PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Modifications of surface properties in some enteropathogenic serogroups of Escherichia coli.

Studies have been carried out on protein and fatty acid patterns present in the outer layers of E. coli strains which are considered pathogenic in relation to their serogroup. The patterns were related to surface properties of hydrophobicity of the same cells and to their resistance to phagocytosis. The results obtained demonstrate the presence in the pathogenic serogroups of a proteic band of high molecular weight as well as differences in the percentages of fatty acids with respect to the non-pathogenic serogroups. Furthermore, these serogroups are more resistant to phagocytosis; this resistance seems to be correlated to a greater surface hydrophilia of the pathogenic serogroups, leading to different relations of the lipidic and protein fraction of the outer layers.

Bacterial Outer Membrane Proteins↗

[Study on the color modification buring surface staining of PLAT castable ceramic restorations].

The surface staining of castable ceramic restorations is a technique-dependent process. So it is inevitable that the color of restorations mismatch the color of natural teeth. This study was conducted to explore the possibility of modifying the color by selected use of special colored stains. Eighty PLAT castable ceramic samples were machined, 16 mm in diameter, 1.2 mm in thickness. Thirty-two samples were stained with yellow stain and 32 samples orange. Sixteen samples were stained with red, green, blue and violet stains, respectively. To the yellow and orange stained samples, we applied correspondingly the same stain, red, green, blue and violet stains. The color of each sample was evaluated with a colorimeter and translated to Munsell notations. The results indicated that chroma was intensified by each application of the same stain. Red and green stains made the hue reddish and greenish. Blue and violet stains could effectively decrease the chroma of yellow or orange. Meanwhile, the hue was also slightly changed to greenish and reddish.

Ceramics↗

Evaluation of collagen modification and surface properties of a bovine artery via polyepoxy compound fixation.

Collagen of bovine internal thoracic artery (BITA) was treated with glutaraldehyde (GA) or polyepoxy compounds (PC). This study was to evaluate the surface properties as a result of tissue tanning reaction with PC. The fixation resulted in a significant reduction of available lysine, histidine, and other amino acid residues in PC fixed grafts as compared to fresh pre-fixed arteries. Among them, the lysine (Lys) content was reduced by about 80%, indicating that PC reactions mainly involve with Lys residues. Both PC and GA treatment led to crosslinking as evidenced by the increase in the denaturation temperature. The critical surface tension and the Fourier Transform Infrared Spectrum (FTIR) on a pre-implant and its 96 days explant were evaluated and found to be similar. The FTIR analysis of a pre-implant and the 96 day explant indicated that there was no lipid deposition.

Amino Acids↗

Hydrothermal modification of titanium surface in calcium solutions.

Hydrothermal modification of a titanium surface in calcium solutions was performed. The apatite precipitation on the modified surface in Hanks' solution, as a simulated body fluid, was evaluated and the surface microstructure changes after the modification were characterized by thin-film X-ray diffractometry (TF-XRD) and X-ray photoelectron spectroscopy (XPS). Hydrothermal modification in CaO solution enhanced the precipitation of apatite on the titanium surface. High pH, high pressure and high temperature of the CaO solution increased the thickness of the surface-modified layer and enhanced the synthesis of calcium titanate which possibly promoted the precipitation of apatite in Hanks' solution. Hydrothermal modification in CaCl2 solution, on the other hand, showed reverse effects. The modification of titanium in CaO solution with hydrothermal treatment is expected to result in excellent osteointegration and can be easily performed by using an autoclave, a clinical apparatus widely used.

Apatites↗

Attachment and proliferation of neonatal rat calvarial osteoblasts on Ti6Al4V: effect of surface chemistries of the alloy.

This study examined the cell attachment and proliferation of neonatal rat calvarial osteoblasts on Ti6Al4V alloy as affected by the surface modifications. The modifications could alter simultaneously the surface chemistries of the alloy (elemental difference of Ti, Al, V, Cu and Ni about 300-600mum thick examined by EDS) as well as the XPS nano-surface characteristics of oxides on the metal surface (chemistries of oxides, amphoteric OH group adsorbed on oxides, and oxide thickness). Three materials including two from modifications and a control were examined. It is argued that a slight change of the nano-surface characteristics of oxides as a result of the modifications neither alters the in vitro capability of Ca and P ion adsorption nor affects the metal ion dissolution behavior of the alloy. This implies that any influence on the cytocompatibility of the materials should only be correlated to the effect of surface chemistries of the alloy and the associated metal ion dissolution behavior of the alloy. The experimental results suggest that the cell response of neonatal rat calvarial osteoblasts on the Ti6Al4V alloy should neither be affected by the variation of surface chemistries of the alloy in a range studied.

