In vivo biocompatibility of catheter materials.

The inflammatory response to four different catheter materials was quantitatively characterized using an in vivo cage implant system over a 21 d implantation period. The greatest differences between materials were observed at day 4, where the total leucocyte concentration in the exudate decreased in the following order: AE-PVC greater than A-PU greater than D-PU1 greater than D-PU2. Similar trends were observed for the polymorphonuclear leucocyte (PMN) and macrophage concentrations at day 4. At day 7, this trend continued, but by day 21 the total leucocyte concentration, PMN concentration and macrophage concentration had decreased to comparable values for all materials. The extracellular alkaline phosphatase activity at day 4 was lowest for the AE-PVC exudate samples. Similar results were observed for the extracellular acid phosphatase activity but after that time point no significant differences were observed. From these results, it appears that AE-PVC is least biocompatible compared with the other three catheter materials, which were polyurethanes.

Acid Phosphatase↗

Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium.

Hydroxyl radicals formed from hydrogen peroxide during an inflammatory response are potent agents for cellular deterioration. The behaviour of implanted material in terms of its ability to sustain or stop free radical formation may be therefore very important. In vitro studies of titanium which is known to be biocompatible and osseointegrates into human bone were carried out. In our model studies, the production of free radicals from H2O2 at Ti and TiO2 surfaces was measured by spin trapping techniques. Our findings suggest that there is no sustained hydroxyl radical production at a titanium (oxide) surface. We propose that this is due to the quenching of the Fenton reaction through both trapping and oxidation of superoxide radicals in a TiOOH adduct.

Biocompatible Materials↗

Intraocular PMMA lenses modified with surface-immobilized heparin: evaluation of biocompatibility in vitro and in vivo.

Intraocular lenses (IOL) were surface modified with covalently linked heparin. The surface-bound heparin could not be removed by incubation in solutions known to be effective in breaking non-covalent bonds, nor by incubation in a solution of proteinase K and only to a limited extent by incubation with heparinase. In vitro studies demonstrated improved biocompatibility by the heparin surface-modified lens with respect to outgrowth of fibroblasts and macrophages, activation of granulocytes and adhesion of platelets. These results were subsequently verified in vivo in terms of less inflammatory cells on the lens surface and fewer incidences of synechiae after 3 and 6 wk IOL implantation in the rabbit eye.

Animals↗

In vivo biocompatibility of collagen-poly(hydroxyethyl methacrylate) hydrogels.

Collagen-p(HEMA) hydrogels were subcutaneously implanted in rats for up to 6 month and the immediate short- and long-term tissue response to these implants was studied. Histopathological data indicated that the tissue reaction at the implant site progressed from an initial acute inflammatory response characterized by the presence of eosinophils and polymorphs to a chronic response marked by few macrophages, foreign body giant cells and fibroblasts. After one month a very thin fibrous capsule (approximately 11 microns thick) was observed around the implant. Even 6 month post-implantation, the capsule thickness was maintained at about 11-12 microns. No necrosis, calcification, tumorigenesis or infection was observed at the implant site up to 6 month. Fibrous capsule analysis showed that the collagen content and the capsule thickness were well within the threshold limits. The collagen-p(HEMA) hydrogels were found to be well-tolerated, non-toxic and highly biocompatible.

Animals↗

Biocompatibility of elastin-fibrin material in the rat.

Biocompatibility and biodegradability of a new elastin-fibrin material were investigated in several organs and tissues of the rat. It has been demonstrated that the material was quite well tolerated in all cases, except in bone marrow. Its use is considered in several aspects of reparative or constructive surgery.

Animals↗

Formation of continuous collagen fibres: evaluation of biocompatibility and mechanical properties.

Reconstituted collagen fibres have potential applications in repair of soft and hard tissues. Preliminary studies conducted in our laboratory suggest that discontinuous reconstituted type I fibres have strengths similar to those of fibres teased from tendons. The purpose of this paper is to report a method for continuous collagen fibre production and the properties of fibres produced. Ultimate tensile mechanical properties and biocompatibility of continuous type I collagen fibres were studied and compared with the properties of fibres produced manually (discontinuous fibres). In general, continuously made cyanamide cross-linked fibres show slightly inferior mechanical properties and faster biodegradation rates compared with manually made fibres because of minor differences in the fibreformation protocol introduced by design constraints. However, continuous and discontinuous fibres crosslinked with glutaraldehyde had comparable properties. These results demonstrate that production of 50 microns diameter continuous collagen fibre is possible.

Animals↗

In vitro studies on biocompatibility of hyaluronic acid esters.

The biocompatibility of semisynthetic polymers formed from hyaluronic acid esters has been studied using fibroblast cultures. The polymers, added to the culture medium, used either in powdered form or as thin membranes, behave as inert materials. The cells used in the experiments grow normally in the culture dishes. With regard to adhesiveness the cells were not able to spread on the biomembranes and tended to form isolated clusters of round cells. Human fibronectin, placental collagen (type I-IV) and fibrin could be stratified on biomembranes. When these molecules reacted with the biomaterial the film became suitable for fibroblasts spreading and growth.

