PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Catheterization, Peripheral”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Processing of peripheral blood progenitor cell components in improved clean areas does not reduce the rate of microbial contamination.

BACKGROUND: Microbial contamination of peripheral blood progenitor cell components (PBPCs) may cause severe complications in immunosuppressed recipients. Therefore, principles of Good Manufacturing Practice (GMP) are applicable for processing of PBPC components to reduce potential risks of contamination. STUDY DESIGN AND METHODS: It was investigated in a retrospective study whether the microbial contamination of PBPC components could be reduced after processing in improved clean areas according to the "Manufacture of Sterile Medicinal Products." Starting in 1994, a total of 1478 autologous and allogeneic PBPC components have been collected and processed into 3149 cryopreservation bags at the Department of Transfusion Medicine. Sterility testing was performed for all bags. Until December 1998, 783 PBPC components were processed at a clean bench only (group I). Thereafter, 695 PBPC components have been processed at a clean bench located in a clean area with an airlock system for personnel and equipment (group II). RESULTS: In group I, 16 of 1555 bags (1.03%) showed positive results in the first sterility testing. In group II, 21 of 1594 bags (1.32%) were positive (p = NS). The clinical follow-up was inconspicuous. CONCLUSION: Microbial contamination of PBPC components could not be reduced by installation of improved clean area conditions.

Adult↗

Safety of peripheral intravenous catheters in children.

OBJECTIVES: To determine the overall and per-day risk of complications of short peripheral intravenous (PIV) catheters placed for indefinite periods. DESIGN: During 5 months, general pediatric patients receiving intravenous therapy through short PIV catheters were monitored. Patient and catheter characteristics were recorded, complications were noted, and rolled semiquantitative cultures of removed catheters were performed. Major endpoints were infection and phlebitis. Per-day risk of complications and catheter colonization (>15 colony-forming units) were calculated. SETTING: University children's hospital. PATIENTS: General pediatric ward inpatients with PIV. RESULTS: We studied 642 Teflon catheters in place >24 hours (mean, 3.7 days) in 525 patients. There were no cases of catheter sepsis (0%; 95% confidence interval [CI95], 0%-0.6%), one possible insertion-site infection (0.2%; CI95, 0.004%-0.9%), and seven cases of phlebitis (1.1%; CI95, 0.4%-2.3%). Catheter colonization occurred in 92 (26%) of 348 catheters cultured. Neither the per-day risk of phlebitis nor of catheter colonization increased significantly with placement >3 days. CONCLUSION: Current guidelines recommend replacement of PIV catheters in adults within 2 to 3 days; no recommendations are made for children. Our findings and those of others indicate that the overall risk of PIV catheter complications in children is extremely low and would not be reduced substantially by routine catheter replacement.

Bacteria↗

A randomized trial comparing peripherally inserted central venous catheters and peripheral intravenous catheters in infants with very low birth weight.

BACKGROUND/PURPOSE: To determine whether percutaneously inserted central venous catheters (PICC) and peripheral intravenous catheters (PIV) in infants with very low birth weight (VLBW) differ with respect to (1) incidence of sepsis, (2) number of insertion attempts and catheters required for total intravenous therapy, (3) courses of antibiotics, and (4) total duration of intravenous (IV) use. METHODS: A randomized comparative trial was conducted involving 63 VLBW infants (<1,251 g) who required IV therapy. Infants were assigned randomly at 1 week of age to either a PIV or a PICC catheter and followed up prospectively until an IV was no longer required or the infant was transferred out of the neonatal intensive care unit. RESULTS: Data were analyzed on an intention-to-treat basis. There was no difference in the incidence of sepsis (P = .64), number of courses of antibiotics (P = .16), or total duration of IV use (P= .34) between the 2 groups. The number of insertion attempts required for total IV therapy was significantly lower in the PICC group than in the PIV group (P = .008). There also was a significantly lower number of total catheters utilized in the PICC group (P = .002). When data were controlled for birth weight strata the results were similar. CONCLUSION: PICC lines reduced the number of painful IV procedures in VLBW infants without additional morbidity.

