PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Serum adiponectin is associated with high-density lipoprotein cholesterol, triglycerides, and low-density lipoprotein particle size in young healthy men.

The chromosomal localization of adiponectin has been found to be mapped to human chromosome 1q21.4-1q23, a region that was identified as a susceptibility locus for familial combined hyperlipidemia and polygenic type 2 diabetes. As these 2 disorders are associated with low high-density lipoprotein (HDL)-cholesterol, high triglycerides, and insulin resistance (IR), we examined the relation of serum adiponectin concentrations to serum lipid and lipoprotein profiles as well as IR in young healthy men. Serum adiponectin levels were positively associated with HDL-cholesterol, apolipoprotein (apo) A1, and low-density lipoprotein (LDL) particle size, and negatively associated with triglycerides and apo B. Negative associations were also found between adiponectin and body mass index (BMI), percent body fat, and IR,as determined by homeostasis model assessment (HOMA). However, after adjustment for BMI, no significant associations were found between adiponectin and LDL particle size and apo B. In a multiple regression analysis including all variables that showed significant univariate associations with adiponectin, associations of adiponectin with HDL-cholesterol (beta = 0.079, P =.0009), percent body fat (beta = -0.165, P =.002), and serum leptin (beta = -0.291, P =.01) were statistically significant. HDL-cholesterol (beta = 0.077, P =.001), percent body fat (beta = -0.078, P =.03), and LDL size (beta = 0.092, P =.03) emerged as significant and independent determinants of adiponectin after HOMA IR, fasting glucose, triglycerides, and systolic blood pressure (BP) were taken into account. Together, these variables explained 19% of adiponectin variability in the 2 models. HOMA IR did not emerge as a determinant of adiponectin in both models. These findings suggest that in young healthy men hypoadiponectinemia is more closely related to adiposity and dyslipidemia than IR.

Adiponectin↗

Influence of dietary calcium level and particle size of calcium source on in vivo calcium solubilization by commercial Leghorns.

Six experiments were conducted in which hens with oviposition times between 0730 h and 0930 h were intubated with limestone at different levels or particle sizes at time of oviposition. Feed was withdrawn from all hens approximately 15.5 to 17.5 h prior to intubation, and the same feed but without supplemental Ca was immediately returned after limestone intubation. Excrement of each hen was collected from intubation (oviposition) until the next oviposition (24 to 27 h duration) in all experiments except Experiment 4. In Experiment 4, excreta were collected for 25 h after first oviposition. Five hens prior to intubation of Ca source and all hens at termination of an experiment were killed, and the contents of the digestive system were collected. Excreta and digestive system contents were analyzed for total Ca and quantity of insolubilized limestone. Approximately 50% of the Ca found in the excreta from hens with 3.75 g Ca intake was recovered in the same form as ingested (limestone). Percentage of Ca solubilized in the digestive system decreased (P less than .05) as Ca intake increased. Although in vitro solubility of larger limestone particles (2 to 5 mm) was much less than smaller particles (.5 to .8 mm), percentage of Ca solubilized in the digestive system during the 25 h following intubation increased (P less than .05) as particle size increased, suggesting a greater retention time of the larger limestone particles in the gizzard.

Animals↗

Decrease in the particle size of low-density lipoprotein (LDL) by oxidation.

A radical reaction of low-density lipoprotein (LDL) causes fragmentation and cross-link of apolipoprotein B-100 (apoB). LDL (50 microg/ml) was subjected to the well-studied oxidation with Cu(2+) (1.67 microM). The concentration of alpha-tocopherol decreased to 10% of the initial level during the first 30 min. After this lag time, the conjugated diene content, as measured by absorption at 234 nm, started increasing and the residual apoB at 512 kDa determined by immunoblot after SDS-PAGE (sodium dodecylsulfate-polyacrylamide gel electrophoresis) was also decreased. The particle size of LDL determined by nondenaturing gradient gel electrophoresis decreased steadily during the initial 120 min, when residual native apoB was only 30% of the initial level. Plasma was also oxidized with Cu(2+) (400 microM). Under this condition, a clear lag time was not observed and alpha-tocopherol content, apoB, and the LDL particle size were decreased simultaneously. Based on these experiments, we propose that an oxidation reaction is involved in the formation of small dense LDL.

