PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Aortic Dissection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Comparison of a percutaneous separate stent endograft and a conventional thoracic stent-graft for endovascular repair of type B aortic dissection.

PURPOSE: To compare the immediate and midterm outcomes of aortic dissection repair with a separate stent endograft (SSE) versus a conventionally constructed thoracic stent-graft. METHODS: The records of 35 patients treated for type B aortic dissection from September 1997 to April 2003 were reviewed. Seventeen patients (12 men; mean age 58.8+/-11.6 years) underwent endovascular repair with a separate stent endograft (SSE), a custom-made device with a reduced profile suitable for percutaneous introduction through a 12-F sheath. Eighteen patients (10 men; mean age 56.1+/-12.8 years) underwent treatment with a conventional custom-made stent-graft. RESULTS: Angiographic success was achieved in 13/17 (76.5%) of the SSE-treated patients and 12/18 (66.7%) for the conventional device group (p=0.521). Clinical success (complete obliteration/thrombosis of the false lumen) was achieved in 12/17 (70.6%) and 11/18 (61.1%), respectively (p=0.555). There were 2 cases of stent-graft movement during deployment and 2 access site complications in the conventional stent-graft group, whereas the SSE patients had no complications. Except for 2 conventional stent-graft patients who were lost to follow-up, all patients are alive at a mean 19.5+/-11.6 months for the SSE group and 34.2+/-21.5 months for the conventional stent-graft patients. CONCLUSIONS: The separate stent endograft can be deployed percutaneously without the need for blood pressure reduction, achieving accurate deployment without migration. In this small clinical experience, patients treated with the SSE had no access site complications and demonstrated midterm results comparable to the conventional stent-graft cohort, suggesting the possible usefulness of this device for the treatment of thoracic aortic dissection.

Adult↗

Magnetic resonance velocity mapping in aortic dissection.

We describe three patients with chronic aortic dissection in whom both spin-echo magnetic resonance imaging (MRI) and cine field-echo imaging were performed. The field even-echo rephasing (FEER) sequence showed the intimal flaps much more clearly than the spin-echo sequence and provided a distinction between thrombus and static blood. Velocity mapping allowed flow measurements in the true and false lumens. The management of the three patients was based upon the information provided by MRI. It is suggested that MRI may avoid invasive investigation and be the method of choice in haemodynamically stable patients with aortic dissection provided that the FEER sequence is used.

Aged↗

[Emergent operation for acute Stanford type A aortic dissection].

Results of emergent surgery for acute Stanford type A aortic dissection are still poor. We reviewed our cases to find out how we could ameliorate surgical results. In the past five years, 36 patients with type A aortic dissection underwent emergent surgery. The operation was started within six hours from the onset of symptoms in 16 patients. The extent of aortic replacement was just beyond the entry-bearing portion. The operation was performed with the aid of open distal anastomosis and selective cerebral perfusion. Operative death occurred in one patient. Postoperative complications developed frequently. Respiratory failure, renal dysfunction and low cardiac output syndrome were most frequent. Their co-risk factor was perioperative bleeding which was related to young age, long operation time, arch replacement, additional procedure and failure of the entry site resection. Some modification of the suturing method might reduce hemorrhage. Prompt surgery following the diagnosis and appropriate selection of surgical tactics and anastomosis technique in order to reduce bleeding is essential to improve surgical results of acute type A aortic dissection.

Acute Disease↗

Type B aortic dissection and thoracoabdominal aneurysm formation after endoluminal stent repair of abdominal aortic aneurysm.

Endoluminal stent graft repair of abdominal and thoracic aortic aneurysms is being performed in increasing numbers. The long-term benefits of this technology remain to be seen. Reports have begun to appear regarding complications of stent graft application, such as renal failure, intestinal infarction, distal embolization, and rupture. Many of these complications have been associated with a fatal outcome. We describe a case of acute, retrograde, type B aortic dissection after application of an endoluminal stent graft for an asymptomatic infrarenal abdominal aortic aneurysm. An extent I thoracoabdominal aortic aneurysm subsequently developed and was successfully repaired. Aggressive evaluation of new back pain after such a procedure is warranted. Further analysis of the short-term complications and long-term outcome of this new technology is indicated before universal application can be recommended.

