PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HEART VALVES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Occurrence, diagnosis and treatment of thromboses of heart valve prostheses.

In the period from 1978 to 1985, the authors implanted a total of 667 Björk-Shiley heart valve prostheses. In the same period, they performed 6 times reoperation for thrombosis of these valves. There was one reoperation for thrombosis per 271 years of life with a valve prosthesis, i.e. 0.36% per patient year. All 6 reoperations were successful and there was until now no recurrence of thrombosis in any of the reoperated patients. All cases involved were thrombosis of the flat disc Björk-Shiley valve. There was now no thrombosis of convexo-concave types, which the authors have been using since 1981. The most important preventive measure against the development of thrombosis is strict observance and control of anticoagulation regimen. Thrombosis of a disc valve prosthesis can in most cases be diagnosed on the basis of the clinical picture and X-ray evidence of restricted disc mobility. Diagnosis of thrombosis is an indication for urgent reoperation, which is preferred to an uncertain attempt at thrombolysis.

Aortic Valve↗

Prevention of allograft heart valve failure in a rat model.

OBJECTIVE: Allograft heart valves are commonly used in cardiac surgery. Despite mounting evidence that these valves are immunogenic, leading to premature failure, current clinical practice does not attempt to minimize or control such a response. The objective of this study was to evaluate immune modulatory approaches to ameliorate allograft valve failure in a rat model. METHOD: Aortic valve grafts were implanted infrarenally into Lewis rat recipients (n = 32). There were 4 transplant groups: syngeneic grafts (Lewis to Lewis), untreated allografts (Brown Norway to Lewis), allograft recipients treated with cyclosporine (INN: ciclosporin) (10 mg/kg per day for 7 or 28 days), and allograft recipients treated with anti-alpha4 integrin and anti-beta2 integrin monoclonal antibodies for 7 days. At 7 and 28 days the valves were examined for structural integrity and cellular infiltration. RESULTS: Both cyclosporine and anti-alpha4/beta2 integrin treatment resulted in significant reduction in leaflet infiltration by macrophages (ED1(+)), T cells (CD3(+)), and CD8(+) T cells at 7 days with preservation of structural integrity when compared with control allografts. Twenty-eight days after implantation, daily treatment with cyclosporine preserved leaflet structural integrity and inhibited cellular infiltration. However, a short course of cyclosporine (7 days) failed to prevent destruction of the valves at 28 days. CONCLUSIONS: Immune modulatory approaches aimed at T-cell activation or trafficking decrease leaflet cellular infiltration and prevent allograft valve structural failure. However, short-course therapy does not appear to be sufficient and must be maintained to allow long-term preservation of leaflet structural integrity (28 days).

Analysis of Variance↗

Intracranial hemorrhage and infarction in anticoagulated patients with prosthetic heart valves.

In 1 year 6 patients with prosthetic heart valves (PHVs) treated with anticoagulants suffered intracranial hemorrhage. In 4, hemorrhage occurred into the site of a recent non-hemorrhagic infarction. In the others, both of whom had endocarditis, hemorrhages probably occurred as the result of rupture of a mycotic aneurysm. Five patients were treated with warfarin, 1 with heparin. In all patients the level of anticoagulant activity was greater than 1.5 times control. Five patients were in atrial fibrillation; 1 was hypertensive. The diagnosis of intracranial hemorrhage was made and its location and extent accurately determined by computed tomography (CT). Three patients underwent surgery and 2 are alive with only minor neurological deficits. Among the 3 patients who did not undergo surgery 2 died and 1 is alive with a moderate neurological deficit. The management of PHV patients with use of anticoagulants is discussed in terms of the mechanisms involved in intracranial bleeding. Emphasis is placed on prevention of emboli, discontinuation of anticoagulants once non-hemorrhagic infarction has occurred and the primacy of CT scan in diagnosis when hemorrhage is suspected. The special problems of anticoagulation in the presence of endocarditis are also discussed.

