PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Application”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Fast blue and diamidino yellow as retrograde tracers in peripheral nerves: efficacy of combined nerve injection and capsule application to transected nerves in the adult rat.

Capsule application of Diamidino Yellow (DY) to the cut end of the sciatic nerve immediately followed by capsule application of Fast Blue (FB) resulted in approximately 95% double-labelled dorsal root ganglion neurones (DRGn) and motoneurones (Mn). Nerve injection of DY followed either immediately or 2 months later by capsule application of FB resulted in approximately 90% double-labelled DRGn and Mn, indicating that DY and FB label similar populations of DRGn and Mn, and that insignificant DY fading occurred during this period. Inversing the order of application, however, i.e. nerve injection of FB followed immediately by capsule application of DY, resulted in double labelling in only approximately 10% of the DRGn and Mn. These percentages increased to 70% of the DRGn and 60% of the Mn when the FB injection was followed 1 or 2 months after by the DY application, indicating that DY uptake is blocked by recent administration of FB. The results indicate that DY and FB might be useful for sequential labelling before and after nerve injury as a tool to investigate the accuracy of sensory and motor regeneration.

Amidines↗

Povidone iodine gel alcohol: a 30-second, onetime application preoperative skin preparation.

BACKGROUND: Simplifying and shortening the skin-preparation application procedure is desirable for many reasons, which include labor-cost savings and improved suite utilization. A new formulation, PVP-I Gel Alcohol (PGA) that contains 5% PVP-I and 62% ethanol in gel form, was developed to achieve a shorter preparation time with a rapid and persistent efficacy on a broad spectrum of microorganisms and to minimize the potential for iodine irritation. METHOD: The test methods outlined in the Federal Register, 21 CFR Parts 333 and 369, "Tentative Final Monograph for Health-Care Antiseptic Drug Products;" Proposed Rule, 1994 (Monograph), were adapted in this study. Efficacy of PGA was evaluated, both in vitro and in vivo. The in vitro time-kill and minimum inhibition concentration tests were conducted by using 33 strains of aerobic and anaerobic gram-positive bacteria, gram-negative bacteria, yeasts, and antibiotic-resistant bacteria. In the clinical test, the inguinal and abdominal skin sites of human subjects were exposed to PGA for 30 seconds to assess the antimicrobial efficacy on normal skin flora. Betadine PVP-I scrub was tested in a 5-minute application as a control. RESULTS: The time-kill test showed that PGA delivered a rapid antimicrobial activity--reducing greater than 3 to 8 log microorganisms in 15 seconds in all of the 33 species of microorganisms tested. Within 30 seconds, all challenge organisms were reduced below detection level. Results of the minimum inhibition concentration test showed that PGA demonstrated an equivalent activity to Betadine control under the testing conditions. In the clinical test, PGA was effective in the reduction of greater than 3 log and 2 log of normal skin flora, respectively, in inguinal and abdominal sites in a single-step 30-second application. Bacteria levels remained significantly below the baseline for 6 hours in the primary study and for 24 hours in a secondary study. These results show that the current PGA formulation with a 30-second application delivers an efficacy equivalent to Betadine scrub in a 5-minute application and that the PGA formulation has a long-lasting effect--up to 24 hours. CONCLUSION: The PGA formulation delivered rapid and persistent antimicrobial activity against a broad spectrum of bacteria both in vitro and in vivo. PGA is an effective skin-preparation formulation for use in a single-step 30-second application.

Adolescent↗

Phytotoxicity of dredged sediment from urban canal as land application.

