PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROPHORESIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Plastic microchip electrophoresis for genetic screening: the analysis of polymerase chain reactions products of fragile X (CGG)n alleles.

Clinical screening of abnormal chromosomes associated with fragile X syndrome (FXS) demands a high-throughput method including DNA sizing and detection of the amplified products. This study is to explore the use of polymer microchip electrophoresis for the analysis of polymerase chain reaction (PCR) products of fragile X (CGG)n alleles to facilitate a fast exclusion test of FXS. The sequences flanking the CGG-repeat of FMR1 gene was amplified by betaine-PCR and the amplified products were desalted and then analyzed by microchips which were fabricated on poly(methyl methacrylate) (PMMA) substrate. The PCR bands with more than six CGG-repeats in difference could be clearly distinguished in less than 3 min by microchip electrophoresis with a separation length of 6 cm. It was found that the signal was greatly enhanced with the use of both covalent (Cy5) and intercalating dye (TORRO-3), which has never been demonstrated before. We tested the method by reanalysis of twelve samples from males and six samples from females. For female samples with less than six repeat differences, Southern blotting method was performed to confirm or exclude the findings from microchips. It was found that the test results from all male and female samples show a 100% correlation between the microchip electrophoresis and the existing methods.

Electrophoresis, Capillary↗

High speed single nucleotide polymorphism typing of a hereditary haemochromatosis mutation with capillary array electrophoresis microplates.

A single nucleotide polymorphism (SNP) typing assay is developed and evaluated on a microfabricated capillary array electrophoresis system. Using fluorescently labeled allele-specific primers, the S65C (193A-->T) substitution associated with hereditary haemochromatosis in the HFE gene is genotyped. The covalently labeled polymerase chain reaction (PCR) products are separated on a microfabricated radial capillary array electrophoresis microplate using nondenaturing gel media in under two minutes. Detection is accomplished with a laser-excited rotary confocal scanner. The Rox-labeled A-allele specific amplicon (211 bp) is differentiated from the R110-labeled T-allele specific amplicon (201 bp) by both size and color. This study demonstrates the feasibility of using allele-specific PCR with covalently labeled primers for high speed fluorescent SNP typing on microfabricated radial capillary array electrophoresis microplates.

Alleles↗

Determination of nucleosides in natural Cordyceps sinensis and cultured Cordyceps mycelia by capillary electrophoresis.

Cordyceps sinensis is a well-known traditional Chinese medicine, and some of the active components are nucleosides. The analysis of nucleosides in Cordyceps material has been performed by reversed-phase high-performance liquid chromatography (HPLC) with gradient elution or by spectrometry. Here, we have explored the possibility of using capillary electrophoresis to determine the content of three major nucleosides (adenosine, guanosine and uridine) in Cordyceps. Capillary electrophoresis needs no gradients, and it provides a better separation due to its higher efficiency. In order to optimize the resolution, the separation of adenosine, guanosine and uridine was determined in Cordyceps with respect to the variation of buffer concentration, pH, temperature, and voltage. By using the calibrated electrophoresis system, the separation was achieved for the three nucleosides in less than 10 min with a background electrolyte consisting of 0.2 M boric acid-sodium hydroxide buffer, pH 8.5. The nucleoside contents of various types of natural Cordyceps and cultured Cordyceps mycelia were determined and compared. There was a great variation of nucleoside content in different sources of Cordyceps; the cultured Cordyceps mycelia, however, contains a much higher concentration than the natural Cordyceps.

Adenosine↗

An approach to the sensitivity of temperature-gradient gel electrophoresis in the detection of clonally expanded T-cells in cutaneous T-cell lymphoma.

Detection of T-cell clonality by polymerase chain reaction (PCR) and high-resolution electrophoresis facilitates differentiation of early stages of cutaneous T-cell lymphoma (CTCL) from benign T-cell-rich dermatoses. However, data regarding the sensitivity of the various electrophoresis techniques differ remarkably. In the present study, the capacity of heteroduplex (HD)-loaded temperature-gradient gel electrophoresis (TGGE) to detect clonally expanded T-cells was assessed systematically and modifications to the procedure were defined. Using our standard protocol, HD-TGGE detected clonal T-cell receptor (TCR)-gamma PCR products, generated from the Jurkat cell line, down to a total of 2 ng/microL (14 ng) DNA. However, slowly migrating single strands of the clonal PCR product reduced the amount of the clonality indicating homoduplices. To overcome this single-strand formation, thus decreasing the detection limit, the urea concentration in the gel and the temperature ramp for the HD-formation were altered, as well as the temperature gradient in the gel. Application of the modified protocol resulted in a tenfold lower detection limit of 0.15 ng/microL (1.05 ng) DNA in the clonal band. The sensitivity of the adapted HD-TGGE was investigated by dilution experiments using the well established T-cell lines Jurkat, Molt-4, MyLa and SeAx. By these approaches clonal PCR products diluted in nonclonal PCR products were detectable down to concentrations of 5-10%. Comparably, in the case of mixtures of clonal in nonclonal DNA the detection limit reached 5-10% clonal DNA. However, by dilution of clonal cells in nonclonal peripheral blood mononuclear cells, which corresponds to in vivo conditions, a lower detection limit of approximately 1-5% was observed.

