Bileaflet mechanical heart valves at low cardiac output.

Several earlier studies have indicated that bileaflet mechanical heart valves behave irregularly at low cardiac output and low pulse rate conditions, and that their hydrodynamic performances are generally inadequate. The authors conducted in vitro experiments in a pulsatile mock circulatory loop to compare the performance of the St. Jude Medical (SJM) valve and a long body bileaflet prosthesis recently introduced by Medical Carbon Research Institute (MCRI) (Austin, TX). The new MCRI mechanical heart valve model was designed with emphasis on improved hydrodynamic efficacy by introducing a long body with parallel leaflets and by leaflets increasing the flow area. Experimental studies were conducted on five test valves (MCRI 19 mm, MCRI 25 mm, SJM 19 mm, SJM 23 mm, and SJM 29 mm) with cardiac outputs of 2.0, 2.5, 3.0, and 3.5 L/min at a pulse rate of 40 beats/min, and 3.5, 4.0, 4.5, and 5.0 L/min at a pulse rate of 70 beats/min. Transvalvular pressure drop and closure volume were assessed by measuring the instantaneous ventricular and aortic pressures and aortic flow. The leaflet motions of the tested valves were observed by direct video recording using a charge coupled device camera while the flow measurements were being conducted. Testing under simulated physiologic ventricular and aortic pressure waveforms, the results of this study show that the MCRI bileaflets remained fully open during the entire ejection phase, even at very low cardiac output conditions (2.0 L/min). The closure volume (defined as percentage of forward flow volume) increased with decreasing cardiac output, as reported earlier by others. Comparative results also indicate that the MCRI design has nearly a two size pressure drop advantage over the SJM, with significantly smaller closure volume.

Blood Flow Velocity↗

Parameters and methods for testing artificial heart valves.

The report describes the development of heart valve test standards. The aim is comprehensive quality assurance by in vitro tests. The project includes three test fields: general basis, development and definition of test methods and test devices and comparative in vitro assessment of valves for the definition of minimum requirements. A preliminary list of test parameters and test steps has been defined: geometrical, flow, deformation, force, and conditioning parameters. A system of geometrical parameters has been developed for standardized aortic models. Geometrical parameters of 31 valves of six types and different sizes underline a close correlation between geometrical and hemodynamic parameters. The relative ostium cross-section Ae/AT increases with valve size and lies between 0.3 and 0.5. Two new measurement devices with quasi-steady flow are proposed as quick testers for leakage flow and pressure loss.

Heart Valve Prosthesis↗

Impact of mechanical heart valve prosthesis sound on patients' quality of life.

BACKGROUND: The "click" sound of mechanical heart valve prostheses has been recognized as a disturbing factor for some patients after mechanical heart valve implantation. The factors determining the extent of disturbance remain controversial. METHODS: Ninety-five unmatched patients with six different valve types were examined (Duromedics-Edwards, Björk-Shiley, St. Jude Medical, Medtronic, CarboMedics, and Omnicarbon), including 12 patients with double-valve replacement. Three groups (Björk-Shiley, Duromedics-Edwards, and St. Jude Medical) were comparable in size. All patients were examined and interviewed, a hearing test was performed, and valve sounds were analyzed. Sound transmission was evaluated. RESULTS: The loudest valve was the Duromedics-Edwards prosthesis (mean, 84.2 dB[A] impulse) and the St. Jude Medical was the quietest (mean, 73.5 dB[A] impulse). This ranking was independent of patient variables and valve position. Discomfort level correlated with hearing loss and loudness of the valve. Patients desiring a quieter valve had better hearing, had louder valve sounds, felt disturbed by the sound, had partners who felt disturbed, and were receiving coumarin for anticoagulation. Sound was transmitted predominantly by air conduction. The frequency analysis to identify different valves was unsatisfactory, but louder frequencies did correspond with hearing-impaired patients' audiograms. CONCLUSIONS: Our results emphasize the need for valve design changes, preoperative education about the sound, and inclusion of routine hearing tests into the preoperative workup.

Adult↗

Relative blood damage in the three phases of a prosthetic heart valve flow cycle.