Catheterization, Central Venous↗

The continuous femoral nerve block catheter for postoperative analgesia: bacterial colonization, infectious rate and adverse effects.

UNLABELLED: We investigated the incidence of bacterial and vascular or neurological complications resulting from femoral nerve catheters used for postoperative analgesia. Patients requiring continuous femoral blockade were consecutively included. Using surgical aseptic procedure, 211 femoral nerve catheters were placed (short-beveled insulated needle, peripheral nerve stimulator). After 48 h, each catheter was removed and semiquantitative bacteriological cultures were performed on each distal catheter tip. Postoperative analgesia and antibiotics were standardized. All complications during the insertion of the catheters and postoperatively (after 48 h and 6 wk) were noted. Few initial complications with no immediate or delayed complications were noted (20 difficult insertions, 3 impossible injections, 3 ineffective catheters, and 12 vascular punctures). After 48 h, 208 catheters were analyzed; 57% had positive bacterial colonization (with a single organism in 53%). The most frequent organisms were Staphylococcus epidermidis (71%), Enterococcus (10%), and Klebsiella (4%). Neither cellulitis nor abscess occurred. Three transitory bacteremias likely related to the catheter occurred. After 6 wk, no septic complications were noted. One femoral paresthesia, partially recovered 1 yr later, was noted. We conclude that the risk of bacterial complications is small with femoral nerve catheters, although the rate of colonization is frequent. IMPLICATIONS: In this prospective study, continuous femoral nerve catheters were effective for postoperative analgesia but had a frequent rate of bacterial catheter colonization. We found no serious infections after short-term (2-day) infusion. Side effects were few, but one nerve injury occurred.

Adolescent↗

Radial artery cannulation: a comparison of 15.2- and 4.45-cm catheters.

Eighty-nine patients were studied prospectively to compare the incidence of postdecannulation arterial thrombosis and ischemic complications associated with percutaneous insertion of two different radial artery catheters. Patients scheduled for peripheral vascular surgery were randomized to receive a 15.2-cm (6 in, Argon Medical Corp.) or 4.45-cm (1.75 in, Arrow International, Inc.) 20-gauge, Teflon catheter. Extremity blood flow was evaluated prior to cannulation and again after decannulation with the modified Allen's test, pulse-volume plethysmography, and Doppler ultrasound. The incidence of postdecannulation radial artery occlusion for 15.2-cm catheters was significantly less than for 4.45-cm catheters (4 of 45 cases versus 11 of 44 cases, p = 0.05). No case of temporary or permanent ischemic injury occurred. Radial artery transfixion (16 of 45 cases versus 5 of 44 cases, p = 0.01) and hematoma formation (5 of 45 cases versus 0 of 44 cases, p = 0.02) occurred more frequently during insertion of 15.2-cm catheters than 4.45-cm catheters. The number of arterial punctures during catheter insertion and the duration of cannulation were similar for both groups. Of the 8 patients with positive modified Allen's test who underwent radial artery cannulation, one suffered arterial occlusion. Radial artery cannulation with a 15.2-cm catheter was associated with a lower incidence of postdecannulation radial artery thrombosis than cannulation with the 4.45-cm catheter. Radial artery cannulation with longer catheters (greater than 5.0 cm) appears to be a safe practice.

Brachial Artery↗

[US-guided percutaneous management of femoral artery pseudoaneurysms by thrombin injection: personal experience and review of the literature].