DNA, Neoplasm↗

Analysis of oligonucleotides and unincorporated nucleotides from in vitro transcription by capillary electrophoresis in Pluronic F127 gels.

Small functional RNAs required for structure studies are often prepared by in vitro transcription. Capillary electrophoresis in liquid crystalline gels of Pluronic F127 was used to analyze unfractionated in vitro transcription reactions and anion-exchange high-performance liquid chromatography (HPLC) fractions from transcription reactions. Guanosine monophosphate (GMP), the four nucleoside triphosphates (NTPs), abortive transcripts, and transcripts with lengths near the desired product length were simultaneously resolved and quantified in a single run. Oligonucleotides up to at least 35 nucleotides were resolved to baseline within 10 min using a moderate field (185 V/cm) and short effective capillary length (7.6 cm) for electrophoresis in 20% Pluronic F127 at pH 8.3 in Tris-borate-EDTA (TBE) buffer (30 degrees C). Nucleotide migration times were 4-5 min, in the order UTP+CTP (unresolved) <ATP<GTP<GMP. A single capillary filling was reused for 40-50 runs with little decrease in performance, and for up to 100 runs with performance acceptable for many applications. Higher electric fields appeared to affect the gel structure and necessitated more frequent capillary refilling. Capillary gel electrophoresis (CGE) of HPLC fractions in Pluronic gels facilitates rapid recovery of RNA products and the large remaining amounts of valuable, isotopically labeled NTPs. In addition, comparison of electrophoretic patterns under denaturing and nondenaturing conditions yields insights into potential conformational heterogeneity of the folded nucleic acid states. CGE in Pluronic gels provides a rapid, highly discriminating means for analyzing in vitro transcription reactions.

Cell-Free System↗

Diffusion coefficient of DNA molecules during free solution electrophoresis.

The free-draining properties of DNA normally make it impossible to separate nucleic acids by free-flow electrophoresis. However, little is known, either theoretically or experimentally, about the diffusion coefficient of DNA molecules during free-flow electrophoresis. In fact, many authors simply assume that the Nernst-Einstein relation between the mobility and the diffusion coefficient still holds under such conditions. In this paper, we present an experimental study of the diffusion coefficient of both ssDNA and dsDNA molecules during free-flow electrophoresis. Our results unequivocally show that a simplistic use of Nernst-Einstein's relation fails, and that the electric field actually has no effect on the thermal diffusion process. Finally, we compare the dependence of the diffusion coefficient upon DNA molecular size to results obtained previously by other groups and to Zimm's theory.

Algorithms↗

Prevention of evaporation of small-volume sample solutions for capillary electrophoresis using a mineral-oil overlay.

The suppression of evaporation of water from small volumes of sample solutions or reagents for capillary electrophoresis by the use of a mineral-oil overlay was investigated in affinophoresis applications, in which the affinity constant of a mutant protein of recombinant human galectin-1 to a lactose affinophore, a triply negative charged ion having a lactoside as an affinity ligand, was determined. When an injection was carried out from a minimum of 20 microL of an aqueous solution beneath the oil overlay, no oil contamination inside the capillary was observed, provided the capillary was cleanly cut so that the end was flat, and the polyimide coating had been removed for a distance of about 2 mm from the end. Affinophoresis was carried out using 20 microL of an affinophore solution covered with an oil overlay. The abnormalities in the electropherograms as the result of the evaporation of the water from the solution during storage prior to use in an automatic operation of a capillary electrophoresis instrument were suppressed, with respect to the formation of a base line gap, an increase in the detection time of a marker ion and an increase in the initial current. A solution in a vial could be used repeatedly for a longer period of time when overlaid with mineral oil than in the absence of an overlay. The use of a mineral-oil overlay is a simple but very efficient technique for solving the problem of the evaporation of water from small volumes of aqueous solutions for use in capillary electrophoresis.

