled in 5 (26%). Of the 19 HCCs with intratumoral enhancement on contrast-enhanced sonography, 13 (68%) showed tumor staining on angiography. Of the 12 HCCs without intratumoral enhancement on sonography, 1 (8%) showed tumor staining on angiography. The sensitivity and specificity of contrast-enhanced sonography in depicting flow in HCCs treated with TACE were 93% and 65%, respectively. The sensitivity and specificity of 3-phase CT were 64% and 100%. CONCLUSIONS: Contrast-enhanced sonography is a more sensitive imaging method than 3-phase CT in depicting vascularity in HCCs treated with TACE.

Adult↗

Can tumor contrast enhancement be used as a criterion for differentiating tumor grades of oligodendrogliomas?

BACKGROUND AND PURPOSE: The association of high-grade oligodendrogliomas with tumor contrast material enhancement on MR images has been reported. Some authors have even used contrast enhancement as a criterion for their oligodendroglioma grading system. The purpose of our study was to evaluate if tumor contrast enhancement is a specific finding for anaplastic oligodendroglioma. METHODS: Pretreatment MR images of 24 oligodendrogliomas were reviewed retrospectively, and findings were compared with the histologic grade. The presence or absence and the pattern of tumor contrast enhancement were evaluated qualitatively. A contrast enhancement ratio (CER), a quantitative criterion, was calculated to assess the difference in degree of enhancement between the low-grade and anaplastic tumors. Tumor grade was diagnosed at pathologic examination according to the World Health Organization classification system. RESULTS: Contrast enhancement was noted in nine (56%) of 16 low-grade tumors and in five (62%) of eight anaplastic tumors. A characteristic enhancement pattern, nodular-like enhancement, was found in eight tumors. The CERs were 2.12-40.88 (mean, 20.08) in low-grade tumors and were 3.20-62.52 (mean, 28.73) in anaplastic tumors (P > .05). CONCLUSION: Tumor contrast enhancement was not statistically significantly different between the tumor groups. We believe that the presence or absence of tumor contrast enhancement is not a specific finding for simply discriminating low-grade from anaplastic oligodendrogliomas. Histologic confirmation is necessary even in tumors without contrast enhancement.

Adolescent↗

Trigeminal ganglion and its divisions: detailed anatomic MR imaging with contrast-enhanced 3D constructive interference in the steady state sequences.

BACKGROUND AND PURPOSE: Visualization of the trigeminal system is important for imaging diagnosis but technically challenging. We assessed how well the trigeminal ganglion, its rootlets, and its branches (V1, V2, and V3) are depicted on three high-resolution pulse sequences. METHODS: Twenty-two patients (44 sides) underwent nonenhanced 3D constructive interference in the steady state (CISS) MR imaging. Two of these patients and another 20 (44 sides) also underwent contrast-enhanced 3D CISS and contrast-enhanced 3D time-of-flight (TOF) MR angiographic (MRA) imaging. Appearances of the ganglion, sinus ganglii, ganglion lip, and sensory and motor rootlets in the Meckel cave were assessed. RESULTS: The trigeminal ganglion was shown on enhanced 3D CISS images in all cases, on nonenhanced 3D CISS images in 77.3%, and on enhanced 3D TOF MRA images in 92.9%. Sinus ganglia and lips were demonstrated on 98% of enhanced 3D CISS images. Sensory rootlets were depicted with all 3D CISS sequences but no 3D TOF sequences. V1, V2, and V3 were displayed with all enhanced 3D TOF MRA sequences, 79.5-100% of enhanced 3D CISS sequences, and 0-50% of nonenhanced 3D CISS sequences. CONCLUSION: The enhanced 3D CISS sequence was best for displaying the trigeminal ganglion, sinus ganglii, and sinus lips, whereas the enhanced 3D TOF sequence best displayed the emerging V1, V2, and V3 roots. The enhanced 3D CISS sequence was most useful. Complete MR imaging evaluation of the trigeminal ganglion and roots is best performed by using enhanced 3D CISS and enhanced 3D TOF MRA sequences.

Adult↗

[Characterization of focal liver lesions using an innovative contrast-enhanced ultrasound technique].

