Fetal tissue engineering: chest wall reconstruction.

BACKGROUND/PURPOSE: This study was aimed at applying fetal tissue engineering to chest wall reconstruction. METHODS: Fetal lambs underwent harvest of elastic and hyaline cartilage specimens. Once expanded in vitro, fetal chondrocytes were seeded onto synthetic scaffolds, which then were placed in a bioreactor. After birth, fetal cartilage constructs (n = 10) were implanted in autologous fashion into the ribs of all lambs (n = 6) along with identical, but acellular scaffolds, as controls (n = 6). Engineered and acellular specimens were harvested for analysis at 4 to 12 weeks postimplantation. Standard histology and matrix-specific staining were performed both before implantation and after harvest on all constructs. RESULTS: Regardless of the source of chondrocytes, all fetal constructs resembled hyaline cartilage, both grossly and histologically, in vitro. In vivo, engineered implants retained hyaline characteristics for up to 10 weeks after implantation but remodeled into fibrocartilage by 12 weeks postoperatively. Mononuclear inflammatory infiltrates surrounding residual PGA/PLLA polymer fibers were noted in all specimens but most prominently in the acellular controls. CONCLUSIONS: Engineered fetal cartilage can provide structural replacement for at least up to 10 weeks after autologous, postnatal implantation in the chest wall. Fetal tissue engineering may prove useful for the treatment of severe congenital chest wall defects at birth.

Animals↗

Tissue-engineered cartilage as a graft source for laryngotracheal reconstruction: a pig model.

OBJECTIVE: To evaluate the feasibility of using tissue-engineered cartilage for laryngotracheal reconstruction in the pig model. DESIGN: Auricular cartilage was harvested from 3 young swine. The cartilage was digested, processed, and suspended and a cell culture was obtained. The cells were then suspended in 3 mL of a 30% solution of a biodegradable polymer (Pluronic F-127) (polyethylene oxide/polypropylene oxide copolymer) at a cellular concentration of 50 x 10(6) cells/mL. This suspension was then implanted subcutaneously into each pig's dorsum. Eight weeks after implantation, the cartilage was harvested with the surrounding perichondrial capsule. An anterior cartilage graft laryngotracheal reconstruction was performed. Bronchoscopy was performed at 3 postoperative weeks to demonstrate airway patency. The animals were killed at 3 months, and specimens were obtained for histological analysis. SETTING: An animal research facility. SUBJECTS: Three young Yorkshire swine. RESULTS: All 3 pigs survived to the 3-month postoperative interval with no evidence of stridor or airway distress. Interval bronchoscopy revealed a normal patent airway with a mucosalized graft. Histopathologic analysis revealed incorporation of the tissue-engineered cartilage graft in the cricoid area, which correlated with results of bronchoscopic evaluation. CONCLUSION: Tissue-engineered auricular cartilage served as a viable graft in the pig model and might be an alternative cartilage source for laryngotracheal reconstruction.

Animals↗

[Experimental study of tissue engineered bone with coralline hydroxyapatite as scaffolds].

OBJECTIVE: To investigate the feasibility of coralline hydroxyapatite (CHA) as scaffolds in bone tissue engineering. METHODS: The bone marrow stromal cells from 4-month New Zealand rabbits were harvested and cultured in vitro. After multiplied, dexamethasone was used to promote the osteoblastic phenotype of the cells. The cells were harvested and then seeded into CHA. By means of tissue engineering technique, osteoblastic cells/CHA complex were formed. The complex were implanted subcutaneously in nude mice. The CHA alone was implanted as control. Bone regeneration was assessed 6, 8 weeks after implantation by histological and roentgenographic analysis. RESULTS: After six weeks of implantation, x-ray film showed high-density signal, osteoid tissue formed under histological examination. Large amount of new bone were formed and connected to trabecularism 8 weeks after implantation in the experimental group. While in the control group, there were no new bone formation, but amount of fiber tissue grew into the pore of CHA 8 weeks after implantation. CONCLUSION: CHA may be used as a good scaffold material for bone tissue engineering.

Animals↗

Reconstruction of mandibular defects with autologous tissue-engineered bone.