Treatment of femoral artery pseudoaneurysms includes US-guided compression, endovascular coil embolisation or stenting, thrombin injection and open surgical repair. Thrombin injection is currently the standard approach to all non-complicated pseudoaneurysms of the peripheral arteries. Between January 2001 and December 2004, 59 pseudoaneurysms of the femoral artery were submitted to percutaneous US-guided thrombin injection in our surgery division. Complicated pseudoaneurysms, patients in whom percutaneous treatment failed, and chronic pseudoaneurysms with large necks were excluded from this kind of treatment and underwent surgical repair. Eighteen patients were on therapeutic anticoagulation (30.5%) and none of the pseudoaneurysms had an associated arteriovenous fistula. All patients were submitted to clinical and ultrasound follow-up at 24 hours and at 1, 6 and 12 months, and thereafter at yearly intervals for evaluation of recurrences. The thrombin injection was successful in 57/59 patients (96.6%) while two patients (3.4%) were submitted to surgical treatment after failure of the procedure. In 1 patient (1.7%) an additional injection was necessary to achieve complete thrombosis of the pseudoaneurysm. No complications occurred; none of the patients reported discomfort and there was no request for sedation. No recurrences were seen at follow-up. Nowadays US-guided percutaneous thrombin injection is the treatment of choice for femoral artery pseudoaneurysms. Surgical treatment is reserved to rare selected cases. More studies are necessary to evaluate further indications for treatment of visceral or small distal artery pseudoaneurysms.

Adult↗

Peripheral intravenous line survival and phlebitis prevention in patients receiving intravenous antibiotics: heparin/hydrocortisone versus in-line filters.

OBJECTIVE: To compare the use of in-line filtration with the addition of heparin/hydrocortisone (hep/hc) to the infusate for both phlebitis prevention and intravenous (i.v.) line survival in peripheral i.v. catheters. This study was specific for a patient group receiving prolonged courses of i.v. antibiotics. Analysis of the two endpoints for conventional short i.v. catheters (short lines) versus long (30 cm) i.v. catheters (long lines) was also performed. METHODS: Patients with cystic fibrosis receiving intermittent i.v. antibiotics were randomly allocated to receive their drugs either through an in-line filter using a drug-free infusate or with no filter and an infusate containing heparin 500 units and hydrocortisone 10 mg/L. Infusion sites were assessed daily. RESULTS: Both the hep/hc and filter groups were similar in terms of phlebitis incidence and i.v. line survival when analyzed separately for both short and long lines. Long lines displayed markedly prolonged survival times and reduced phlebitis compared with short lines. CONCLUSIONS: The effectiveness of i.v. filters in excluding the large particle load introduced by i.v. antibiotics and hence in reducing the subsequent phlebitis makes them a useful alternative to the use of hep/hc. The use of filters in this patient group may offer advantages in terms of ease of use and a possible decrease in hep/hc-related problems. Long lines offer practical advantages over short lines for patients requiring longer term i.v. access.

Anti-Bacterial Agents↗

[Fiberoptic measurement of arterial oxygen saturation in premature and term neonates].

BACKGROUND: Non-invasive oxygen monitoring with pulse oximetry or transcutaneous monitoring has gained widespread use in neonatology. Different factors like arterial hypotension, peripheral vasoconstriction and edema adversely affect the accuracy of both methods. To ensure reliable monitoring of oxygen saturation in critically ill patients we measured oxygen saturation with a fiberoptic catheter via umbilical artery. METHODS: In ventilated premature infants (FiO2 > 0.4) a 4F-fiberoptic catheter (Oximetrix)-3, Abbott) was inserted to the descending aorta (Th 6-8). Simultaneously pulse oximetry (SaPO2) was performed with the Ohmeda Biox 3700. To compare the reliability of both methods, blood was analysed for arterial partial oxygen pressure (PaO2), fetal hemoglobin (HbF) and arterial oxygen saturation (SaO2) by complete co-oximetry (Radiometer Copenhagen OSM3) as reference. RESULTS: In 10 premature infants (median gestational age 30.5 weeks; median birth weight 1360 g) oxygen saturation was measured with the fiberoptic catheter (SaFO2) over a total period of 935 hours. In all, 137 blood samples were analysed for arterial saturation (SaO2) by co-oximetry. The mean difference between the SaO2 and SaFO2 was -1.89% (+/- 1.53); the mean difference between SaO2 and the values obtained by pulse oximetry (SaPO2) was -3.09% (+/- 2.33). The SaFO2 results correlated closely with the co-oximetry values (r = 0.97; p < 0.0001). CONCLUSION: In critically ill patients, if non-invasive oxygen monitoring fails, a fiberoptic catheter offers the possibility of continuous and reliable measurement of oxygen saturation.