Electrophoresis, Capillary↗

Capillary sodium dodecyl sulfate-DALT electrophoresis of proteins in a single human cancer cell.

Capillary Sodium dodlecyl sulfate (SDS)-DALT an (abbreviation for Dalton) electrophoresis was applied to analysis of proteins in single HT29 human colon adenocarcinoma cells. A vacuum pulse was employed to introduce a single cell into the coated capillary. Once the cell was lysed, proteins were denatured with SDS, fluorescantly labeled with 3-(2-furoyl)-quinoline-2-carboxaldehyde (FQ), and then separated by using 8% pullulan as the sieving matrix. This method offers a few advantages for single-cell protein analysis. First, it provides reproducible separation of single-cell proteins according to their size. Based on comparison with the migration time of standard proteins, most components from a single HT29 cancer cell have molecular masses within the range of 10-100 kDa. Second, as a one-dimensional separation method, it gives fairly good resolution for proteins. Typically, around 30 protein components of a single HT29 cell were resolved, indicating that this method has similar peak capacity to SDS-polyacrylamide gel electrophoresis (PAGE). Third, this method shows high detection sensitivity and wide dynamic range, which is important because of the wide range of protein expression in living systems. Detection limits for standard proteins ranged from 10(-10) to 10(-11) M. Finally, this method provides much higher speed than classical gel electrophoresis methods, and it provides automated anlysis of cellular proteins at the single-cell level; the separation is complete in 30 min and the entire analysis takes approximately 45 min.

Adenocarcinoma↗

Rapid sizing of microsatellite alleles by gel electrophoresis on microfabricated channels: application to the D19S394 tetranucleotide repeat for cosegregation study of familial hypercholesterolemia.

This study evaluated the applicability of microchip electrophoresis to the sizing of microsatellites suitable to genetic, clinical and forensic applications. The evaluation was performed with the D19S394 tetranucleotide (AAAG) repeat characterized by a wide variation in the repeat number (1-17) and a short recombination distance from the low-density lipoprotein (LDL)-receptor gene that makes it suitable to cosegregation analysis of familial hypercholesterolemia (FH). The study was performed with 70 carriers of two LDL-receptor mutations common in northern Italy (i.e., the 4 bp insertion in exon 10 known as FH-Savona and the D200G missense mutation in the exon 4, known as FH-Padova 1) and 100 healthy controls. The polymerase chain reaction (PCR) amplification products prepared with a cosolvent PCR protocol and an antibody-protected polymerase were directly analyzed with an apparatus for high-voltage capillary electrophoresis on microchips and laser-induced fluorescence detection equipped with chips for the analysis of 25-500 bp dsDNA fragments. The test could not be extended to dinucleotide repeats due to the resolution characteristics of the available microchip. This novel approach was able to distinguish 17 microsatellite alleles varying from 0 to 17 repeats. Many of these alleles were quite rare, but the seven more abundant accounted for over the 70% of allele distribution in control population. The standard deviation in the sizing of the most abundant alleles ranged from +0.60 to +/- 0.75 bp. This indicated that the size attribution to a conventional allele using the +/- 1 bp range around it allowed a confidence limit above the 80 %. The sizing of D19S394 obtained this way allowed the cosegregation analysis with both the FH mutations tested. Therefore, this innovative approach to microsatellite sizing was much simpler, but equally effective as traditional capillary electrophoresis, at least with tetranucleotide repeats.

Alleles↗

The use of light scattering for precise characterization of polymers for DNA sequencing by capillary electrophoresis.

The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer-solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water-soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi-angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on-line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.

Electrophoresis, Capillary↗

Maize pollen enzymes after two-dimensional polyacrylamide gel electrophoresis in the presence or absence of sodium dodecyl sulfate.

Twelve enzymes from mature pollen grains of maize were separated by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). The separation in the second dimension was both in the presence and absence of sodium dodecyl sulfate (SDS). Ten of the investigated enzymes lost activity after separation in the presence of SDS, but those of esterases and acid phosphatase could be recovered. On the other hand, 2-D electrophoresis without SDS is suitable for the analysis of maize pollen pectinesterase, malate dehydrogenase, glutamic-oxalacetic transaminase, diaphorase, superoxide dismutase, and phosphoglucose isomerase. 1-D PAGE and isoelectric focusing (IEF) are sufficient to analyze glucose-6-phosphate dehydrogenase, alcohol dehydrogenase, shikimic dehydrogenase, and glutamate dehydrogenase. The possibility of applying 2-D electrophoresis for the analysis of enzymes from single stigma and stigma exudate is dicussed.