PURPOSE: Maxillofacial reconstructive procedures often require bone graft harvesting, which results in donor site morbidity; the use of tissue-engineered bone would eliminate this problem. In this study, a novel scaffold design and new fabrication protocol were used to produce autologous tissue-engineered constructs (scaffolds seeded with cells) to reconstruct segmental mandibular defects in a minipig model. MATERIALS AND METHODS: Porcine mesenchymal stem cells were isolated from the ilium. They were expanded in culture and seeded onto poly-dl-lactic-coglycolic acid scaffolds. The constructs were placed in a bioreactor and incubated for 10 days in medium and osteogenic supplements. Four full-thickness bony defects (2 x 2 cm) were created in the same pig's mandible. The constructs (n = 2) were placed into 2 of the defects as autologous grafts. One unseeded scaffold and 1 empty defect served as controls. At 6 weeks postimplantation, the pig was sacrificed, the mandible was harvested, and the grafted sites were evaluated by clinical, radiographic, and histologic methods. RESULTS: The construct-implanted defects appeared to be filled with hard tissue resembling bone, whereas controls were filled with fibrous tissue. Radiographically, the tissue-engineered constructs were uniformly radiodense with bone distributed throughout. The interface between native bone and constructs was indistinct. Complete bone ingrowth was not observed in control defects. Osteoblasts, osteocytes, bone trabeculae, and blood vessels were identified throughout the defects implanted with constructs. CONCLUSION: This "proof-of-principle" study indicates that porcine mandibular defects can be successfully reconstructed by in vitro cultured autologous porcine mesenchymal stem cells on a biodegradable polymer scaffold with penetration of bone and blood vessels.

Animals↗

[Expression of endogenic bone morphogenetic protein in repairing rabbit skull with tissue engineering technique].

OBJECTIVE: To explore the distribution and effect of endogenic bone morphogenetic protein (BMP) in repairing rabbit skull with tissue engineered bone. METHODS: The autologous osteoblast-like cells were instantly implanted onto polyglycolic acid (PGA) matrix coated with collagen. The rabbit skull defect models were established by resection of bilateral 1.5 cm x 1.0 cm full-thickness parietal bone in 18 New Zealand rabbits, which were randomly divided into two groups. In one group, the composite of osteoblast- like cells and PGA matrix were grafted into the defect on one side of the skull as experimental group I, leaving the same defect area on the other side as control group without any graft implanted. In the other group, simply PGA was done in the same way as experimental group II. The tissue samples were harvested at 3, 8 and 14 days postoperatively and examined by histological and immunohistochemistry methods. The concentrations of BMP in different regions of the samples were measured using computer image analysis system. RESULTS: After 3 days of operation, the BMP positive cells were found in the matrix of experimental group I. At 8 days postoperatively, the formation of new bone on experimental group I was prior to that of experimental group II and control group. On the 14th day, bone trabecula was formed on the experimental group I, but there was only fibrous tissue on control group. The concentration of BMP on the experimental group I and II were higher than that of corresponding region on control side. CONCLUSION: The osteoblast-like cells instantly implanted onto PGA matrix can synthesize and secrete BMP. It may be one of the reasons of tissue engineered bone inducing new bone regeneration that localizing endogenic BMP in bone defect area, increasing the concentration of endogenic BMP and improving its distribution by tissue engineering technique.

Animals↗

The role of cell seeding density and nutrient supply for articular cartilage tissue engineering with deformational loading.