Blood Gas Monitoring, Transcutaneous↗

[A modified technic for local rt-PA catheter-mediated lysis].

PURPOSE: To develop an economic and efficient concept for more time-saving local rt-PA thrombolysis therapy. METHOD: 40 patients with peripheral vascular occlusive disease stage IIb-III according to the Fontaine classification and with angiographically proven occluded segments of pelvic and lower limb arteries were treated by a modified concept of local rt-PA catheter thrombolysis. Via a thin guide wire the catheter for thrombolysis is slowly advanced through the thrombus without fluoroscopic control, outside the room in which angiography is performed. In 24 cases a short-term lysis and in 16 cases a long-term lysis was carried out. RESULTS: The initial success rate was 75%, the patency rate in six months' follow-up was 66.7%. The ankle-brachial index decreased from 0.4 +/- 0.3 to 0.8 +/- 0.2 on the average. There were no relevant clinical complications. The average occupancy time of the angiography room or table was 60 +/- 52 min, the average time of fluoroscopy was 17 +/- 13 min. CONCLUSION: In modified local rt-PA thrombolysis, short-term lysis and long-term lysis were mostly performed outside the angiography room, so that the exposure to radiation and there fore the radiation dose were reduced for both the patient and the attending staff. The angiography room is thus available for other patients and can therefore be used more efficiently.

Adult↗

The Angiomax Peripheral Procedure Registry of Vascular Events Trial (APPROVE): in-hospital and 30-day results.

BACKGROUND: High-risk patient characteristics and complexity of percutaneous peripheral intervention (PPI) procedures suggest a need for predictable and reliable anticoagulation. We undertook this study to assess the safety and efficacy of bivalirudin as the procedural anticoagulant in patients undergoing PPI of the renal, iliac, or femoral artery. METHODS: This was a prospective, open-label, single arm study inpatients undergoing PPI of the renal, iliac, or femoral vessels to assessbivalirudin as the sole procedural anticoagulant (0.75 mg/kg bolus/1.75 mg/kg/hr infusion). The primary endpoint was procedural success defined as residual stenosis < 20%. Secondary endpoints included ischemic events (death, myocardial infarction, unplanned revascularization, and amputation), and bleeding complications, as well as ACT values and times to sheath removal, ambulation, and discharge. RESULTS: 505 patients were enrolled at 26 sites. Procedural success was achieved in 95.0% of patients. Ischemic events were low (1.4%) and similar between vessel types. Protocol-defined major hemorrhage and TIMI major hemorrhage rates were 2.2% and 0.4%, respectively. Mean ACTs were similar among treatment groups (renal 353.8 seconds(s); iliac 335.9s, femoral, 343.5s). CONCLUSION: Bivalirudin provided consistent anticoagulation and similar outcomes in all vessel types treated at the dose tested. Ischemic and bleeding event rates were low, demonstrating the safe use of bivalirudin as a procedural anticoagulant in PPI.

Aged↗

Thrombolysis with tissue-plasminogen activator: results with a high-dose transthrombus technique.