Aged↗

[Computerized hydrodynamic system "Flow" for testing artificial heart valves].

The computerized mock circulation system is described for analyzing the hydrodynamic characteristics of artificial heart valves. Flow studies have been carried out on 6 mechanical valves of various types. The volumetric flow, pressure upstream and downstream were measured and the mean systolic pressure drop and energy losses were calculated. The commercial model of the EMIKS valve shows much lower values of pressure drop and one of the smallest value of energy losses among the tested artificial heart valves.

Heart Valve Prosthesis↗

Candida parapsilosis: an unusual organism causing prosthetic heart valve infective endocarditis.

We report a case of Candida parapsilosis prosthetic heart valve infective endocarditis in a 67-year-old man. The infection was successfully treated with liposomal amphotericin B (AmBisome) and flucytosine. Surgical replacement of the infected valve was necessary. Recurrence was prevented with oral fluconazole 400mg daily as maintenance therapy. The patient remained well after 2 years of follow-up.

Aged↗

Banking cryopreserved heart valves in Europe: assessment of a 5-year operation in an international tissue bank in Brussels.

OBJECTIVE: The heart valve bank of the European Homograft Bank has been set up in 1988 to meet the growing demand of cardiac surgeons for various sized and quality controlled cryopreserved homografts. METHODS: Heart valve donors less than 60 years of age were classified in 3 categories: multiorgan donors with non transplantable hearts, recipients of cardiac transplantation and non beating heart cadavers with a warm ischemic time of less than 6 hours. Past history and biology were checked for transmissible diseases. Preparation, progressive freezing and storage in liquid nitrogen vapors, and quality control were according to the standards of the Belgian Ministry of Health. RESULTS: From end January 1989 to end May 1994, 989 homograft valves were cryopreserved (514 pulmonary, 475 aortic and 3 mitral) whereas 962 valves were discarded. The first cause of rejection being a major macroscopic lesion (41.48%). 138 hearts accepted at inspection were contaminated and 43 cases remained so after antibiotics. 38 cases were positive for hepatitis B or C. Complication at distribution and thawing included 10 instances of bag rupture and 15 of transversal fracture through the wall of the conduit. 477 aortic, 474 pulmonary valves as well as one mitral were implanted between May 1989 and May 1994, either for left or right ventricular outflow tract reconstruction. In the left ventricular outflow tract series 111 aortic and 23 pulmonary homograft valves were used in cases of native endocarditis, prosthetic endocarditis or recurrent endocarditis after homograft implantation. 9.6% of the requests could no be satisfied. Regular follow up information was available from 382 implants-40.1% only. CONCLUSIONS: The assessment of 5 years operation of the heart valve bank indicates: 1) the efficiency of selecting, cryopreserving and allocating quality controlled homograft valves from a large pool of donor hearts provided by a network of hospitals; 2) the difficulty of obtaining regular follow up information on the implants.

Belgium↗

Emergency heart valve replacement: an analysis of 170 patients.

The results of 170 emergency heart valve procedures performed during a 4 1/2-year period were analyzed. Five pathological groups of patients were recognized: those with infective endocarditis (Group 1, 28 patients); acute rheumatic carditis (Group 2, 43 patients); previous valve operation (Group 3, 29 patients); acute-on-chronic cardiac disease (Group 4, 67 patients); and miscellaneous conditions (Group 5, 3 patients). Mitral, aortic, and multiple valve procedures were performed on 58, 65, and 44 patients, respectively. The most common functional lesion was regurgitation. Hospital mortality was highest in Groups 3 (34%) and 4 (31%). By contrast, among the hospital survivors, the highest rate of attrition was in Group 2. Myocardial failure was the predominat cause of death. In view of the hopeless prognosis without operation, the 52% overall 3-year actuarial survival is a gratifying salvage. Unnecessary procrastination can only jeopardize the prospects for surgical cure.

