PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Device Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Surgical indications and outcomes of tympanostomy tube removal.

OBJECTIVE: To evaluate factors affecting perforation healing in children with surgical removal of retained tympanostomy tubes. METHODS: We conducted a retrospective chart review of 82 pediatric patients (111 ears) who underwent surgical tube removal at a tertiary care pediatric hospital from 1/1/1999 to 12/31/2001. Patients included 47 males and 35 females with an age range of 2-15 years (average age, 6.8 years and median, 6 years). The length of intubation ranged from 12 months to 108 months (average, 44.6 months). The indications for removal included: prolonged intubation (61.3%), otorrhea or recurrent infection (21.6%), obstruction (7.2%), tube in middle ear (6.3%), enlarging perforation (2.7%), and in preparation for future cochlear implant surgery (9.9%). Interventions included removal of tympanostomy tubes and techniques for encouraging perforation closure. Seventy-six percent of the ears had a technique used to encourage healing. These techniques included freshen edges (11.8%), Gelfoam or Gelfilm (14.1%), Gelfoam and/or Gelfilm with freshened edges (50.6%). The main outcome measure was perforation healing. Chi-square statistical analysis were used to determine the statistical significant of observations. RESULTS: Overall closure rate for all patients available for follow up was 87.0%, regardless of technique used to encourage healing. There was no statistically significant difference between the average intubation time in ears that healed (44 months), versus those with persistent perforation after removal (42 months). There was no statistical significant difference in closure rate based on patient age. When tubes were removed for prolonged intubation, 87.0% closed. If the indication was otorrhea or recurrent infections, 93.0% healed. CONCLUSIONS: The overwhelming majority of patients who undergo surgical removal of tubes will show complete tympanic membrane healing independent of technique at time of removal, duration of intubation, patient age, or indication for removal.

Adolescent↗

Corporeal excavation: new technique for penile prosthesis implantation in men with severe corporeal fibrosis.

INTRODUCTION: Penile prosthesis implantation in men who have fibrotic corpora as the result of ischemic priapism or previous removal of an infected penile prosthesis poses a significant challenge to the implanting surgeon. We describe a new technique, corporeal excavation, to meet this challenge. TECHNICAL CONSIDERATIONS: The operative approach is through an inverted T penoscrotal incision that affords exposure of nearly the entire corpus cavernosum on each side. Extended corporotomies are made on the ventral aspect of each corpus cavernosum, and a plane of dissection between the fibrotic corporeal tissue and the inner surface of the tunica albuginea is established, resulting in core removal of nearly all fibrotic intracorporeal tissue. Cylinders are laid into the empty corporeal bed, and the tunica albuginea is closed primarily. Nine patients were identified who had undergone this procedure. The operative notes and medical records were reviewed, and telephone interviews were done for follow-up when patients had not been recently seen in the clinic. CONCLUSIONS: Successful outcomes were achieved in all 9 patients. Corporeal excavation permits penile prosthesis implantation in men with severe intracorporeal fibrosis usually resulting from priapism or previous removal of infected penile prostheses.

Device Removal↗

Removal of urolume endoprosthesis using holmium:YAG laser.

A potential complication of UroLume endoprosthesis is migration, which may necessitate removal of the stent. Stent removal may be associated with complications such as urethral injury, bleeding, and external sphincter trauma. We report a patient in whom a holmium:yttrium-aluminium-garnet (Ho:YAG) laser was used to cut the UroLume endoprosthesis into fragments, which led to easy and uneventful stent removal.

Aged↗

A simple technique for laparoscopic removal of silicone adjustable gastric banding.

Laparoscopic adjustable silicone gastric banding is currently among the most common surgical procedures performed in morbidly obese patients. The safety, reversibility, and technical simplicity of this procedure account for its wide and rapid diffusion. Concern still exists about the long term efficacy of the procedure in achieving weight loss and mechanical complications continue to represent the Achilles' heel of the procedure. Little or no attention has been given in the literature to the technical aspects of band removal. The surgical technique must be as simple and minimally invasive as possible. We report the technique we currently use to remove failed bands.

Device Removal↗

Removal of the broken tip of a hexagonal screwdriver from a nail end cap using a magnetic bar.

The tip of the hexagonal screwdriver can be broken and retained in the recess of the end cap of an intramedullary nail. It can happen when the position of the patient's limb suddenly changes during the tightening procedure. Removal of the broken tip is necessary due to metal incompatibility and for the potential of a future procedure. A simple solution for this problem is presented, the use of a magnetic bar normally used for removal of orbital metallic foreign bodies.

Bone Nails↗

Removal of a broken cannulated tibial nail: a simple intramedullary technique.