Alloys↗

Influence of surface self-modification in Ringer's solution on the passive behavior of titanium.

The influence of the spontaneous surface modification of titanium by exposure to Ringer's solution at open-circuit conditions on the passive behavior was studied. The electrochemical behavior of Ti was compared in a simple NaCl and in Ringer's physiological solution. Potentiodynamic polarization curves show significantly higher passive current densities in Ringer's solution as compared with the simple saline solution. Furthermore, impedance spectra measured at the open-circuit potential as a function of time indicate that in saline solution a long-term exposure over some days leads to a strong increase of the protectiveness of the passive film. This improvement of the passive behavior cannot be observed in Ringer's solution, but a strong modification of the passive film/electrolyte interface can be seen in the impedance spectra. The changes in the impedance spectra can be correlated with the results observed by surface characterization regarding the morphology (scanning electron microscopy) and chemical composition of the surface (X-ray photoelectron spectroscopy). In agreement with previous work by others, a spontaneous modification of the surface of Ti by Ca and P species was observed. The composition of the Ca/P precipitates changes as a function of time, indicating a slow formation of a hydroxyapatite-like deposit layer on the surface. The results of the present work indicate that the formation of the outer Ca-P deposit layer on the passive Ti surface (which is beneficial for the biological performance) hinders the normal aging of the passive TiO(2). Even though the protectiveness of the passive film can be considered as high also in Ringer's solution, significantly higher passive dissolution rates (i.e., higher metal-ion release) for Ti exposed to Ringer's solution can be expected as compared with a simple saline solution.

Electrochemistry↗

Synthesis and characterization of surface-hydrophobic ion-exchange microspheres and the effect of coating on drug release rate.

Biodegradable, dextran-based ion-exchange microspheres (IE-MS) have been used for localized delivery of anticancer drugs and chemosensitizers. Because of their hydrophilic nature, the IE-MS release their payload quickly. The purpose of this work was to develop an IE-MS system that could provide a broad range of release rates for in vitro and in vivo applications. Sulfopropylated dextran microspheres (SP C25 MS) were surface-modified by acylation. These hydrophobically modified sulfopropylated dextran microspheres (HM-MS) were further coated with the cationic acrylic polymer Eudragit RL100 (EU-MS). The changes in chemical composition after the surface modification and coating were characterized by X-ray photoelectron spectroscopy. The effects of the modification and coating on the surface hydrophobicity, equilibrium swelling, surface morphology, and drug loading capacity were investigated. The HM-MS showed little change in swelling and functionality, despite significantly increased affinity to oil and carbon content on the surface. The coated microspheres (EU-MS) exhibited a profoundly decreased swelling ratio, an even higher affinity to oil, a higher loading capacity, and a lower drug release rate. Through further coating of the EU-MS with different amounts of corn oil, the rate of drug release could be tailored to cover a relatively wide range. These results suggest that a versatile delivery system with various release profiles can be prepared by a combination of hydrophobic modification, polymer coating, and oil coating.

Ion Exchange Resins↗

Mechanisms of heparin transport through expanded poly(tetrafluoroethylene) vascular grafts.

Thrombosis and neointimal hyperplasia limit the utility of small-caliber artificial vascular grafts. Surface modifications and adjunctive pharmacological therapy might mediate these complications. We examined the mechanisms by which a model vasoactive compound, heparin, transverses porous graft materials and how material modifications alters this drug's transport. The effective permeance of [(3)H]heparin was measured after application of a uniform concentration of drug to either the internal or external surface of the graft and in the presence or absence of pressure-driven physiologic hydraulic flows. Transgraft permeance was equivalent to those observed in normal arteries and, while enhanced by convection, was mediated in major part by diffusion. Peclet numbers under the various conditions examined ranged from 0.05 to 1.2, indicating that diffusive forces were equal to or exceeded convective forces in governing transmural heparin motion. Heparin traversed the graft even when applied from the outer perivascular surface, against adverse hydraulic flows. Modifications of the grafts that included a yarn barrier of spun poly(tetrafluoroethylene) or chemical modification of surface tension energy altered permeances as well. A unifying model for interpretation of these data incorporates the concept of entrapped air and surface tension energy in the graft. These characterizations allow for the design of vascular grafts that are optimized for pharmacotherapy to help prolong graft patency, especially in small-caliber vascular beds.

Air↗

Characterization of surface modified Ti-6Al-7Nb alloy.