Actuarial Analysis↗

Ten year clinical experience with the CarboMedics heart valve implants.

We reviewed the histories of 144 patients who underwent heart valve replacement with the CarboMedics prosthesis from 1990 to 2000. There were 74 males and 70 females, with a mean age of 52 years, including 69 aortic valve replacements, 48 mitral valve replacements, and 27 double (aortic and mitral) valve replacements. The mean duration of follow-up was 6.5 years. Early mortality was 7.6% (11 patients). Late deaths occurred in 14 patients, including cardiac-related late deaths in 9 and valve-related deaths in 3. The survival rate including early deaths was 84.7 +/- 3.2% at 5 years and 78 +/- 4.1% at 10 years. Preoperative New York Heart Association Class IV (p = 0.0001) was found to be a significant predictor of cardiac-related late death. Freedom rate from complications at 10 years were embolism 84.7 +/- 4.2% (linearized rate 1.8% per patient year), valve thrombosis 92.7 +/- 2.7% (linearized rate 0.8% per patient year), bleeding 95.6 +/- 2.6% (linearized rate 0.4% per patient year), reoperation 85.9 +/- 4% (linearized rate 1.5% per patient year), valve endocarditis 98.7 +/- 1.3% (linearized rate 0.1% per patient year), and nonstructural dysfunction 90 +/- 3.5% (linearized rate 1% per patient year). There was no structural deterioration. The early and long-term results with the CarboMedics heart valve implantation were acceptable, but valve thrombosis remains a concern in the present study. Further investigation for optimal anticoagulation therapy is necessary to reduce the incidence of valve thrombosis as well as embolic and bleeding complications.

Adult↗

Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.

OBJECTIVE: To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN: Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter in quiet rooms with either a decibel(A) filter or octave filters. The patients were asked about their complaints and examined physically. SETTING: The measurements were conducted in silent rooms of ear, nose, and throat departments. The patients had been operated on either in a university hospital or a community hospital. MAIN OUTCOME MEASURES: Sound pressures of frequency bands and sound pressures measured in dB(A) at various distances. Complaints registerd were: sleep disturbance, disturbance during daytime, "wants a less noisy prosthesis," and "can hear the closing click". PATIENTS: 143 patients after heart valve replacement with St Jude Medical (n = 35), Duromedics Edwards (n = 38), Carbomedics (n = 34) and Björk-Shiley Monostrut (n = 36) prostheses operated on between 1984 and 1988 were matched for valve position, ring size, and body surface area. RESULTS: Duromedics Edwards (33.5 (6) dB(A)) and Björk-Shiley Monostrut valves (31 (4) dB(A)) were significantly louder than St Jude Medical (24 (4) dB(A)) and Carbomedics (25 (6) dB(A)) prostheses (p = 0.0001) (mean (SD)). The louder valves were significantly more often heard by the patients (p = 0.0012) and caused more complaints both during sleep (p = 0.024) and during the daytime (p = 0.07). Patients with these valves were more likely to want a less noisy valve (p = 0.0047). Patients with symptoms were younger, had better hearing, and were more likely to be in sinus rhythm. As well as the type of prostheses, the valve diameter and body height also had an effect on sound emission. CONCLUSIONS: The intensity of the closing click of mechanical valve prostheses was significantly different for various designs. Patient complaints were related to the objectively measured sound pressure. Noise production should be considered when a mechanical valve is selected.

Adult↗

[Preparation of acellularized porcine heart valve and seeding of bovine aortic endothelial cells].