Aged↗

[Dissecting aortic aneurysm of DeBakey type II diagnosed by color Doppler flow imaging and treated by a Bentall surgical procedure: a case report].

A 33-year-old man with known annuloaortic ectasia was admitted to the hospital because of chest pain. A dissecting aortic aneurysm was strongly suspected, but angiography was not performed because of his history of allergic reaction to iodine contrast material. Two-dimensional echocardiography demonstrated a markedly dilated basal aorta. The aortic wall immediately above the right sinus of Valsalva appeared to divide the aortic lumen into anterior and posterior channels. A defect in the intimal flap with a diameter of two cm was also detected six cm above the aortic ring. Color Doppler flow mapping showed blood flow passing through a probable entrance tear from the true lumen into the false lumen. Reentry could not be detected by Doppler imaging. All major aortic tributaries were presumed patent and supplied via the true lumen. The patient underwent successful emergency Bentall surgical procedure and recovered. It is emphasized that in some cases of DeBakey type I or II aortic dissection, color Doppler flow imaging is helpful for determining indications for emergency surgery.

Adult↗

[Transesophageal echocardiography in the diagnosis of aortic dissection].

INTRODUCTION AND OBJECTIVE: Eighty-two patients with suspected aortic dissection were studied to assess the usefulness of transesophageal echocardiography in the diagnosis of this entity. METHODS: All patients underwent transesophageal echocardiogram. The diagnosis of aortic dissection was established in 46 patients by other diagnostic procedures including angiography and computed tomography, surgery and necropsy. RESULTS: The sensitivity and specificity of transesophageal echocardiography were 98% and 97%, respectively. By computed tomography, sensitivity was 92% and specificity 88%. By angiography, sensitivity and specificity were 97% and 93%, respectively. In the diagnosis of the dissection type, transesophageal echocardiography classified correctly in 98%, computed tomography in 89% and angiography 97% of cases. Transesophageal echocardiography visualized the tear in 82% of cases, and angiography in 53%. CONCLUSIONS: Transesophageal echocardiography provides rapid, accurate diagnosis of aortic dissection and permits the initiation of appropriate treatment. Angiography is indicated in non-conclusive cases or those which supra-aortic involvement clinically suspected.

Acute Disease↗

[Prognosis of postoperative aortic dissection. Assessment with magnetic resonance].

OBJECTIVE: To evaluate operated type A aortic dissection by Magnetic Resonance Imaging (MRI), in order to detect long-term complications and identify prognostic indexes of evolution. DESIGN: Prospective study with a three-year period of follow-up. Prognosis evaluation. SETTINGS: Outpatient Clinic at Hospital de Santa Maria and Magnetic Resonance Imaging Center at Hospital da Cruz Vermelha. PATIENTS: A sample of 37 patients submitted to type A aortic dissection surgery, included sequentially, after exclusion of those with contraindication to MRI. METHODS: Initial evaluation (clinical and MRI study) at 3 to 4 months and at 1, 2 and 3 years after surgery. The mean follow-up time was 39.3 +/- 2.9 months. We evaluated the following complications over the aorta (aortic graft and five segments of residual aorta) and the aortic valve: aneurysm, pseudoaneurysm, rupture, re-dissection, progressive aortic valve regurgitation, reoperation and death. The prognostic indexes analysed were: presence of residual flap; false lumen patency; presence of re-entry points; false lumen to aorta dimension ratio; initial aortic dimension; increase of aortic dimension. RESULTS: All patients, with the exception of three that died, remained asymptomatic. COMPLICATIONS: Aneurysm was detected in 45.9% of patients, located in one or more segments; rupture occurred in three patients, preceded by aneurysm and pseudoaneurysm development; moderate or severe aortic regurgitation was detected in 47.8% of patients. Prognostic indexes: 1. Aneurysm development in each segment yeilded a significant association with: presence of residual flap in the same and other segments; higher initial dimension of the same and other segments, with the exception of the abdominal segment; higher increase in dimension of the same and other segments, with the exception of the abdominal segment; 2. Moderate or severe aortic regurgitation development showed a tendency to association with higher increase in dimension of proximal ascending aorta. 3. No association was found between aneurysm and aortic regurgitation development. CONCLUSIONS: Patients operated for type A aortic dissection had a high incidence of late complications which lead to reoperation and in some cases death. The presence of a residual flap, increased aortic dimensions and higher increase rate of aortic dimensions were associated with a complicated evolution. MRI was a very useful technique for long-term monitoring and to identify prognostic indexes of evolution.