Blood flow through a prosthetic heart valve operating in a ventricular assist device can be subdivided into three phases: a) forward flow through an open valve, b) rapid valve closure, and c) regurgitant back flow through a closed valve. Recent studies of fluid stresses in the Penn State Electric Left Ventricular Assist Device (PS LVAD) operating under physiologic conditions indicate that Reynolds stresses of possibly hemolytic magnitude may exist in the valve area. Although several studies have been made of the fluid stresses seen in forward flow through an open valve, few have looked at valve closure or backflow, and none have related these stresses directly to blood damage. In this study, novel in vitro blood flow loops were developed to allow for the separate analysis of the three flow phases of a Bjork-Shiley monostrut Delrin disk valve operating in a PS LVAD. Forward flow through fully open aortic and mitral valves and backflow through closed valves are studied separately in flow loops driven by a roller pump with the LVAD acting as a valve housing and compliance vessel. Valve closure is investigated with a PS LVAD operating in a low volume mock circulatory loop characterized by cavitation potential through stroboscopic videography of this mock loop, using saline as the working fluid. Rate of hemolysis, characterized by the index of hemolysis, IH, is determined for each of the three flow loops charged with fresh porcine blood.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

In vivo demonstration of cavitation potential of a mechanical heart valve.

Cavitation is implicated as the cause of pitting and erosion of explanted mechanical heart valves that failed. Previous in vitro studies demonstrated transient negative pressure spikes upstream of mechanical heart valves at the instant of leaflet closure. When the magnitude of the transient negative pressure spike is below the vapor pressure of the fluid flowing across the mechanical valve, cavitation bubbles have been documented near the valve housing or occluder disc. To test for the presence of transient negative pressure spikes that are conducive to cavitation in vivo, we measured left atrial pressure at the valve orifice after mitral valve replacement. Mitral valves were replaced with 27 mm prostheses in 10 goats (50-60 kg). Control animals (Group 1, n = 5) received pericardial valves. Study animals (Group 2, n = 5) received bileaflet pyrolytic carbon valves. Pressure was recorded from a high frequency atrial transducer at hyperdynamic and hypodynamic states. Transient negative pressure spikes did not occur in any Group 1 animal. Transient negative pressure spikes below the vapor pressure of blood (-713 mm Hg) were recorded in four of five Group 2 animals at the hyperdynamic state: -900, -950, -800, -400, and -1,400 mm Hg (p = 0.048 Group 1 versus Group 2, Fisher's exact test). No cavitation potential exists in vivo after bioprosthetic valve implantation. Transient negative pressure spikes below the vapor pressure of blood occur in vivo at hyperdynamic physiologic states when this bileaflet pyrolytic carbon valve is implanted in the mitral position. These studies demonstrate the potential for cavitation with implanted mechanical valves in vivo.

Animals↗

Safety of outpatient dalteparin therapy in veterans with mechanical heart valves.

STUDY OBJECTIVES: To determine the rate of bleeding and thromboembolic events within 1 month of outpatient dalteparin therapy in veterans with mechanical heart valves, to evaluate potential risk factors associated with these events, and to examine the prescribing patterns of dalteparin in this patient population. DESIGN: Single-center retrospective electronic chart review. SETTING: Large, academically affiliated Veterans Affairs hospital. SUBJECTS: Thirty-eight men with mechanical heart valves who received outpatient prescriptions for dalteparin from October 1, 1998-June 30, 2003. MEASUREMENTS AND MAIN RESULTS: Charts were reviewed for thromboembolic and bleeding events. Demographic, clinical, and drug utilization variables were assessed. The associations of adverse events with potential risk factors, indication for dalteparin therapy, and prescribing clinic were analyzed. Sixty-four dalteparin regimens were evaluated. No thromboembolic events were reported in any case within 1 month after receiving dalteparin for thromboembolic prophylaxis during warfarin interruption for periprocedural anticoagulation or for anticoagulation during an unintentional subtherapeutic international normalized ratio. Bleeding events occurred in 15 (23%) of the 64 regimens. Most bleeding events resolved spontaneously and without intervention. No potential risk factors for bleeding were identified. CONCLUSION: Dalteparin appeared to be a safe, effective means of short-term thromboembolic prophylaxis in this population of ambulatory male veterans with mechanical heart valves. Large, randomized, controlled, prospective trials are warranted.

