PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particulate Matter”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Mutagenicity of organic extracts from Santiago (Chile) airborne particulate matter.

The Ames test has been used to detect the mutagenic activity of organic extracts from Santiago (Chile) airborne particles collected in 1990 and 1991 in one of the monitoring net system stations (MACAM). The samples were assayed with the strains TA98, TA98-NR, and TA98/1,8-DNP6 of Salmonella typhimurium, in the presence and in the absence of liver S9 fraction obtained from rats treated with Aroclor 1254. With the strain TA98 all the samples showed a very high mutagenic response either in the presence or in the absence of S9 fraction, suggesting that Santiago airborne particles contain both indirect-acting (polycyclic aromatic hydrocarbons) and direct-acting mutagenic agents. The mutagenicity of Santiago airborne particles was much higher than that reported in studies performed in other countries. Results obtained with the strains TA98-NR and TA98/1,8-DNP6 suggest that the extracts also contain mononitro and dinitroarenes. These nitroarenes have been described as very potent mutagenic agents, that can be generated by photochemical reactions under certain atmospheric conditions, or in the combustion of fuel, especially of diesel motors. The presence of polycyclic aromatic hydrocarbons and nitroarenes in Santiago airborne particles, as well as the high levels of mutagenicity detected, suggest that the inhabitants permanent exposure to these kinds of compounds represents a high risk for human health.

Air Pollutants↗

Contribution of wood stoves and fire places to mutagenic activity of airborne particulate matter inside homes.

Wood combustion produces compounds that are mutagenic in the Salmonella/microsome assay. As combustion products can be emitted in the home and the use of wood as a residential energy source is growing, an impact on human health might be of concern. In this study experiments were carried out to determine the contribution of wood combustion in stoves and fire places to indoor mutagenic activity under normal living conditions. Airborne particles from living rooms which were heated by stoves, or by fire places, and from outdoors were collected simultaneously. In each room two samples were collected during two consecutive weeks: one week the room was heated by central heating, the other week by wood combustion. Sampling took place in a total of 24 homes. Methanol extracts of the samples were tested in the Salmonella/mammalian microsome assay. Results show that mutagenic activity of outdoor air exceeds indoor mutagenicity. At the same time a correlation is found between in- and out-door mutagenicity, both with and without S9. However, a large difference is found between the ratio -S9/+S9 of in- and out-door mutagenic activity. Systematic differences in the ratio -S9/+S9 between control and experimental conditions are not observed. The use of wood stoves caused an increase of indoor mutagenicity in 8 out of 12 homes. It could be concluded that the use of an open fire consistently leads to an increase of mutagenic activity. This increase was caused by wood combustion products.

Air Pollutants↗

Comparative analysis of the clastogenicity and cytotoxicity of airborne particulate matter generated during the fire at Schweizerhalle on November 1, 1986.

Methanol extracts from 4 pairs of airconditioner filters (one fire-exposed and one control) from various locations (A, B, C and D) at various distances from the site of the fire were examined for their capacity to induce structural chromosomal aberrations and/or cytotoxicity in Chinese hamster V79 cells. Extracts from 2 additional sets of 3 filters which were exposed to urban air for 3 consecutive periods of 10 or 11 days some 4 months after the fire were also tested. Chromosomal aberrations were induced by all filter extracts from location B, as well as by an unused (non-exposed) filter, in a dose-dependent manner. Without the addition of metabolizing enzymes, aberrations were induced only at concentrations which caused more than 95% cell killing. This was not taken as an indication for clastogenic activity of the filter extracts, but was assumed to represent the chromosomal expression of metabolic changes in dying cells. Upon the addition of S9, chromosomal aberrations were induced at biologically relevant survival rates. Under metabolizing conditions, the ranking of the potential of the filter extracts from location B to induce chromosomal aberrations and to cause cell killing was identical. The remaining extracts (locations A, C and D) were therefore tested for cytotoxicity only. The toxicity data indicated that, of 3 pairs of filters, the fire-exposed one was not different from the control. Of the fourth pair (location B), the fire-exposed filter was 2.0-2.5 times more cytotoxic and clastogenic than the control. However, extracts of urban air-exposed filters from this location (exposed in March and April 1987) showed a large variation in toxicity and clastogenicity as well. One was clearly more active than the control (but less than the fire-exposed filter), while the other 2 were either somewhat more or less clastogenic than the control filter. In addition, 4 out of 5 filters from this location were more polluted (as indicated by cytotoxicity) than all the filters from the other locations, irrespective of whether they were fire-exposed or not. It is concluded that the results of this V79 cytotoxicity/clastogenicity test did not confirm the hypothesis that the fire at Schweizerhalle produced clastogenic material at quantities detectable under the conditions employed.

Air Pollutants↗

Cytogenetic effects of airborne particulate matter in human lymphocytes in vitro.

City smog was collected in a heavily industrialized area and investigated for its ability to induce cytogenetic effects in human lymphocytes in vitro. Total extract of city smog was found to produce sister-chromatid exchanges and chromosomal aberrations in a dose-dependent manner. In addition cell-cycle delay was observed at higher concentrations of city smog extract. Results of cytogenetic testing are discussed with respect to cell-cycle kinetics.