Aortic Dissection↗

Significance of distal fenestration in graft replacement for chronic aortic dissection.

It is recently controversial whether distal fenestration is necessary in graft replacement for chronic aortic dissection. Several groups started to try the exclusion of intimal entry by the insertion of a stent-graft as a treatment for chronic aortic dissection, while conventional surgical techniques consisted of graft replacement with distal anastomosis to both the true and false channels. It should be kept in mind that the resultant occlusion of the false lumen after obliteration of the false channel could promote spinal cord ischemia. We report a patient with delayed paraplegia after graft replacement without distal fenestration for chronic type B aortic dissection. It is possible that not all cases of chronic aortic dissection are good for stent-grafting.

Aortic Dissection↗

Chronic beta-blocker therapy improves outcome and reduces treatment costs in chronic type B aortic dissection.

OBJECTIVES: To compare the medical treatment of chronic type B aortic dissection with beta-blockers versus other antihypertensive treatments in terms of their requirement for surgical intervention and treatment costs. METHODS: Case records of the 130 patients treated for aortic dissection type B in this unit between 1988 and 1997 were reviewed. Seventy-eight of 130 patients with chronic dissection have received isolated medical treatment. Seventy-one of 78 patients were discharged alive. Fifty-one of 71 received beta-blocker treatment, 20/71 were treated with other antihypertensive drugs. RESULTS: Surgery for aortic dissection became necessary in 20/71 patients (28%) during follow-up (mean, 4.2 years): 10/51 in the beta-blocker group and 9/20 in the other antihypertensive drug group. The freedom from subsequent aortic operation was 80 and 47%, respectively (P=0.001). Indications for emergency surgery were increased aortic diameter (79%), symptomatic aortic aneurysm (11%), and renal artery hypoperfusion (5%). The median hospitalization time during follow-up (dissection-related) was 2 days for patients who received beta-blockers and 16 days for patients who received other antihypertensive drug treatments (P=0.001). The cost of treatment/patient per year amounted to 644 and 12748 euros, respectively. CONCLUSIONS: A substantial proportion of patients with chronic type B dissection who receive initial medical management will later need surgery. Long-term treatment with beta-blockers reduces the progression of aortic dilatation, the incidence of subsequent hospital admissions, as well as the incidence of late dissection-related aortic procedures and the cost of treatment. Patients with chronic type B dissection need, in addition to frequent follow-up of aortic diameter, continuous treatment with beta-blocking agents.

Adrenergic beta-Antagonists↗

Newly diagnosed acute aortic dissection: characteristics, treatment modifications, and outcomes.

