Glistenings in foldable intraocular lenses.

PURPOSE: To evaluate the formation of glistenings in foldable intraocular lenses (IOLs) of various materials after cataract surgery. SETTING: University Eye Clinic of Trieste, Trieste, Italy. METHODS: In this prospective study, 273 patients were randomized to have implantation of 1 of 7 types of foldable IOLs in the capsular bag after phacoemulsification. The IOLs were the CeeOn Edge 911A (Pharmacia & Upjohn Co.), ACR6D (Corneal), AcrySof (Alcon), SI-40NB (AMO), Hydroview H60M (Storz), Sensar (AMO), and Stabibag (Ioltech). The presence of glistenings in the IOL optic was assessed by slitlamp evaluation 7, 30, 90, 180, 360, and 720 days after surgery. The glistenings were graded at each control. RESULTS: Glistenings were observed in all IOL groups. The percentage of patients with glistenings ranged from 40.0% to 67.5%, with the percentage increasing up to 90 days after surgery and then becoming stable in most groups. The AcrySof group had a continuous increase over time. The mean grade of glistenings increased up to 180 days after surgery and then became stable in most groups. The AcrySof and 911A groups had a continuous increase over time. CONCLUSIONS: Glistening formation was observed in 7 different foldable IOLs. The AcrySof group had a higher percentage and a greater density of glistenings.

Acrylic Resins↗

Uveal and capsular biocompatibility of 2 foldable acrylic intraocular lenses in patients with uveitis or pseudoexfoliation syndrome: comparison to a control group.

PURPOSE: To evaluate the uveal and capsular biocompatibility of hydrophilic acrylic (Hydroview) and hydrophobic acrylic (AcrySof) intraocular lenses (IOLs) after phacoemulsification in eyes with pseudoexfoliation syndrome (PEX) or uveitis and compare the results with those in a control group. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective nonrandomized comparative trial comprised 143 eyes recruited consecutively. Of these, 49 eyes had PEX, 43 had uveitis, and 51 served as controls. A standardized surgical protocol was used. Cell reaction, anterior (ACO) and posterior (PCO) capsule opacification, and flare were evaluated 1 year after cataract surgery. RESULTS: Regarding uveal biocompatibility, the number of foreign-body giant cells (FBGCs) increased in proportion to associated ocular pathologies in both IOL groups. The difference between the Hydroview control and Hydroview uveitis groups was statistically significant. The number of FBGCs was greater on AcrySof IOLs than on Hydroview IOLs in all 3 groups. The difference in FBGCs between the 2 IOL types was statistically significant in the control and PEX groups. Regarding capsular biocompatibility, lens epithelial cell (LEC) outgrowth was inversely correlated with intraocular inflammation. Outgrowth was statistically significantly higher with Hydroview IOLs, occurring in 85% in the control group, 45% in the PEX group, and 28% in the uveitis group (P <.0001). With AcrySof lenses, the percentages were 0%, 8%, and 4%, respectively. The PEX and uveitis groups were more likely to develop ACO than the control group (P <.012). There was no statistically significant difference in ACO between the 2 IOL types in the 3 patient groups. The PCO was statistically significantly greater in the uveitis group than in the control group (P <.026) and statistically significantly more dense on Hydroview than on AcrySof IOLs in all 3 patient groups (P <.002). Flare was statistically significantly higher in the uveitis group than in the PEX and control groups with both IOL types (P <.012). There was no statistically significant difference in flare between the 2 IOL types. CONCLUSIONS: Uveal and capsular biocompatibility depends on the intensity of ocular inflammation. The greater the inflammation, the less the biocompatibility of hydrophilic and hydrophobic acrylic materials. AcrySof stimulated more FBGCs. The Hydroview material had better uveal but poorer capsular biocompatibility than AcrySof. The sharp optic edge effect of the AcrySof IOL and the advantages of the Hydroview lens in normal eyes are less apparent in compromised eyes.

Acrylic Resins↗

Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification.

