Off-axis propagation of ultrasonic guided waves in thin orthotropic layers: theoretical analysis and dynamic holographic imaging measurement.

The elastic properties of many materials in sheet or plate form can be approximated with orthotropic symmetry. In many sheet material manufacturing industries (e.g., the paper industry), manufacturers desire knowledge of certain anisotropic elastic properties in the sheet for handling and quality issues. Ultrasonic wave propagation in plate materials forms a method to determine the anisotropic elastic properties in a nondestructive manner. This work explores exact and approximate analysis methods of ultrasonic guided wave propagation in thin layers, explicitly dealing with orthotropic symmetry and propagation off-axis with respect to the manufacturing direction. Recent advances in full-field ultrasonic imaging methods, based on dynamic holography, allow simultaneous measurement of the plate wave motion in all planar directions within a single image. Results from this laser ultrasonic imaging approach are presented that record the lowest anti-symmetric (flexural) mode wavefront in a single image without scanning. Specific numerical predictions for flexural wave propagation in two distinctly different types of paper are presented and compared with direct imaging measurements. Very good agreement is obtained for the lowest anti-symmetric plate mode using paper properties independently determined by a third party. Complete determination of the elastic modulus tensor for orthotropic layers requires measurement of other modes in addition to the lowest anti-symmetric. Theoretical predictions are presented for other guided wave modes [extensional (S), flexural (A), and shear-horizontal (SH)] in orthotropic plates with emphasis on propagation in all planar directions. It is shown that there are significant changes in the dispersion characterization of these modes at certain frequencies (including off-axis mode coupling) that can be exploited to measure additional in-plane elastic moduli of thin layers. At present, the sensitivity of the imaging measurement approach limits experimental investigation to relatively large amplitudes easily produced by flexural wave motion (> 0.1 nm). Extension of the measurement range and application to other plate wave modes are in progress and shall be reported in future work.

Journal Article↗

Design of advanced ultrasonic transducers for welding devices.

A new high frequency ultrasonic transducer has been conceived, designed, prototyped, and tested. In the design phase, an advanced approach was used and established. The method is based on an initial design estimate obtained with finite element method (FEM) simulations. The simulated ultrasonic transducers and resonators are then built and characterized experimentally through laser interferometry and electrical resonance spectra. The comparison of simulation results with experimental data allows the parameters of FEM models to be adjusted and optimized. The achieved FEM simulations exhibit a remarkably high predictive potential and allow full control of the vibration behavior of the transducer. The new transducer is mounted on a wire bonder with a flange whose special geometry was calculated by means of FEM simulations. This flange allows the transducer to be attached on the wire bonder, not only in longitudinal nodes, but also in radial nodes of the ultrasonic field excited in the horn. This leads to a total decoupling of the transducer to the wire bonder, which has not been achieved so far. The new approach to mount ultrasonic transducers on a welding device is of major importance, not only for wire bonding, but also for all high power ultrasound applications and has been patented.

Journal Article↗

Ultrasonically actuated silicon microprobes for cardiac signal recording.

In this paper, we report on ultrasonically actuated silicon thin microprobes that successfully penetrated canine cardiac tissue in vitro, and recorded the electrophysiological signals from multiple sites simultaneously within the heart wall. The penetration force--maximum force encountered by the probe during penetration--is found to reduce with increasing ultrasonic driving voltage, on both excised canine right ventricular muscle and chicken breast muscle. The rate of force decrease varies with tissue type and microprobe dimension. With ultrasonic actuation, the silicon microprobes are inserted into isolated perfused canine heart without breakage or significant buckling, under 10Vpp actuating voltage. Recordings were obtained from isolated perfused canine heart during pacing, following the induction of ventricular tachycardia, and during the transition from ventricular tachycardia to ventricular fibrillation. Local conduction velocity of 0.60 +/- 0.03 m/s was observed from the multichannel recordings from the canine right ventricular wall under epicardial pacing. The application of the ultrasonic microprobes in cardiac electrophysiology study can provide information for reconstruction of electrical wave propagation within the heart, which is important to understanding the mechanisms of cardiac arrhythmias.

Animals↗

MEMS ultrasonic transducers for the testing of solids.