Phytotoxicity of dredged sediment from Hangzhou section of the Grand Canal as land application was evaluated by pakchoi (Brassica chinensis L.) germination tests and pot experiments. Germination rates of pakchoi in the dredged sediment and in sediment-applied soils were both significantly higher than that in the soil controls, while the germination rate between the sediment-applied soils was no significant difference. In pot experiments, plant height and biomass were increased by the dredged sediment application rate in the rate of lower than 540 t ha(-1), but decreased when the application rate was over this rate. Concentrations of Zn and Cu in pakchoi were linearly increased with the increasing of the application rate of the dredged sediment. Both plant height and biomass of pakchoi in sediment-treated red soil were higher than that in sediment-treated paddy soil, regardless the application rate. The results suggest that plant biomass of pakchoi may be used as an indicator of the phytotoxicity of the dredged sediment. It also showed that red soil is more suitable to accept the dredged sediment than paddy soil, and 270 t ha(-1) is a safe application rate both in red soil and paddy soil.

Biomass↗

Dietary exposures to mineral hydrocarbons from food-use applications in the United States.

Food-use applications of mineral hydrocarbons (MHC) derived from petroleum sources result in dietary exposure to these compounds by consumers. Food applications of MHC, including white mineral oils, paraffin waxes, microcrystalline waxes and petrolatum, include both direct-additive uses in which the MHC is intentionally applied to the food and indirect-additive uses in which the MHC become components of the food due to migration from food-contact surfaces. A key consideration in evaluating the safety of these uses of MHC is the level of exposure that results. We estimated exposures to MHC in the US from food applications based primarily on a food-consumption approach, in which MHC concentrations in foods were multiplied by the amount of these foods consumed. This was a conservative estimate, because it assumes that all foods that might contain MHC in fact do so at maximum possible concentrations. A "poundage approach", in which the amount of MHC used in food applications was divided by the US population to determine maximum potential per capita exposures, was used to validate the consumption-based estimates. Exposures to MHC from food-packaging applications were estimated using the FDA's food-factor approach, which takes into account the volume and kinds of food packaged with specific types of materials. A conservative estimate of mean exposure to all MHC types combined is 0.875 mg/kg BW/day. Half of this, 0.427 mg/kg BW/day, is white mineral oils used as pan-release lubricants in baking, for de-dusting of stored grain, in confectioneries, and in coatings for fruits and vegetables. Nearly all of the remainder, 0.404 mg/kg BW/day, is petrolatum, primarily from its use as trough grease in bakery applications. Exposure to paraffin and microcrystalline waxes combined is only 0.044 mg/kg BW/day.

Data Collection↗

Environmental benefits and economic costs of manure incorporation on dairy waste application fields.

Model simulations performed representing dairies in a 93000 ha watershed in north central Texas suggest that manure incorporation results in reduced phosphorus (P) losses at relatively small to moderate cost to producers. Simulated manure incorporation with a tandem disk on fields double-cropped with sorghum/winter wheat resulted in up to 33, 45, and 37% reductions in per hectare sediment-bound, soluble, and total P losses in edge-of-field runoff, relative to simulated surface manure applications. The effects of incorporation were evaluated at three different manure application rates. On aggregate across all three manure application rates, significant declines in P losses were obtained with incorporation except for sediment-bound P losses under the N-based manure application rate scenario. We found that the practice of incorporating manure shortly after it has been broadcast on the soil surface could help reduce P losses in such situations where P-based rates alone prove inadequate. The cost the producer incurs when manure is incorporated is on average about 1% of net returns when manure is applied at the N rate and 2-3% when it is applied at alternative P-based rates. In practice the costs could be lower because producers may substitute the manure incorporation operation for a tandem disk operation performed prior to manure application. As more and more dairy producers switch to the use of sorghum and corn silage in dairy rations and consequent on-farm production of these forages, the practice of manure incorporation may help to reduce phosphorus losses resulting from dairy manure applications to fields with these forage crops.

Animals↗

Angular directivity of thermal coagulation using air-cooled direct-coupled interstitial ultrasound applicators.

