PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Silicon Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Evidence of a charge-density threshold for optimum efficiency of biocidal cationic surfaces.

The deposition of organic monolayers containing quaternary ammonium groups has been shown by many authors to confer biocidal properties on a large variety of solid surfaces. In a search for the controlling factors, the authors have grafted quaternized poly(vinylpyridine) chains on glass surfaces by two different methods and varied the charge density within the organic layer between 10(12) and 10(16) positive charges per cm2. The measurements show that this parameter has a large influence on the killing efficiency. Bacterial death occurs in less than 10 min in the quiescent state above a threshold value. The value is smaller for bacteria in the growth state. It also depends on the bacterial type. An electrostatic mechanism based on the exchange of counterions between the functionalized cationic surface and the bacterial membrane is proposed and appears consistent with the results.

Anti-Bacterial Agents↗

Lu2SiO5 by single-crystal X-ray and neutron diffraction.

The structure of dilutetium silicon pentaoxide, Lu2SiO5, has isolated ionic SiO4 tetrahedral units and non-Si-bonded O atoms in distorted OLu4 tetrahedra. The OLu4 tetrahedra form edge-sharing infinite chains and double O2Lu6 tetrahedra along the c axis. The edge-sharing chains are connected to the O2Lu6 double tetrahedra by isolated SiO4 units. The structure has been determined by neutron diffraction.

Crystallography, X-Ray↗

Pseudoepitaxial transrotational structures in 14 nm-thick NiSi layers on [001] silicon.

In a system consisting of two different lattices, structural stability is ensured when an epitaxial relationship occurs between them and allows the system to retain the stress whilst avoiding the formation of a polycrystalline film. The phenomenon occurs if the film thickness does not exceed a critical value. Here we show that in spite of its orthorhombic structure, a 14 nm-thick NiSi layer can three-dimensionally adapt to the cubic Si lattice by forming transrotational domains. Each domain arises by the continuous bending of the NiSi lattice, maintaining a close relationship with the substrate structure. The presence of transrotational domains does not cause a roughening of the layer, but instead it improves the structural and electrical stability of the silicide in comparison with a 24 nm-thick layer formed using the same annealing process. These results have relevant implications for the thickness scaling of NiSi layers which are currently used as metallizations of electronic devices.

Crystallography, X-Ray↗

Development of a new geometrical form of micropipette: electrical characteristics and an application as a potassium ion selective electrode.

Using a mix of thermal and anodic bonding together with microlithographic techniques, the safe transference of a Si3N4 film with a pore (diameter down to 1 micron) to a glass tube tip (external diameter 800 microns) was accomplished, yielding a new geometrical form of micropipette. Compared with conventional glass micropipettes the device has shown lower resistance, more stable capacitance (independent of the tip immersion depth), tip potential closer to that of a salt bridge, and a simplified filling process. Using this device as a potassium ion selective electrode (ISE), a faster response time ISE was achieved. These features indicate that the new device can advantageously substitute the conventional glass micropipettes when cell impalement is not required.

Electric Conductivity↗

Characteristics of silicon nitride after O2 plasma surface treatment for pH-ISFET applications.

Silicon nitride (Si3N4) sensing gate pH-ion-selective field effect transistors (ISFETs) were treated by 2.54-GHz microwave O2 plasma, the results show the ISFET sensitivity has an advantage up to 24% increment after the plasma treatment. Electron spectroscopy for chemical analysis (ESCA) is used to make sure that the plasma treatment is not just a native oxide cleaning procedure. The samples, which were immobilized with glutaraldehyde used as a bifunctional reagent and 3-aminopropyItriethoxysilane used as an adhesion promoter were studied. The binding force between the glucose oxidase and glutaraldehyde immobilized samples, and the element concentrations of nitrogen in 3-aminopropyltriethoxysilane immobilized samples are higher which were treated by plasma.

Glucose Oxidase↗

Cantilevers and tips for atomic force microscopy.

The cantilever and the tip are at the centerpiece of the AFM. Properties such as the cantilever stiffness and resonant frequency, tip shape and sharpness, and material characteristics determine the mode of operation of the AFM and the type of experiments and measurements that can be performed. The possibility of batch fabricating cantilevers has permitted the fabrication and characterization of specialized tips for a variety of experiments. We believe that the use of new materials and tip shapes will allow new applications for the AFM in the future.