Blotting, Western↗

Effect of grinding with hydroxypropyl cellulose on the dissolution and particle size of a poorly water-soluble drug.

A new benzofuroquinoline derivative, 3,9-bis(N,N-dimethylcarbamoyloxy)-5H-benzofuro[3,2-c]quinoli ne-6-one (KCA-098), shows poor oral absorption due to practical insolubility in water. In this study, a co-grinding technique employing a water-soluble polymer was used for improvement of the dissolution rate of KCA-098. Powder X-ray diffraction patterns and IR spectra of KCA-098 showed the conversion of the drug from a crystal state to an amorphous state by grinding with a polymer such as hydroxypropyl cellulose (HPC-SL) or polyvinylpyrrolidone (PVP K30). The particle size of KCA-098 was remarkably reduced to a submicron size by grinding with HPC-SL. The co-ground mixture with HPC-SL showed a rapid dissolution rate and maintained supersaturation for more than 1 h. On the other hand, the co-ground mixture with PVP K30 showed rapid dissolution and supersaturation for a shorter period. These data suggest that the rapid dissolution rate was obtained by the conversion of the drug particles from a crystal to amorphous state by grinding with water-soluble polymers and that a reduction in particle size to the submicron level led to the maintenance of supersaturation due to good dispersion.

Cellulose↗

Breath hydrogen and methane responses of men and women to breads made with white flour or whole wheat flours of different particle sizes.

OBJECTIVE: While it is well known that consumption of whole grain foods results in beneficial health effects, the great majority of Americans prefer bread made with white flour. Consumption of whole grain foods in high fiber menus may cause undesirable intestinal responses. The purpose of this study was to determine whether consumption of bread made with ultra fine ground whole wheat flour retained beneficial effects while reducing undesirable effects. METHODS: Twenty-six men and women (31 to 55 years of age) consumed glucose solutions or bread made with white, whole wheat or fine ground whole wheat flour (1 g carbohydrate/kg body weight) in a Latin square design after two days of controlled diet. Breath methane and hydrogen were determined over the 24 hours after consumption of test foods. RESULTS: Hydrogen and methane responses of men and women were similar. There were no significant differences in methane responses to the different treatments, but hydrogen response was increased by all breads (p<0.0001). Although the overall mean response values were similar for all three breads, the patterns of hydrogen response differed (treatment*time, p<0.003). Gastrointestinal symptoms were not associated with fiber content or particle size of bread; however, subjects reporting symptoms tended to have higher methane responses (0.05<p<0.10). CONCLUSION: Neither fiber content of bread nor particle size of whole wheat flour substantially affected breath hydrogen or methane responses or gastrointestinal symptoms. Fine ground whole wheat breads may provide a more acceptable food choice than standard whole wheat bread without sacrificing the beneficial health effects of higher fiber.

Adult↗

Laser-induced breakdown spectroscopy (LIBS) for carbon single shot analysis of micrometer-sized particles.

The purpose of this work is to study the ability of the laser-induced breakdown spectroscopy (LIBS) technique to perform in situ (without sample preparation) detection of graphite particles circulating in a gas loop used to simulate the cooling gas circuit of a helium-cooled nuclear reactor. Results obtained with a laboratory scale set up are presented. The experiments were performed in nitrogen with micrometer-sized particles containing carbon (glucose particles and sodium hydrogenocarbonate particles). Statistical shot to shot analysis was used to determine the concentration of the analyte. The variation of LIBS signal as a function of glucose particle diameter showed an underestimation of the signal of particles of diameters larger than 5 microm. This phenomenon is likely to be correlated to an incomplete vaporization in the laser-induced plasma of particles of sizes above 5 microm. Analytical measurements were performed with glucose particles and sodium hydrogenocarbonate particles, and the concentration-based limit of detection of carbon was evaluated to be about 60 microg m(-3).