Aged↗

Helicobacter pylori and upper gastrointestinal bleed in heart valve surgery.

OBJECTIVE: This study was designed to evaluate objectively the incidence of Helicobacter pylori infection and upper gastrointestinal (GI) bleeding in patients following heart valve replacement surgery. Since the discovery of Helicobacter pylori, its association with gastritis, peptic ulceration and upper GI bleed have been extensively studied. Anticoagulation of patients with mechanical heart valve prostheses is a prerequisite for the prevention of valve thrombosis and thrombo-embolic events. However anticoagulation can have its complications, notably that of upper GI bleeding. METHODS: Patients were assessed in routine postoperative outpatient clinics following cardiac valve replacement surgery. This assessment comprised initially of a questionnaire reflecting the symptomatology of upper GI bleeding and its subsequent management. With informed consent, a small sample of blood was obtained by stilette. The Helicobacter pylori status was assessed by measuring the presence of antibodies (immunoglobins) to Helicobacter pylori in a commercially available test kit, the Rapid Helisal Test. In this preliminary study 150 consecutive patients were scrutinised and their responses to the questionnaire were collected and compared with the Helisal test. RESULTS: From the 150 patients studied, 37 patients were found to be positive to the Helisal test for Helicobacter pylori infection, representing 24.6% of all the cohorts. Of these 37 patients, eight gave a positive history of upper GI bleed; five requiring hospital admission with three requiring urgent upper GI endoscopy. Although these eight patients represent only 4.4% of the total group, it is significant to note that this represents 21.6% of those patients found to be Helicobacter pylori positive. There were no GI complications in any of those tested negative. There was an increasing incidence of Helicobacter pylori infection in the older age group of patients. CONCLUSIONS: Helicobacter pylori infection is a common infection with serious consequences in heart valve surgery. For those requiring anticoagulation, the incidence of serious consequential upper GI bleed is significantly higher in the presence of this infection. Preoperative or immediate postoperative eradication of the organism is mandatory in those patients requiring indefinite anticoagulation.

Adult↗

Quantitative analysis of human heart valves: does anorexigen exposure produce a distinctive morphological lesion?

The need for more detail regarding the clinical and morphological features of human heart valves has become evident due to recent controversy regarding anorexigen-associated valvular dysfunction. In the present study, we used quantitative digital image analysis of geometric and compositional features to compare the histopathology of cardiac valves excised from patients treated with anorexigens as compared to normal, floppy, rheumatic and carcinoid valves. Anorexigen-exposed valves had the greatest number of onlays/valve (P<.0001), while rheumatic valves showed the greatest average onlay size and thickness of the comparison groups studied (P=.01). The valve onlays from anorexigen-exposed, carcinoid and floppy valves contained a greater percentage of glycosaminoglycans (GAGs) as compared to normal and rheumatic valves (P=.01). The anorexigen-exposed valve propers contained more GAGs than any other comparison group (P=.02). Vessels were prominent in both onlay and valve proper regions of carcinoid valves, in the anorexigen-exposed valve onlays and in rheumatic valve propers. Thus, the number of onlays, their size, the degree of GAG deposition, and the presence and location of vessels and leukocytes were important features distinguishing anorexigen-exposed valves from normal valves. Discriminant analyses, based on geometry, color composition or color composition, and vessel and leukocyte counts combined, were able to separate the valves into distinguishable groups. Our findings demonstrate that specific microscopic features can be used to separate anorexigen-associated heart valve lesions from normal valves and valve lesions associated with other pathologies, and suggest that a distinctive pathological process may exist in many anorexigen-exposed valves.

Adolescent↗

Drug insight: an overview of current anticoagulation therapy after heart valve replacement.