Arrays of capacitive diaphragm ultrasonic transducers could potentially be used for non-destructive ultrasonic testing and structural monitoring. In this paper, we consider the efficiency of coupling of these transducers to solid media. We show that efficient coupling can be realized by using a silicone coating as a coupling medium. We present the results of experimental characterization of ultrasonic transducers coupled to solids in this way. We show that these transducers can be used with piezoelectric emitting transducers within the range from 1 to 5 MHz, and we demonstrate the use of several transducers as a phased array to determine the direction and distance of an ultrasonic source.

Acoustic Stimulation↗

Finite element simulation for a new disc-type ultrasonic stator.

This paper is concerned with the development of a new disc-type piezoelectric ultrasonic stator. Linear piezoelectric, mechanical, and piezoelectro-mechanic behaviors of a metal disc structure embedded with piezoelectric actuator are considered. Using a finite element method, a dynamic formulary is modeled for the new disc-type piezoelectric ultrasonic stator. In this model, a 3-dimensional (D) mechanical element with an extra electrical degree of freedom is used to simulate dynamic vibration modes and analyze characteristic responses such as electrical impedance response, phase response, and mechanical frequency response for a new disc-type piezoelectric ultrasonic stator. An adaptive boundary condition, simple support condition with three nonequal-triangular fixed points near the edge for the mechanism design of a new disc-type piezoelectric ultrasonic stator is defined so that a lateral elliptical motion of the contact point between stator and rotor can be realized for driving the rotor. The finite element results have been compared with the experimental measurements. As a result, the analysis model seems to be similar to the real condition.

Journal Article↗

Response of fiber Bragg gratings to longitudinal ultrasonic waves.

In the last years, fiber optic sensors have been widely exploited for several sensing applications, including static and dynamic strain measurements up to acoustic detection. Among these, fiber Bragg grating sensors have been indicated as the ideal candidate for practical structural health monitoring in light of their unique advantages over conventional sensing devices. Although this class of sensors has been successfully tested for static and low-frequency measurements, the identification of sensor performances for high-frequency detection, including acoustic emission and ultrasonic investigations, is required. To this aim, the analysis of feasibilty on the use of fiber Bragg grating sensors as ultrasonic detectors has been carried out. In particular, the response of fiber Bragg gratings subjected to the longitudinal ultrasonic (US) field has been theoretically and numerically investigated. Ultrasonic field interaction has been modeled, taking into account the direct deformation of the grating pitch combined with changes in local refractive index due to the elasto-optic effect. Numerical results, obtained for both uniform and Gaussian-apodized fiber Bragg gratings, show that the grating spectrum is strongly influenced by the US field in terms of shape and central wavelength. In particular, a key parameter affecting the grating response is the ratio between the US wavelength and the grating length. Normal operation characterized by changes in wavelength of undistorted Bragg peak is possible only for US wavelengths longer than the grating length. For US wavelengths approaching the grating length, the wavelength change is accompanied by subpeaks formation and main peak amplitude modulation. This effect can be attributed to the nonuniformity of the US perturbation along the grating length. At very high US frequencies, the grating is not sensitive any longer. The results of this analysis provide useful tools for the design of grating-based ultrasound sensors for meeting specific requirements in terms of field intensity and frequencies.

Journal Article↗

Blind multiridge detection for automatic nondestructive testing using ultrasonic signals.

Ultrasonic imaging has been a significant means for nondestructive testing (NDT). Recently the NDT techniques via the ultrasonic instrumentation have shown the striking capability of the quality control for the material fabrication industry. To the best of our knowledge, all existing signal processing methods require either the a priori information of the ultrasonic signature signals or the manual segmentation operation to achieve the reliable parameters that characterize the corresponding mechanical properties. In this paper, we first provide a general mathematical model for the ultrasonic signals collected by the pulse-echo sensors, then design a totally blind novel signal processing NDT technique relying on neither a priori signal information nor any manual effort. Based on the automatic selection of optimal frame sizes using a proposed new criterion in our scheme, the signature signal can be blindly extracted for further robust multiridge detection. The detected ridge information can be used to estimate the transmission and attenuation coefficients associated with any arbitrary material sample for the fabrication quality control.

Journal Article↗

Ultrasonic collection of small particles by a tapered metal strip.