Journal Article↗

[Effect of hay particle size at different concentrations and feeding levels on digestive processes and feed intake in ruminants. 1. Chewing activity and fermentation in the rumen].

In order to study the main effects of particle size three ruminally fistulated cows were fed a hay rich in fibre in long (28.7 mm), chopped (9.2 mm) and ground (2.9 mm) form in a 3 x 3 Latin square design. In another three factorial experiment with 8 wethers (4 animals were ruminally fistulated) the main effects and interactions of the above mentioned hay particle size at two concentrate levels (10.4 to 13.3 and 29.5 to 40.1% in the ration) and at two feeding levels (restricted and ad libitum) were investigated. There was no effect of chopped hay (9.2 mm) on chewing activity, whereas ground hay (2.9 mm) reduced rumination time (52% in sheep and 36% in dairy cows) and chewing expense (time/unit of DM or NDF intake). These effects were more pronounced at high concentrate intake. Sheep increased feed intake more through reduction of rumination expense than through the extension of rumination time. pH-value, concentration of bicarbonate and C2:C3-ratio indicate favourable fermentation conditions in long (28.7 mm) and chopped hay (9.2 mm), whereas a negative influence of ground hay (2.9 mm) or ruminal fermentation could be observed.

Animal Feed↗

Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: comparison of Andersen 8-stage cascade impactor, next generation pharmaceutical impactor, and model 3321 Aerodynamic Particle Sizer aerosol spectrometer.

The purpose of this research was to compare three different methods for the aerodynamic assessment of (1) chloroflurocarbon (CFC)--fluticasone propionate (Flovent), (2) CFC-sodium cromoglycate (Intal), and (3) hydrofluoroalkane (HFA)--beclomethasone dipropionate (Qvar) delivered by pressurized metered dose inhaler. Particle size distributions were compared determining mass median aerodynamic diameter (MMAD), geometric standard deviation (GSD), and fine particle fraction <4.7 microm aerodynamic diameter (FPF(<4.7 microm)). Next Generation Pharmaceutical Impactor (NGI)-size distributions for Flovent comprised finer particles than determined by Andersen 8-stage impactor (ACI) (MMAD = 2.0 +/- 0.05 micro m [NGI]; 2.8 +/- 0.07 microm [ACI]); however, FPF(<4.7 microm) by both impactors was in the narrow range 88% to 93%. Size distribution agreement for Intal was better (MMAD = 4.3 +/- 0.19 microm (NGI), 4.2 +/- 0.13 microm (ACI), with FPF(<4.7 microm) ranging from 52% to 60%. The Aerodynamic Particle Sizer (APS) undersized aerosols produced with either formulation (MMAD = 1.8 +/- 0.07 micro m and 3.2 +/- 0.02 micro m for Flovent and Intal, respectively), but values of FPF(<4.7 microm)from the single-stage impactor (SSI) located at the inlet to the APS (82.9% +/- 2.1% [Flovent], 46.4% +/- 2.4% [Intal]) were fairly close to corresponding data from the multi-stage impactors. APS-measured size distributions for Qvar (MMAD = 1.0 +/- 0.03 micro m; FPF(<4.7 micro m)= 96.4% +/- 2.5%), were in fair agreement with both NGI (MMAD = 0.9 +/- 0.03 micro m; FPF(<4.7 microm)= 96.7% +/- 0.7%), and ACI (MMAD = 1.2 +/- 0.02 microm, FPF(<4.7 microm)= 98% +/- 0.5%), but FPF(<4.7 microm) from the SSI (67.1% +/- 4.1%) was lower than expected, based on equivalent data obtained by the other techniques. Particle bounce, incomplete evaporation of volatile constituents and the presence of surfactant particles are factors that may be responsible for discrepancies between the techniques.

Administration, Inhalation↗

Association of the APOLIPOPROTEIN A1/C3/A4/A5 gene cluster with triglyceride levels and LDL particle size in familial combined hyperlipidemia.