PURPOSE: Low-dose intraarterial tissue plasminogen activator (t-PA) is effective in peripheral thrombolysis but treatment time is prolonged. The aim of this study was to determine whether a transthrombus bolus of t-PA before low-dose infusion shortens lysis time. METHODS: Twenty-three patients with peripheral arterial or bypass graft occlusion were treated with an initial bolus of 20 mg t-PA followed by a continuous infusion of 1 mg/hr. RESULTS: Angiographic lysis was achieved in 16 patients (70%) with a mean time to complete lysis of 14.4 +/- 7.9 hours. Two patients had reocclusion on days 1 and 3, respectively. There were three deaths within the first week of treatment, one from cerebral hemorrhage and two from myocardial infarction. A clinically successful outcome was achieved in 11 patients (48%). Those patients with patency at 1 week maintained this response at a mean follow-up of 11.7 +/- 9.1 months. Thrombolysis was unsuccessful in seven instances. In three of these cases the infusion had to be discontinued prematurely because of serious hemorrhage. Of the seven unsuccessful cases, three patients subsequently underwent a femorodistal bypass, two were left with tolerable ischemic symptoms, and two required a major amputation. There were eight major bleeding complications (35%), four at or adjacent to the catheter entry site and four at a distance, including two cases of cerebral hemorrhage, one of which was fatal. CONCLUSIONS: Transthrombus bolus delivery of tissue plasminogen activator followed by a low-dose infusion shortens lysis time, but this technique appears to be associated with an increased risk of serious hemorrhage.

Adult↗

Percutaneous intravascular US as adjunct to catheter-based interventions: preliminary experience in patients with peripheral vascular disease.

Catheter-based ultrasound (US) transducers may be introduced into the vascular system to record high-resolution images of the vessel wall and lumen. The potential advantages and existing liabilities of percutaneous intravascular US as an adjunct to transluminal vascular recanalization were investigated. A 6.6-F braided, polyethylene catheter enclosing a rotary drive shaft with a single-element, 20-MHz transducer at the distal tip was used in 17 patients undergoing percutaneous transluminal (balloon) angioplasty (PTA) alone (10 patients), PTA with implantation of an endovascular stent (two patients), atherectomy alone (two patients), or laser angioplasty with PTA and/or atherectomy (three patients). The arteries treated and examined included the common iliac in five patients, the external iliac in two, the superficial femoral in nine, and a vein graft-arterial anastomosis in one. In 14 cases PTA was employed as sole or adjunctive therapy; plaque cracks were clearly delineated with intravascular US in all 14 (100%) and dissections were observed in 11 (78%). Plaque-arterial wall disruption was less prominent in the arteries treated with mechanical atherectomy. The results of laser angioplasty reflected the adjunctive modality employed. After stent implantation, serial intravascular US documented effacement of PTA-induced plaque cracks and/or dissections. Intravascular US also aided in the quantitative assessment of luminal cross-sectional areas after the procedures (19.0-51.8 mm2). The observations recorded in this preliminary group of 17 patients illustrate the potential utility of intravascular US as an adjunct to conventional angiography in patients undergoing percutaneous revascularization.

Aged↗

[Does fentanyl or midazolam improve patient's comfort and cooperation when given for regional catheter placement? A randomized, controlled and double-blind trial].

BACKGROUND: The procedure of placing a catheter for continuous regional anaesthesia is often associated with fear and pain in the patient. Thus, we evaluated the use of midazolam and fentanyl to improve patient's comfort and cooperation. METHODS: After an oral dose of 20 mg clorazepate, 174 patients receiving peripheral nerve catheters for regional anaesthesia where randomized into 3 groups to receive either intravenous placebo, 3 mg midazolam or 0.1 mg fentanyl immediately before catheter placement in a double-blind manner. Stepwise regression analysis was used to identify factors associated with patient's assessment of subjective discomfort (measured using a VAS 0-10) during the procedure. Amnesia was evaluated 24 h later. The anaesthetist rated patient's cooperation during catheter placement. RESULTS: Female sex and longer duration of catheter placement had significant negative impact on patient's comfort, whereas fentanyl showed an improvement. Age, body mass index, midazolam and the type of catheter had no influence. The following day 27% of the midazolam group, 6% of the placebo group and 9% of the fentanyl patients did not remember catheter placement. Patient's cooperation was poor in 26% of the midazolam patients but only in 9% of the placebo and 3% of the patients receiving fentanyl. Of the placebo patients 18.4% had to be supplemented with fentanyl because they found the procedure of catheter placement unbearable. No side effects occurred in either group. CONCLUSION: As patient's comfort and cooperation were significantly improved by fentanyl, we recommend fentanyl to facilitate catheter placement for regional anaesthesia.