A pi-shaped ultrasonic actuator can collect small particles by its two sharp edges. However, the collection of particles is weak in air and not very stable in water. In this paper, a refinement to the pi-shaped ultrasonic actuator is made for a more efficient collection of small particles in air and water. In the refined structure, an ultrasonic actuator with a metal strip is used to collect small particles. The metal strip is mechanically driven by one corner of a rectangular, sandwich-shaped ultrasonic transducer operating in the thickness mode vibration. The metal strip is tapered along its length and has a strong vibration at its tip. Small particles in air and water can be attracted to the radiation surface near the end of the metal strip. The dependence of the number of collected particles on driving frequency and voltage is investigated for shrimp eggs, mint seeds, and grass seeds. For a given driving voltage and particle type, the number of collected particles reaches a maximum value at some driving frequency. Increasing driving voltage increases this maximum number to some extent; but too large a driving voltage decreases it. The maximum number also depends on the weight per particle. It increases as the weight per particle decreases for the particles with close densities. Furthermore, the relationship between the number of collected particles and vibration amplitude at the end of the metal strip is investigated for shrimp eggs, mint seeds, and grass seeds. The number is approximately linearly proportional to the vibration amplitude when the vibration amplitude is not too large. In addition to the application in which the length of the metal strip is parallel to gravitation, the actuator also can be used with its length perpendicular to gravitation. However, the latter has a weaker capability of collecting small particles. It is also found that the actuator has a stronger capability to collect particles in water than in air.

Journal Article↗

Phased-ultrasonic receiving-planar array transducer for partial discharge location in transformer.

Partial discharge (PD) location in transformers is very important, and many methods that have been brought forward in past decades have a limitation theoretically, namely, they cannot locate multiple PDs in electrical equipment. In this paper, a new PD location method based on UHF and ultrasonic-phased arrays receiving theory has been presented, which has a possibility to locate multiple PDs. According to the method, a phased-ultrasonic receiving-planar array sensor that possesses 16 * 16 elements is designed; and, based on the phased-array theory, the characteristics of the plane sensor are studied. The laboratory experimental tests on the plane sensor element indicates that it has a good performance within the frequency band of the main ultrasonic energy produced by PD in transformer oil. Location tests are conducted on one or two piezoelectric ultrasonic sources in oil, which are both simulated as PD sources and triggered by an electrical pulse whose front is considered as a time benchmark in the locating algorithm. The test results show locations to one and two PDs can be realized in a single measurement, which lays a foundation for locating PDs in a power transformer in service.

Journal Article↗

Assessment of aging of the human skin by in vivo ultrasonic imaging.

The ultrasonic imaging technique that we have developed provides cross-sectional images of human skin in vivo with a resolution of about 80 microns axially (i.e., deep into the skin) and 250 microns lateral (parallel to the surface). In order to study aging skin, we obtained ultrasonic images from the mid-forearm (volar and dorsal sides) of 142 women. Ultrasonically, on the images, the dermis appears composed of two bands: a dark superficial one where the ultrasonic waves are propagated in a relatively homogeneous or non-echogenic medium, and a deeper one, which is lighter in color, suggesting a heterogeneous medium. Our results show that skin is thicker on the dorsal than on the volar forearm. In contrast to previously published results, skin thickness remains constant until the seventh decade of life, diminishing thereafter. The relative thickness of the two bands show marked variations with age: a progressive thickening of the dark band, from zero in infants to approximately 75% of total skin thickness in aged subjects, while the light band shows the inverse trend. Comparing the amplitude of the bands on the volar and dorsal forearm, the relative thickness of the dark band is larger on the dorsal (exposed) side and increases with age. These findings and the analysis of variously stained biopsies taken in some of our patients lead us to assign this dark band to a zone in the upper dermis where the collagen network is delicate, dense, and well organized. This is supported by some data in the literature. The thickness of this subepidermal non-echo-genic band appears to be a far more sensitive marker of skin aging at the dermal level than is the measurement of skin thickness.

Aging↗

Evaluating measurement variability in clinical investigations: the case of ultrasonic estimation of urinary bladder volume.