OBJECTIVE: Functional tissue engineering (FTE) of articular cartilage involves the use of physiologically relevant mechanical signals to encourage the growth of engineered constructs. The goal of this study was to determine the utility of deformational loading in enhancing the mechanical properties of chondrocyte-seeded agarose hydrogels, and to investigate the role of initial cell seeding density and nutrient supply in this process. DESIGN: Chondrocyte-seeded agarose hydrogels were cultured in free-swelling conditions or with intermittent deformational loading (10% deformation, 1 Hz, 1 h on/ 1 h off, 3 h per day, five days per week) over a two-month culture period. Disks were seeded at lower (10 million cells/ml) and higher (60 million cells/ml) seeding densities in the context of a greater medium supply than previous studies (decreasing the number of cells/ml feed medium/day) and with an increasing concentration of fetal bovine serum (10 or 20% FBS). RESULTS: Under these more optimal nutrient conditions, at higher seeding densities and high serum concentration (20% FBS), dynamically loaded constructs show >2-fold increases in material properties relative to free-swelling controls. After two months of culture, dynamically loaded constructs achieved a Young's modulus of approximately 185 kPa and a dynamic modulus (at 1 Hz) of approximately 1.6 MPa, with a frequency dependent response similar to that of the native tissue. These values represent approximately 3/4 and approximately 1/4 the values measured for the native tissue, respectively. While significant differences were found in mechanical properties, staining and bulk measurements of both proteoglycan and collagen content of higher seeding density constructs revealed no significant differences between free-swelling and loading groups. This finding indicates that deformational loading may act to increase material properties via differences in the structural organization, the production of small linker ECM molecules, or by modulating the size of macromolecular proteoglycan aggregates. CONCLUSIONS: Taken together, these results point to the utility of dynamic deformational loading in the mechanical preconditioning of engineered articular cartilage constructs and the necessity for increasing feed media volume and serum supplementation with increasing cell seeding densities.

Animals↗

Biomechanical factors in tissue engineered meniscal repair.

Damage to the meniscus after trauma or injury is associated with detrimental changes in joint function that can lead to pain, disability, and degenerative joint changes. Recently, tissue engineering strategies for meniscal repair have been suggested including using biocompatible grafts as a substrate for regeneration, and cellular supplementation to promote remodeling and healing. Little is known, however, about the contributions of these novel repair strategies to restoration of normal meniscal function. Biomechanical factors play a role in the design and synthesis of tissue engineered biomaterials and bioreactors, and also are important for evaluating the efficacy of these new strategies for restoring normal meniscal function. In this report, an overview is presented of biomechanical factors that are critical to meniscal function followed by a review of biomechanical considerations for the design and evaluation of tissue engineered strategies for meniscal repair. Recommendations for future study of biomechanical factors in tissue engineered meniscal repair also are provided.

Animals↗

Photocrosslinkable polyvinyl alcohol hydrogels that can be modified with cell adhesion peptides for use in tissue engineering.

Photoactive polyvinyl alcohol hydrogels (PVA) have been investigated for use as tissue engineering scaffolds. These materials allow in situ polymerization for minimally invasive implantation methods. The mechanical properties of these materials can be tailored for a variety of soft tissue applications. The Young's modulus and ultimate tensile strength of PVA hydrogels are increased with increasing polymer concentration, and highly elastic hydrogels can be formed by altering the number of crosslinkable groups per chain. Fibroblasts homogeneously seeded within 3 mm thick PVA hydrogels remained viable throughout 2 weeks in culture, with no differences in viability across the thickness of the hydrogel. Cells seeded within the PVA hydrogels also produce extracellular matrix proteins, as indicated by the production of hydroxyproline during culture. Intrinsically cell non-adhesive, these PVA hydrogels were functionalized with the cell-adhesive peptide RGDS and found to support the attachment and spreading of fibroblasts in a dose-dependent manner. These results suggest that photopolymerizable PVA hydrogels are promising for tissue engineering applications.

Biocompatible Materials↗

Cartilage tissue engineering: controversy in the effect of oxygen.

Articular cartilage lacks the ability to repair itself and consequently defects in this tissue do not heal. Tissue engineering approaches, employing a scaffold material and cartilage producing cells (chondrocytes), hold promise for the treatment of such defects. In these strategies the limitation of nutrients, such as oxygen, during in vitro culture are of major concern and will have implications for proper bioreactor design. We recently demonstrated that oxygen gradients are indeed present within tissue engineered cartilaginous constructs. Interestingly, oxygen, besides being an essential nutrient, is also a controlling agent of developmental processes including cartilage formation. However, the specific role of oxygen in these processes is still obscure despite the recent advances in the field. In particular, the outcome of published investigations is inconsistent regarding the effect of oxygen tension on chondrocytes. Therefore, this article describes the possible roles of oxygen gradients during embryonic cartilage development and reviews the data reported on the effect of oxygen tension on in vitro chondrocyte proliferation and differentiation from a tissue engineering perspective. Furthermore, possible causes for the variance in the data are discussed. Finally, recommendations are included that may reduce the variation, resulting in more reliable and comparable data.