Animals↗

Biocompatible polyphosphazenes by radiation-induced graft copolymerization and heparinization.

Investigations were carried out on the radiation-induced graft copolymerization by direct irradiation of dimethylaminoethyl methacrylate on to poly(bis(trifluoroethoxy)phosphazene) and on to poly (bis(phenoxy)phosphazene). Kinetics of grafting were followed with the polyphosphazenes immersed in monomer - methanol mixtures of various composition. The grafted film samples were quaternized with methyl iodide and, to the produced ammonium group, heparin was ionically bonded with high yield. On the grafted and heparinized-grafted film samples an evaluation of hydrophilicity, mechanical properties, biocompatibility and anticoagulating properties was carried out.

Animals↗

Biocompatibility of diamond-like carbon coating.

Diamond-like carbon coating is an inert, impervious hydrocarbon coating with properties suitable for use in the biomedical field, particularly in orthopaedic implants. Mouse peritoneal macrophages and mouse fibroblasts were grown on tissue culture plates treated with diamond-like carbon and the biocompatibility assessed both biochemically and morphologically. This investigation showed that diamond-like carbon coating caused no adverse effects on cells in culture and therefore merits further investigation as a coating for biomedical use.

Animals↗

3-Methoxybutylcyanoacrylate: evaluation of biocompatibility and bioresorption.

The biocompatibility and bioresorption of 3-methoxybutylcyanoacrylate (MBCA) was evaluated in vivo using female Wistar albino rats. MBCA was found to elicit slight to moderate tissue reaction similar to isobutylcyanoacrylate (iBCA) which has been sold commercially as a surgical adhesive (Bucrylate, Ethicon). MBCA was judged less reactive to tissue than ethylcyanoacrylate (ECA). The MBCA implants in rat gluteal muscles also resorbed within approx. 16 wk while iBCA implants remained essentially unchanged at 36 wk in vivo. In vitro resorption in phosphate buffer (pH 7.2) at 37 degrees C showed the same trend. The MBCA performed similarly to iBCA as a haemostat on excised rat livers and as an adhesive on rat skin incisions and had comparable adhesive bond strength.

Absorption↗

Biocompatibility of lipid microcylinders: effect on cell growth and antigen presentation in culture.

The authors are developing a lipid-based microcylinder for the controlled release of biological response modifiers and as templates for cellular migration and differentiation. These structures are comprised of a photopolymerizable phosphatidylcholine (1,2-ditricosa-10,12-diynoyl-sn-glycero-3-phosphocholine) and form spontaneously as a result of a thermotropic phase transition in aqueous solution or in a cosolvent solution of 70:30 ethanol:water. The hollow cylinders are helically wrapped lipid bilayers, variable in length (50-250 microns, depending on conditions of formation) and are 0.5-1.0 microns in diameter. The interaction has been examined of three types of lipid microcylinders: (1) monomeric, (2) photopolymerized by exposure to 254 nm light, and (3) surface-modified by incorporation of 6 mol% gangliosides, with different human cell lines and peripheral blood leucocytes to evaluate the biocompatibility of these structures. The proliferative status of U937 (a histiocytic monocyte), K562 (an erythroleukaemic cell), and Jurkat's derivative (a T-lymphoblast) as measured by pulsed tritiated thymidine was unaffected by the presence of up to 100 micrograms/ml of lipid microcylinders after 3 d in culture. Adherent human peripheral blood monocytes were shown to form adhesive contacts with the lipid microcylinders. An 'association' index from this interaction shows that after 3 d in culture, the association was much lower for those microcylinders that had incorporated ganglioside compared with monomeric or polymerized structures. The lipid microcylinders do not activate T-cells isolated from human peripheral blood, nor do they inhibit the activation of T-cells by phorbol esters or other mitogens.(ABSTRACT TRUNCATED AT 250 WORDS)

Antigens↗

Biocompatibility of particulate polymethylmethacrylate bone cements: a comparative study in vitro and in vivo.

The biocompatibility of particles of four different commercial polymethylmethacrylate (PMMA) bone cements was evaluated by exposing human synovial fibroblasts and mouse peritoneal macrophages to particles of cement. Cell integrity and inflammatory potential were assessed using enzyme release and microscopical examination. Results suggested the occurrence of cell damage in both cell types and macrophage studies indicated inflammatory potential. The response in vivo was investigated by intra-articular injection of the particles into mouse knee joints. Clinical and histological evaluation was performed over 2-52 wk. Particles of all four cements were well tolerated in the joints.

Acetylglucosaminidase↗

Biocompatibility and resorbability of a polylactic acid membrane for periodontal guided tissue regeneration.