The performance characteristics and thermal coagulation of tissue produced by directional air-cooled, direct-coupled interstitial ultrasound (US) applicators were evaluated. Prototype applicators (2.2 mm o.d.) were constructed using cylindrical transducers sectored into angular active zones of 90 degrees, 200 degrees, 270 degrees, and 360 degrees. Acoustic characterization of the applicators showed the beam output to be angularly directed from the active sector of the transducer and collimated within the axial extent. Empirical determination of the average convective heat transfer coefficient, resulting from airflow cooling the inner surface of the transducer, showed significantly high levels of transfer (> 700 W m(-2) degrees C(-1)) with a flow rate of 5.6 L min(-1). Thermal performance of the applicators was characterized through high temperature heating in vivo (porcine thigh muscle, 11 trials) and in vitro (bovine liver, 46 trials). Results demonstrated directional coagulation of tissue, with good correlation between the angular extent of the lesions and the active acoustic sector. Radial depth of coagulation with a 200 degrees applicator extended 8-17 mm, with a heating time of 1-10 min, respectively. Angular and axial lesion shape remained similar over the course of 1-10 min heating trials. Implementation of air-cooling within direct-coupled interstitial US applicators provided enhanced directivity of heating in angular and axial dimensions, and significantly increased the power handling and radial depth of tissue coagulation.

Air↗

Development of an interstitial ultrasound applicator for endoscopic procedures: animal experimentation.

Biliary cancer is very difficult to treat, mainly because of the advanced stage at which such tumours are detected and the low efficacy of systemic therapeutic modalities like radiotherapy. Palliative measures designed to clear the duct (either by means of surgery or an endoscopic procedure) are presently performed. A relatively noninvasive alternative could be developed to fill this gap in the therapeutic arsenal. To this end, we have designed an interstitial ultrasound (US) applicator suitable for use with a digestive endoscope. This applicator is based on a water-cooled plane transducer that operates at 10 MHz. Although, because the target zone is cylindrical in shape, it might have seemed more logical to use a cylindrical transducer. Nevertheless, a plane transducer was chosen because the pressure field from this kind of emitter decreases less quickly, which means faster and deeper heating. However, to generate coagulation necrosis all around the duct, the applicator has to be rotated around its axis; this is achieved by means of a flexible metallic shaft (2 m in length and 3. 8 mm in diameter) that joins the device's active head (which contains the transducer) to the casing with all the connectors. A holder is fixed at the endoscope channel inlet; it controls the rotation of the applicator. Trials were conducted on pigs. The duodenoscope was introduced via the oesophagus down through the duodenum as far as the hepatopancreatic ampulla. Using a guide wire, the applicator was navigated into the duct via the endoscope instrument channel. Well defined, reproducible volumes of coagulation necrosis with a diameter of 20 mm were generated in the biliary tissue and the liver. These promising results indicate that this kind of endoscopic US delivery system may represent an effective tool for the treatment of biliary tumours in humans. An Independent Ethics Committee recently approved preliminary clinical trials of this applicator.

Animals↗

An analysis of the effect of ovoid shields in a selectron-LDR cervical applicator on dose distributions in rectum and bladder.

PURPOSE: A disadvantage of ovoid shields in a Fletcher-type applicator is that these shields cause artifacts on postimplant CT images. CT images, however, make it possible to calculate the dose distribution in the rectum and the bladder. To be able to estimate the possible advantage of having CT information over the use of ovoid shields without having CT information, we investigated the influence of shielding segments in a Fletcher-type Selectron-LDR applicator on the dose distribution in rectum and bladder. METHODS AND MATERIALS: Contours of rectum and bladder were delineated on transaxial CT slices of 15 unshielded applications. Of the volumes contained within these structures dose-volume histograms (DVHs) were calculated. In a similar way, DVHs of simulated shielded applications were calculated. The reduction, due to shielding, of the dose to the 2 cm3 (D2) and 5 cm3 (D5) volume of the cumulative DVHs of rectum and bladder, were determined. An isodose pattern in the sagittal plane through the center of each applicator was plotted to compare the location of the shielded area with the location of maximum dose in rectum and bladder in the unshielded situation. In two cases local dose reductions to the rectal wall were determined by calculating the dose in points at 10-mm intervals on the rectal contours. RESULTS: For the rectum, the reduction of D2 ranged from 0 to 11.1%, with an average of 5.0%; the reduction of D5 ranged from 2.3 to 12.1%, with an average of 6.4%. The reduction of D2 and D5 for the bladder ranged from 0 to 11.9% and from 0 to 11.6%, with average values of 2.2 and 2.6%, respectively. In 8 out of 15 cases the rectal maximum dose was located inferior to the shielded area. In all cases except one the bladder maximum dose was located superior to the shielded area. Local dose reductions on the rectal wall can be as high as 30% or more in an optimally shielded area. CONCLUSIONS: Reductions of D2 and D5 to rectum and bladder due to shielding are rather small, because the shielded area does usually not coincide with the high dose region and even if it does, the shielded area is too small to result in large reductions of these values. Because local dose reductions vary largely, one should proceed with caution when calculating the dose in just one rectal or bladder reference point. Because large overall dose reductions cannot be achieved with shielding, it is safe to use an unshielded applicator when post implant CT images are used to realize optimized dose distributions.