Aged↗

Comparison of intravascular ultrasound, external ultrasound and digital angiography for evaluation of peripheral artery dimensions and morphology.

Validation of catheter-based intravascular ultrasound imaging has been based on comparisons with histology and digital angiography, each of which may have limitations in the assessment of arterial size and morphology. External, high-frequency ultrasound can accurately determine vessel dimensions and morphology and because, like ultravascular ultrasound, it also provides cross-sectional arterial ultrasound images, it may be a more appropriate technique for the in vivo comparison of arterial dimensions and morphology determined by intravascular ultrasound. Thus, intravascular ultrasound, external 2-dimensional ultrasound, Doppler color-flow imaging and digital angiography were compared for assessment of arterial dimensions and wall morphology at 29 femoral artery sites in 15 patients. Intravascular ultrasound and the other 3 imaging modalities correlated well in determination of lumen diameter (2-dimensional, r = 0.98, standard error of the estimate [SEE] = 0.14; Doppler color flow, r = 0.91, SEE = 1.11; angiography, r = 0.95, SEE = 0.91) and cross-sectional area (2-dimensional, r = 0.97, SEE = 0.04; Doppler color flow, r = 0.92, SEE = 0.14; angiography, r = 0.96, SEE = 0.08). However, lumen size measured by Doppler color flow was consistently smaller than that measured by the other 3 imaging modalities. Intravascular ultrasound detected arterial plaque at 15 sites, 5 of which were hypoechoic (soft) and 10 hyperechoic with distal shadowing (hard). Plaque was identified at 12 of 15 sites by Z-dimensional imaging (p = 0.30 vs intravascular ultrasound), but at only 6 of 15 sites by angiography (p = 0.003 vs intravascular ultrasound), only 1 of which was thought to be calcified plaque.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

High rate of complications associated with peripherally inserted central venous catheters in patients with solid tumours.

BACKGROUND: Peripherally inserted central catheters (PICC) have been used extensively as a cost-effective and safe form of medium-term intravascular access. There are only limited data about complications of PICC lines in oncology patients despite theoretical concerns about the higher risks of complications in these patients as a result of cancer itself and cancer therapy. AIMS: To document the frequency and type of PICC complications in patients with solid tumours. METHODS: All patients with solid tumours who were treated at Flinders Medical Centre, Adelaide, South Australia, Australia between January 2000 and March 2001 were included in a retrospective review of PICC complications. RESULTS: Twenty-seven PICC lines were inserted in 17 patients; 40.7% (11/27) of PICC lines developed complications requiring early removal of the PICC. Complications encountered were sepsis (systemic and cellulitis), thrombosis, blockage and leakage. Septic complications were found at a rate of 8/1000 PICC days or 25.7% (7/27) of PICC inserted. The median dwell time was 20 days. The mean time for a complication to occur was 27.5 days. CONCLUSIONS: The present study demonstrates a high rate of complications, which is higher than the complication rates reported in studies of non-oncology patients. PICC lines should be used with caution in patients with solid tumours. Prospective studies of the factors influencing the incidence of complications might be warranted.

Antineoplastic Agents↗

Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity.

