PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polyurethanes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

The human macrophage response during differentiation and biodegradation on polycarbonate-based polyurethanes: dependence on hard segment chemistry.

Human monocytes, isolated from whole blood, were seeded onto tissue culture grade polystyrene (PS) and three polycarbonate-based polyurethanes (PCNUs) (synthesized with either 1,6-hexane diisocyanate (HDI) or 4,4'-methylene bis-phenyl diisocyanate (MDI), poly(1,6-hexyl 1,2-ethyl carbonate) diol (PCN) and 1,4-butanediol (BD) in different stoichiometric ratios (HDI:PCN:BD 4:3:1 or 3:2:1 and MDI:PCN:BD 3:2:1) (referred to as HDI431, HDI321 and MDI321, respectively). Following their differentiation to monocyte-derived macrophages (MDMs) the cells were trypsinized and reseeded onto each of the PCNUs synthesized with either 14C-HDI or 14C-BD and degradation was measured by radiolabel release (RR). When the differentiation surface was MDI321, there was more RR from 14C-HDI431 than from any other surface (p < 0.0001) whereas the amount of esterase (identified by immunoblotting) as well as the esterase activity was the greatest in MDM differentiated on PS, reseeded on 14C-HDI431 (p < 0.0001). The effect of potential degradation products (methylene dianiline (MDA) and BD) from the PCNUs was carried out to determine possible links between products and substrate-induced activation of MDM. MDA was found to inhibit RR 60% from MDM seeded on 14C-MDI321B (p < 0.0001), approximately 20% from 14C-HDI431 (p = 0.002) and no effect from 14C-HDI321B. MDA inhibited esterase activity 30% from MDM only on 14C-MDI321B (p = 0.003), but no effect on esterase activity was observed for the other two polymers. BD had no inhibitory effect on RR from any PCNU, but did inhibit esterase activity in MDM on 14C-HDI431 (p = 0.025). This study indicates that the degradation of a specific material is a multi-factorial process, dictated by its susceptibility to hydrolysis, the effect of specific products generated during this course of action, and perhaps not as well appreciated, the material's inherent ability to influence enzyme synthesis and release.

Absorbable Implants↗

Polyurethane films seeded with embryonic stem cell-derived cardiomyocytes for use in cardiac tissue engineering applications.

Cardiomyocytes are terminally differentiated cells and therefore unable to regenerate heart tissue after infarction. The successful engraftment of various cell types resulting in improved cardiac function has been reported, however methods for improving the delivery of donor cells to the infarct site still need to be developed. The use of bioengineered cardiac grafts has been suggested to replace infarcted myocardium and enhance cardiac function. In this study, we cultured embryonic stem (ES) cell-derived cardiomyocytes on thin polyurethane (PU) films. The films were coated with gelatin, laminin or collagen IV in order to encourage cell adhesion. Constructs were examined for 30 days after seeding. Cells cultured on laminin and collagen IV, exhibited preferential attachment, as assessed by cellular counts, and viability assays. These surfaces also resulted in a greater number of contracting films compared to controls. A degradable elastomer seeded with embryonic stem cell-derived cardiomyocytes may hold potential for the repair of damaged heart tissue.

Bioprosthesis↗

Understanding the biodegradation of polyurethanes: from classical implants to tissue engineering materials.

After almost half a century of use in the health field, polyurethanes (PUs) remain one of the most popular group of biomaterials applied for medical devices. Their popularity has been sustained as a direct result of their segmented block copolymeric character, which endows them with a wide range of versatility in terms of tailoring their physical properties, blood and tissue compatibility, and more recently their biodegradation character. While they became recognized in the 1970s and 1980s as the blood contacting material of choice in a wide range of cardiovascular devices their application in long-term implants fell under scrutiny with the failure of pacemaker leads and breast implant coatings containing PUs in the late 1980s. During the next decade PUs became extensively researched for their relative sensitivity to biodegradation and the desire to further understand the biological mechanisms for in vivo biodegradation. The advent of molecular biology into mainstream biomedical engineering permitted the probing of molecular pathways leading to the biodegradation of these materials. Knowledge gained throughout the 1990s has not only yielded novel PUs that contribute to the enhancement of biostability for in vivo long-term applications, but has also been translated to form a new class of bioresorbable materials with all the versatility of PUs in terms of physical properties but now with a more integrative nature in terms of biocompatibility. The current review will briefly survey the literature, which initially identified the problem of PU degradation in vivo and the subsequent studies that have led to the field's further understanding of the biological processes mediating the breakdown. An overview of research emerging on PUs sought for use in combination (drug + polymer) products and tissue regeneration applications will then be presented.