OBJECTIVE: To evaluate the quality of studies seeking to establish measurement properties (reliability and validity) of ultrasonic estimation of urinary bladder volume. DESIGN: Online searching of the MEDLINE database between 1966 and 1995, and scanning of bibliography of known studies on ultrasonic bladder volume estimation. Study selection and study quality assessment were performed independently by two reviewers. Each article was evaluated for suitability of the reference standard, adequacy of reported blinding of the observers and appropriateness of the statistical index of concordance. The last two of these guidelines were applied to reliability studies (evaluating the relation among observed ultrasonic estimations), and all three guidelines were applied to validity studies (evaluating the relation of ultrasonic estimation with a definitive measurement). POPULATION: One hundred and twenty-five participants enrolled in the five reliability studies and 769 participants in the 27 validity studies selected for appraisal of their quality. MAIN OUTCOME MEASURE: Rate of study compliance with preset criteria for high quality. RESULTS: None of the studies complied with all of the criteria for high methodologic quality. In the five reliability studies, investigators did not report adequate blinding of observers in three (60%) and an appropriate index of reliability was not used in any. Among the 27 validity studies, there was a lack of a suitable reference standard in 6 (22%), an inadequate blinding in 25 (93%), and an inappropriate index of validity in all (100%). CONCLUSION: Based on our guidelines for quality assessment, a large proportion of studies on measurement properties was found to have inadequate methods, raising concern about the credibility of the reliability and validity estimates reported. These deficiencies highlight the lack of rigour employed in the design, conduct and analysis of reliability and validity studies, which has the potential for leading to patient mismanagement due to biases in the assessment of measurement variability in clinical investigations.

Humans↗

Ultrasonic tissue characterization of normal and ischemic myocardium.

Cardiac ultrasonic tissue characterization is designed to use the alterations in acoustic signals from the myocardium to differentiate normal from ischemic or infarcted tissue due to their characteristic backscatter attenuation. Various approaches such as use of a gray scale, color display, or quantitative image analysis have been used for tissue characterization, but all depend on subjective assessments and are not necessarily reproducible. The most promising method has been the use of "raw" radiofrequency signals and measure changes in the ultrasonic attenuation with an index of backscatter to distinguish normal from abnormal myocardium called "integrated backscatter" (IB). Various studies have demonstrated the changes in the ultrasonic backscatter with ischemia or infarction. In this review we summarize our experience with a research prototype instrument in tissue characterization and differentiation of normal, ischemic, infarcted, and post ischemic reperfused myocardium in anesthetized open chest dogs. Currently we are investigating the role of ultrasonic tissue characterization to estimate infarct size and plan to apply these observations to patients in order to detect viable myocardium and quantitate infarct size.

Animals↗

Ultrasonic characterization of biological tissues.

Ultrasonic imaging has become increasingly important as a diagnostic tool in medicine because it is noninvasive and it can provide valuable information otherwise unattainable. However, at present, clinical interpretation of an ultrasonic image still mostly relies on recognition of boundaries and positional relationship of anatomical structures and a subjective analysis of the distribution or texture of echo amplitudes. Other potentially useful information carried back by the echoes is completely discarded. The aim of ultrasonic tissue characterization research is to develop methods to extract additional information from the returned echoes so that tissue pathology or abnormality can be reliably identifed and severity of the pathology objectively assessed with quantitative criteria. A number of ultrasonic parameters including acoustic velocity, impedance, attentuation and scattering, have been utilized in attempting to achieve this goal. In this paper, recent progress in this research will be discussed and relevant results presented.

Acoustics↗

Hybrid laser/broadband EMAT ultrasonic system for characterizing cracks in metals.

Detection and characterization of defects in metal parts in industrial and commercial settings has typically been carried out by nondestructive ultrasonic inspection systems. Correct measurement of crack size is critical for lifetime prediction inspections. Normally, measurements are made based on far-field ultrasonic diffraction models and time-of-flight reflection signals making accurate measurements for parts less than approximately 25 mm in thickness impossible. In this work a hybrid noncontacting laser generation/broadband electromagnetic acoustic transducer (EMAT) detection system is used to characterize ideal cracks in aluminum in which the far-field condition for ultrasonic diffraction cannot be met. Time domain signals show that diffracted energy is measured in the geometrical shadow zone of the crack. Fourier transform methods are used to show that the frequency content of the diffracted signals is different than those from the waves that do not interact with the crack. Crack size measurements are made by using the frequency content of the ultrasonic signal rather than time-of-flight information.

Journal Article↗

Influence of ultrasonic frequency on multibubble sonoluminescence.