The objective of the present study was to examine cases of acute aortic dissection in order to analyze the clinical and diagnostic findings, and to summarize their treatment modalities, as well as their hospital outcomes. Between July 1998 and June 1999, we prospectively studied patients who were newly diagnosed as having acute aortic dissection at 25 hospitals in Mie prefecture. These cases were examined for their demographics, the characteristics of the clinical findings, diagnostic methods, treatment modalities according to the type of aortic dissection, and the early morbidity and mortality of the hospital outcomes. Of 66 newly diagnosed aortic dissections (43 males), 30 were type A and 36 were type B. Seventy-six percent of the cases arrived at a medical facility within 6 hours from the onset of symptoms. Frequent initial symptoms and clinical findings were pain in 95.5%, cardiac arrest and/or hypotension in 21%, pericardial effusion in 29%, pleural effusion in 25%, and neurological signs in 30%. Twenty-one patients underwent surgical repair, 36 were treated medically, and 5 underwent endovascular stenting. Overall early mortality was 12.1%, which included 2 DOA. Fifty percent of these deaths occurred within 48 hours, and 63% by 72 hours of the initial event. In spite of the relatively rare incidence of acute aortic dissection in our study, the calculated incidence was 4.0/100,000/year. The overall mortality rate was relatively low compared to the figures reported in the literature, suggesting the earliest possible diagnosis and timely intervention are critically important to attain successful outcomes.

Acute Disease↗

Transmural necrosis of the esophagus secondary to acute aortic dissection.

A case of transmural ischemic necrosis of the esophagus secondary to aortic dissection is presented. A 66-year-old woman with acute type A aortic dissection underwent total arch replacement with a technique of deep hypothermic arrest and retrograde cerebral perfusion. Postoperatively she had hematemesis, and endoscopic examination revealed circumferential mucosal necrosis and desquamation of the lower esophagus. She died of multiple organ failure on postoperative day 74. Autopsy demonstrated transmural necrosis of the esophagus secondary to ischemia. Ischemia of the esophagus secondary to aortic dissection is extremely rare.

Acute Disease↗

Pitfalls in the echocardiographic diagnosis of aortic dissection.

The authors studied 25 patients with transthoracic echocardiography (TTE) and/or transesophageal echocardiography (TEE) for suspected aortic dissection. Of these, aortic dissection was diagnosed correctly in 19 patients, but in 6 the echocardiographic findings for dissection were atypical or false-positive. In patient 1, the TEE revealed a dilatated proximal aortic root. TEE showed a possible flap but was nondiagnostic. The diagnosis was made by computed tomography (CT) and confirmed at surgery to be type 1 dissection. In patient 2, the TTE depicted flail aortic cusps, questionable vegetations, and dilatated aortic root. In patient 3, TTE demonstrated moderate pericardial effusion with hematoma but no dissection. Type 1 dissection was subsequently confirmed at autopsy in both. Patient 4 had TEE diagnosis of type 3 dissection. However, reevaluation of the study by a senior sonographer just prior to surgery led to the correct diagnosis of type 1 dissection. Patients 5 and 6 had dilatated ascending aortas with linear echoes within the lumen on TEE and were reported as having type 1 dissections. CT and/or angiography did not reveal dissection in either patient. In conclusion, TTE and TEE are vaulable tests in diagnosing aortic dissection. However, atypical features, misdiagnosis of the site of dissection, or false-positive studies can occur.

Adult↗

[Clinical case of the month. Complete replacement of the ascending aorta and aortic arch in a case of chronic aortic dissection].

We report the case of a patient who developed an evolutive chronic aortic dissection after ascending aorta replacement for acute type A aortic dissection. Owing to the development of severe aortic regurgitation, aortic root pseudoaneurysm and aneurysmal dilatation of the arch and descending aorta, reoperation was adviced. Reoperation included Cabrol modification of the Bentall operation and aortic arch replacement with elephant trunk performed under deep hypothermic circulatory arrest. The incidence of late aneurysmal formation in type 1 aortic dissection has been reported to be 30%. Close postoperative follow-up of the aortic diameter is necessary to detect a critical dilatation and to permit elective reoperation.

Aortic Dissection↗

Electrocardiographic abnormalities in patients with acute aortic dissection.

In conclusion, acute electrocardiographic changes were not uncommon in patients with acute aortic dissection. It was suggested that acute electrocardiographic changes in aortic dissection resulted from at least 1 of the following 3 mechanisms: (1) involvement of the ostium of the coronary artery; (2) shock state, especially tamponade; and (3) preexisting coronary artery disease. We believe that physicians should be aware of the possibility of acute aortic dissection not only in patients with chest pain with a normal electrocardiogram, but also in those with electrocardiographic changes.