Absorbable Implants↗

Polyurethane biocidal polymeric surface modifiers.

Polyurethanes (PUs) with soft blocks containing semifluorinated (-CH2OCH2CF3) and 5,5-dimethylhydantoin pendant groups were prepared and employed (2 wt%) as biocidal polymeric surface modifiers (PSMs) for a conventional PU coating comprised of an isophorone diisocyanate/1,4-butanediol-derived hard block (50%) and poly(tetramethylene oxide) soft block. Surface enrichment of the PSM was verified by dynamic contact angle measurements. The PSM modified PU was activated by converting near-surface amide groups to chloramide with 3wt% hypochlorite. The conversion of near-surface amide to chloramide is reflected in somewhat increased hydrophobic character for the antimicrobial chloramide functionalized surfaces. Biocidal activity against both Gram-positive (Staphylococcus aureus) and Gram-negative (Pseudomonas aeruginosa, and Escherichia coli) bacteria was demonstrated by using a modified version of American Association of Textile Chemists and Colorists (AATCC-100) test. By changing the PSM concentration it was found that only 1.6 wt% PSM (0.66 wt% biocide, 5,5-dimethylhydantoin) in a conventional PU affected complete kill of P. aeruginosa in 15 min by using this biocidal testing protocol.

Anti-Infective Agents↗

Polyhedral oligomeric silsequioxane-polyurethane nanocomposite microvessels for an artificial capillary bed.

Fabricating artificial vascularised tissue would involve tissue-engineering techniques, but current technology limits this as cultured cells depend on growth media in vitro and on diffusion in vivo. Therefore, there is a need to construct a synthetic microvascular network, which would sustain these cultured cells in a similar manner to normal tissue. This is again hampered by the poor patency rates of current microvascular grafts. Based on our previous work on polyhedral oligomeric silsesquioxane-polyurethane nanocomposites, which have shown the unique ability to repel coagulant proteins whilst still allowing endothelialisation, we have now developed a new generation of microvascular prosthesis using this polymer. Using these dip-coated nanocomposite microvessels, we have shown that it is possible to mimic the hydraulic conductivity and pressure-responsive radial compliance characteristics of biological microvessels. This would allow nutrient exchange across its walls as well as minimise compliance mismatch throughout the physiological pressure range thus reducing intimal hyperplasia in the long term. This microvessel would have the following implications: (1) as a microvascular substitute to vein grafts and (2) in the future as a component of a microvascular network.

Biocompatible Materials↗

Chronic performance of polyurethane catheters covalently coated with ATH complex: a rabbit jugular vein model.

Covalent complexes of antithrombin (AT) and heparin (ATH) have superb anticoagulant activity towards thrombin and factor Xa. Stability of polyurethane central venous catheters covalently modified with radiolabeled ATH was studied using a roller pump with saline or protease P-5147. Saline wash removed loosely bound ATH molecules to decrease graft density from 26 to 12 pmol/cm2. However, only slightly more ATH was removed by strong protease (from 12 to 7 pmol/cm2). To evaluate ATH-coated, heparin-coated, and uncoated catheters, a chronic rabbit jugular vein model was developed with catheters maintained for up to 30-106 days. Lumen occlusion was tested by drawing blood twice daily. Although unmodified or heparin-coated catheters occluded within 5-7 days after insertion, all ATH catheters remained patent throughout the experiment. Scanning electron microscopy (SEM) analysis of heparin and uncoated catheters revealed extensive thrombosis (lumen+mural) while ATH catheters were unaffected. Visual observation showed significant deposition of protein and cells on control and heparin-modified catheters and, to a lesser degree, on ATH-coated surfaces. SEM showed no fibrin inside or outside of ATH catheters, which remained patent in extended studies out to 106 days. Although atomic force microscopy showed ATH coatings to be rough, 6-fold higher anti-factor Xa activity likely contributed to increased patency. Our data confirm that ATH-modified catheters are stable and have superior potency compared to heparin or control catheters.