Aluminum↗

Fast and precise positioning of single cells on planar electrode substrates.

For cell biosensors and for studying neural networks using planar electrode substrates, a suitable technique for positioning single cells on electrodes was needed. We reported a new method for fast and efficient positioning of single cells on ring electrodes by controlled suction through holes. We described the microfabrication of electrode substrates with microholes and the cell positioning procedure. L929 cells and Neuro 2A cells could be positioned in parallel without cell damage.

Aluminum↗

Vibration maps of capacitive micromachined ultrasonic transducers by laser interferometry.

In this letter, a 1.8-mm x 1.8-mm capacitive micromachined ultrasonic transducer (CMUT) element is experimentally characterized by means of optical measurements. Optical displacement measurements provide information on the resonant behavior of the single membranes and also allow us to investigate the dispersion in the frequency spectrum of adjacent membranes. In addition, higher order mode shapes are observed, showing that either symmetrical or asymmetrical modes are excited in CMUT membranes. Laser interferometry vibration maps, combined with quantitative displacement measurements, provide information about the quality and repeatability of the fabrication process, which is a basic requirement for 2-D array fabrication for ultrasound imaging.

Coated Materials, Biocompatible↗

Finite element analysis of underwater capacitor micromachined ultrasonic transducers.

A simple electro-mechanical equivalent circuit model is used to predict the behavior of capacitive micromachined ultrasonic transducers (cMUT). Most often, cMUTs are made in silicon and glass plates that are in the 0.5 mm to 1 mm range in thickness. The equivalent circuit model of the cMUT lacks important features such as coupling to the substrate and the ability to predict cross-talk between elements of an array of transducers. To overcome these deficiencies, a flnite element model of the cMUT is constructed using the commercial code ANSYS. Calculation results of the complex load impedance seen by single capacitor cells are presented, then followed by a calculation of the plane wave real load impedance seen by a parallel combination of many cells that are used to make a transducer. Cross-talk between 1-D array elements is found to be due to two main sources: coupling through a Stoneley wave propagating at the transducer-water interface and coupling through Lamb waves propagating in the substrate. To reduce the cross-talk level, the effect of structural variations of the substrate are investigated, which includes a change of its thickness and etched trenches or polymer walls between array elements.

Artifacts↗

Narrowband impedance matching layer for high efficiency thickness mode ultrasonic transducers.

A new matching layer design concept has been proposed for narrowband continuous wave (CW) devices. Analysis has shown that the mechanical impedance of a resonant-type transducer in thickness mode CW operation does not equal its acoustic impedance rhoVs but roughly equals rhoVs/Q, where p is density, Vs is acoustic velocity, and Q is the mechanical quality factor. The value of rhoVs/Q is much lower than the acoustic impedance of water for any transducer material, including lead zirconium titanate (PZT), single crystals, or polyvinylidene fluoride (PVDF). With this new approach, the impedance of the matching layer must also be between water and pVs/Q, but there are few such practical low impedance materials. To realize equivalent low impedance structure, a novel double layer design is presented: a relatively low impedance material (such as polyethylene or polyurethane) on the inside and a relatively high impedance material (such as polyester or metal) on the outside. A high power CW transducer structure was designed and fabricated with PVDF-TrFE (polyvinylidene fluoride trifluoroethylene) to operate at 1.4 MHz. The basic quarter wavelength resonator structure is 0.7-mm alumina/0.2-mm piezo-polymer/0.25-mm polyester, and the matching section is 0.2-mm polyurethane and 0.25-mm polyester. A maximum power output of 6 to 9 W/cm2 with conversion efficiency of 30 to 35% was observed. For the transducer without matching section, the observed power was 3 to 4 W/cm2. Mason's model analyses (1) predict that the traditional matching layer is for broadband purposes and reduces output power both for PZT and PVDF-TrFE (2); this new matching scheme can be applied to PZT high power transducer. This high efficiency technique has application in various CW systems, such as Doppler sensors, interferometry, phase-sensitive imaging, or high energy focused beam systems.

Aluminum↗

Cutting effectiveness of diamond points on commercial core composite resins and cements.