The biocompatibility and degradation processes of biomembranes made of a mixture of a high molecular weight racemic polylactic acid (PLA50P) with 0, 10, 20 and 30% w/w racemic polylactic acid oligomers (PLA50p) were assessed for morphological changes in subcutaneous abdominal membrane implantations after 15, 21, 30 and 60 d in 45 Wistar rats. These membranes, prepared for periodontal guided tissue regeneration, showed excellent tissue tolerance without an inflammatory reaction. The higher the content in low molecular weight polylactic acid, the higher the degradation rate. At 60 d, the resorption process was almost complete. This process was initiated by outgrowths of short vascular septa, which developed into lobular networks infiltrating the membranes, which were progressively replaced by normal fibrous connective tissue.

Animals↗

Biocompatibility of polyoxymethylene (Delrin) in bone.

The bone tissue reaction to bulk polyoxymethylene (Delrin) was studied in eight adult albino rabbits followed for up to 5 months after insertion of implants into the tibial metaphyses. Each animal received two implants, one of pure Delrin, the other a 'mosaic' plug with alternating areas of commercially pure titanium and Delrin. At the passage through the cortex, a direct bone-Delrin contact was seen in more than half of the cases, but the contact was usually limited in extent. At the same time, in virtually all sections, a foreign-body reaction with macrophages and giant cells was prominent. It was concluded that bulk Delrin has inferior biocompatibility to titanium, and the advisability of using Delrin as a biomaterial for bone anchorage is questionable.

Animals↗

Biocompatibility of glass ionomer cements.

Glass ionomer cements (GICs) are widely used in the dental field and are increasingly being considered as materials with potentially good osteogenic properties. This paper details a comprehensive biocompatibility evaluation of a number of GICs. These include conventional, commercially available materials, novel formulations and a new light cured material. The experimental programme entailed in vitro cell culture studies using direct contact and extraction tests and an in vitro rat model in which the GICs were in intimate contact with bone for periods up to 8 wk. The results demonstrate clear differences between the materials and in particular highlight the poor cellular response to the light cured material. Methylthiazolyldiphenyl tetrazolium assay demonstrates stimulation of cell growth by some GIC formulations and indicates that cytotoxic leachable agents can be removed from others. The results obtained following implantation into bone are comprehensively presented using photomicrographs. New bone formation with time is demonstrated with a number of formulations.

Animals↗

Biocompatibility and biodegradation of different hyaluronan derivatives (Hyaff) implanted in rats.

Hyaluronan (HL), a naturally occurring glycosaminoglycan, has been chemically modified through the esterification of its carboxylic groups with different types of alcohol. The physico-chemical properties of these new biopolymers allow the preparation of many biomaterials which may be used in several medical applications. In the present study both the biocompatibility and biodegradation of some water-insoluble HL esters have been evaluated, either as raw material or as manufactured devices after subcutaneous and intraperitoneal implantation in male rats. The inflammatory response and the degree of resorption for each tested material are reported. The relationships between the degree of esterification and the type of alcohol used with the above parameters are also investigated.

Animals↗

Polyimides as biomaterials: preliminary biocompatibility testing.

A number of commercially available polyimide materials were evaluated in vitro using a selected battery of levels I and II testing protocols prescribed by the National Institutes of Health Guidelines for Blood-Material Interactions. These procedures consisted of electron spectroscopy for chemical analysis and contact angle characterization surface studies, and protein adsorption, cell culture cytotoxicity, clotting time and haemolysis biocompatibility testing. The polyimide surfaces were invariant from the bulk composition with 60-80% C, 10-20% O and 2-5% N, producing advancing contact angles in the hydrophobic range (80-100 degrees). Consequently, they adsorbed significant amounts of albumin (2-3 micrograms/cm2) and fibrinogen (0.5-0.8 microgram/cm2). The polyimides also displayed an insignificant level of cytotoxicity and haemolysis, and clotting times ranged from 63 to 98% of normal. These clotting times and haemolytic index values were intermediate between the values observed for Teflon and Silastic controls. These factors, along with the strong adherence of polyimides to metal oxide substrates, indicate that polyimide materials are good candidates for further testing as encapsulants for implantable biosensors.

3T3 Cells↗

Interfacial photopolymerization of poly(ethylene glycol)-based hydrogels upon alginate-poly(l-lysine) microcapsules for enhanced biocompatibility.

The biocompatibility of microcapsules made by the co-acervation of alginate and poly(l-lysine) (PLL) was enhanced by coating the surface of these microcapsules with a poly(ethylene glycol) (PEG)-based hydrogel. The hydrogel was formed by an interfacial photopolymerization technique using visible light from an argon ion laser. The light absorbing chromophore, eosin Y, was immobilized on the microcapsule surface. This restricted the formation of the PEG hydrogel to the surface of the microcapsule. The presence of the PEG gel on the surface was confirmed by fluorescent dextran entrapment, by direct visualization after dissolution of the underlying membrane and by electron spectroscopy for chemical analysis. The biological response of such microcapsules was evaluated by intraperitoneal implantation in mice. The PEG-coated microcapsules were found to be less inflammatory and were seen not to elicit a fibrotic response, as was the case with alginate-PLL microcapsules.

Alginates↗