Electrophoresis, Gel, Two-Dimensional↗

Biochemical dissection of the mitochondrial proteome from Arabidopsis thaliana by three-dimensional gel electrophoresis.

We report a subdivision of the mitochondrial proteome into defined sets of proteins, which is based on the combination of three different gel electrophoresis procedures. First, Blue-native polyacrylamide gel electrophoresis is employed to separate mitochondrial protein complexes. The protein complexes are electroeluted and completely detached from Coomasssie blue. Subsequently the subunits of the protein complexes are separated by isoelectric focusing and finally by sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis. The resolution capacity of the procedure is demonstrated for the ATP synthase complex, the cytochrome c reductase complex and the preprotein translocase of the outer mitochondrial membrane (the TOM complex). The method allows the separation of isoforms of subunits forming part of protein complexes, whose occurrence seems to be rather a rule than an exception in higher eukaryotes. Furthermore, extremely hydrophobic proteins are detectable on the gels.

Adenosine Triphosphatases↗

Determination of oxalate in urine by zone electrophoresis on a chip with conductivity detection.

The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel coupled to a 500 nL sample injection channel) and a pair of on-chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in urine was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (4.0) provided an adequate selectivity in the separation of oxalate from anionic urine constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 8 x 10(-8) mol/L concentration also in samples containing chloride (a major anionic constituent of urine) at 3.5 x 10(-3) mol/L concentrations. Such a favorable analyte/matrix concentration ratio (in part, attributable to a transient isotachophoresis stacking in the initial phase of the separation) made possible accurate and reproducible (typically, 2-5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample) determination of oxalate in 500 nL volumes of 20-100-fold diluted urine samples. Short analysis times (about 280 s), no sample pretreatment (not considering urine dilution) and reproducible migration times of this analyte (0.5-1.0% RSD values) were characteristic for ZE on the chip. This work indicates general potentialities of the present chip design in rapid ZE analysis of samples containing the analyte(s) at high ionic matrix/analyte concentration ratios.

Electric Conductivity↗

Capillary electrophoresis investigation of a partially unfolded conformation of beta(2)-microglobulin.

Dialysis-related amyloidosis is a disease in which partial unfolding of beta(2)-microglobulin plays a key pathogenetic role in the formation of the amyloid fibrils. We have recently demonstrated that a partially unfolded conformer of beta(2)-microglobulin is involved in fibrillogenesis and that this species is significantly populated under physiological conditions. In this work capillary electrophoresis has been used to measure the equilibrium between the native protein and this conformer in samples known to have a higher or lower amyloidogenic potential, namely full-length beta(2)-microglobulin, two truncated species and a mutant, created by replacing histidine in position 31 with thyrosine. In addition, for all protein species folding stability experiments have been carried out by monitoring the secondary structure by circular dichroism at increasing concentrations of guanidinium chloride. The values of free energy of unfolding in the absence of denaturant, obtained by elaboration of these experiments, were found to be inversely correlated to the area percent of the partially unfolded conformer, as measured by capillary electrophoresis. Affinity capillary electrophoresis experiments have been also carried out under nondenaturing conditions to assess the affinity of copper and suramin to either the native form or the conformational intermediate of full-length beta(2)-microglobulin.

Amino Acid Sequence↗

Mapping of stereoselective recognition sites on human serum transferrin by capillary electrophoresis and molecular modelling.

Stereoselective recognition of chiral compounds can be used for mapping of surface interaction sites on proteins. Iron-free human serum transferrin is a suitable chiral selector in capillary electrophoresis used in native form in solution. Separation of optical isomers of tryptophan-methylester, tryptophan-ethylester and tryptophan-butylester and various drugs were studied in capillary zone electrophoresis applying a distinct transferrin zone prior to sample injection. Changes in the electrophoretic patterns (i.e., in the migration properties) of the molecules reflected the possible interactions with the protein. The tryptophan derivatives and eight drugs possessed stereoselective interactions, seven drugs showed interactions without appreciable chiral separation, and the others did not present any direct complexation with the protein molecules. Molecular modelling was performed to characterize the binding areas at the iron binding site of iron-free transferrin. The docking of tryptophan derivatives on transferrin showed that the R-enantiomers possess a stronger complexation with transferrin, whereas the S-enantiomers are bound by weaker interactions, which is in excellent agreement with the capillary electrophoresis results, where the R-enantiomers were always retarded stronger by transferrin. A ranking of drugs by the lipo score parameter of the docking shows an accordance with the stereoselective interactions by the protein.

Binding Sites↗

Recent progress in DNA analysis by capillary electrophoresis.