PURPOSE: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Sensar OptiEdge AR40e intraocular lens (IOL) (Allergan Surgical) with that of the round-edged design of the Sensar AR40 IOL. Setting Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized patient- and examiner-masked study comprised 106 eyes of 53 patients with bilateral age-related cataract. Each patient had cataract surgery in both eyes and received an AR40 IOL in 1 eye and an AR40e IOL in the other eye. Postoperative examinations were at 1 week, 2 and 6 months, and 1 year. Digital slitlamp and digital retroillumination images of each eye were taken. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software. RESULTS: The AR40e group had significantly less regeneratory and fibrotic PCO 1 year after surgery. The mean automated image-analysis software PCO score (scale 0 to 10) was 2.19 in the AR40 group and 1.10 in the AR40e group (P <.001). The AR40e group had less peripheral fibrotic PCO. There was no significant difference in patient-reported edge glare between the 2 IOL groups. CONCLUSIONS: The sharp-edged design of the Sensar OptiEdge AR40e IOL led to significantly less PCO than the round-edged AR40 IOL 1 year postoperatively.

Acrylic Resins↗

Bag-in-the-lens implantation of intraocular lenses.

PURPOSE: To report a new intraocular lens (IOL) and an IOL implantation concept, the bag-in-the-lens implantation technique, designed to prevent posterior capsule opacification (PCO). SETTING: The University of Antwerp, Department of Ophthalmology, Edegem, Belgium, and the Netherlands Ophthalmic Research Institute, Department of Morphology, Amsterdam, The Netherlands. METHODS: After identical curvilinear capsulorhexes are created in both the anterior and posterior capsules, the capsules are inserted in a flange of the IOL, thus the term bag-in-the-lensas opposed to the currently used lens-in-the-bagtechnique. The IOL was implanted in an in vitro human capsular bag model and in 10 eyes of 9 patients with cataract. Lens epithelial cell (LEC) outgrowth and PCO formation were observed. RESULTS: When both capsular blades were well stretched around the IOL optic, the in vitro capsular bag model showed LEC proliferation only within the space of the remaining lens bag. The LEC proliferation was limited, and there was no tendency toward proliferation approaching the visual axis. In all 10 eyes, the optical axis remained clear during a follow-up between 4 and 15 months. CONCLUSIONS: This new IOL prevented LEC proliferation in vitro and seems promising in vivo. Target patients are those at risk of PCO including those with congenital cataract, uveitis, diabetes, or cataract extraction combined with vitrectomy.

Adolescent↗

Clinical performance of Alcon SA30AL and SA60AT single-piece acrylic intraocular lenses.

PURPOSE: To report the clinical performance characteristics of single-piece acrylic Alcon SA30AL and SA60AT intraocular lenses (IOLs). SETTING: A private practice in Marshalltown, Iowa, USA. METHODS: In a review of 2630 consecutive cases operated on from January 2000 through July 2001, ease of IOL insertion and integrity of the haptic architecture were evaluated in a prospective fashion at implantation. Subgroups of cases were studied prospectively to evaluate 3 factors: same-day incision competence after implantation (postoperative intraoperative pressure [IOP], 107 cases); 2- to 5-week A-constant validation (200 cases); 1-day, 2-week, and 1- and 5-month descriptions of optic centration with respect to pupil and capsule anatomy (79 cases); and a 1-day versus 9-month photographic comparison of IOL centration (70 cases). A retrospective evaluation of the population's diagnostic codes tabulated complications including increased postoperative iritis, cystoid macular edema, neodymium:YAG (Nd:YAG) laser intervention for posterior capsule opacification, and pseudophakic dysphotopsia. A retrospective review of a subgroup of 140 consecutive cases was done to categorize postoperative optic clarity. RESULTS: Overall, the IOLs were easy to implant with no haptic or optic damage using a forceps or the Monarch injector. Subgroup studies confirmed good performance in the following parameters: There were no cases of incision incompetence evidenced by an abnormally low postoperative IOP. The lowest postoperative IOP was 6 mm Hg, with the overall mean IOP increasing to 29 mm Hg from the 17 mm Hg measured a mean of 102 minutes after surgery. The manufacturer's published A-constant was almost identical to that obtained in review (118.4 versus 118.38 for the SA30AL and 118.35 for the SA60AT). In verbal descriptions, IOL optic centration was assessed to be within 0.4 mm of perfect in 75 (95%) of 79 cases. Slitlamp photographs showed that 52 (98%) of 53 IOLs were in the same position 9 months after surgery as on the day of surgery. One IOL optic appeared to rotate 14 degrees. There were no cases of decentration greater than 1.0 mm in either optic centration subgroup. Given a normal postoperative topical steroid regimen, there were no cases of substantially increased or prolonged iritis. There were 17 cases (0.65%) of macular edema. An Nd:YAG laser posterior capsulotomy was performed in 0.64% (13/2044) in the SA30AL group over a mean of 9 months (range 2 to 23 months) and in 0.34% (2/586) in the SA60AL group over a mean of 5.5 months (range 5 to 6 months). Pseudophakic dysphotopsia was diagnosed in 26 eyes of 18 patients (1% of 2630 cases), with 1 patient requiring an IOL exchange. Optic glistenings were observed in 11 (11%) of 100 SA30AL cases at a mean follow-up of 8 months. No glistenings in 40 cases were seen in the SA60AT group at a mean follow-up of 3 months. CONCLUSIONS: The single-piece acrylic lenses performed well in all regards. Although not as intense as observed with the earlier 3-piece designs, pseudophakic dysphotopsia occurred in a few patients with the single-piece acrylic lens. Intraocular lens exchanges with single-piece IOLs may be accomplished with less difficulty early rather than late.