OBJECTIVE: To evaluate the clinical performance of an innovative contrast-enhanced ultrasound (CEUS) technique in characterization of focal liver lesions (FLL). METHODS: CEUS was performed in 505 patients with FLLs. A sulfur hexafluoride-filled microbubble ultrasound contrast agent and a continuous real-time imaging technique of contrast pulse sequencing were used. The observation items included initial nodule enhancement time, enhancement level and pattern, and dynamic evolution of enhancement along with the CEUS phases. RESULTS: There were similar findings for both malignant and benign FLLs in initial enhancement time and enhancement level on CEUS. The dynamic evolution of enhancement along with enhancement phase was the most significant parameter for characterization of FLLs. Most malignant lesions showed enhancement at arterial phase and hypo-enhancing at late phase, whereas the benign lesions presented enhancement at arterial phase and persistent hyper- or iso-enhancing until late phase. Using these characteristics as a diagnostic criteria, the sensitivity, specificity, positive predicative value, negative predicative value and accuracy of CEUS in identifying malignant FLLs were 95.7% (313/327), 86.0% (153/178), 92.6% (313/338), 91.6% (153/167) and 92.3% (466/505), respectively. CONCLUSIONS: Characterization of FLLs by using the innovative CEUS technique is recommendable due to its safety, facility and high accuracy.

Adult↗

Characterization of a cell type-specific enhancer found in the human papilloma virus type 18 genome.

We have previously isolated long-range acting enhancer elements from the HeLa genome by functional selection. In this report, the structural and functional characteristics of one (GA1) of the enhancers are reported. By cloning various restriction fragments and by deletion mutagenesis, the activity of GA1 was located in a 230-bp region. The nucleotide sequence of GA1 and genomic Southern blot analysis indicated that GA1 is derived from human papilloma virus (HPV) 18 DNA that had been integrated into the HeLa genome. The enhancer is located in the non-coding region of the HPV 18 genome. The HPV 18 enhancer consists of two functional domains, both of which have full enhancer activity in HeLa cells. The enhancer does not contain enhancer core sequences but contains several blocks of potential Z-DNA sequence. Like SV40 and polyoma virus enhancers, the activity of the HPV 18 enhancer was repressed by adenovirus E1a products. The HPV 18 enhancer shows a narrow cell type specificity: it is active in some cervical carcinoma cell lines, but inactive in all non-cervical cells except for one neuroblastoma cell line. These results suggest that the HPV 18 enhancer plays an important role in regulation of the viral genes.

Adenovirus Early Proteins↗

Analysis of gene expression in mouse preimplantation embryos demonstrates that the primary role of enhancers is to relieve repression of promoters.

Enhancers are generally viewed simply as extensions of promoters, lacking a function of their own. However, previous studies of mouse preimplantation embryos revealed that 1-cell embryos can utilize enhancer-responsive promoters efficiently without an enhancer, whereas 2-cell embryos require an enhancer to achieve the same levels of expression. This suggested that enhancers relieved a repression in 2-cell embryos that is absent in 1-cell embryos. Results presented here demonstrate first that the ability of 1-cell embryos to dispense with enhancers does not result from the absence of specific activation proteins. Under conditions where GAL4-VP16 activated a GAL4-dependent promoter in both embryos, GAL4-VP16 activated a GAL4-dependent enhancer only in 2-cell embryos. Moreover, the role of an enhancer is not to compensate for either changes in promoter requirements, or for reduced levels of promoter-specific transcription factors. Linker-scanning mutations in a natural promoter revealed that both embryos utilized the same promoter elements, and comparison of different promoters revealed that these embryos have equivalent transcriptional capacities. In addition, titration experiments revealed less Sp1 activity in 1-cell embryos where enhancers are dispensable than in 2-cell embryos where enhancers are required. Therefore, we propose that the primary function of enhancers, first evident with formation of a mouse 2-cell embryo, is to prevent repression of weak promoters, probably by altering chromatin structure. Consistent with this hypothesis is the fact that butyrate, an agent that alters chromatin structure, stimulated promoters in 2-cell embryos, but not in 1-cell embryos.

Animals↗