Animals↗

Synthesis of two-component injectable polyurethanes for bone tissue engineering.

The advent of injectable polymer technologies has increased the prospect of developing novel, minimally invasive arthroscopic techniques to treat a wide variety of ailments. In this study, we have synthesised and evaluated a novel polyurethane-based injectable, in situ curable, polymer platform to determine its potential uses as a tissue engineered implant. Films of the polymers were prepared by reacting two pentaerythritol-based prepolymers, and characterised for mechanical and surface properties, and cytocompatibility. This polymer platform displayed mechanical strength and elasticity superior to many injectable bone cements and grafts. Cytotoxicity tests using primary human osteoblasts, revealed positive cell viability and increased proliferation over a period of 7 days in culture. This favourable cell environment was attributed to the hydrophilic nature of the films, as assessed by dynamic contact angle (DCA) analysis of the sample surfaces. The incorporation of beta-TCP was shown to improve mechanical properties, surface wettability, and cell viability and proliferation, compared to the other sample types. SEM/EDX analysis of these surfaces also revealed physicochemical surface heterogeneity in the presence of beta-TCP. Based on preliminary mechanical analysis and cytotoxicity results, these injectable polymers may have a number or potential orthopaedic applications; ranging from bone glues to scaffolds for bone regeneration.

Aged↗

Rhodococcus sp. F92 immobilized on polyurethane foam shows ability to degrade various petroleum products.

This work reports on the immobilization and performance of a hydrocarbon-degrading microorganism on polyurethane foam (PUF) in the bioremediation of petroleum hydrocarbons. The ability of four different microorganisms to immobilize on PUF and to degrade various petroleum products (Arabian light crude (ALC), Al-Shaheen crude (ASC), diesel and oil slops) was assessed by measuring the n-alkane fraction remaining in the petroleum products over time. A Rhodococcus sp. (designated as F92) had the highest number of immobilized viable cells (10(9) cells per cm3 PUF) and a maximum attachment efficiency of 90% on PUF of a density of 14 kg/m3. Scanning electron microscopy showed the presence of extracellular structures that could play an important role in the immobilization of F92 on PUF. Analysis by GC-MS revealed that both free and immobilized F92 cells were able to degrade approximately 90% of the total n-alkanes in the petroleum products tested within 1 week at 30 degrees C. Rhodococcus sp. F92 was efficiently immobilized onto PUF and the immobilized cells were able to degrade a variety of petroleum products such as ALC, ASC, diesel and oil slops. The results suggest the potential of using PUF-immobilized Rhodococcus sp. F92 to bioremediate petroleum hydrocarbons in an open marine environment.

Alkanes↗

Polyurethane vascular catheter surface grafted with zwitterionic sulfobetaine monomer activated by ozone.

Polyurethane (PU) is a conventional biomedical material with favorable biocompatibility and excellent mechanical properties and widely used in making vascular catheter, but its antithrombogenic property is not good enough to make it as a more demanding applicable biomaterial. Surface modification is an effective way to improve the hemocompatibility for biomaterials. The purpose of present study was to use ozonization method to modify the surface of PU vascular catheter slice to improve its antithrombogenicity by grafting N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl) ammonium (DMMSA), a zwitterionic sulfobetaine monomer. PU vascular catheter (PUVC) grafted with DMMSA (PUVC-g-PDMMSA) was characterized by ATR-FTIR and XPS. ATR-FTIR and XPS investigation confirmed the graft polymerization. The blood compatibility of the grafted films was evaluated by platelet rich plasma (PRP) platelet adhesion study and scanning electron microscopy (SEM) was used to observe the morphology of platelet using PU vascular catheter (PUVC) as the reference. No platelet adhesion was observed for the grafted PUVC slice incubated with PRP at 37 degrees C for 120 min. It is significant that this new zwitterionic sulfobetaine grafted PUVC have improved antithrobogenicity. It is effective that the inner surface of vascular catheter with inner diameter in only 3mm can be grafted with PDMMSA by using ozonization method.