Animals↗

Optimising bioactive glass scaffolds for bone tissue engineering.

A 3D scaffold has been developed that has the potential to fulfil the criteria for an ideal scaffold for bone tissue engineering. Sol-gel derived bioactive glasses of the 70S30C (70 mol% SiO2, 30 mol% CaO) composition have been foamed to produce 3D bioactive scaffolds with hierarchical interconnected pore morphologies similar to trabecular bone. The scaffolds consist of a hierarchical pore network with macropores in excess of 500 microm connected by pore windows with diameters in excess of 100 microm, which is thought to be the minimum pore diameter required for tissue ingrowth and vasularisation in the human body. The scaffolds also have textural porosity in the mesopore range (10-20 nm). The scaffolds were sintered at 600, 700, 800 and 1000 degrees C. As sintering temperature was increased to 800 degrees C the compressive strength increased from 0.34 to 2.26 MPa due to a thickening of the pore walls and a reduction in the textural porosity. The compressive strength is in the range of that of trabecular bone (2-12 MPa). Importantly, the modal interconnected pore diameter (98 microm) was still suitable for tissue engineering applications and bioactivity is maintained. Bioactive glass foam scaffolds sintered at 800 degrees C for 2 h fulfill the criteria for an ideal scaffold for tissue engineering applications.

Biocompatible Materials↗

Formulation of PEG-based hydrogels affects tissue-engineered cartilage construct characteristics.

The limited supply of cartilage tissue with appropriate sizes and shapes needed for reconstruction and repair has stimulated research in the area of hydrogels as scaffolds for cartilage tissue engineering. In this study we demonstrate that poly(ethylene glycol) (PEG)-based semi-interpenetrating (sIPN) network hydrogels, made with a crosslinkable poly(ethylene glycol)-dimethacrylate (PEGDM) component and a non-crosslinkable interpenetration poly(ethylene oxide) (PEO) component, and seeded with chondrocytes support cartilage construct growth having nominal thicknesses of 6 mm and relatively uniform safranin-O stained matrix when cultured statically, unlike constructs grown with prefabricated macroporous scaffolds. Even though changing the molecular weight of the PEO from 100 to 20 kDa reduces the viscosity of the precursor polymer solution, we have demonstrated that it does not appear to affect the histological or biochemical characteristics of cartilaginous constructs. Extracellular matrix (ECM) accumulation and the spatial uniformity of the ECM deposited by the embedded chondrocytes decreased, and hydrogel compressive properties increased, as the ratio of the PEGDM:PEO in the hydrogel formulation increased (from 30:70 to 100:0 PEGDM:PEO). Total collagen and glycosaminoglycan contents per dry weight were highest using the 30:70 PEGDM:PEO formulation (24.4+/-3.5% and 7.1+/-0.9%, respectively). The highest equilibrium compressive modulus was obtained using the 100:0 PEGDM:PEO formulation (0.32+/-0.07 MPa), which is similar to the compressive modulus of native articular cartilage. These results suggest that the versatility of PEG-based sIPN hydrogels makes them an attractive scaffold for tissue engineering of cartilage.

Journal Article↗

Solvent-assisted room-temperature compression molding approach to fabricate porous scaffolds for tissue engineering.

This study investigated the room-temperature compression molding/particle leaching approach to fabricate three-dimensional porous scaffolds for tissue engineering. Scaffolds with anatomical shapes (ear, joint, tube, cylinder) were made from biodegradable poly(D,L-lactide) and poly[(D,L-lactide)-co-glycolide]. The utility of this room-temperature compression approach comes from the effect of solvent assistance, but the tendency for post-molding scaffold shrinkage is a problem unique to this method and is thus examined with emphasis in this paper. Scaffold shrinkage was found to be tolerable under normal fabrication conditions with high salt contents, which is just what the preparation of highly porous scaffolds requires. Furthermore, the resultant porosities after salt leaching were measured as well as the initial scaffold shrinkages after solvent evaporation, and the relation between them was revealed by theoretical analysis and confirmed by comparison with experimental measurements. The pores were interconnected, and porosity can exceed 90%. The effects of porosity on the mechanical properties of porous scaffolds were also investigated. This convenient fabrication approach is a prospective method for the tailoring of porous scaffolds for a variety of possible applications in tissue engineering and tissue reconstruction.