Chromosome Aberrations↗

Feasibility of dose adjustment based on differences in long-term clearance rates of inhaled particulate matter in humans and laboratory animals.

Long-term pulmonary clearance rates were evaluated for several laboratory animal species, dogs, and humans to determine if differences among species exist, and if so, the adequacy of the data for dose adjustment. Within each species, large variations in clearance rates were seen, probably as a result of differences in solubility of the aerosol particles, differences in measurement techniques, possible lung damage, transport to lung-associated lymph nodes, and binding of dissolved chemicals to cellular macromolecules in the lung. While few direct comparisons among species using the same aerosol were available, mechanical clearance of particles from the alveolar regions of dogs and humans was generally slower than in most laboratory species, with t1/2 values several-fold longer. Particle clearance rate variations of this magnitude were shown to induce potentially large differences in bioavailability. This can result in large errors in assessing human risk from animal studies unless a dose adjustment is made. It is suggested that despite limitations on available data, a two- to threefold adjustment of dose when extrapolating from small laboratory animals to humans, for quantitative risk assessment, should be considered, unless solubility half-times are very short.

Air Pollutants↗

Application of capillary electrophoresis combined with a modified BCR sequential extraction for estimating of distribution of selected trace metals in PM2.5 fractions of urban airborne particulate matter.

The capillary electrophoresis (CE) method combined with a sequential extraction was applied to determine the distribution of Fe, Zn, Cu, Mn and Cd in urban ambient air PM2.5 samples. PM2.5 was collected on Teflon filters with dichotomous sampler, and the modified extraction procedure following the BCR leaching procedure was used to chemically fractionate metals into "easily exchangeable" with water, "acid extractable" with 0.11 mol/l acetic acid, "reducible" with 0.1 mol/l hydroxylamine hydrochloride acidified to pH 2.0 with nitric acid, and "oxidisable" with oxidation by 8.8 mol/l hydrogen peroxide (H2O2) followed by extraction with 1.0 mol/l ammonium acetate. Based on the obtained results it was concluded that the application of the studied methodology provides chemical fractionation data that reflect the general sources and potential health hazards of the studied metals.

Air Pollutants↗

Levels of total suspended particulate matter and major trace elements in Kosovo: a source identification and apportionment study.

Concentration levels of total suspended particles (TSP) and 27 major, minor and trace elemental components were determined at four sites in Kosovo through a 1-year survey (January-December 2002). Ambient concentrations were evaluated in comparison to limit values. The origin of elemental TSP constituents was investigated by calculating enrichment factors and diagnostic ratios. Multivariate statistics, such as hierarchical cluster analysis and factor analysis, were also employed to identify emission sources. A multivariate statistical receptor model (Absolute Principal Component Analysis, APCA) was applied to quantify source contributions. Soil dust, cement production, vehicular emissions, brake wear, and fuel combustion were identified as major sources with variable contributions at the four sampling sites.

Air Pollutants↗

Source contributions to fine particulate matter in an urban atmosphere.

This paper proposes a practical method for estimating source attribution by using a three-step methodology. The main objective of this study is to explore the use of the three-step methodology for quantifying the source impacts of 24-h PM2.5 particles at an urban site in Seoul, Korea. 12-h PM2.5 samples were collected and analyzed for their elemental composition by ICP-AES/ICP-MS/AAS to generate the source composition profiles. In order to assess the daily average PM2.5 source impacts, 24-h PM2.5 and polycyclic aromatic hydrocarbons (PAH) ambient samples were simultaneously collected at the same site. The PM2.5 particle samples were then analyzed for trace elements. Ionic and carbonaceous species concentrations were measured by ICP-AES/ICP-MS/AAS, IC, and a selective thermal MnO2 oxidation method. The 12-h PM2.5 chemical data was used to estimate possible source signatures using the principal component analysis (PCA) and the absolute principal component scores method followed by the multiple linear regression analysis. The 24-h PM2.5 source categories were extracted with a combination of PM2.5 and some PAH chemical data using the PCA, and their quantitative source contributions were estimated by chemical mass balance (CMB) receptor model using the estimated source profiles and those in the literature. The results of PM2.5 source apportionment using the 12-h derived source composition profiles show that the CMB performance indices; chi2, R2, and percent of mass accounted for are 2.3%, 0.97%, and 100.7%, which are within the target range specified. According to the average PM2.5 source contribution estimate results, motor vehicle exhaust was the major contributor at the sampling site, contributing 26% on average of measured PM2.5 mass (41.8 microg m-3), followed by secondary sulfate (23%) and nitrate (16%), refuse incineration (15%), soil dust (13%), field burning (4%), oil combustion (2.7%), and marine aerosol (1.3%). It can be concluded that quantitative source attribution to PM2.5 in an urban area where source profiles have not been developed can be estimated using the proposed three-step methodology approach.

Air Pollutants↗

Trace elements in atmospheric particulate matter over a coal burning power production area of western Macedonia, Greece.