We present a case illustrating the extraction of a distal segment of a broken cannulated tibial nail. Using minimal soft tissue dissection, a ball-tipped guidewire is inserted through the medial malleolus. It is then threaded through the distal aspect of the broken nail. The guide wire is advanced further proximally out the standard knee incision. When the ball tip engages the end of the broken nail, it can be removed easily.

Adult↗

Weaning of rotary blood pump recipients after myocardial recovery: a computer study of changes in cardiac energetics.

BACKGROUND: Weaning of patients from mechanical cardiac support after myocardial recovery has always involved multiple, interacting factors, particularly the training of the myocardium during reduction of pump flow. Rotary pumps offer training advantages when support flow is reduced, even to nearly zero. We report a computer analysis that evaluates the work required of the heart during partial unloading and removal of rotary pumps. METHODS AND RESULTS: A computer model of the assisted circulation, previously implemented in MATLAB (The MathWorks Inc, Natick, Mass), has been augmented with a model of the MicroMed DeBakey ventricular assist device (MicroMed Technology, Inc, Houston, Tex). Flow, pressure patterns, and external work (pressure-volume area, calculated as the area of the ventricular pressure-volume loop [external work] plus potential energy) were calculated for nonassisted and various continuously assisted patients. Under low-flow conditions, the heart imposes an oscillating forward-backward flow through the non-occlusive rotary pump, causing an increase in ventricular work. Thus, an assist flow of 1 to 1.5 L/min requires work equivalent to that of the unsupported heart. At 60% contractility, the nonassisted pressure-volume area is 1.10 Ws/beat, and the potential energy is 0.38 Ws/beat. At a Qpump of 1 L/min, the pressure-volume area is 1.21 Ws/beat, and the potential energy is 0.37 Ws/beat. At a Qpump of 3 L/min, the pressure-volume area is 0.93 Ws/beat, and the potential energy is 0.29 Ws/beat. These conditions cannot be achieved with pulsatile systems. CONCLUSION: During weaning and retraining, an implanted rotary pump can provide a workload to the heart like that in the nonassisted situation, thus increasing the predictability of weaning and reducing the risk of reiterating heart failure.

Cardiovascular System↗

The fate of the fibrous capsule after saline implant removal.

After removal of a silicone breast implant, if a capsulectomy is not performed, the residual capsule may persist, become calcified, and appear on routine mammograms. The fate of the capsule around saline implants is less clear. The purpose of this study was to determine the fate of the capsule around saline-filled implants in an animal model. Rats were implanted with 6-ml tissue expanders, which were left in place for 4 months. The implants were then removed and the capsules around the injection port (smooth surface) and tissue expander (textured surface) were examined sequentially. The capsules contracted and dissipated gradually over a year in association with a pericapsular vascular proliferation. It may not be necessary to perform a capsulectomy at the time of saline implant removal.

Animals↗

Extraction of entrapped capsules from the small bowel by means of push-and-pull enteroscopy with the double-balloon technique.

The new technique of push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) makes it possible to remove swallowed foreign bodies causing intestinal obstruction deep in the small bowel without the need for surgical laparotomy. This report describes two cases of enteroscopic removal of entrapped capsules. In one patient with acute recurrent intestinal bleeding and recurrent abdominal pain, Crohn's disease had been suspected on capsule endoscopy. The second patient, with known Crohn's disease, was suffering from abdominal pain and underwent capsule endoscopy for investigation of the small bowel. Prior enteroclysis had not revealed stenoses in either patient. An oral approach was chosen and the capsules were identified approximately 140 cm and 310 cm from the pylorus, respectively, in front of stenoses. The capsule endoscopes were removed successfully in both patients by means of push-and-pull enteroscopy using a new enteroscope device.

Device Removal↗

Use of the 3M precise microvascular anastomotic system in grafting 1-mm diameter arteries with polytetrafluoroethylene prostheses: a long-term study.

The 3M Precise Microvascular Anastomotic System has had an experimental long-term testing for the first time in polytetrafluoroethylene (PTFE) 1-mm diameter arterial grafts. The grafts were placed in the infrarenal aorta of 48 rats. At different time intervals (2 weeks, 16 weeks and 1 year), each section containing a graft and its pair of anastomotic devices was removed and processed for light and scanning electron microscopy, with the aid of a newly-designed device. Eighty-three percent of the mechanically anastomosed grafts were found to be patent. Only 14.8 percent of the grafts harvested at 16 weeks or 1 year showed neo-endothelial lining on the inner surface of the graft. A constant finding of this study was the marked atrophy of the aortic media within the devices, that was progressively evident from 2 weeks to 1 year. A network of capillaries within the graft walls was present at 16 weeks. In one case, a large capillary was found to traverse the graft wall and to reach the luminal surface, suggesting that transmural capillaries may contribute to the formation of neo-intima in 1-mm PTFE grafts.