The APOLIPOPROTEIN (APO)A1/C3/A4/A5 gene cluster on chromosome 11 has been hypothesized to be a modifier of plasma triglycerides in FCH. In the present study, we extended previous association analyses of the gene cluster to include APOA5, a newly discovered member of the cluster. Eight SNPs across the APOA1/C3/A4/A5 gene region were analyzed in 78 FCH probands and their normolipidemic spouses as well as in 27 Dutch FCH families. Of the individual SNPs tested in the case-control panel, the strongest evidence of association was obtained with SNPs in APOA1 (P=0.001) and APOA5 (P=0.001). A single haplotype defined by a missense mutation in APOA5 was enriched 3-fold in FCH probands when compared with the normolipidemic spouses (P=0.001) and a second haplotype was significantly enriched in the spouses (P=0.001). Family-based tests also indicated significant association of triglyceride levels and LDL particle size with the investigated SNPs of APOC3 and APOA5. These findings suggest that genetic variation in the APOA1/C3/A4/A5 gene cluster acts as a modifier of plasma triglyceride levels and LDL particle size within FCH families and furthermore indicate that a number of haplotypes may contribute to FCH.

Adult↗

Measurement of particle-size distribution and concentration in heterogeneous turbid media with multispectral diffuse optical tomography.

We present a method that is capable of extracting particle-size distribution (PSD) and concentration in heterogeneous turbid media by use of multispectral diffuse optical tomography (MSDOT). After the spectroscopic scattering images of the heterogeneous turbid media are obtained with MSDOT, the morphologic information of particles in the heterogeneities is recovered with an iterative regularized reconstruction algorithm based on Mie scattering theory when a particular form of PSD is assumed (Gaussian distribution is used in this study). The method described is tested and evaluated with both simulated and experimental data. The simulations are intended to test the sensitivity of the overall approach to noise effect. A series of phantom experiments are conducted with our newly developed ten-wavelength MSDOT system. Polystyrene microsphere suspensions contain particles of varying size from 2 to 6 microm as targets are embedded in a scattering background medium in these experiments. To achieve optimized results from experimental data, we developed a data preprocessing method for MSDOT as well as a scheme for calibrating scattering spectra. The results from both simulations and experiments show that the particle mean size and concentration can be reconstructed with acceptable accuracy, whereas the recovery of the standard deviation is sensitive to noise effect and can be as large as 86% from the experimental data.

Algorithms↗

Determining particle size distributions in the inhalable size range for wood dust collected by air samplers.

In the absence of methods for determining particle size distributions in the inhalable size range with good discrimination, the samples collected by personal air sampling devices can only be characterized by their total mass. This parameter gives no information regarding the size distribution of the aerosol or the size-selection characteristics of different samplers in field use conditions. A method is described where the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood dust particles which are generally large and close to rectangular prisms in shape. Over 200 wood dust samples have been collected in three different wood-products industries, using the traditional closed-face polystyrene/acrylonitrile cassette, the Institute of Occupational Medicine inhalable sampler, and the Button sampler developed by the University of Cincinnati. A portion of these samples has been analyzed to determine the limitations of this method. Extensive quality control measures are being developed to improve the robustness of the procedure, and preliminary results suggest the method has an accuracy similar to that required of National Institute for Occupational Safety and Health (NIOSH) methods. The results should provide valuable insights into the collection characteristics of the samplers and the impact of these characteristics on comparison of sampler results to present and potential future limit values. The NIOSH Deep South Education and Research Center has a focus on research into hazards of the forestry and associated wood-products industry, and it is hoped to expand this activity in the future.

Air Movements↗

Analysis of the particle size distribution and internal volume of liposomal preparations.