Acrylic Resins↗

Cell response to AcrySof intraocular lenses in an Indian population.

PURPOSE: To evaluate the quantitative cytological response to AcrySof (Alcon) intraocular lenses (IOLs) in an Indian population by studying the incidence, fate, progression, and severity of cell deposits after uneventful phacoemulsification. SETTING: Iladevi Cataract & IOL Research Center, Ahmedabad, India. METHOD: This clinical prospective study comprised 64 eyes of 64 healthy patients with senile cataract and no other ocular pathology having phacoemulsification and implantation of an AcrySof IOL. The eyes were observed for cell deposits. One week and 1, 3, 6, 12, and 15 months postoperatively, specular reflex was obtained by slitlamp biomicroscopy under x 20 magnification to record the incidence, progression, morbidity, and severity of small and large (including giant) cells on the IOLs. RESULTS: The highest incidence of small cells was 18.7%. The cell deposits appeared at 1 week, peaked at 1 month, and were gone after 6 months. The severity was never more than grade 2 (5 to 10 cells). The highest incidence of large cells, including giant cells, was 23.4%. The deposits appeared at 1 month, peaked at 3 months, and were gone after 12 months. The severity was never more than grade 2 (3 to 5 cells). The highest incidence of giant cells was 6.2%. The deposits appeared at 3 months and were gone by 15 months. Severity was never more than grade 1 (2 cells). No IOL had cell deposits at the last follow-up (mean 14 months +/- 3.25 [SD]). CONCLUSIONS: The incidence, and especially the severity, of cell deposits in the Indian population was low. All cell types, including giant cells, disappeared within 12 months. This could reflect the biocompatibility of the AcrySof IOL and the appropriate surgical technique.

Acrylic Resins↗

Painting technique for staining the anterior lens capsule.

We describe a technique of capsule staining called capsule painting. Using a Khokhar capsule painting cannula, the dye is spread directly over the anterior capsule but to no other part of the anterior chamber. There is minimal turbulence in the anterior chamber as there is no need to replace the injected viscoelastic material. The use of minimal dye and viscoelastic material reduces the cost of surgery.

Capsulorhexis↗

Management of posterior polar cataract.

In this technique for managing posterior polar cataract, extreme care is taken not to overpressurize the anterior chamber or capsular bag to prevent posterior capsule rupture. Minimal hydrodissection and hydrodelineation are performed. The nucleus is extracted using minimal ultrasound energy. Viscodissection is used as a primary technique to mobilize the epinucleus and cortex. A protective layer is preserved over the posterior polar region until the conclusion of the extraction procedure to minimize the risk of loss of lens material into the vitreous cavity in the case of a capsule defect.

Capsulorhexis↗

Intraocular lens movement caused by ciliary muscle contraction.