Betaine↗

Platelet adhesive resistance of polyurethane surface grafted with zwitterions of sulfobetaine.

A possible approach to improve the blood compatibility of poly(etherurethane)s (PU) involves the covalent attachment of key molecular on its surface. Recently, polymer tailed with zwitterions was found having good blood compatibility. The purpose of present study was to design and synthesis a novel nonthrombogenic biomaterial by modifying the surface of poly(etherurethane) with zwitterions of sulfobetaine via HDI spacer. The films of polyurethane were grafted with sulfobetaine by a three-step procedure. In the first step, the film surfaces were treated with hexamethylene diisocyanate (HDI) in toluene at 50 degrees C in the presence of di-n-butyl tin dilaurate(DBTDL) as a catalyst. The extent of the reaction was measured by ATR-IR spectra; a maximum number of free NCO group was obtained after a reaction time of 2.5 h. In the second step, the primary amine group of N,N-diethylethylenediamine (DEA) or N,N-dimethylethylenediamine (DMA) was allowed to react in toluene with isocyanate groups bound on surface. In the third step, two kinds of sulfobetaines were formed in the surface through the ring-opening reaction between tertiary amine of DMA or DEA and 1,3- propanesultone (PS). The reaction process was monitored with ATR-IR spectra and XPS spectra. The wettability of films was investigated by water contact angle measurement. A platelet adhesion experiment was conducted as a preliminary test to confirm the improved blood compatibility of PU. The number of platelets adhering to PU decreased greatly compared to original after 1 h and 3 h of contact with human plate-rich plasma.

Betaine↗

The influence of polyelectrolyte charges of polyurethane membrane surface on the growth of human endothelial cells.

A novel technique to introduce free amino groups onto polyester scaffolds via aminolyzing the ester groups with diamine has been developed recently. The introduction of the free amino groups on these polyester surfaces provides us the possibility to modify polymer surface in a simpler manner, e.g. layer-by-layer assembly of charged species. By this technique, many negatively and positively charged biopolymers were deposited alternatively on polyurethane surface. The deposition process was monitored by fluorescence spectroscopy and advancing contact angle measurements. The result of human endothelial cells cultured in vitro showed that cells on negatively charged surface could not spread and flatten well due to the electrostatic repulsion. The lower attachment ratio induced the lower proliferation ratio. However, after the surface charge was inversed by collagen, both attachment and proliferation ratios increased to different extent. Observed under SEM, cells also presented a flat and spreading morphology.

Animals↗

Protein resistant polyurethane surfaces by chemical grafting of PEO: amino-terminated PEO as grafting reagent.

The objective of this work was to gain a better understanding of the mechanism of resistance to protein adsorption of surfaces grafted with poly(ethylene oxide) (PEO). A polyurethane-urea was used as a substrate to which PEO was grafted. Grafting was carried out by introducing isocyanate groups into the surface followed by reaction with amino-terminated PEO. Surfaces grafted with PEO of various chain lengths (PUU-NPEO) were prepared and characterized by water contact angle and X-ray photoelectron spectroscopy (XPS). XPS data indicated higher graft densities on the PUU-NPEO surfaces than on analogous surfaces prepared using hydroxy-PEO (PUU-OPEO) as reported previously [J.G. Archambault, J.L. Brash, Colloids Surf. B: Biointerf. 33 (2004) 111-120]. Protein adsorption experiments using radiolabeled myoglobin, concanavalin A, albumin, fibrinogen and ferritin as single proteins in buffer showed that adsorption was reduced on the PEO-grafted surfaces by up to 95% compared to the control. Adsorption decreased with increasing PEO chain length and reached a minimum at a PEO MW of 2000. Adsorption levels on surfaces with 5000 and 2000 MW grafts were similar. There was no clear effect of protein size on resistance to protein adsorption. Adsorption on the PUU-NPEO surfaces was significantly lower than on the corresponding PUU-OPEO surfaces, again suggesting higher graft densities on the former. Adsorption of fibrinogen from plasma was also greatly reduced on the grafted surfaces. From analysis (SDS-PAGE, immunoblotting) of the proteins eluted after plasma exposure, it was found that the grafted surfaces and the unmodified substrate adsorbed the same proteins in roughly the same proportions, suggesting that adsorption to the PEO surfaces occurs on patches of bare substrate. The PEO grafts did not apparently cause differential access to the substrate based on protein size.