OBJECTIVE: To explore the possibility of detergent acellularized porcine heart valve serving as a scaffold for tissue engineering valve. METHODS: The porcine aortic valves were acellularized by use of trypsin-EDTA. Triton X-100, RNase and DNase treatment. Biomechanical characteristics of fresh valves and acellularized valve were tested; also fresh valves, acellularized valve and valves treated with method of bioprothetic treatment were implanted subcutaneously in rats; frequently seeded with bovine aortic endothelial cells(BAECs), and then cultured for 7 days. RESULTS: The acellularization procedure resulted in complete removal of the cellular components while the construction of matrix was maintained. The matrix could be successfully seeded with in vitro expanded BAECs, which formed a continuous monolayer on the surface. There is no significant difference of PGI2 secretion of BAECs between cells seeded onto the acellular leaflets and that onto the wells of 24-wells plate (P > 0.05). CONCLUSION: Acellularied porcine aortic valve can be applied as a scaffold to develop tissue engineering heart valve.

Animals↗

Antigen clearing from porcine heart valves with preservation of structural integrity.

Bioprostheses currently used for replacement of diseased cardiovascular tissue are preserved and partially protected from immune rejection through chemical fixation. However, after implantation, chemically preserved (fixed) material has limited durability and lacks the ability to revitalize through cellular ingrowth and remodeling. As an alternative to fixation, we aimed at thoroughly removing antigens from tissue, leaving an intact scaffold, suitable for integration and revitalization in the host. Extensive washing of porcine heart valves with a mixture of two detergents (SDS and Triton X-100) yielded an intact matrix devoid of cells and depleted of soluble proteins that was minimally immunogenic in rabbits. A detailed characterization of the biomechanics and durability of the tissue is under way. If the lack of immunogenicity is confirmed in primates, our results would suggest that a detergent-washed, unfixed porcine heart valve can be an attractive non-inflammatory scaffold for heart valve regeneration in humans.

Animals↗

EuroSCORE predicts long-term mortality after heart valve surgery.

BACKGROUND: The European System for Cardiac Operative Risk Evaluation (EuroSCORE) is the most rigorously evaluated scoring system in cardiac surgery. We sought to evaluate the performance of EuroSCORE in the prediction of long-term mortality in patients undergoing heart valve surgery. METHODS: Medical records of patients with isolated or combined heart valve surgery, who were discharged alive (n = 1035), were retrospectively reviewed. Their operative surgical risks were calculated according to EuroSCORE model (standard and logistic). Long-term survival data (mean follow-up 4.5 +/- 3.1 years) were obtained from the National Death Index. Kaplan-Meier curves of the quartiles of standard and logistic EuroSCORE were plotted. RESULTS: The estimated 5-year survival rates of the quartiles in the standard and logistic EuroSCORE model were: 90.0% +/- 2.3%, 85.1% +/- 2.3%, 64.8% +/- 3.3%, and 55.1% +/- 3.7% (p < 0.0001, log-rank test with adjustment for trend) and 90.4% +/- 2.2%, 86.4% +/- 2.5%, 66.9% +/- 3.3%, and 56.1% +/- 3.3% (p < 0.0001, log-rank test with adjustment for trend) respectively. The odds of death in the highest-risk quartile were 7.46- and 7.82-fold higher than the odds of death in the lowest-risk quartile for standard and logistic EuroSCORE respectively. CONCLUSIONS: EuroSCORE can be used to predict not only in-hospital mortality, for which it was originally designed, but also long-term mortality in the whole context of heart valve surgery. This outcome can be predicted using the standard EuroSCORE, which is very simple and easy in its calculation.

Aged↗

Pregnancy and successful delivery in a patient with triple heart valve prosthesis.

A 42-year-old patient had a history of rheumatic fever in childhood. At 37 years of age, she underwent a triple heart valve replacement; thereafter, she was followed with the administration of warfarin and methyldigoxin. Her third pregnancy occurred with the last menstruation on 12 March 1990. At the 30th gestational week, she was admitted to the Nagoya University Hospital for the control of anticoagulation and rest. She delivered by cesarean section a healthy male infant weighing 2070 g at 34 weeks of gestation. The post-operative course was uneventful. This report shows that a patient with a three heart valve prosthesis tolerated pregnancy well under intense medical supervision.