Artifacts↗

Surface applicators for high dose rate brachytherapy in AIDS-related Kaposi's sarcoma.

PURPOSE: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. METHODS AND MATERIALS: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. RESULTS: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. CONCLUSION: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion.

Acquired Immunodeficiency Syndrome↗

Dosimetric properties of a novel brachytherapy balloon applicator for the treatment of malignant brain-tumor resection-cavity margins.

PURPOSE: This paper characterizes the dosimetric properties of a novel balloon brachytherapy applicator for the treatment of the tissue surrounding the resection cavity of a malignant brain tumor. METHODS AND MATERIALS: The applicator consists of an inflatable silicone balloon reservoir attached to a positionable catheter that is intraoperatively implanted into the resection cavity and postoperatively filled with a liquid radionuclide solution. A simple dosimetric model, valid in homogeneous media and based on results from Monte Carlo photon-transport simulations, was used to determine the dosimetric characteristics of spherical geometry balloons filled with photon-emitting radionuclide solutions. Fractional depth-dose (FDD) profiles, along with activity densities, and total activities needed to achieve specified dose rates were studied as a function of photon energy and source-containment geometry. Dose-volume histograms (DVHs) were calculated to compare idealized balloon-applicator treatments to conventional 125I seed volume implants. RESULTS: For achievable activity densities and total activities, classical low dose rate (LDR) treatments of residual disease at distances of up to 1 cm from the resection cavity wall are possible with balloon applicators having radii between 0.5 cm and 2.5 cm. The dose penetration of these applicators increases approximately linearly with balloon radius. The FDD profile can be made significantly more or less penetrating by combining selection of radionuclide with source-geometry manipulation. Comparisons with 125I seed-implant DVHs show that the applicator can provide a more conformal therapy with no target tissue underdosing, less target tissue overdosing, and no healthy tissue "hot spots;" however, more healthy tissue volume receives a dose of the prescribed dosage or less. CONCLUSIONS: This device, when filled with 125I solution, is suitable for classical LDR treatments and may be preferable to 125I interstitial-seed implants in several respects. Manipulation of the dosimetric properties of the device can improve its characteristics for brain tumor treatment and may make it suitable for boosting the lumpectomy margins in conservative breast cancer treatment.

Brachytherapy↗

Decreased striatal dopamine efflux after intrastriatal application of benzazepine-class D1 agonists is not mediated via dopamine receptors.