Adsorption↗

Chemical graft polymerization of sulfobetaine monomer on polyurethane surface for reduction in platelet adhesion.

Surface modification is an effective way to improve the hemocompatibility and remain bulk properties of biomaterials. Recently, polymer tailored with zwitterions was found having good blood compatibility. In this study, the zwitterionic monomer of sulfobetaine was graft polymerized onto polyurethane (PU) surface in a three-step heterogenous system through the vinyl bonds of acrylic acid (AA) or hydroxyethyl methacrylate (HEMA), which was immobilized with hexamethylene diisocyanate (HDI) beforehand. First, PU was activated with isocyanate groups using HDI as coupling agent. Second, AA or HEMA was introduced through reaction of AA or HEMA with NCO groups bonded on PU surface. Last, zwitterionic monomer of sulfobetain was graft polymerized with vinyl group of AA or HEMA using AIBN as polymerization initiator. The reaction process was monitored with ATR-IR spectra and XPS spectra. Variation of graft yield with temperature and monomer feed concentration was investigated and feasible conditions were optimized. The wettability of films was investigated by water contact angle measurement and water absorbance. Platelet adhesion experiment was conducted as a preliminary test to confirm the improved blood compatibility of PU. The number of platelets adhering to PU decreased greatly comparing with the originals after 1 and 3 h of contact with human plate-rich plasma (PRP).

Acrylates↗

Blood compatibility of thermoplastic polyurethane membrane immobilized with water-soluble chitosan/dextran sulfate.

Water-soluble chitosan (WSC)/dextran sulfate (DS) was immobilized onto the surface of thermoplastic polyurethane (TPU) membrane after ozone-induced graft polymerization of poly(acrylic acid) (PAA). The surface was characterized with contact angle measurement and X-ray photoelectron spectroscopy (XPS). The adsorption of human plasma fibrinogen (HPF) followed the Langmuir adsorption isotherm. The results showed that the surface density of peroxides generated and poly(acrylic acid) (PAA) grafted reached the maximum value at 20 min of ozone treatment. It was found that the WSC- and DS-immobilized amount increased with pH and the molecular weight of WSC. The membrane/water interfacial free energy increased with PAA-grafting and WSC/DS-immobilization, indicating the increasing wettability of TPU membrane. The adsorption of HPF on TPU-WSC/DS membranes could be effectively curtailed and exhibited unfavorable adsorption. Moreover, WSC/DS immobilization could effectively reduce platelet adhesion and prolong the blood coagulation time, thereby membrane improving blood compatibility of TPU membrane. In addition, the in vitro cytotoxicity test of PEC modification was non-cytotoxic according to much low growth inhibition of L929 fibroblasts. Furthermore, TPU-WSC/DS membranes exhibited higher cell viability than native TPU membrane.

Acrylic Resins↗

Antimicrobial activity of polyurethanes coated with antibiotics: a new approach to the realization of medical devices exempt from microbial colonization.

Intravascular devices are widely used for vascular access but are associated with substantial risk of development of devices-related bloodstream infection (DR-BSI), which causes a considerable increase of morbidity and mortality, prolonged hospitalisation and growing medical costs. Since conventional treatment of DR-BSI fails in a significant number of cases, resulting in removal of the device, new approaches are needed to prevent bacterial colonization. In this paper, two antibiotics, rifampin and amoxicillin, have been adsorbed on polyurethanes exhibiting acidic or basic properties. The influence of the type of antibiotic-polymer interaction on the amount of adsorbed antibiotic and on the release kinetics was studied. It was seen that the antibiotic-polymer affinity increases both with the introduction in the polymer side-chain of functional groups and with the matrix hydrophilicity. The antimicrobial activity of the treated polymers, evaluated in vitro by the Kirby-Bauer test, depends on the amount of antibiotic adsorbed, on the strength of drug-matrix interaction and on the water swelling of the polymers. The inhibition zone of bacterial growth lasts only a few hours for the amoxi-coated polymers while remains at least for five months for the rifampin-coated ones. The presence of serum proteins decreases by about 30% the inhibition zone diameter of these latest matrices after two months.