Total suspended particle (TSP) concentrations were determined in the Eordea basin (western Macedonia, Greece), an area with intensive lignite burning for power generation. The study was conducted over a one-year period (November 2000-November 2001) at 10 sites located at variable distances from the power plants. Ambient TSP samples were analyzed for 27 major, minor and trace elements. Annual means of TSP concentrations ranged between 47+/-33 microg m(-3) and 110+/-50 microg m(-3) at 9 out of the 10 sites. Only the site closest to the power stations and the lignite conveyor belts exhibited annual TSP levels (210+/-97 microg m(-3)) exceeding the European standard (150 microg m(-3), 80/779/EEC). Concentrations of TSP and almost all elemental components exhibited significant spatial variations; however, the elemental profiles of TSP were quite similar among all sites suggesting that they are affected by similar source types. At all sites, statistical analysis indicated insignificant (P<0.05) seasonal variation for TSP concentrations. Some elements (Cl, As, Pb, Br, Se, S, Cd) exhibited significantly higher concentrations at certain sites during the cold period suggesting more intense emissions from traffic, domestic heating and other combustion sources. On the contrary, concentrations significantly higher in the warm period were found at other sites mainly for crustal elements (Ti, Mn, K, P, Cr, etc.) suggesting stronger influence from soil resuspension and/or fly ash in the warm months. The most enriched elements against local soil or road dust were S, Cl, Cu, As, Se, Br, Cd and Pb, whereas negligible enrichment was found for Ti, Mn, Mg, Al, Si, P, Cr. At most sites, highest concentrations of TSP and elemental components were associated with low- to moderate-speed winds favoring accumulation of emissions from local sources. Influences from the power generation were likely at those sites located closest to the power plants and mining activities.

Air Pollutants↗

Particulate matter and black smoke concentration levels in central Athens, Greece.

This study presents the statistical analysis of PM(10) and PM(2.5) concentrations (measured at a central site, in the Athens area), along with black smoke (BS) data, for a 2-year period. The biennial average concentrations of PM(10) and PM(2.5) were 75 and 40 microg m(-3). The respective average concentration of BS, as estimated by the OECD method, was 108 microg m(-3). Severe exceedances of the PM(10) air quality standards were recorded. The seasonal variation of PM(10) and BS was less pronounced than the variation of PM(2.5), which concentration was elevated by 14.2% during the cold period. Concentrations of all three pollutants were significantly lower during weekends; however, PM(2.5) and BS displayed a more uniform weekly distribution pattern. PM(10) particles were found to be almost equally comprised by PM(2.5) and PM(10-2.5) particles (PM(2.5)/PM(10) ratio=0.53+/-0.09 microg/m(3)). The average PM(10)/BS value was found lower than unity revealing the inappropriateness of the used reflectance conversion method, for the estimation of mass-equivalent BS concentrations, in the study area, where diesel-powered vehicles mainly control emissions of light-absorbing substances. Important reductions in concentrations were observed during days when drivers of diesel-powered taxies and transportation buses went on strike (reaching 40% for BS). Calm wind conditions were found to have an incremental effect on particle concentrations and were also associated with the appearance of persistent episodic events. Increased PM levels were also observed during southern-southwestern wind flows while significantly lower-than-average concentrations were measured during precipitation events. Separate regression analyses were performed for PM(10), PM(2.5) with BS and NO(x) as independent variables, in an attempt to estimate the relative contribution of specific source types (diesel-powered vehicles) to measured particle levels. The contribution of the diesel-exhaust component to PM(10) mass was estimated at 49.9%, while the corresponding contributions to PM(2.5) mass concentrations was 53.8%. These results may have important implications with the oncoming decision of national authorities to allow the purchase of diesel-powered private cars to the residents of the Greater Athens Area, which was forbidden up to this day.

Air Pollutants↗

Characterisation of aerosol particulate matter from urban and industrial environments: examples from Cardiff and Port Talbot, South Wales, UK.

A high-volume cascade impact collector (1100 l/min air flow) was used to collect air samples in an industrial (Port Talbot) and an urban (Cardiff) site with the purpose of characterising both coarse (PM(10-2.5)) and fine (PM(2.5)) fractions comprising the total sample. PM(10-2.5) and PM(2.5) samples were collected by cascading air through two polyurethane foams on which particles impact and become deposited. Air sample collection rates are to some extent dependent on weather conditions, notably rainfall, humidity, and especially, wind direction, but samples show a very different and distinctive air particle composition between the two collection sites. Thus, although both Cardiff and Port Talbot are coastal sites and therefore have high contents in chlorides, Port Talbot is extremely rich in tiny Fe spherules (>30%, in both coarse and fine fractions) from a nearby steel plant. Mineralogical characterisation using SEM-EDX shows a clear fractionation between the particle composition in the PM fractions, with the coarse fraction being dominated by chlorides, sulphates (gypsum), and silicates, and the fine fraction having high proportions of ammonium sulphates and elemental and organic carbon compounds, most of the latter being linked to traffic pollution.

Journal Article↗