Adult↗

The significance of oral health and dental treatment for the postoperative outcome of heart valve surgery.

The objective of this study was to evaluate the significance of preoperative dental treatment for the development of complications in the form of infections during the first postoperative weeks after heart valve surgery. In one group of patients (n = 149), oral health was examined and dental treatment performed 3-6 months prior to heart valve surgery. In a second group (n = 104), oral health was examined postoperatively and these patients did not receive any dental treatment before surgery. Infections were recorded for all patients during the first three weeks after surgery and correlated to the dental status at the time of surgery. Sepsis or endocarditis occurred in 5.4% of the first group and in 1.9% of the second group. Freedom from all infections for the two groups was 55% and 56%, respectively. The results did not reveal any significant differences between the groups regarding patients' oral health at the primary oral examination. The frequencies of postoperative complications such as focal infections, fever and increased CRP were also found to be similar for both groups. The combined scores of complications were 2.1% and 1.8%, respectively. Data from the present study do not support the suggestion that dental intervention will decrease the rate of early complications following heart valve surgery.

Aged↗

Complete dynamic repopulation of decellularized heart valves by application of defined physical signals-an in vitro study.

OBJECTIVE: Cardiovascular tissue engineering is a novel concept to develop ideal heart valve substitutes. The objective of this study was to use decellularized porcine pulmonary valves, ovine cells and dynamic tissue culture to obtain viable and biomechanically stable constructs, resembling native aortic heart valves. METHODS: Endothelial cells and myofibroblasts were obtained from ovine carotid arteries. Porcine pulmonary valves were decellularized enzymatically, reseeded and cultured using a hydrodynamic bioreactor system over a time period of 9 or 16 days. Controls were grown over an equivalent time period under static conditions. Specimens of each valve were examined biochemically (cell proliferation, DNA, collagen, 4-hydroxyproline, elastin and glycosaminoglycans), histologically (hematoxylin-eosin, Movat-pentachrome and immunostains) and mechanically (radial and circumferential strength). RESULTS: Histology and biochemical assays demonstrated the removal of almost all cells after decellularization with preservation of the extracellular matrix. Recellularization under pulsatile conditions was significantly improved after 9 and 16 days compared to static conditions. Biochemical and mechanical analysis revealed a continuous increase of cell mass, collagen and elastin contents and strength under pulsatile culture conditions compared to significantly lower values in the static controls. CONCLUSION: This study demonstrated the superiority of the hydrodynamic approach of cellular reseeding to replace decellularized porcine heart valves with ovine cells with almost complete preservation of extracellular matrix integrity.

Animals↗

Thrombosis of mechanical heart valve prostheses: revisiting the role of fluoroscopy.

Prosthetic valve thrombosis is a rare but potentially fatal complication of heart valve replacement. Symptoms may be misleading, yet the condition may rapidly lead to death. A prompt diagnosis is therefore crucial. Ultrasound is the most often used technique for evaluating prosthesis dysfunction. We describe two cases of prosthesis thrombosis with negative Doppler results but with distinctly abnormal leaflet motion at fluoroscopy. A correct diagnosis would have been missed if the Doppler evaluation alone was relied on. Fluoroscopy should always form part of the diagnostic work-up in patients with artificial heart valves.

Coronary Thrombosis↗

[Unusual case: injury of the 4 heart valves in a patient with old heart injury caused by fire arm. Review of the literature].

We review the literature on heart wounds. Along the history surgeons regarded heart wounds as forbidden place for therapeutic approach. We present a patient who sustained a bullet wound to the heart and two years later 3 knife' stabs in the same place injuring its 4 valves and inducing 2 fistulae: one from the aorta to the pulmonary artery, the other from left-ventricle and the pulmonary artery. Surgery was successful in repairing the damage without the need of valve replacement.

Adult↗