Computer simulations of bubble oscillations are performed under conditions of multibubble sonoluminescence (MBSL) in water for various ultrasonic frequencies. The range of the ambient bubble radius for sonoluminescing bubbles narrows as the ultrasonic frequency increases; at 20 kHz it is 0.1-100 microm while at 1 MHz it is 0.1-3 microm. At 1 MHz, any sonoluminescing bubble disintegrates into a mass of smaller bubbles in a few or a few tens of acoustic cycles, while at 20 kHz and 140 kHz some sonoluminescing bubbles are shape stable. The mechanism of the light emission also depends on the ultrasonic frequency. As the ultrasonic frequency increases, the amount of water vapor trapped inside bubbles at the collapse decreases. As a result, MBSL originates mainly in plasma emissions at 1 MHz while it originates in chemiluminescence of OH radicals and plasma emissions at 20 kHz.

Journal Article↗

Applications of laser-based ultrasonics to the characterization of the internal structure of teeth.

Dental health care and research workers require a means of imaging the structures within teeth in vivo. For example, there is a need to image the margins of a restoration for the detection of poor bonding or voids between the restorative material and the dentin. In addition, a high-resolution imaging modality is needed to detect tooth decay in its early stages. If decay can be detected early enough, the process can be monitored and interventional procedures, such as fluoride washes and controlled diet, can be initiated to help remineralize the tooth. Currently employed x-ray imaging is limited in its ability to visualize interfaces and incapable of detecting decay at a stage early enough to avoid invasive cavity preparation followed by a restoration. To this end, nondestructive and noncontact in vitro measurements on "as-is" extracted sections of human incisors and molars using laser-based ultrasonics are presented. Broadband ultrasonic waves are excited in the extracted sections by using a pulsed carbon-dioxide (CO2) laser operating in a region of high optical absorption in the dental hard tissues. Optical interferometric detection of the ultrasonic wave surface displacements is accomplished with a path-stabilized Michelson-type interferometer. Laser ultrasonics is found effective in characterizing the anisotropic and inhomogeneous nature of dentin. In addition, time-of-flight analysis of the measured bulk transmission waveforms allows for detection of dentino-enamel and carious dentin-dentin junctions. These results are compared to those obtained for specially prepared tooth phantoms that mimic the mechanical properties of dental hard tissues.

Anisotropy↗

Determination of transport parameters in air-saturated porous materials via reflected ultrasonic waves.

An ultrasonic reflectivity method of evaluating the acoustic parameters of porous materials saturated by air (or any other gas) is discussed. The method is based on experimental detection of waves reflected at normal incidence by the first and second interface of the material. This method is based on a temporal model of direct and inverse scattering problems for the propagation of transient ultrasonic waves in a homogeneous isotropic slab of porous material with a rigid frame [Fellah et al., J. Acoust. Soc. Am. 113, 61-73 (2003)]. Generally, the conventional ultrasonic approach can be used to determine tortuosity, and viscous and thermal characteristic lengths via transmitted waves. Porosity cannot be estimated in transmitted mode because of its very weak sensitivity. First interface use of the reflected wave at oblique incidence leads to the determination of porosity and tortuosity [Fellah et al., J. Acoust. Soc. Am. 113, 2424-2433 (2003)] but this is not possible at normal incidence. Using experimental data of reflected waves by the first and second interface at normal incidence simultaneously leads to the determination of porosity, tortuosity, viscous and thermal characteristic lengths. As with the classic ultrasonic approach for characterizing porous material saturated with one gas, both characteristic lengths are estimated individually by assuming a given ratio between them. Tests are performed using weakly resistive industrial plastic foams. Experimental and numerical results, and prospects are discussed.

Journal Article↗

Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentration.

Earlier studies showed that ultrasonic backscatter from erythrocytes suspended in saline is a function of hematocrit and frequency and that it can be affected by flow disturbance. The experimental data agree well with the theories. Recently, studies have been extended to flowing whole blood. The results indicated that ultrasonic backscatter from flowing whole blood differs from that from saline suspensions of erythrocytes in that it is shear-rate dependent and species dependent. In the present article, data on the dependence of ultrasonic backscatter from flowing whole blood on frequency and on fibrinogen concentration are reported. It was found that ultrasonic backscatter from flowing whole blood also depends on fibrinogen concentration when red blood cell (RBC) aggregation exists. Moreover, when the blood is under conditions that favor RBC aggregation such as low shear rates, high fibrinogen concentration, or high hematocrits, Rayleigh scattering apparently is no longer sufficient to describe its scattering behavior.

Animals↗