PURPOSE: To investigate intraocular lens (IOL) movement, measured as a change in anterior chamber depth (ACD) caused by pilocarpine-induced ciliary muscle contraction. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: In this prospective study, the ACD was measured using high-precision, high-resolution, dual-beam partial coherence interferometry in 62 pseudophakic eyes of 55 patients under pilocarpine- and cyclopentolate-induced ciliary muscle contraction and relaxation. The following were studied: 2 models of a ring-haptic IOL (designed to accommodate), a plate-haptic IOL, and 3 types of 3-piece IOLs. Measurements were performed 3 months after surgery. RESULTS: The ring-haptic IOLs and plate-haptic IOL showed a forward movement (ring haptic 43A, -116 microm; ring haptic 43E, -222 microm; plate haptic -162 microm). The 3-piece IOLs showed no change in ACD except in 1 IOL type in which there was backward movement (156 microm). CONCLUSIONS: Pilocarpine-induced ciliary muscle contraction caused forward movement of ring- and plate-haptic IOLs that resulted in an estimated accommodative amplitude of less than 0.50 diopter in most cases. The accommodating ring-haptic IOLs did not perform better than the conventional plate-haptic IOL.

Accommodation, Ocular↗

Posterior capsule dehiscence during phacoemulsification and manual extracapsular cataract extraction: comparison of outcomes.

PURPOSE: To compare the intraoperative behavior and postoperative outcomes of posterior capsule dehiscence during phacoemulsification and during manual extracapsular cataract extraction (ECCE). SETTING: L.V. Prasad Eye Institute, Hyderabad, India. METHODS: This study was a retrospective chart review of consecutive cases of posterior capsule dehiscence over 2 years in patients having phacoemulsification or manual ECCE. A chi-square test was used for statistical comparison of the results in the 2 groups. RESULTS: In the 127 eyes with posterior capsule dehiscence, the incidence of vitreous prolapse was comparable between the 2 groups (phacoemulsification, 61.6%; ECCE, 62.7%). In the phacoemulsification group, vitreous prolapse occurred more frequently if nuclear fragments were present at the time of posterior capsule dehiscence than if they were present during cortex removal (P =.05). Posterior dislocation of nuclear fragments occurred in 4 eyes in the phacoemulsification group. Increased anterior uveitis in the early postoperative period occurred more frequently in the ECCE group (P =.02). The visual outcomes were similar between the 2 groups. CONCLUSIONS: Even though differences existed between the intraoperative factors influencing the management of posterior capsule dehiscence during phacoemulsification and ECCE, the final anatomic and visual outcomes were comparable.

Capsulorhexis↗

Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens.

PURPOSE: To analyze techniques of measuring accommodation after implantation of an accommodating posterior chamber intraocular lens (PC IOL). SETTING: Department of Ophthalmology and University Eye Hospital, University Erlangen-Nürnberg, Erlangen, Germany. METHODS: This prospective study analyzed 23 eyes of 23 patients (aged 41 to 87 years) after cataract surgery and PC IOL implantation (1 CU, HumanOptics) 4 weeks and 3 and 6 months after surgery. The results were compared to those in an age-matched control group (n = 20) 6 months after surgery. The following methods were used to measure accommodation: dynamic with objective techniques (PlusOptix PowerRefractor videorefractometry, streak retinoscopy) and subjective techniques (subjective near point [push-up test, accommodometer], defocusing); static with pharmacologic stimulation after pilocarpine 2% eyedrops directly (conventional refractometry); indirectly (change in the anterior chamber depth [ACD] with Zeiss IOLMaster). RESULTS: Results at 6 months, given as mean +/- SD (range), in the study and control groups, respectively, were as follows: near visual acuity (Birkhäuser reading charts at 35 cm) with distance correction, 0.32 +/- 0.11 (0.20 to 0.60) and 0.14 +/- 0.10 (0.05 to 0.30); accommodation amplitude (diopters) by PowerRefractor, 1.00 +/- 0.44 (0.75 to 2.13) and 0.35 +/- 0.26 (0.10 to 0.65), by retinoscopy, 0.99 +/- 0.48 (0.13 to 2.00) and 0.24 +/- 0.21 (-0.13 to +0.75), by subjective near point, 1.60 +/- 0.55 (0.50 to 2.56) and 0.42 +/- 0.25 (0.00 to 0.75), and by defocusing, 1.46 +/- 0.53 (1.00 to -2.50) and 0.55 +/- 0.33 (0.25 to 0.87). The mean ACD decrease (mm) was 0.78 +/- 0.12 (0.49 to 1.91) and 0.16 +/- 0.09 (0.00 to 0.34) after pilocarpine 2% eyedrops, indicating a mean accommodation of 1.40 D and 0.29 D, respectively, based on Gullstrand's model eye (P =.001). The lowest fluctuation between follow-ups was with the subjective near point and the defocusing techniques followed by ACD decrease with the IOLMaster. CONCLUSIONS: Accommodation after implantation of an accommodating PC IOL should be assessed with several techniques, including subjective and objective, to differentiate true pseudophakic accommodation from pseudoaccommodation. Researchers should be aware of the different variability and consistency of measurements with each technique over time.