In this work we studied the particle size distribution of three liposomal preparations by quasi-elastic light scattering spectroscopy. Sized unilamellar vesicles of small diameter (s-SUV) were prepared by ultrasonication and subsequent centrifugation followed by extrusion through polycarbonate membranes of 0.2-micron pore size. Large unilamellar vesicles were obtained by reversed-phase evaporation (REV) and extrusion through polycarbonate filters with or without preliminary freezing-thawing cycles (VETI and VETII, respectively). After preparation, REV were sized to small diameter REV (s-REV) by extrusion through 0.4- and 0.2-micron polycarbonate membranes. According to the results, the s-SUV preparations were made up of two subpopulations, the major of which consisted of vesicles that were 26 nm in mean diameter and accounted for 95% of the overall s-SUV population. The s-REV dispersions always resolved into two populations centered at 120 and 380 nm, the relative proportions of which depended on the pore size of the filters used. VET structures were composed of a single population of vesicles that were approximately 100 nm in mean diameter. Cholesterol inclusion into the bilayer composition extended the distribution without altering its mean value. On the other hand, the internal volumes calculated from mean diameters or assuming a Gaussian distribution were inconsistent with experimental data obtained by usual techniques.

Liposomes↗

Estimations of average particle sizes and size distributions of commercially available human-insulin aqueous suspensions using laser-light diffraction spectroscopy.

The average diameter and size distribution of particles in commercially available isophane-insulin and zinc-insulin aqueous suspensions (11 products) were examined using laser-light diffraction spectroscopy (LLDS). Wide variation was observed between products in volume-weighted and number-weighted average diameters. The particles in the insulin aqueous suspensions were found to be mono-dispersed within relatively narrow size distributions. Sonication for a short time led to a downshift in the apparent average diameter, which was most remarkable with isophane-insulin aqueous suspensions. This could be ascribed to dispersion of aggregated needle-like crystals and/or crystal breakage. In the case of biphasic isophane-insulin aqueous suspensions, the average size as well as the size distribution shifted toward the smaller end of the scale with decrease in the isophane content.

Humans↗

Submicrometer Particle Sizing by Multiangle Light Scattering following Fractionation

The acid test for any particle sizing technique is its ability to determine the differential number fraction size distribution of a simple, well-defined sample. The very best characterized polystyrene latex sphere standards have been measured extensively using transmission electron microscope (TEM) images of a large subpopulation of such samples or by means of the electrostatic classification method as refined at the National Institute of Standards and Technology. The great success, in the past decade, of on-line multiangle light scattering (MALS) detection combined with size exclusion chromatography for the measurement of polymer mass and size distributions suggested, in the early 1990s, that a similar attack for particle characterization might prove useful as well. At that time, fractionation of particles was achievable by capillary hydrodynamic chromatography (CHDF) and field flow fractionation (FFF) methods. The latter has proven most useful when combined with MALS to provide accurate differential number fraction size distributions for a broad range of particle classes. The MALS/FFF combination provides unique advantages and precision relative to FFF, photon correlation spectroscopy, and CHDF techniques used alone. For many classes of particles, resolution of the MALS/FFF combination far exceeds that of TEM measurements. Copyright 1998 Academic Press. Copyright 1998Academic Press

Journal Article↗

Hepatic uptake of polystyrene microspheres in rats: effect of particle size on intrahepatic distribution.

The in vivo disposition of polystyrene microsphere (MS) with the particle size of 50 nm (MS-50) or 500 nm (MS-500) was characterized after intravenous administration to rats. A rapid elimination from systemic circulation was observed for both MSs. Tissue distribution of MS-50 and MS-500 at 1 h after intravenous injection indicated that both MSs were exclusively distributed to liver and that small but significant amounts of MS-50 and MS-500 were also distributed to lung and spleen, respectively. To investigate the intrahepatic distribution of MS, liver was separated into liver parenchymal cells (PC) and non-parenchymal cells (NPC) at 1 or 6 h after intravenous administration. The contribution of each cell fraction was dependent on both the size of MS and the time after administration. Furthermore, by separating the NPC into endothelial cells and Kupffer cells using a centrifugal elutriation method, their contribution was also evaluated. For both MSs, Kupffer cells were recognized to be mostly responsible for the hepatic uptake, although a significant amount of MS-50 (about 28% of total uptake) was taken up by PC. On the other hand, there was little contribution of PC (about 5%) to the hepatic uptake of MS-500. The endothelial cells were contributed larger to the uptake of MS-500 (about 24%) than that of MS-50 (13%).

Animals↗

Structural and Chemical Analysis of Micro-sized Particles Found in Aluminous Electrical Porcelains.