Previous pharmacological studies have reported that striatal dopamine efflux is negatively modulated not only by presynaptic D2 dopamine autoreceptors but also by striatal D1 dopamine receptors. The present experiments employed in vivo microdialysis to further examine the ability of widely used benzazepine-class D1 agonists to modulate striatal dopamine efflux. In the present study, both the partial D1 agonist (+/-)-SKF 38393 (10 microM) and the full D1 agonist (+/-)-SKF 82958 (10 and 100 microM) significantly reduced striatal dopamine efflux during intrastriatal application. Intrastriatal application of the less active enantiomer, S(-)-SKF 38393 (10 microM) did not decrease striatal dopamine suggesting a selective receptor-mediated mode of action of (+/-)-SKF 38393. Additional experiments were conducted with the full D1 agonist (+/-)-SKF 82958 in order to characterize the receptor(s) mediating the observed decrease in dopamine efflux. Neither local application of the D1 antagonist R(+)-SCH 23390 (100 microM) nor local application of the selective D2 antagonist raclopride (5 microM) blocked the ability of (+/-)-SKF 82958 (10 microM) to decrease striatal dopamine efflux. However, intrastriatal application of the less selective D2 antagonist haloperidol (1 microM) did prevent the decrease in striatal dopamine efflux observed during intrastriatal (+/-)-SKF 82958 application. The present data suggest that the ability of intrastriatally applied benzazepine-class D1 agonists to decrease striatal dopamine efflux is receptor-mediated, but this action apparently is not mediated at D1 or D2 receptors. There is therefore no indication for an intrastriatal population of D1 receptors capable of modulating dopamine efflux.

2,3,4,5-Tetrahydro-7,8-dihydroxy-1-phenyl-1H-3-ben↗

Monitoring of pesticide applicators for potential dermal exposure to malathion and biomarkers in urine.

Malathion was applied to roses in three Finnish greenhouses by hand held lance sprayers. The potential dermal exposure of applicators to this insecticide was measured. Total urine production of each applicator was also collected up to 24 h post application. In the urine samples the specific metabolite of malathion, malathion monocarboxylic acid (MMA), and the creatinine content were determined. The potential dermal exposure results show that during the application of malathion, the applicators' lower limbs accounted, on average, for 48%, while the upper limbs accounted for 19% of the potential dermal exposure. Moreover, hands and chest and back and head regions accounted for 30 and 3%, respectively. Based on the urine measurements, it was observed that the excretion of MMA was very rapid reaching a maximum at about 6-7 h after the completion of the application. In the urine samples collected, MMA was found to be present in relatively small amounts.

Acids↗

Contrast enhancing agents in ultrasonography: clinical applications.

INTRODUCTION: As ultrasound remains a poorly sensitive method, echocontrast agents make a real difference. At least 29 echocontrast agents are currently on trial worldwide; their chemical composition, mechanisms of action and possible clinical applications are different. The state of the art of echocontrast agents is discussed: their established applications, those expected in the near future and finally their hypothetical, ideal applications. POTENTIAL CLINICAL APPLICATIONS: An extravascular and a vascular domain can be considered. The former includes the gastrointestinal tract and body cavities--both the normal (bladder, uterus, tubes and so on) and the abnormal (abscesses, fistulas, pericardium, peritoneum and so on) ones. Echocontrast agents can: (1) create or improve an acoustic window; (2) distend some organs and fill them with a liquid, with homogenous attenuation of the ultrasound beam; (3) displace the air-containing intestinal loops; (4) depict the walls, the shape and the contours of a normal or abnormal cavity; (5) detect abnormal communications, fistulas and drainages; and (6) evaluate the amount of fluid in the pleural, pericardial or peritoneal cavities. As for vascular applications, this domain sees the highest number of echocontrast agents on trial or on the market. The best know of them are: Levovist (Schering AG, Berlin, Germany), BR1 (Bracco, Milan, Italy) and EchoGen (Abbott, USA). All these act by enhancing arteries, veins and capillaries. The clinical applications validated in clinical trials mainly regard studies in intracranial and neck vessels and the vascularity of upper and especially lower limbs of renal vessels. Tumor macrovascularity (and in the future, hopefully microvascularity) can also be studied in parenchymatous and/or glandular organs, as well as in intra- and extra-abdominal parenchymatous organs in the periskeletal soft tissues. Clinical validation has also been obtained in the follow-up of tumors submitted to ablation therapy (chemoembolization, ethanol injection, thermal ablation) and in echocardiography, both for morphological studies in the cardiac cavities and for the cardiac wall perfusion. CONCLUSIONS: In a subgroup of 513 out of 1275 patients examined Europe-wide, the contrast agent Levovist increased the diagnostic confidence from 27.4 +/- 22.5 to 77.2 +/- 22.5%. Such data encourage further trials to validate current preliminary results.