A number of recent developments in DNA analysis by capillary electrophoresis are here reviewed. They include capillary arrays for fast, parallel DNA sequencing as well as microfabricated capillary arrays. Microfluidic chips for DNA sizing and quantitation are also covered, as well as microdevices containing arrays of regular obstacles acting as size-separators during DNA migration. Screening of DNA point mutations by two much improved techniques is also reported: in one case, such mutations are detected (but only on relative short, ca. 60-70 base-long fragments) by free electrophoresis in rather acidic (pH ca. 3) buffers; in the case of single-strand chain polymorphism, an improved technique is described based on near-neutral pH buffers with mixtures of Tris/MES cations/zwitterions. When studying the behavior of inorganic and organic cations in the Debye-Hückel layer of DNA, it was found that the latter (especially a large number of Good's buffers and other zwitterions, such as His) would bind to the DNA filament not only via charge interaction, but also via additional bonds, notably hydrogen bonds, thus altering the electrophoretic (and possibly the biological) behavior of DNA molecules. However, whether or not borate ions would bind to DNA remains still an unsettled question. Finally, capillary electrophoresis was found to be instrumental in measuring fine physicochemical parameters pertaining to DNA polyelectrolytes, such as their free mobility and their translational diffusion coefficients.

Animals↗

Poly-N-hydroxyethylacrylamide (polyDuramide): a novel, hydrophilic, self-coating polymer matrix for DNA sequencing by capillary electrophoresis.

A replaceable polymer matrix, based on the novel monomer N-hydroxyethylacrylamide (HEA), has been synthesized for application in DNA separation by microchannel electrophoresis. The monomer was found by micellar electrokinetic chromatography analysis of monomer partitioning between water and 1-octanol to be more hydrophilic than acrylamide and N,N-dimethylacrylamide. Polymers were synthesized by free radical polymerization in aqueous solution. The weight-average molar mass of purified polymer was characterized by tandem gel permeation chromatography-multiangle laser light scattering. The steady-shear rheological behavior of the novel DNA sequencing matrix was also characterized, and it was found that the viscosity of the novel matrix decreases by more than 2 orders of magnitude as the shear rate is increased from 0.1 to 1000 s(-1). Moreover, in the shear-thinning region, the rate of change of matrix viscosity with shear rate increases with increasing polymer concentration. Poly-N-hydroxyethylacrylamide (PHEA) exhibits good capillary-coating ability, via adsorption from aqueous solution, efficiently suppressing electroosmotic flow (EOF) in a manner comparable to that of poly-N,N-dimethylacrylamide. Under DNA sequencing conditions, adsorptive PHEA coatings proved to be stable and to maintain negligible EOF for over 600 h of electrophoresis. Resolution of DNA sequencing fragments, particularly fragments > 500 bases, in PHEA matrices generally improves with increasing polymer concentration and decreasing electric field strength. When PHEA is used both as a separation matrix and as a dynamic coating in bare silica capillaries, the matrix can resolve over 620 bases of contiguous DNA sequence within 3 h. These results demonstrate the good potential of PHEA matrices for high-throughput DNA analysis by microchannel electrophoresis.

Acrylamides↗

Analysis of DNA polymorphisms on the human Y-chromosome by microchip electrophoresis.

Validation of microchip electrophoresis in DNA analysis has been carried out using an Agilent 2100 Bioanalyzer. With a DNA 500 Assay Kit, the reproducibility and accuracy of fragment sizing of a 10 bp DNA ladder have been shown to be satisfactory with the relative standard deviation and the relative error mostly below 1.0 and 5.0% (n = 12), respectively. Both intraday and interday validations of fragment sizing and quantitation have also been performed with a 7500 Assay Kit (n = 48). Although the results of quantitation are not as good as that of sizing, due to the manual introduction of samples and markers into the chip wells, they are still sufficient to carry out further analyses of practical samples. Based on such reliable results, fast analysis of DNA polymorphisms on the human Y-chromosome has been realized with microchip electrophoresis. The total analysis times of three genomic polymorphisms on the Y-chromosome, Y Alu polymorphism, 47z/StuI, and 12f2, are all within 100 s, and the relative standard deviation and relative error of fragment sizes are below 3.5 and 3.7%, respectively. In addition, a mixture of nine DNA markers on the human Y-chromosome related to examine the cause of spermatogenic failure have been separated successfully with the smallest fragment size difference of 7 bp. Our results demonstrate the potential of microchip electrophoresis in polymorphism analysis with the advantages of high speed, good reproducibility, high precision, and high resolution.

Chromosomes, Human, Y↗