Biocompatible Materials↗

Tissue engineering with muscle-derived stem cells.

Tissue engineering and cell therapy approaches aim to take advantage of the repopulating ability and plasticity of multipotent stem cells to regenerate lost or diseased tissue. Researchers continue to investigate stem cells in mature tissues and demonstrate the potential ability of organ-specific cells to differentiate into multiple lineages. One stem cell that displays such promise is the muscle-derived stem cell (MDSC). Data supporting the existence of MDSCs have emerged as part of investigations to improve myoblast cell transplantation for the treatment of muscular dystrophies. As these efforts continue, the potential for MDSC-based therapy for other musculoskeletal injuries, as well as for cardiac and smooth muscle injuries, is currently being explored.

Animals↗

Lack of calcification of tissue engineered heart valves in juvenile sheep.

The presence of viable endothelial cells may support longer durability and the absence of calcification in valve prostheses. This study shows the development of a tissue engineered heart valve, constructed from viable autologous endothelial cells on an acellular matrix and its evaluation in juvenile sheep. In 3-month-old sheep (n = 8) a piece of vein was harvested to culture autologous endothelial cells. A porcine acellular matrix was reendothelialized and implanted in juvenile sheep as pulmonary interposition. The valves were explanted after 1 week, 3 and 6 months. Examination was performed by X-ray, light microscopy, and atomic absorption spectrometry. Reendothelialization mean rate was 10.3 x 10(5) cells/cm(2) with a mean endothelial cell viability of 95.5% (0.98 x 10(5) cells/cm(2)). X-ray examination showed no cusp calcification at 1 week, 3 and 6 months, which was confirmed by light microscopy. Immunostaining for factor VIII demonstrated colonization of viable mature autologous endothelial cells on the heart valve after the seeding process. The atomic absorption spectrometry showed no significant increase of the calcium content after 3 (P value >.1) and 6 months (P value >.1) compared with nonimplanted tissue engineered heart valves. The tissue engineered valve showed no cusp calcification in the juvenile sheep after 3 and 6 months.

Animals↗

Osteoblast response to PLGA tissue engineering scaffolds with PEO modified surface chemistries and demonstration of patterned cell response.

Because tissues are characterized by a well-defined three-dimensional arrangement of cells, tissue engineering scaffolds that facilitate the organization and differentiation of new tissue will have improved performance in comparison to scaffolds that only provide surfaces for cell attachment and growth. We hypothesize that instructions for cells can be incorporated into tissue engineering scaffolds by patterning the scaffold's architecture and surface chemistry. Our goals for the presented work were to collect data about cell response to three-dimensional, porous scaffolds with uniformly modified surfaces chemistries, and to demonstrate patterning of cell response by patterning surface chemistry. Our system was osteoblast response to poly(l-lactide-co-glycolide) scaffolds modified with poly(ethylene oxide) (PEO). Scaffolds were fabricated using the Three-Dimensional Printing (3DP) process which has control over scaffolds properties to a resolution of approximately 100 microm in all three dimensions. At higher PEO concentrations, adhesion, growth rates, and migration of rat osteoblasts were reduced; alkaline phosphate activity was increased, and cells were less spread and had microvilli. Patterned regions of low and high cell adhesion were demonstrated on scaffolds fabricated with 1 mm thick stripes of PEO and non-PEO regions.

Animals↗

[Primary research of repairing large articular cartilage defect by tissue-engineering cartilage in rabbits].

