PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “TRICUSPID STENOSIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Echocardiographic and hemodynamic relationships of ejection sounds.

The physiologic correlates of ejection sounds have been studied by simultaneous phonocardiograms, echocardiograms and high fidelity pressure tracings. Ejection sounds associated with semilunar valve stenosis or hypertension of the systemic or pulmonary circulation occur at the moment of complete opening of the aortic or pulmonary valve recorded echocardiographically. The start of opening of these valves occurs at the onset of the pressure rise in the corresponding great vessel and completion of valve opening always occurs on the pressure upstroke. The ejection sound in the presence of stenotic valves occurs with checking of the opening motion of the thickened valve cusps. Although the hypertensive ejection sounds also occur at the precise moment of full opening of the valve it remains to be seen whether this relationship is causal or coincidental.

Aorta↗

The management of valvular heart disease in children.

The child with significant valvular heart disease may present in any single instance both the most difficult of management decisions or a surprisingly simple one. Thus, if a direct surgical approach on the valve is feasible, the problems may very well be quite simple and straightforward; conversely, if valve replacement is indicated such may not be the case. We have recently reported our experience with one type of valvular heart condition, congenital aortic stenosis, in respect to determination of surgical approach based upon the ability to predict the orifice area and valvular anatomy. This report reviews our current experience with this technique. As well, the experience concerning the approach to each of the valvular conditions will also be reviewed with emphasis in respect to the left heart valves and particularly their long term postoperative management.

Adolescent↗

Two-dimensional echocardiographic method for the estimation of cardiac output independent of left ventricular geometry. Comparison with cardiac catheterization in mitral stenosis.

An hydraulic formula for the estimation of cardiac output independent of the geometric status of the left ventricle was studied by comparing the predictions based upon echographic and catheterization data with the results of the standard Fick principle method for cardiac output. The formula tested specifies cardiac output as Q = (1/21) RAT2, where Q is the cardiac output in ml, R is the heart rate, A is the mitral valve area in cm2 and T is the diastolic filling period in seconds per minute. Cardiac output estimated by this equation corresponds with cardiac output as determined by the Fick principle method at a level characterized by a correlation coefficient of r = 0.92 and a standard error of SE = 0.15 L/min for N = 26. The results suggest that the new expression may be useful for estimating cardiac output from echographic data.

Cardiac Catheterization↗

Early experience with the Sorin bileaflet prosthetic valve.

Between 1.6.1991 and 31.5.1995, 62 patients underwent heart valve replacement with Sorin Bicarbon bileaflet prosthetic valve, age 16-83 years (mean 60.5). The valve disease was rheumatic in 37 cases, degenerative in 17, congenital in 4 and miscellaneous etiologies in the other 4. The valve lesion was AS in 24 patients, AR in 5, AR+MS in 2, MS in 13, MR+MS in 6, MR in 6, tricuspid prosthetic stenosis in 1, A+M disease in 3, and a clotted prosthetic valve (Sorin disc) in 1. CAD was present in 14 patients (23%) and AF in 19 (31%). 11 had moderate pulmonary hypertension and 4 severe. Preoperatively 6 patients were in FC II, 40 in FC III and 16 in FC IV. Operative procedures included AVR 18, AVR+CABG 13, AVR+T annuloplasty 1, AVR and open M valvotomy 1, MVR 7, MVR+T annuloplasty 7, MVR+AVR (Medtronic) 1, MVR+AVR 1, TVR, prosthetic valve replacement 1, and MVR+CABG 1. Hospital mortality was 3 (4.8%) -- one due to ruptured A-V groove and two due to LoCO. Postoperative complications: LoCO necessitating IABP -- 3 patient; 3 transient CVA and 1 CVA with hemiplegia. One patient had aortic prosthetic valve endocarditis 18 months following the operation necessitating reoperation. Other cases were treated for positive blood cultures. One patient had CVA after anticoagulant were discontinued. 28 patients are in FC I, 22 in H, 4 in III and 1 in IV. 4 patients are lost to follow-up. These data suggest that the Sorin Bicarbon Prosthetic valve can be safely and effectively used for heart valve replacement.

