Bound whispering gallery modes in circular arrays of dielectric spherical particles.

Low-dimensional ordered arrays of optical elements can possess bound modes having an extremely high quality factor. Typically, these arrays consist of metal elements which have significantly high light absorption thus restricting performance. In this paper we address the following question: can bound modes be formed in dielectric systems where the absorption of light is negligible? Our investigation of circular arrays of spherical particles shows that (1) high quality modes in an array of ten or more particles can be attained at least for a refractive index n(r) > 2, so optical materials like TiO2 or GaAs can be used; (2) the most bound modes have nearly transverse polarization perpendicular to the circular plane; (3) in a particularly interesting case of TiO2 particles (rutile phase, n(r) = 2.7), the quality factor of the most bound mode increases almost by an order of magnitude with the addition of ten extra particles, while for particles made of GaAs the quality factor increases by almost two orders of magnitude with the addition of ten extra particles. We hope that this preliminary study will stimulate experimental investigations of bound modes in low-dimensional arrays of dielectric particles.

Journal Article↗

Non-quantitative morphologic features in normal and glaucomatous optic discs.

Glaucoma is associated with changes of the optic disc topography. Using color stereo photographs we examined non-quantitative signs in 584 optic discs of 308 patients with chronic primary open-angle glaucoma and in 383 optic discs of 236 age and refraction matched normal subjects. Only one eye per patient and normal subject was chosen for statistical analysis. Highest predictive value to differentiate between normal and glaucoma eyes had the parameters 'changes in the juxtapapillary retinal nerve fiber layers' (86.7%), 'abnormal size (79.8%) and abnormal location (68.6%) of the parapapillary chorio-retinal atrophy', 'smallest neuroretinal rim part outside of the temporal horizontal disc sector' (78.5%), and area with cupping larger than area with pallor' (68.2%). Characteristics with high specificity and low sensitivity were 'optic disc haemorrhages', 'bared cilioretinal arteries', and 'bared circumlinear vessels'. With their evaluation being independent of sophisticated techniques the non-quantitative parameters are helpful for the ad hoc diagnosis of glaucomatous optic nerve damage.

Adult↗

Chick eye optics: zero to fourteen days.

Ocular dimensions and refractive state data for chicks 0 to 14 days of age were obtained from 234 untreated control eyes of birds treated unilaterally in previous work involving various defocussing lenses and/or translucent goggles. Refractive state and corneal curvatures were measured in vivo by retinoscopy and ophthalmometry respectively. Intraocular dimensions were measured by A-scan ultrasonography, after which the eyes were removed, weighed and measured. In some cases (n = 52) intraocular dimensions and lens curvatures were obtained from frozen sections of enucleated eyes. The hyperopia of hatchling chicks (+6.5 +/- 4.0 D) initially decreases rapidly and then more gradually to +2.0 +/- 0.5 D by 16 days. The distribution of refractive errors is very broad at Day 0, but becomes leptokurtotic, with a slight myopic skew, by Day 14. Corneal radius is constant for the first four days, possible as a result of pre-hatching lid pressure, and then increases linearly, as do all lens dimensions, axial diameter and equatorial diameter. Schematic eyes were developed for Days 0, 7, and 14.

Animals↗

Mathematical model for predicting dioptric effects of optical parameter changes in the eye.

Changes in refractive status induced by contact lenses have been attributed to changes in various intraocular comonents. Limitation of previous mathematical attempts to quantify the effects of changes in these components are discussed. A series of simple ray-tracing equations is developed which avoids these limitations and provides a practical means of relating calculations to clinical measurements.

Anterior Chamber↗

Refractive power of a multilayer rotationally symmetric model of the human cornea and tear film.

Optical models of the human cornea and tear film typically employ a single homogeneous cornea with an average refractive index. I propose to use a more realistic multilayer model based on morphological data from the literature. The mathematical methodology to derive the refractive power equation of this model is presented. Special attention is given to the axial gradient index of the refraction structure of the stroma layer because of its optical implications. The importance of considering this multilayer model is quantified in a specific example (orthokeratology) with the help of the derived power equation.

Computer Simulation↗

Nondestructive imaging of a type I optical fiber Bragg grating.

Nondestructive images of refractive-index variation within a type I fiber Bragg grating have been recorded by the differential interference contrast imaging technique. The images reveal detailed structure within the fiber core that is consistent with the formation of Talbot planes in the diffraction pattern behind the phase mask that had been used to fabricate the grating.

Journal Article↗

[An analytical study of optical conditions of the elderly].