In dental clinics, composite resin and cement cores are routinely cut and polished during abutment tooth preparation. To identify their characteristics during cutting, weight-load cutting tests were performed on eight commercial core composites and two cements, using diamond points driven by an air-turbine handpiece. It became evident that the cutting effectiveness of the diamond points on nine workpieces exceeded that on natural tooth dentine, while that on one composite containing Si3,N4 filler was analogous to that on dentine. With continued use, the cutting effectiveness of the diamond point on all workpieces gradually declined. SEM observations revealed that diamond particles of the diamond point wore out with repeated use. It is clinically advised to select the core material with material characteristics during cutting and mechanical strength similar to those of dentin.

Animals↗

Solid-phase synthesis of oxytocin using iodotrichlorosilane as Boc deprotecting agent.

Deprotection of the tert-butoxycarbonyl group during solid-phase synthesis of peptides can be conveniently and efficiently carried out using a neutral reagent, silicon tetrachloride/sodium iodide (iodotrichlorosilane). This simple and rapid method has been advantageously employed during the solid-phase synthesis of the pituitary hormone, oxytocin.

Amino Acid Sequence↗

Proton translocation and ATP formation coupled to electron transport from H2O to the primary acceptor of photosystem 2.

1. The rate of electron transport from H2O to silicomolybdate in the presence of 3-(3-4-dichlorophenyl)-1,1-dimethylurea (diuron) (which involves the oxygen-evolving enzyme, the photochemistry of photosystem 2 and the primary electron acceptor of photosystem 2) is controlled by internal pH. This is based on the shift of the pH profile of the rate of electron transport upon addition of uncouplers, or by using EDTA-treated chloroplasts. Both stimulation and inhibition of electron transport by addition of uncouplers (depending on external pH) could be observed. These effects are obtained in the diuron-insensitive photoreductions of either silicomolybdate or ferricyanide. These experiments provide strong evidence that a proton translocating site exists in the sequence of the electron transport H2O leads to Q (the primary acceptor of photosystem 2). 2. The photoreduction of silicomolybdate in the presence of diuron causes the formation of delta pH. The value of delta pH depends on the external pH and its maximal value was shown to be 2.4. The calculated internal pH at different external pH values was found to be rather constant, namely between 5.1 -- 5.2. 3. Electron transport from H2O to silicomolybdate (in the presence of diuron) does not support ATP formation. It is suggested that this is due to the fact that the delta pH formed is below the "threshold" delta pH required for the synthesis of ATP. By adding an additional source of energy in the form of a dark diffusion potential created in the presence of K+ and valinomycin, significant amounts of ATP are formed in this system.

Adenosine Triphosphate↗

Evidence for direct amelogenin-target cell interactions using dynamic force spectroscopy.

Increasing evidence suggests that amelogenin, long held to be a structural protein of developing enamel matrix, may also have cell signaling functions. However, a mechanism for amelogenin cell signaling has yet to be described. The aim of the present study was to use dynamic chemical force spectroscopy to measure amelogenin interactions with possible target cells. Full-length amelogenin (rM179) was covalently attached to silicon nitride AFM tips. Synthetic RGD peptides and unmodified AFM tips were used as controls. Amelogenin-RGD cell binding force measurements were carried out using human periodontal ligament fibroblasts (HPDF) from primary explants and a commercially available osteoblast-like human sarcoma cell line as the targets. Results indicated a linear logarithmic dependence between loading rate and unbinding force for amelogenin-RGD target cells across the range of loading rates used. For RGD controls, binding events measured at 5.5 nN s-1 force loading rate resulted in a mean force of 60 pN. Values for amelogenin-fibroblast and amelogenin-osteoblast-like cell unbinding forces, measured at similar loading rates, were 50 and 55 pN, respectively. These data suggest that amelogenin interacts with potential target cells with forces characteristic of specific ligand-receptor binding, suggesting a direct effect for amelogenin at target cell membranes.

Amelogenin↗

The inventory of interstellar materials available for the formation of the solar system.