PURPOSE: This study examines whether the tip of peripherally inserted central catheters (PICCs) moves significantly with changes in arm position from abduction to adduction. MATERIALS AND METHODS: The catheters were inserted in the brachial or basilic veins under ultrasonographic guidance with the upper extremity in a 90 degrees abducted position. A flexible, radiopaque ruler was then placed on the anterior chest and digital images were obtained with the arm abducted and adducted in a similar phase of quiet respiration. Catheter tip movement was measured with use of the radiopaque ruler and fixed, bony anatomic landmarks. RESULTS: Sixty-one consecutive PICCs were placed and evaluated during the study period (eight patients were excluded). Thirty-three catheters were placed from the right arm and 20 from the left. Overall, 43 moved caudally, seven moved cephalad, and three did not move with movement of the arm from abduction to adduction. Of those that moved caudal, the mean distance of movement was 21 mm (range, 2-53 mm). Right arm PICCs tended to move more than left arm PICCs, but this did not attain significance (P = .29). CONCLUSIONS: There is a tendency for the PICC tip to move in a caudal direction with the change in arm position from abduction to adduction; 58% of PICCs moved 20 mm or more. This change in position should be considered during final catheter tip positioning.

Adolescent↗

Treatment of extravasation from parenteral nutrition solution.

OBJECTIVE: To report two cases of parenteral nutrition extravasation and their treatment in adult patients. CASE SUMMARIES: Case 1: A 23-year old white woman was admitted to our hospital diagnosed with a gastrointestinal infection by Salmonella paratyphi sv. B. The treatment included peripheral parenteral nutrition (osmolarity 652 mOsm/L). After 4 days an extravasation of parenteral nutrition was detected in the left antecubital fossa. The affected area soon became inflamed. Chondroitinsulfatase 150 turbidity-reducing units (TRUs), diluted in 3 mL of NaCl 0.9% and administered in six subcutaneous applications around the area, was prescribed. The treatment was successful. The patient was discharged several days later with no sequelae of the extravasation. Case 2: A 33-year-old white woman was admitted to the intensive care unit after surgery for a necrohemorrhagic pancreatitis. The treatment included parenteral nutrition via a central catheter (osmolarity 2130 mOsm/L). Two days later the patient presented a parenteral nutrition subcutaneous extravasation in her left hemithorax around the catheter access site. Chondroitinsulfatase 200 TRUs, diluted in 2 mL of NaCl 0.9% and administered in eight subcutaneous applications around the area, was prescribed. No sequelae of the incident remained. The patient was discharged home 2 months later. DISCUSSION: Parenteral nutrition solution can cause tissue harm after extravasation. Both patients presented an intense inflammatory reaction after the accident. Three treatments have been used in extravasation of parenteral nutrition, but in our patients hyaluronidase was the only applicable treatment. As this enzyme is not commercially available in Spain, chondroitinsulfatase, an enzyme very similar to hyaluronidase, was used. CONCLUSIONS: Chondroitinsulfatase was useful in treating extravasation of parenteral nutrition in two adult patients.

Adult↗

The care and handling of peripheral intravenous cannulae on 60 surgery and internal medicine patients: an observation study.

The purpose of this study was to analyse the actual routines surrounding the use of peripheral cannulae and the occurrence of complications. Thirty surgery patients and 30 internal medicine patients were observed daily at a medium-sized hospital. The patients were followed from the time the cannula was inserted until after withdrawal and until both the insertion site and the vein were free from pain. The results showed that most of the cannulae were placed on the upper side of the hand and sizes most frequently used were 1.0 and 1.2 mm. The fixation was unsatisfactory in 23 cases already after the second day. Twenty-three cannulae were removed after 24 hours. Thirty-seven (62%) patients were stated to have thrombophlebitis phlebitis in different degrees. Only seven cannulae fulfilled the criteria for good cannula care and handling. The frequency of complication was especially high when fructose-glucose, antibiotics or anticoagulants were given. There was no documentation in the patient record, according to current laws in Sweden. The complications observed were redness, swelling, haematoma, subcutaneous swelling and suppurating infection. The study showed that the longer the cannula had been in situ, the greater were the complications (very distinct after 24 hours). The care and handling was unsatisfactory to very unsatisfactory in 52% of the cases. Complications can last for a very long time. In this research, pain was noted up to 5 months after the cannulae were removed.

Adult↗