Contrast Media↗

Provision of anesthesia with single application of lidocaine 2% gel.

PURPOSE: To compare the efficacy of a single application of lidocaine 2% gel with tetracaine 0.5% drops for topical anesthesia in clear corneal cataract surgery. SETTING: The Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: A preliminary toxicity study applied lidocaine 2% gel in the conjunctival fornices of rabbit eyes (n = 9). Biomicroscopic examination was performed and then enucleation at sequential intervals after the application. Intentional intracameral injection of lidocaine gel was performed (n = 3), followed by enucleation. Histopathological analysis was performed on all eyes. A randomized clinical trial comparing topical anesthesia in clear corneal cataract surgery was performed in 25 eyes of 25 patients (12 eyes randomly assigned to lidocaine gel, 13 eyes to tetracaine drops). Corneal sensation was measured with the Cochet-Bonnet aesthesiometer before application of the topical anesthesia, 5 minutes after application, and at the conclusion of surgery. Additional intraoperative local anesthesia and systemic sedation were recorded. Patients' subjective level of comfort was reported 20 minutes after surgery, and the surgeon's perception of patients' comfort was also noted. RESULTS: In rabbits, lidocaine gel did not cause clinical or histopathological alteration of the ocular tissues. In the clinical study, median corneal sensitivity before application, after 5 minutes, and postoperatively was 6, 0, 0 (maximum sensitivity = 6), respectively, in the lidocaine gel group and 5, 0, 0, respectively, in the tetracaine drops group. Additional local anesthesia was administered in 17% and 31% of patients, respectively. Satisfactory comfort was reported by 58% in the lidocaine gel group and 62% in the tetracaine drops group. CONCLUSIONS: A single application of lidocaine 2% gel was a safe and effective alternative to multiple topical anesthetic drops for clear corneal cataract surgery. Lidocaine 2% gel was similar to tetracaine drops in provision of corneal anesthesia and patient comfort, while causing no significant toxicity to the ocular surface.

Aged↗

Evolution of fibrin glue applicators.

Fibrin glue (FG) is used worldwide as a potent surgical tool, which establishes hemostasis in wounds and also bonds tissue. The standard FG applicator is based on a dual-syringe system. This review, based mainly on the patent literature, describes the development of the quasi-standard dual syringe system as well as the rise of other FG applicator designs based on mechanical force (ratchet systems), Bernoulli gas flow, positive gas pressure, or electro-servo devices. The packaging of commercial FG components is reviewed within the context of "loading" the FG applicators and the need to minimize the number of needles required to access the packaged (vials) components. Parameters such as internal clogging, homogeneity of spray, the requirement for gas or vacuum house lines, the number of parts that must be handled, and the time required to assemble the applicator, load it, and have it ready for use are also discussed. A rating system is proposed that permits one to use such parameters to rank the various applicator designs, relative to the dual-syringe system. Hopefully, this review will stimulate the design of better FG applicators and packaging required for elective surgery, emergency treatments, and tissue engineering in the 21st century.

Equipment Design↗

Urinary biomarkers of atrazine exposure among farm pesticide applicators.

PURPOSE: This study assessed the feasibility of three laboratory methods for the detection of atrazine, a triazine herbicide, and its related metabolites in urine collected from field applicators.METHODS: Urine samples were collected from 256 randomly sampled field applicators 8 hours post application. Of these, 99 reported atrazine use during the application prior to sample collection and these samples were subsequently analyzed for urinary biomarkers.RESULTS: 37.4% (n = 37) samples showed detectable levels (minimum = 1.0 ng/mL) of deethylatrazine using gas chromatographic mass spectrometry (GCMS) analysis (X = 14.2 ng/mL; s.d. = 13.5). Fifty samples were tested using atrazine mercapturate in urine ELISA methods and 80% (n = 40) of these samples showed detectable levels of atrazine (X = 6.4 ng/mL; s.d. = 7.5). Of 10 samples tested by triazines in water ELISA methods, a common assay used for the detection of atrazine in groundwater, 100% showed detectable levels of atrazine (X = 22.4 ng/mL; s.d. = 13.9). Of the 21 samples collected from non-applicators and tested by GCMS, none evidenced detectable atrazine levels. Using GCMS as the gold standard, analyses showed that the mercapturate in urine ELISA was 48% sensitive and 91% specific whereas the triazines in water ELISA was 69% sensitive and 100% specific.CONCLUSIONS: It is possible to detect one-time atrazine exposures through analysis of urinary biomarkers among pesticide applicators. The feasibility of triazines in water ELISA methods for use in field studies for analyzing the presence of atrazine and related metabolites in urine was supported, but these methods need further testing on larger applicator samples before they can be used for standard screening.