OBJECTIVE: To investigate the feasibility of repairing the whole layer defects of tibial plateau by implanting tissue-engineering cartilage. METHODS: The chondrocytes of 2-week-old rabbits were cultured and transferred to the 3rd generation, and mixed with human placenta collagen-sponge. The whole layer defects of tibial plateau in adult rabbits were repaired by the tissue-engineering cartilage in the experimental group; the defects were left un-repaired in control group. The repair results of defects were observed after 4, 12 and 24 weeks. RESULTS: In experimental group, no obvious new cartilage formation was seen 4 weeks after operation; some new cartilage formation was found after 12 weeks. Histological observation showed that chondrocytes had irregular edge, honeycombing structure and that cartilage cavities formed around the chondrocytes. After 24 weeks, obvious new cartilage formation was found with smooth surface, and linked with the tissues around it, but the defect was not repaired completely; histological results showed that cartilage cavities formed and that cartilage matrix was stained positively for toluidine blue. In control group, the defect was not repaired. CONCLUSION: The tissue-engineering cartilage can repair the defects of the whole layer cartilage of tibial plateau in rabbits, it is feasible to repair the whole layer cartilage defects of tibial plateau by this method.

Animals↗

Mechanical properties and compositions of tissue engineered and native arteries.

With the goal of mimicking the mechanical properties of a given native tissue, tissue engineers seek to culture replacement tissues with compositions similar to those of native tissues. In this report, differences between the mechanical properties of engineered arteries and native arteries were correlated with differences in tissue composition. Engineered arteries failed to match the strengths or compliances of native tissues. Lower strengths of engineered arteries resulted partially from inferior organization of collagen, but not from differences in collagen density. Furthermore, ultimate strengths of engineered vessels were significantly reduced by the presence of residual polyglycolic acid polymer fragments, which caused stress concentrations in the vessel wall. Lower compliances of engineered vessels resulted from minimal smooth muscle cell contractility and a lack of organized extracellular elastin. Organization of elastin and collagen in engineered arteries may have been partially hindered by high concentrations of sulfated glycosaminoglycans. Tissue engineers should continue to regulate cell phenotype and promote synthesis of proteins that are known to dominate the mechanical properties of the associated native tissue. However, we should also be aware of the potential negative impacts of polymer fragments and glycosaminoglycans on the mechanical properties of engineered tissues.

Animals↗

Long-term intermittent compressive stimulation improves the composition and mechanical properties of tissue-engineered cartilage.

Tissue engineering of articular cartilage is a promising alternative for cartilage repair. However, it has been difficult to develop tissue in vitro that mimicks native cartilage. Cartilaginous tissue formed in vitro does not accumulate enough extracellular matrix, is deficient in collagen, and possesses only a fraction of the mechanical properties of native cartilage. In this study, we investigated whether long-term intermittent compressive stimulation would improve the quality of the generated tissue. Chondrocyte cultures were established on the surface of porous calcium polyphosphate substrates and allowed to form cartilaginous tissue. In vitro-formed tissues were subjected to different stimulation protocols for 1 week. The optimal mechanical stimulation parameters identified in this short-term study were then applied to the cultures for up to 4 weeks. Mechanical stimulation applied at a 5% compressive amplitude at a frequency of 1 Hz for 400 cycles every second day resulted in the greatest increase in collagen synthesis (37 +/- 9% over control) while not significantly affecting proteoglycan synthesis (2 +/- 8% over control). This condition, applied to the chondrocyte cultures for 4 weeks, resulted in a significant increase in the amount of tissue that formed (stimulated, 2.4 +/- 0.2 mg dry wt; unstimulated, 1.61 +/- 0.08 mg dry wt). Stimulated tissues contained approximately 40% more collagen (stimulated, 590 +/- 58 microg; unstimulated, 420 +/- 42 microg), and 30% more proteoglycans (stimulated, 393 +/- 34 microg; unstimulated, 302 +/- 32 microg) as well as displaying a 2- to 3-fold increase in compressive mechanical properties (maximal equilibrium stress: stimulated, 10 +/- 1 kPa; unstimulated, 5 +/- 1 kPa; maximal equilibrium modulus: stimulated, 80 +/- 23 kPa; unstimulated, 24 +/- 6 kPa). The results of this study demonstrate that intermittent mechanical stimulation can increase collagen synthesis and, when applied over a 4-week period, can accelerate extracellular matrix accumulation as well as improve the material properties of the developed tissue. Interestingly, only short periods of mechanical stimulation (6 min every second day) were needed to affect the quality of cartilaginous tissue formed in vitro.

Adaptation, Physiological↗