Vitamin K antagonists, such as warfarin, are the gold standard approach for the long-term anticoagulant therapy of patients with mechanical heart valves. Management decisions are, however, based predominantly on expert consensus and on data from nonrandomized, follow-up studies, which have inherent limitations in their methods. Low-intensity anticoagulation therapy provides protection against thromboembolic complications in patients with most types of modern prosthetic heart valve. The addition of low-dose aspirin is safe if international normalized ratio values below 3.5 are maintained. A combined regimen should be considered in high-risk patients and those with coexistent coronary artery or cerebrovascular disease, and in patients who have suffered a thromboembolic event despite a therapeutic international normalized ratio. Thromboprophylaxis with unfractionated or low-molecular-weight heparins is restricted to specific situations, such as when a patient is intolerant to vitamin K antagonists, when surgical procedures require discontinuation of oral anticoagulation, or when the patient is pregnant. A lack of uniformity across practice guidelines make it difficult to reach treatment decisions. Each patient's preference, expressed after counseling about the risks and benefits of each treatment strategy, and an individual assessment of the patient's risk factors, should guide treatment decisions. At present, new anticoagulant agents such as factor Xa inhibitors do not represent a treatment option for heart valve recipients.

Anticoagulants↗

The complexity of external acoustic detection of defects in Björk-Shiley convexoconcave heart valves.

Fractures in Björk-Shiley convexoconcave (BScc) heart valves have raised questions about the feasibility of early diagnosis of technical defects by means of acoustic assessment. Three laboratory tests were conducted. To establish acoustic fingerprints, 66 valves with a defect, such as single-leg fracture (SLF) or single-leg separation (SLS), or without a defect were connected with a contact sensor and excited by dropping a small metal ball onto the outlet strut. In the second test, we simulated the valve sound propagation within the thorax. In the third test, intact, SLF, and SLS valves were placed in a mock heart immersed in a large water tank. We observed a resonance frequency corresponding with valve size and presence of defects. The second test showed that both the chest wall and the lungs created numerous reflections. This led to a substantial overlap of the original pulse frequencies and the frequencies measured. The third test confirmed that submersion of the chest in water can significantly reduce chest wall reflections. Reliable noninvasive assessment of BScc valve clicks for the presence of defects of the outlet strut is hampered by complex sound propagation within the thorax and variability of valve excitation. Acoustic fingerprints to diagnose mechanical defects should be integrated in valve design.

Heart Valve Prosthesis↗

[General surgery following heart valve replacement (author's transl)].

Patients with heart valve replacement regarding further surgical treatment are sub-divided into 3 groups. 1) Patients after open or closed reconstruction of valves with sinus rhythm and no anticoagulation.--2) Arrhythmic patient of the same kind but under anticoagulation.--3) Patients with valve replacement, who are under anticoagulation if there is no vital contraindication.--Group 1 and 2 may be operated on at every general hospital, provided cardiological supervision can be practiced. Until now patients of group 3 should always be treated in a cardiosurgical centre.

Anticoagulants↗

Steady flow dynamics of prosthetic aortic heart valves: a comparative evaluation with PIV techniques.

Particle Image Velocimetry (PIV), capable of providing full-field measurement of velocities and flow stresses, has become an invaluable tool in studying flow behaviour in prosthetic heart valves. This method was used to evaluate the performances of four prosthetic heart valves; a porcine bioprostheses, a caged ball valve, and two single leaflet tilting disc valves with different opening angles. Flow visualization techniques, combined with velocity vector fields and Reynolds stresses mappings in the aortic root obtained from PIV, and pressure measurements were used to give an overall picture of the flow field of the prosthetic heart valves under steady flow conditions. The porcine bioprostheses exhibited the highest pressure loss and Reynolds stresses of all the valves tested. This was mainly due to the reduction in orifice area caused by the valve mounting ring and the valve stents. For the tilting disc valves, a larger opening angle resulted in a smoother flow profile, and thus lower Reynolds stresses and pressure drops. The St. Vincent valve exhibited the lowest pressure drop and Reynolds stresses.

Algorithms↗

Immobilization of disc heart valves by unraveled sutures.