Journal Article↗

Sub-microsecond, intense pulsed electric field applications to cells show specificity of effects.

Application of sub-microsecond duration (60-300 ns), intense (15-60 kV/cm) pulsed electric fields (sm/i-PEF) to six types of human cells was examined for its effects on individual cell surface membrane permeability and membrane potential. With short (60 ns) pulses, increasing percentages of Jurkat cells showed propidium iodide (PI) uptake at progressively shorter post-pulse times as the pulse train increased from 1 to 10 sequential pulses, while human blood polymorphonuclear leukocytes (PMN) were unresponsive to these short pulses regardless of train size. With 300 ns pulses, a similar pattern (increasing percentages of cells taking up PI, and progressively shorter times of onset after pulse applications as pulse train size increased) was seen with both Jurkat cells and PMN, but the patterns for both effects were different. Jurkat cell size did not appear to influence the responsiveness of this cell type. Comparisons of sm/i-PEF-induced PI uptake by human monocyte-derived macrophages vs. aged human mononuclear cells, human trunk skin (HTS) cells vs. fresh human mononuclear cells and human macrophages vs. HTS cells showed similar overall effects, but with differences between the patterns for each cell type compared (except the macrophages vs. HTS cells comparison). Application of sm/i-PEFs also caused different patterns of membrane potential loss in Jurkat cells vs. PMN. Jurkat cells developed significant decreases in t heir membrane potential only following the highest intensity pulse applications examined, i.e., 300 ns, 60 kV/cm x5, while PMN showed this effect over the entire range of pulse intensities (300 ns, 15-60 kV/cm, x5) applied. These data indicate that sm/i-PEF applications can have "specificity" (i.e., achieve different levels of effect in different cell types), that cell size does not appear to be the major factor determining sm/i-PEF effects in either Jurkat cells or PMN, that heterogeneous sm/i-PEF effects on cells tend to become homogeneous with increasing pulse train size, and that specificity of sm/i-PEF applications effects can occur at either end of the sm/i-PEF intensity spectrum examined.

Age Factors↗

The effects of application of poultry manure to crude oil polluted soils on maize (Zea mays) growth and soil properties.

An investigation of the effects of application of poultry manure to crude oil polluted soils on the growth of maize and soil properties was carried out under natural conditions at the Ambrose Alli University, Ekpoma, Nigeria. Potted maize plants were treated to crude oil pollution at four different levels (0, 25, 50 and 75 mL) and amended with poultry manure at four rates of application (0, 50, 100 and 150 kg ha(-1)) two weeks after pollution. Results obtained showed that percent survival rate, plant height and dry matter yield decreased with increase in crude oil contamination. For example % seed germination decreased from 93 to 0% as crude oil increased from 0 to 75 mL without poultry manure application while plant height decreased from 97 to 20 cm. However when amended with poultry manure, statistical analysis showed that the highest rate of crude oil application (75 mL) and the 150 kg ha(-1) rate poultry manure application affected maize growth, dry matter yield and soil properties significantly. For example at the 75 mL crude oil application, plant height increased from 20 to 149 cm as level of manure applied increased from 0 to 150 kg ha(-1) while dry matter yield increased from 27 to 58 g.

Animals↗