: Uncommon, micro-sized particles with different morphologies were found in sintered aluminous electrical porcelains. The presence of these particles seems to be relatively insensitive to changes in composition of the porcelain system as well as in firing temperatures. X-ray energy-dispersive spectrometry (EDS) microanalysis showed that some particles, those with very well-defined geometries, were composed of K, Si, Al, and O with empirical formula KAlSi(2)O(6)-that is, leucite particles. Other particles showed less well-defined geometries, including some composed of Na, Si, Al, and O, corresponding to a sodium aluminum silicate structure, and others of K, Si, Na, Al, and O, corresponding to the leucite composition, where some K has been substituted for Na. The well-defined geometry particles were detected most often, and diffraction analysis with backscattering electrons showed that their unit cell was cubic, with unit cell parameter a = 1.343 nm. The formation of these particles may be the result of the relatively high concentration of K(2)O and/or Na(2)O in some very localized zones of the glassy phase due to weak coupling (e.g., alkali-enriched or -depleted melts) during diffusion at a slow cooling rate in the presence of catalytic agents such as TiO(2).

Journal Article↗

Concentration and particle size of airborne toxic algae (brevetoxin) derived from ocean red tide events.

Red tides in the Gulf of Mexico are formed by blooms of the dinoflagellate Karenia brevis, which produces brevetoxins (PbTx). Brevetoxins can be transferred from water to air in the wind-powered whitecapped waves during red tide episodes. Inhalation exposure to marine aerosol containing PbTx causes respiratory problems. A liquid chromatograph/ tandem mass spectrometric method was developed for the detection and quantitation of several PbTxs in ambient samples collected during red tide events. This method was complemented by a previously developed antibody assay that analyzes the entire class of PbTx compounds. The method showed good linearity, accuracy, and reproducibility, allowing quantitation of PbTx compounds in the 10 pg/m3 range. Air concentrations of PbTxs and brevenal for individual samples ranged from 0.01 to 80 ng/m3. The particle size showed a single mode with a mass median diameter between 6 and 10 microm, which was consistent for all of the PbTx species that were measured. Our results imply that individual PbTxs were from the same marine aerosol or from marine aerosol that was produced from the same process. The particle size indicated the likelihood of high deposition efficiency in the respiratory tract with the majority of aerosol deposited in the upper airways and small but not insignificant deposition in the lower airways.

Aerosols↗

Analysis of particle size and lipid composition as determinants of the metabolic clearance of human high density lipoproteins in a rabbit model.

Hypertriglyceridemia is commonly associated with triglyceride (TG) enrichment of high density lipoprotein (HDL) and reduction in HDL cholesterol and apolipoprotein A-I levels. We have recently reported that lipolytic modification of TG-rich HDL, which reduces particle size, enhances its clearance from the circulation. In the present study, we examined the role of particle size and lipid composition in determining the metabolic clearance of human HDL, in the absence of substantial in vivo modification of the particle by hepatic lipase. The rabbit, which has a very low hepatic lipase activity, was used for this purpose. Plasma fractions d < 1.21 g/ml were first isolated by ultracentrifugation from fasting humans with normal (NTG, n=6, mean plasma TG concentration=1.26+/-0.21 (SEM) mmol/l) or elevated plasma TG levels (HTG, n=5, TG=4.49+/-0.65 mmol/l). Small and large HDL particles were separated by gel filtration chromatography and were labeled with either 125I or (131)I. Large HDL were cleared more rapidly than small HDL in 10 out of 11 studies (P=0.006). There was, however, no difference in the fractional catabolic rate (FCR) of large HDL isolated from NTG versus from HTG subjects or in the FCR of small HDL from NTG versus HTG individuals. There was also no correlation between the TG content of HDL and its FCR. In summary, large, lipid-rich human high density lipoproteins (HDL) are cleared more rapidly than small human HDL in rabbits. These results, combined with our previous observation, also support the hypothesis that triglyceride enrichment of HDL, in the absence of substantial lipolytic modification, is not sufficient to enhance its clearance from the circulation.

Adult↗