Disc immobilization by a prolapsed suture end was observed in a laboratory animal with a pivoting disc heart valve. An identical occurrence was experienced in a clinical situation by other investigators. These experiences prompted a review of sutures and suturing techniques in implanting disc heart valves, in an effort to ascertain the vulnerability of all disc valves toward disc immobilization by sutures. An attempt was made to immobilize the discs in five currently available heart disc valves with prolapsed sutures under various handling conditions. Variables included the model of disc valve, the location of the prolapsed suture, and the type of suture material used. Our investigation showed that any of the valves studied can be immobilized by prolapsed sutures. However, this complication is avoidable if the implanting surgeon adheres to a few precautionary suturing principles.

Animals↗

Prophylactic antibiotic therapy and heart valve replacement.

Patients undergoing cardiac bypass for heart valve replacement maintained adequate blood concentrations of cloxacillin throughout the duration of bypass, provided their initial blood concentration was in the therapeutic range. Blood levels related to the time between the last preoperative dose of antibiotic and operation. Maximal values were achieved if an intraoperative bolus of drug was given.

Adolescent↗

Changes in experimental atherosclerotic lesions of rat heart valves following long-term regression.

Regression of experimental atherosclerotic lesions of rat heart valves was studied in a long-term experiment. Following a period of regression of 12 months duration, the thick superficial layers of foam cells disappeared completely. Persisting masses of cholesterol crystals did not seem to be accompanied by any cellular proliferation or fibrous reaction. Such cholesterol deposits showed peculiar transparent cystoid areas probably representing local cholesterol dissolution. The structural differences between arterial and valvular plaques can be hypothetically explained by small numbers of smooth muscle cells in the heart valves.

Animals↗

[Cerebral embolia in patients with prosthetic mechanic heart valves].

The review focuses on embolia of cerebral vessels in patients with prosthetic mechanic heart valves. The highest risk for embolia is observed in the first 3 months after the surgery, a frequency of embolia being dependent on the type and position of the artificial valve. Methods for prevention of post-surgery thromboembolic complications are considered.

Heart Valve Diseases↗

Cavitation threshold with respect to dP/dt: evaluation in 29 mm bileaflet, pyrolitic carbon heart valves.

A total of 15 bileaflet mechanical heart valves were studied in a pulse duplicator at the Helmholtz Institute (Aachen, Germany) under conditions approximating first, a physiological pressure curve and subsequently, a sinusoidal pressure curve. In this study Edwards-Duromedics valves of the modified specification were compared with the earlier version of the Edwards-Duromedics valve as well as with St. Jude Medical valves. Each valve was tested at a series of nine (9) conditions. At each condition, without altering the valve installation or the systemic conditions, each valve was filmed by two separate video systems: the Helmholtz Institute strobe light system and a high speed video recording system. All data, as recorded by each system, was then independently analyzed by both of the two contributing groups and subsequently compared. In this manner, it was possible to objectively verify not only the consistency of the data obtained, but to also determine the relative reliability of the methods for cavitation threshold detection.

Carbon↗

A method for real-time in vitro observation of cavitation on prosthetic heart valves.

A method for real-time in vitro observation of cavitation on a prosthetic heart valve has been developed. Cavitation of four blood analog fluids (distilled water, aqueous glycerin, aqueous polyacrylamide, and aqueous xanthan gum) has been documented for a Medtronic/Hall prosthetic heart valve. This method employed a Penn State Electrical Ventricular Assist Device in a mock circulatory loop that was operated in a partial filling mode associated with reduced atrial filling pressure. The observations were made on a valve that was located in the mitral position, with the cavitation occurring on the inlet side after valve closure on every cycle. Stroboscopic videography was used to document the cavity life cycle. Bubble cavitation was observed on the valve occluder face. Vortex cavitation was observed at two locations in the vicinity of the valve occluder and housing. For each fluid, cavity growth and collapse occurred in less than one millisecond, which provides strong evidence that the cavitation is vaporous rather than gaseous. The cavity duration time was found to decrease with increasing atrial pressure at constant aortic pressure and beat rate. The area of cavitation was found to decrease with increasing delay time at a constant aortic pressure, atrial pressure, and beat rate. Cavitation was found to occur in each of the fluids, with the most cavitation seen in the Newtonian fluids (distilled water and aqueous glycerin).

Blood Viscosity↗