In the last years different types of surface modifications were developed with the aim of improving the osteointegration ability of titanium alloys. The chemical composition, crystallographic structure and morphology of a surface layer can be modified in order to obtain a better interaction between the implant, the cells and the organic fluids. The final goal is to obtain a more efficient bone growth also in critical clinical cases. In the present paper were reported several data about the characterization of the Ti-6Al-7Nb alloy treated by two innovative surface treatments. They consist of blasting, followed by a two step chemical etching and heat treatment performed in air or in vacuum. TEM, XRD and SEM investigations were performed in order to assess the structure and morphology of the modified surfaces. The surface chemical composition was investigated by XPS ad AES analyses. The ability to interact with physiological fluids was tested by immersion of the treated materials in an acellular simulated body fluid (SBF). Metal ion concentration analyses of the fluid and SEM observations of the samples were performed after different times of soaking. The mechanical characterization involved scratch and fatigue tests. The surface of treated samples shows chemical, structural and morphological modifications. The passivation pre-treatment has influence on the surface modification. The treated samples evidenced a quite low metal ion release and interact with SBF solution, showing a moderate bioactivity. A relevant decrease in fatigue strength was observed on modified samples.

Aluminum↗

Lectin-binding sites on human sperm during acrosome reaction: modifications judged by electron microscopy/flow cytometry.

Biochemical surface modifications occur during the capacitation and acrosome reaction of human sperm and among those, variations in the expression of carbohydrates moieties. A sequential study was performed with electronic microscopy and flow cytometry techniques, where the binding of 4 lectins was assessed on normal human sperm samples during in vitro induction of the acrosome reaction with calcium ionophore A-23187. Triticum vulgaris agglutinin (WGA) was shown to bind strongly the whole surface of sperm before induction of the acrosome reaction, and in lesser amounts after incubation with calcium ionophore. Arachis hypogea agglutinin (PNA) and mostly Concanavalia ensiformis agglutinin (Con-A) and Ulex europaeus agglutinin (UEA-1) binding evolved in an opposite pattern with an increase of the labeling parallel to that of GB24 antibody binding. Electron microscopy showed that the fluorescence patterns observed correlated with increased access to the inner membrane of the acrosome. This was significant 60 min after the induction of acrosome reaction. Lectin binding could be a useful tool to examine the ability of sperm samples to undergo the acrosome reaction.

Acrosome↗

Size-selective protein adsorption to polystyrene surfaces by self-assembled grafted poly(ethylene glycols) with varied chain lengths.

We report about the surface modification of polystyrene (PSt) with photoreactive alpha-4-azidobenzoyl-omega-methoxy poly(ethylene glycol)s (ABMPEG) of three different molecular weights (MWs of approximately 2, approximately 5, and approximately 10 kg/mol) and with two poly(ethylene glycol)/poly(propylene glycol) triblock copolymers (PEG-PPG-PEG) of about identical PEG/PPG ratio (80/20, w/w) and MW(PEG) of approximately 3 and approximately 6 kg/mol, all via adsorption from aqueous solutions. For ABMPEGs, an additional UV irradiation was used for photografting to the PSt. Contact angle (CA) and atomic force microscopy data revealed pronounced differences of the hydrophilicity/hydrophobicity and topography of the surfaces as a function of PEG type and concentration used for the modification. In all cases, an incomplete coverage of the PSt was observed even after modification at the highest solution concentrations (10 g/L). However, clear differences were seen between PEG-PPG-PEGs and ABMPEGs; only for the latter was a nanoscale-ordered interphase structure with an influence of MW(PEG) on the PEG density observed; after modification at the same solution concentrations, the density was significantly higher for lower MW(PEG). The adsorption of three proteins, myoglobin (Mgb), bovine serum albumin (BSA), and fibrinogen to the various surfaces was analyzed by surface plasmon resonance. Pronounced differences between the two PEG types with respect to the reduction of protein adsorption were found. At high, but still incomplete, surface coverage and similar CA, the shielding of ABMPEG layers toward the adsorption of Mgb and BSA was much more efficient; e.g., the adsorbed Mgb mass relative to that of unmodified PSt was reduced to 10% for ABMPEG 2 kg/mol while for both PEG-PPG-PEGs the Mgb mass was still around 100%. In addition, for the ABMPEG layers an effect of MW(PEG) on adsorbed protein mass-decrease with decreasing MW-could be confirmed; and the highest Mgb/BSA selectivities were also observed. A "two-dimensional molecular sieving", based on PEG molecules having a nanoscale order at the hydrophobic substrate polymer surface has been proposed, and the main prerequisites were the use of PEG conjugates which are suitable for an "end-on" grafting (e.g., ABMPEGs), the use of suitable (not too high) concentrations for the surface modification via adsorption/self-assembly, optionally the photografting on the substrate (possible only for ABMPEG), and presumably, a washing step to remove the excess of unbound PEGs. The results of this study also strongly support the hypothesis that the biocompatibility of hydrophobic materials can be very much improved by PEG modifications at surface coverages that are incomplete but have an ordered layer structure controlled by the size and steric interactions of surface-bound PEGs.