Anastomosis, Surgical↗

Influence of titanium surface roughness on attachment of Streptococcus sanguis: an in vitro study.

The purpose of the present study was to investigate the efficacy of the decontamination protocol for bacterial removal in titanium surfaces with three different levels of roughness using a high-pressure sodium bicarbonate device for 1 minute under aseptic conditions. Group 1 was composed of 10 as-machined titanium sheets and Groups 2 and 3 of titanium sheets blasted with aluminum oxide (Al2O3, alumina) particles with different diameters: Group 2 was blasted with 65-microm particles and Group 3 with 250-microm particles. The titanium specimens were sterilized and incubated in tubes containing a suspension of Streptococcus sanguis. The colony-forming units were counted before and after the application of the decontamination protocol. The arithmetic mean roughness (R(a)) per group was: Group 1, 0.17 microm +/- 0.01; Group 2, 1.14 microm +/- 0.15; and Group 3, 3.17 microm +/- 0.23. After the contamination period, Group 1 remained with 49 x 10(3) bacterial cells, and the bacterial concentrations of Groups 2 and 3 were 11 x 10(4) and 35 x 10(5), respectively. After the application of the decontamination protocol, no viable bacteria were detected. With the increase of the surface roughness, an exponential increase in bacterial cells was observed. The results showed that the decontamination protocol treatment with a high-pressure sodium bicarbonate device efficiently removed all bacterial cells in all surfaces tested. This indicates that high-pressure sodium bicarbonate spray should be used in the maintenance phase of implant treatment.

Bacterial Adhesion↗

Number and volume of islets transplanted in immunobarrier devices.

Immunobarrier devices may prevent immune destruction of transplanted islets, but there are concerns about survival within such devices. Islets were transplanted in diffusion chambers that employed two laminated polytetrafluoroethylene membranes held together with titanium rings. Five hundred syngeneic mouse islets placed in devices were transplanted into the epididymal fat pads of streptozotocin (STZ) diabetic mice (B6AF1). After 2 wk the devices were removed. Sections were made parallel to the membrane surface. Eight to 13 systematically selected sections of each device were analyzed by planimetry to determine the area of the device space and of the islets within that space. From these data we estimated total volume of the device, volume of islets, and number of islets in a device. The data were segregated into two groups: group I (blood glucose less than 100 mg/dL 2 wk after implantation), and group II (over 150 mg/dL). The volume (mean +/- SE) of devices implanted for 2 wk was 2.1 +/- 0.4 microL in group I and 2.2 +/- 0.2 microL in group II. The islet volume and number within devices were 0.30 +/- 0.06 and 0.17 +/- 0.01 microL, or 340 +/- 50 and 230 +/- 20 islets in group I and group II, respectively. The volume of fibrous tissue in devices was about 0.50 microL. About 10% of the islet tissue had central necrosis. The beta cell volume in a membrane device needed for cure is comparable to that required with islets under the kidney capsule (0.25-0.80 microL). The mass of islets contained within membrane devices needed to cure diabetes is equivalent to that of a graft in an optimal transplant site such as under the kidney capsule.

Animals↗

Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study.

BACKGROUND: Little is known about the mechanisms of bacterial interaction with implant materials in the oral cavity. A correlation between plaque accumulation and progressive bone loss around implants has been reported. Bacterial adhesion shows a direct positive correlation with surface roughness. Other surface characteristics also seem to be extremely important with regard to plaque formation. Different adhesion affinities of bacteria have been reported for different materials. The aim of this study was to characterize the percentage of surface covered by bacteria on commercially pure titanium and zirconium oxide disks. METHODS: Ten patients participated in this study. A removable acrylic device was adapted to the molar-premolar region, and commercially pure titanium (control) and zirconium oxide (test) disks were glued to the buccal aspect of each device. The surface roughness of titanium and test specimens was similar. After 24 hours, all disks were removed and processed for scanning electron microscopy, for the evaluation of the portion of surface covered by bacteria. RESULTS: In control specimens, the area covered by bacteria was 19.3% +/- 2.9; in test specimens, the area was 12.1% +/- 1.96. The disk surface covered by bacteria on test specimens was significantly lower than that of control specimens (P = 0.0001). CONCLUSION: Our results demonstrate that zirconium oxide may be a suitable material for manufacturing implant abutments with a low colonization potential.

Adult↗