Accommodation, Ocular↗

Clear lens extraction with intraocular lens implantation for hyperopia.

PURPOSE: To analyze the results of clear lens extraction (CLE) with posterior chamber intraocular lens (IOL) implantation to correct hyperopia. SETTING: Eye Research Center and Dr. Agarwal's Eye Hospital, Chennai, India. METHODS: This prospective study comprised 20 hyperopic eyes of 12 patients between 19 and 50 years who had CLE with posterior chamber IOL implantation. Five patients had peripheral iridectomy during CLE as the angles were occludable. RESULTS: The mean hyperopic spherical equivalent refraction was +6.66 diopters (D) +/- 2.17 (SD) (range +4.75 to +13.00 D). The IOL power was calculated using the Holladay 2 formula. The mean follow-up was 16.96 months (range 6 to 35 months). The mean postoperative uncorrected visual acuity was 0.45 +/- 0.25 (range 0.10 to 1.00), a mean improvement of 3 Snellen lines from preoperatively. The mean postoperative best corrected visual acuity (BCVA) was 0.63 +/- 0.30, a mean improvement of 1 Snellen line. Three patients gained 2 lines of BCVA and 2 patients, 1 line. One patient lost 1 line of BCVA. Seventy percent of patients were within +/-0.50 D of the intended refraction. CONCLUSION: The results indicate that CLE with posterior chamber IOL implantation is safe, predictable, and effective.

Adult↗

Impact of a modified optic design on visual function: clinical comparative study.

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with a modified anterior surface designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients results in improved pseudophakic quality of vision. SETTING: Department of Ophthalmology, Bundesknappschaft's Hospital, Sulzbach, Germany. METHODS: In an intraindividual randomized study of 45 patients with bilateral cataract, an IOL with a modified anterior surface (Tecnis Z9000, Pharmacia) was compared with a biconvex lens with spherical surfaces (SI-40, Allergan). All patients had bilateral cataract surgery; in 1 eye the Z9000 IOL was implanted and in the other, the SI-40 IOL. After 1 and 3 months, the following investigations were performed: assessment of the anterior and posterior segments including IOL decentration and tilt, pupil size, high- and low-contrast visual acuities, photopic and mesopic contrast sensitivities, and wavefront aberration of the cornea and eye. RESULTS: Thirty-seven patients were examined at all follow-up visits. Although the eyes with the Z9000 IOL had significantly better best corrected visual acuity after 3 months, the improved quality of vision was more apparent when assessing low-contrast visual acuity and contrast sensitivity. Wavefront measurements revealed no significant spherical aberration in eyes with a Z9000 IOL but significantly positive spherical aberration in eyes with an SI-40 IOL. CONCLUSIONS: The clinical results confirm the theoretical preclinical calculations that the spherical aberration of the eye after cataract surgery can be eliminated by modifying the anterior surface of the IOL. The Tecnis Z9000 lens compensates for the positive spherical aberration in older eyes. This leads to a significant improvement, particularly in contrast sensitivity and mesopic visual quality.

Aged↗