The visual acuity, refraction and related factors in 471 eyes 60-90 years of age were analyzed with the authors's statistical method for refractive data. The mean logarithmic visual acuity (Lv) of all eyes naked was 4.66 (equivalent to 20/44, or 6/13), and with corrections 5.03 (equivalent to 20/18.7, or 6/5.6). There was significant negative linear correlation between Lv and age (r = -0.9684), Lv = 5.7183-0.0095 x age. The percentages of hyperopia and myopia in the series were 47.8% and 39.7%, the mean refraction being +0.96 DS +0.78 DC and -1.29 DS -0.95 DC respectively. The percentage of mixed astigmatism was 7.86%, averaging +0.71 DC -0.74 DC. The mean refraction of all the patients was -0.05 +/- 2.90 DS -0.04 +/- 1.14 DC.

Age Factors↗

Low-power intraocular lens implantation in patients with cataracts and age-related macular degeneration.

Three patients with age-related macular degeneration for whom cataract surgery was indicated received low-power intraocular lenses (IOLs) calculated to produce an end spectacle refraction of approximately +6 diopters, producing a magnification of about 12%. Our experience with these three cases suggests that use of low-power implants in such patients may yield better results than emmetropic IOLs.

Aged↗

Ocular findings in lissencephaly.

PURPOSE: To report our retrospective study of 20 cases with lissencephaly and describe ocular and visual abnormalities associated with this disorder. METHODS: Patients with lissencephaly were identified and classified into classic (type I) or cobblestone (type 2) lissencephaly on the basis of a review of clinical records and neuroimaging studies. Only patients examined by an ophthalmologist were included in the study. RESULTS: Only 1 patient had a normal ocular examination. Ocular abnormalities included optic nerve hypoplasia and atrophy, retinal dysplasia, retinal nonattachment, macular hypoplasia, anterior segment malformation, and strabismus. CONCLUSIONS: Ocular abnormalities in classic (type 1) lissencephaly are less severe. Central, steady, and maintained fixation may be present despite the presence of optic nerve hypoplasia, optic atrophy, macular hypoplasia, strabismus, or refractive errors. Retinal and anterior segment abnormalities were observed only in cobblestone (type 2) lissencephaly. These patients often have severe visual impairment because of retinal or cortical disease.

Abnormalities, Multiple↗

Measuring optical properties of an eye lens using magnetic resonance imaging.

We compare the focal lengths of porcine lenses measured optically and by using a novel MRI technique. The geometric properties of the lenses were also measured and compared. The MRI technique exploits the dependence of both the lens refractive index and relaxation rates on the local protein concentration. By measuring the refractive index and corresponding values of R2 (=1/T2) for samples of lens homogenates with different protein concentrations, the dependence of refractive index on R2 was determined empirically. R2 maps, constructed from monoexponential fits to multiecho images of a slice through the lens containing the optical axis, were converted to refractive index maps using this relationship. A simulated ray trace through the refractive index map provided an estimate of lens focal length that was compared to a direct optical measurement of focal length using a laser ray-tracing method. It was found that the mean focal lengths estimated from the two techniques agreed within experimental uncertainty. The refractive index profile along the optical axis was found to be well described by a simple function of the form n=n0 + n1 x ra where r is the (normalized) lens radius.

Animals↗

Ocular anatomy and refraction.

An examination is made of possible relations between ocular morphology and refraction in man. Special attention is paid to astigmatism, prematurity, the eye at birth, and differences as between the eyes of men and women respectively. Some functional correlates are also pointed out.

Adolescent↗

Performance of fluorescence correlation spectroscopy for measuring diffusion and concentration.

Fluorescence correlation spectroscopy (FCS) has become an important tool for measuring diffusion, concentration, and molecular interactions of cellular components. The interpretation of FCS data critically depends on the measurement set-up. Here, we present a rigorous theory of FCS based on exact wave-optical calculations. Six of the most important optical and photophysical factors that influence FCS are studied: fluorescence anisotropy, cover-slide thickness, refractive index of the sample, laser-beam geometry, optical saturation, and pinhole adjustment. Our theoretical framework represents a general attempt to link all relevant parameters of the experimental set-up with the measured correlation function.

Diffusion↗

Refractive index measurements of films with biaxial symmetry. 2. Determination of film thickness and refractive indices using polarized transmission spectra in the transparent wavelength range.