Aortic Valve↗

[Elastic band ligation in secondary prevention of esophageal varices hemorrhage].

BACKGROUND: Sclerotization of esophageal varices may result in serious esophageal destruction. Elastic band ligation of esophageal varices is recently used in similar indications. AIM: The aim of the study was to evaluate in a pilot study the efficacy and safety of elastic band ligation for secondary prevention of bleeding from esophageal varices in patients who experienced life-threatening and were not yet treated with elastic band ligation. PATIENTS AND METHODS: Saeed's method of elastic band ligation was used in 10 patients (5 men and 5 women) aged from 16-60, who had already experienced life-threatening esophageal varices hemorrhage. One patient awaiting liver transplantation underwent preventive ligation. RESULTS: Esophageal varices were eradicated in 5 patients, minimum range residual varices remained in 4 patients after ligation. Haemorrhage recurrence was observed in 4 patients and was successfully treated by single urgent sclerotization. Two patients developed neo-varices. The ligation program was stopped in one female patient with mitral stenosis and tricuspidal insufficiency because of stenocardias occurring during ligation. In one session, 4.5 elastic bands in average were applied. The treatment of one patient required 4 sessions during 2.5 months in average. CONCLUSION: Elasic band ligation is an effective and safe method for the treatment of esophageal varices. Short term results are promising. (Tab. 1, Fig. 1, Ref. 18.)

Adolescent↗

Usefulness and limitations of precordial phonocardiography and external pulse recordings.

Phonocardiography provides one of a growing list of valuable intermediary studies between physical examination and cardiac catheterization. It not only provides a medium for instruction in physical examination, but also allows one to make certain diagnoses and assess severity of numerous cardiovascular lesions. It is especially valuable in the evaluation of all valvular stenoses, especially aortic stenosis. One can also use phonocardiography for screening and diagnosis of idiopathic hypertrophic subaortic stenosis. It is a helpful adjunct in the study of several congenital abnormalities as well as in the assessment of myocardial function in cardiomyopathies and ischemic heart disease, and may often be decisive in confirming the diagnosis of pericardial constriction.

Adolescent↗

[The surgical treatment of congenital valve disease].

The clinical results after surgical treatment of congenital valve disease have improved due to the use of several recently developed techniques. The replacement of tendinous cords using E-PTFE sutures has allowed the indications for the repair of mitral valve prolapse to be extended. The Ross procedure has made it possible to replace the aortic valve associated with small aortic annulus. However, replacement with a prosthetic valve remains the only option if repair is not possible or fails. Prosthetic valve replacement in the pediatric age-group remains challenging in patients with a small valve annulus. A number of techniques can be employed in such cases, including enlargement of the aortic annulus and translocation of the prosthetic valve in the left atrium, although there are limits on the size of the prosthesis. Further improvement of surgical techniques is necessary, along with the development of prosthetic valves using more nearly physiological materials.

Aortic Valve↗

[The influence of factor VII deficiency on cardiac operations with extracorporeal circulation].

During preoperative blood coagulation testing the factor VII (FVII) deficiency was found in two patients. No liver disease or cardiac insufficiency was found. No history of bleeding episodes existed. The latent (mild) deficiency of the FVII was diagnosed. The treatment with vitamin K (Vitacon) was administered in order to exclude vitamin K deficiency. The treatment showed no impact on the level of the FVII. Mixing study corrected the deficit (normal PT was found). Both patients underwent cardiac surgery with extracorporeal circulation. The epsilon-aminocapronic acid and fresh frozen plasma were used to prevent bleeding. The postoperative bleeding was compared to average of the year. No difference was found. The patients with mild FVII deficiency may safely undergo cardiac surgery with extracorporeal circulation.

Aged↗