Tremendous progress has been made in the field of interstellar dust in recent years through the use of telescopic observations, theoretical studies, laboratory studies of analogs, and the study of actual interstellar samples found in meteorites. It is increasingly clear that the interstellar medium (ISM) contains an enormous diversity of materials created by a wide range of chemical and physical processes. This understanding is a far cry from the picture of interstellar materials held as recently as two decades ago, a picture which incorporated only a few generic types of grains and few molecules. In this paper, I attempt to review some of our current knowledge of the more abundant materials thought to exist in the ISM. The review concentrates on matter in interstellar dense molecular clouds since it is the materials in these environments from which new stars and planetary systems are formed. However, some discussion is reserved for materials in circumstellar environments and in the diffuse ISM. The paper also focuses largely on solid materials as opposed to gases since solids contain a major fraction of the heavier elements in clouds and because solids are most likely to survive incorporation into new planetary systems in identifiable form. The paper concludes with a discussion of some of the implications resulting from the recent growth of our knowledge about interstellar materials and also considers a number of areas in which future work might be expected to yield important results.

Astronomy↗

Compact fiber-delivered Cr:forsterite laser for nonlinear light microscopy.

We demonstrate a compact and self-starting fiber-delivered femtosecond Cr:forsterite laser for nonlinear light microscopy. A semiconductor saturable absorber mirror provides the self-starting mechanism and maintains long-term stability in the laser cavity. Four double-chirped mirrors are employed to reduce the size of the cavity and to compensate for group velocity dispersion. Delivered by a large-mode-area photonic crystal fiber, the generated laser pulses can be compressed down to be with a nearly transform-limited pulse width with 2.2-nJ fiber-output pulse energy. Based on this fiber-delivered Cr:forsterite laser source, a compact and reliable two-photon fluorescence microscopy system can thus be realized.

Chromium↗

Temperature dependence of commercially available diode detectors.

Temperature dependence of commercially available n- and p-type diodes were studied experimentally under both high instantaneous dose rate (pulsed) and low dose rate (continuous) radiation. The sensitivity versus temperature was measured at SSD = 80 or 100 cm, 10 x 10 cm2, and 5 cm depth in a 30 x 30 x 30 cm3 water phantom between 10 degrees C and 35 degrees C. The response was linear for all the diode detectors. The temperature coefficient (or sensitivity variation with temperature, svwt) was dose rate independent for preirradiated diodes. They were (0.30 +/- 0.01)%/degrees C, (0.36 +/- 0.03)%/degrees C, and (0.29 +/- 0.08)%/degrees C for QED p-type, EDP p-type, and Isorad n-type diodes, respectively. The temperature coefficient for unirradiated n-type diodes was different under low dose rate [(0.16 to 0.45)%/degrees C, continuous, cobalt] and high instantaneous dose rate [(0.07 +/- 0.02)%/degrees C, pulsed radiation]. Moreover, the temperature coefficient varies among individual diodes. Similarly, the temperature coefficient for a special unirradiated QED p-type diode was different under low dose rate (0.34%/degrees C, cobalt) and high instantaneous dose rate [(0.26 +/- 0.01)%/degrees C, pulsed radiation]. Sufficient preirradiation can eliminate dose rate dependence of the temperature coefficient. On the contrary, preirradiation cannot eliminate dose rate dependence of the diode sensitivity itself.

Phantoms, Imaging↗

A-Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement.

Amorphous silicon (a-Si:H) flat-panel (FP) imaging systems have recently become commercially available for both chest and mammographic imaging applications. It has been shown that this new detector technology offers better image quality and various operational advantages over the computed radiography (CR) which to date has been the most widely implemented and used digital radiography technique. However, most image quality measurements reported on flat-panel systems have been performed on prototype systems in laboratories while those for CR systems were typically independently performed and reported on in separate studies. To directly compare the two technologies, we have measured the image properties for a commercial amorphous silicon/cesium iodide [a-Si:H/CsI(Tl)] flat-panel based digital chest system and a commercial CR system under clinical imaging conditions. In this paper, measurements of image quality metrics, including the modulation transfer functions (MTFs), noise power spectra (NPSs), and detective quantum efficiencies (DQEs), for the FP and CR systems are presented and compared. Methods and issues related to these measurements are discussed. The results show that the flat-panel system has slightly lower MTF but significantly higher DQEs than the CR system. The DQEs of the flat-panel system were found to increase with the exposure while those of the CR system decrease slightly with the exposure.

Humans↗