A technique is formulated to determine both thickness and refractive indices of free-standing films with biaxial symmetry from polarized transmission spectra. The films must be transparent and show little dispersion in refractive indices in the wavelength range where the transmission spectra are collected. Methods are proposed to correct the errors caused by imperfect polarization of incident radiation and thickness variation across the sampling area. Anisotropic refractive indices and thickness of poly(biphenyl dianhydride-p-phenylenediamine) films which exhibit uniaxial optical anisotropy are determined from polarized transmission spectra. The refractive index and thickness values compare well to those obtained from waveguide prism coupler and profilometer measurements.

Journal Article↗

Comparison of portable automated keratometry and manual keratometry for IOL calculation.

PURPOSE: To compare the accuracy of portable automated keratometry (PAK) with that of manual keratometry (MK) in measuring corneal power for intraocular lens calculations. SETTING: Wilford Hall Medical Center, San Antonio, Texas, USA. METHODS: In Part 1 of the study, five ophthalmic technicians performed keratometric analysis in 20 eyes in 10 volunteers using both manual and automated methods to determine the relative accuracy and reproducibility of each instrument. In Part 2, both MK and PAK were prospectively performed in 11 patients having cataract surgery to compare the accuracy of each instrument in predicting postoperative refractive outcome. RESULTS: The difference between instruments in determining the average corneal power in all eyes was less than 0.10 diopter (D) (MK = 43.84 D, PAK = 43.93 D). Portable keratometry demonstrated less variability in measurements in each eye (average standard deviation, MK = 0.30 D, PAK = 0.11 D; average range, MK = 1.08 D, PAK = 0.44 D). The mean absolute refractive error (difference between the actual refractive outcome and predicted refractive outcome) was 0.37 D +/- 0.30 (SD) using MK values and 0.45 +/- 0.19 D using PAK values. CONCLUSIONS: Portable automated keratometry is a simple keratometric technique that appeared to be as accurate as but with less variability than manual keratometry in determining corneal power for cataract surgery.

Algorithms↗

Ocular dimensions and schematic eyes of freshwater and sea turtles.

Measurements were made of the ocular dimensions from living and frozen eyes of one species of freshwater turtle, Pseudemys scripta elegans, and of three species of marine turtles, Chelonia mydas, Dermochelys cariacea, and Eretmochelys imbricata. Estimates of refractive error by retinoscopy were also obtained with eyes in air and under water. The results suggest that unaccommodated eyes of all four species are approximately emmetropic in air but strongly hyperopic in water. Schematic eyes were calculated for each species in both air and water.

Adaptation, Physiological↗

[Intraoperative skiascopy for determining the refractive value of an implantable intraocular lens].

BACKGROUND: Preoperative biometry for calculation of the refractive power of intraocular lenses is not sufficiently reliable in certain cases. Most frequently inaccuracies tend to occur in highly myopic eyes. Preceding refractive procedures can also impair IOL-calculation or even make it impossible. PATIENTS: In a highly myopic patient IOL-power calculation was not possible with conventional calculation formulas due to a preexisting refractive silicone lens located between the cataractuous natural lens and the iris. In another myopic patient ultrasound measurement of axial eye length produced variable and unreliable results. Therefore retinoscopy was performed intraoperatively in the aphakic eye. Refractive power of the IOL was calculated using a new formula. For validation of the method retinoscopy was performed intraoperatively in a second group of 11 patients with unproblematic ultrasound biometry. RESULTS: In 3 eyes IOL power was chosen according to intraoperative retinoscopy. A maximal deviation of 1.25 D from the aimed refraction resulted. In the second group, the retinoscopic method produced partially considerably inaccurate results as compared to the ultrasound biometry. Inaccuracies increased with the extent of hyperopia. CONCLUSIONS: In cases of difficult or inaccurate preoperative ultrasound biometry IOL power can be estimated after intraoperative retinoscopy in the aphacic highly myopic eye. IOL power can be calculated instantly using computer programs or tables. This method additionally enables the surgeon to control the refractive result of intraocular lens implantation prior to wound closure. However this method lacks reliability in higher hyperopic eyes, as in these cases small changes in corneal vertex distance of the lens used for retinoscopy highly alter the result.

Adult↗

[Correction of ametropia following early surgery of congenital cataract].

Variants of an approach towards choosing the means for aphakia correction after an early surgery for congenital cataract, made during the first life year of infant, are presented in the case study. The main requirements, which must be applicable to a correction method under the mentioned conditions, are substantiated. The key advantages of contact lenses are shown, from such stand point, versus other correction methods, including spectacles, intraocular lenses and refractive epikeratoplasty. Unstable anatomic-and-optic ocular parameters in the first-year life infants are the principle obstacle for the primary IOL implantation. The issue on a secondary IOL implantation must be individually decided at the age of 10 to 12.

Adolescent↗