Acute Disease↗

Immunoscintigraphy of aortic dissection with 99mTc-labeled murine anti-smooth muscle myosin monoclonal antibody in rats.

UNLABELLED: Aortic dissection is among the most common of fatal conditions of the aorta. Prompt and accurate diagnosis of the site and extent of the lesion is necessary for adequate therapy. However, this catastrophic disease, characterized by extensive damage to smooth muscle cells, lacks specific signs and symptoms. As a result, the diagnosis is still frequently missed today and a new diagnostic method to specifically identify aortic dissection would be attractive. The purpose of this study was to examine the feasibility of radioimmunoscintigraphy using 99mTc-anti-smooth muscle myosin monoclonal antibody (SM-MAb) for the noninvasive diagnosis of aortic dissection in the rat experimental model. METHODS: The accumulation of 99mTc-anti-SM-MAb was studied, and scintigraphic imaging with 99mTc-anti-SMMAb was performed in rats immediately after experimental aortic dissection and 1 and 2 wk later. RESULTS: The radioactivity of 99mTc-anti-SM-MAb in the dissected aorta showed a significant increase compared both with the normal portion of the aorta and with blood 6 h after injection of the radiotracer; the ratio of the percentage injected dose per gram (%lD/g) in the lesion to that retained in the normal portion was 4.17 +/- 1.47. Scintigraphic imaging with 99mTc-anti-SM-MAb allowed distinct visualization of the dissected aorta with specific accumulation of antibody 6 h after tracer injection. Selective accumulation of the tracer in the dissected portion of the aorta persisted even 1 wk after aortic injury, allowing clear visualization of the dissected lesion by scintigraphy. CONCLUSION: Radioimmunoscintigraphy using anti-SM-MAb is a potentially useful noninvasive diagnostic method for imaging aortic dissection.

Aortic Dissection↗

Cannulation of the right axillary artery for surgery of acute type A aortic dissection.

OBJECTIVE: The optimal choice of the arterial inflow site during operations for type A aortic dissection is not clearly defined. The aim of the prospective study was to identify whether cannulation of the right axillary artery instead of the femoral artery may improve the results of surgery for acute type A aortic dissection. METHODS: Seventy consecutive patients were operated on because of acute type A aortic dissection from January 2000 to February 2002. The only difference in surgical strategy was the site of arterial cannulation: the right axillary artery was used in 20 patients [axillary group] and the left femoral artery in 50 patients [femoral group]. All patients had aortic surgery with open distal anastomosis during deep hypothermic arrest and retrograde cerebral perfusion. The mean age was 58.7 +/- 12 years with a range from 28 to 88 years (axillary group, 56.6 +/- 13 years; femoral group, 59.4 +/- 12 years; P = 0.435). Preoperatively evident organ malperfusion was identified in five (25%) patients of the axillary group and in seven (14%) of the femoral group. RESULTS: There was no perioperative death. The hospital mortality rate was 5.0% for the axillary group and 22% for the femoral group (all patients, 17%). Major neurological complications occurred postoperatively in 5% of patients from the axillary group (one out of 20 patients) and in 8% of patients from the femoral group (four out of 50 patients) (all patients, 7%). CONCLUSION: Cannulation of the right axillary artery improved the outcome of surgery for acute type A aortic dissection. However, postoperative complications occurred after both axillary and femoral artery cannulation.

Acute Disease↗

[Circular dissection of the ascending aorta with intimo-intimal invagination. CT diagnosis of a rare form of aortic dissection].

Intimointimal intussusception is a rare type of aortic dissection. The intimal tear occurs circumferentially with intussusception of the intimal flap downstream into the aortic arch causing obstruction of the great supraaortic vessels. A CT diagnosis has only once been reported. CT and angiographic findings of this rare complication of aortic dissection are described.

Aortic Dissection↗