Adsorption↗

Atomic-scale scanning tunneling microscopy study of plasma-oxidized ultrahigh-modulus carbon fiber surfaces.

In the present work, scanning tunneling microscopy (STM) was employed to study the surface modification of ultrahigh modulus carbon fibers at the atomic level by oxygen plasma. As detected by STM, the distinctive feature of the fresh, untreated surface was the general presence of atomic-scale arrangements in different degrees of order (from atomic-sized spots without a clearly ordered disposition to triangular patterns identical to those typical of perfect graphite). Following fiber exposure to the plasma, the STM images showed evidence of the abstraction of carbon atoms from random locations on the fiber surface, giving rise to the development of defects (i.e., structural disorder), which in turn were the places where oxygen could be introduced during and after the plasma etching. It was observed that the most effective treatments in terms of extent of surface structural modification (disordering) and uniform introduction of oxygen were those carried out for just a few ( approximately 3) minutes. Considerably shorter exposures failed to provide a homogeneous modification and many locations on the fiber surface remained unaltered, retaining their original atomic-scale order, whereas longer treatments did not bring about further structural changes to the surface and only led to fiber consumption. These results are consistent with previous X-ray photoelectron spectroscopy measurements on these fibers and provide an atomic-level understanding of the saturation effect observed in the surface oxygen concentration of this and other types of carbon fibers with plasma oxidation. Such understanding may also prove helpful for the accurate control and optimization of fiber-matrix interaction in composite materials.

Journal Article↗

The surface treatment of polypropylene molds and its effect on the quality of cast contact lenses.

An investigation of the surface by XPS photoelectron spectroscopy has shown that the process of production of cast contact lenses based on poly(2-hydroxyethyl methacrylate-co-diethyleneglycol methacrylate) is accompanied by mass transfer at the lens-mold boundary. This phenomenon, which impairs the compatibility of the lens during its application, can be considerably suppressed by employing a suitable surface modification of polypropylene molds. The surface treatment consisting in the oxidation of the mold surface by an AC corona discharge in the oxygen atmosphere increases hydrophilicity of the material, thus facilitating separation of the lens from the mold. The results of the XPS study were also confirmed microscopically by employing the SEM method.

Contact Lenses, Hydrophilic↗

Surface characteristics and properties of lumbrokinase-immobilized polyurethane.

Potent and novel fibrinolytic enzymes (lumbrokinase [LK]) were extracted from the earthworm, Lumbricus rubellus. These enzymes were very stable and showed greater antithrombotic activity than other currently used fibrinolytic proteins. An LK fraction showing the most potent fibrinolytic activity was immobilized onto a polyurethane (PU) surface to investigate its enzymatic activity and antithrombotic activity. A methanol-extracted PU surface was coated with 3% (wt/vol) maleic anhydride methylvinyl ether copolymer (MAMEC)/tetrahydrofuran (THF) solution, and the surface was incubated in an LK solution/phosphate-buffered saline (PBS, pH 7.4). The surface properties were characterized by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), electron spectroscopy for chemical analysis (ESCA), and dynamic contact angle. The stability of immobilized LK was determined by caseinolytic activity assay and the specificity of immobilized LK on fibrinogen/fibrin was observed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). The antithrombotic activity of immobilized LK was evaluated using an ex vivo rabbit A-A shunt experiment. LK immobilization was confirmed by ATR-FTIR and ESCA. Immobilized LK demonstrated stable proteolytic activity during various incubation periods. Immobilized LK proteolyzed fibrinogen and fibrin almost specifically, while it hardly hydrolyzed other plasma proteins including plasminogen and albumin. In the ex vivo A-A shunt experiment, the LK-immobilized surface significantly prolonged occlusion time over control surfaces. This is primarily due to the high thrombolytic activity of immobilized LK. In this work, a highly efficient surface modification method on the PU surface was developed, and this LK immobilization technique will be very useful in improving the blood compatibility of blood-contacting devices.

Animals↗