Adsorption↗

Cyclic strain increases fibroblast proliferation, matrix accumulation, and elastic modulus of fibroblast-seeded polyurethane constructs.

Rapid induction of matrix production and mechanical strengthening is essential to the development of bio-artificial constructs for repair and replacement of load-bearing connective tissues. Toward this end, we describe the development of a mechanical bioreactor and its application to investigate the influence of cyclic strain on fibroblast proliferation, matrix accumulation, and the mechanical properties of fibroblast-seeded polyurethane constructs (FSPC). Human fibroblasts were cultured in 10% serum-containing conditions within three-dimensional, porous elastomeric substrates under static conditions and a model regime of cyclic strain (10% strain, 0.25 Hz, 8 h/day), with and without ascorbic acid supplementation. After one week, the combination of cyclic strain and ascorbic acid resulted in significantly increased construct elastic modulus (>110%) relative to either condition alone. In contrast, cyclic strain alone was sufficient to stimulate significant increases in fibroblast proliferation. Mechanical strengthening of FSPCs was accompanied by increased type I collagen and fibronectin matrix accumulation and distribution, and significantly increased gene expression for type I collagen, TGFbeta-1, and CTGF. These results suggest that strain-induced conditioning in vitro leads to mechanical strengthening of fibroblast/material constructs, most likely resulting from increased collagen matrix deposition, secondary to strain-induced increases in cytokine production.

Ascorbic Acid↗

Distribution of phenanthrene between soil and an aqueous phase in the presence of anionic micelle-like amphiphilic polyurethane particles.

Sorption of micelle-like amphiphilic polyurethane (APU) particles to soil was studied and compared to that of a model anionic surfactant, sodium dodecyl sulfate (SDS). Three types of APU particles with different hydrophobicity were synthesized from urethane acrylate anionomers (UAA) and used in this study. Due to the chemically cross-linked structure, APU exhibited less sorption to the soil than SDS and a greater reduction in the sorption of phenanthrene, a model soil contaminant, to the soil was observed in the presence of APU than SDS even though the solubility of phenanthrene was higher in the presence of SDS than APU. A mathematical model was developed to describe the phenanthrene distribution between soil and an aqueous phase containing APU particles. The sorption of phenanthrene to the test soil could be well described by Linear isotherm. APU sorption to the soil was successfully described by Langmuir and Freundlich isotherms. The partition of phenanthrene between water and APU were successfully explained with a single partition coefficient. The model, which accounts for the limited solubilization of phenanthrene in sorbed APU particles, successfully described the experimental data for the distribution of phenanthrene between the soil and the aqueous phase in the presence of APU.

Adsorption↗

Comparison of amphiphilic polyurethane nanoparticles to nonionic surfactants for flushing phenanthrene from soil.

Amphiphilic polyurethane (APU) nanoparticles were synthesized through crosslinking polymerization of nano-aggregates of urethane acrylate nonionomer (UAN). The efficiency of in situ extraction of sorbed phenanthrene from aquifer material was tested using soil columns and compared with that of surfactants such as Triton X-100, Brij 30, and Tween 80. The extraction efficiency of those washing materials strongly depended on their concentration, flow rate, and the degree of sorption within soil column. That is, the extraction efficiency increased with the decrease of flow rate and the degree of sorption and the increase of the concentration. Even though the surfactants are superior to APU nanoparticles at solubilizing phenanthrene, at the same flow rate (0.02 mL/min) and concentration (4000 mg/L), the effectiveness of in situ soil washing of APU nanoparticles was about two times higher than those of surfactants. This is because, at the lower flow rates, the degree of sorption of APU nanoparticles was lower than that of surfactants, owing to the chemically crosslinked nature of APU nanoparticles.

Adsorption↗