Biocompatibility of alginates for grafting: impact of alginate molecular weight.

Optimising microencapsulation technology towards the effective clinical transplantation has created the need for highly biocompatible alginates. Therefore, in this study the biocompatibility of different beads prepared from alginates with varying average molecular weight was examined. In some experiments the beads were covered with a multilayer membrane surrounded by an alginate layer. First of all, we found that beads made of a lower weight average alginate elicted a much stronger fibrotic response compared to beads made of a higher weight average alginate (LV-alginate > MV-alginate). The results were confirmed by the observation that the extent of tissue fibrosis was significantly increased in multilayer capsules made of an alginate with a lower weight average (core and surface LV-alginate, Mw 0.7-1 * 10(6) g/mol, viscosity of a 0.1% solution 1-2.5 mPa s(-1)) compared to multilayer capsules made of an alginate with a higher weight average (core and surface MV-alginate; Mw 1.2-1.3 * 10(6) g/mol, viscosity of a 0.1% solution 5-7 mPa s(-1)). It should be stressed, that the pro-fibrotic effect of the LV-alginate alginate in the core was only partially reversed by a MV-alginate on the surface of the multilayer capsules. On the basis of the raised data, it can be assumed that the molecular weight average of the alginates have an decisive effect on the biocompatibility. Therefore, it seems to be recommendable to reduce the low molecular weight fractions of the alginate during the purification process to improve the biocompatibility.

Alginates↗

Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study.

BACKGROUND: In chronic ambulatory peritoneal dialysis, bicarbonate-buffered fluids, with their neutral pH and less advanced glycosylation end-products (AGE) and glucose degradation products (GDP), have better biocompatibility than conventional peritoneal dialysis (PD) solutions. That difference may be more beneficial in automated peritoneal dialysis (APD), due to its more frequent exchanges and longer contact times with fresh dialysate. We performed a prospective, randomized study in APD patients to compare the biocompatibility of conventional and bicarbonate/lactate-buffered PD fluids. METHODS: We randomized 14 APD patients to have APD with either conventional or bicarbonate/lactate-based fluids. After 6 months, both groups changed to the other solution. The overall observation period was 12 months. After 1 and 5 months and again after 7 and 11 months, phagocytotic and respiratory burst capacities of effluent peritoneal macrophages were determined. Plasma interleukin (IL)-6 and C-reactive protein (CRP) as well as effluent IL-6, CRP, transforming growth factor (TGF)-beta 1, AGE and CA125 concentrations were measured. Inflow pain was quantified using a patient questionnaire. RESULTS: Respiratory burst capacity remained unchanged and phagocytotic activity increased significantly during APD (P<0.001) with the bicarbonate/lactate fluid. Effluent IL-6 release was significantly lower than with the lactate fluid (P<0.05). While in the effluent TGF-beta 1 was unaffected, AGE concentration was lower after bicarbonate/lactate treatment (P<0.05). Effluent CA125 concentration, an indicator of mesothelial cell integrity, was higher (P<0.05) in neutral effluents. Finally, patients' inflow pain diminished (P = 0.05) when using the neutral fluid. CONCLUSIONS: The use of a neutral PD fluid in APD improved patients' inflow pain as well as biocompatibility parameters reflecting enhanced phagocytotic activity of peritoneal macrophages, reduced constitutive inflammatory stimulation (IL-6), reduced AGE accumulation in the peritoneal cavity and better preservation of the mesothelial cell integrity. From the biocompatibility point of view, a neutral fluid with low GDP content can be recommended as the primary choice for APD.

Adult↗

Addition of cytochalasin D to a biocompatible oil stent coating inhibits intimal hyperplasia in a porcine coronary model.

BACKGROUND: Polymer-based, drug-eluting stents, are currently under extensive investigation in the conquest against in-stent restenosis. Concern remains, however, about potential long-term lack of biocompatibility of the polymers used in these studies. Therefore, this study aimed to evaluate in porcine coronary arteries (1) the in vivo biocompatibility of a new natural, eicosapentaenoic acid oil stent-coating and (2) the efficacy of this coating in preventing in-stent restenosis when cytochalasin D--an inhibitor of actin filament formation, that interferes with cell proliferation and migration--was added. METHODS AND RESULTS: To assess in vivo biocompatibility of the oil coating, 15 bare and 15 oil-coated stents were randomly deployed in coronary arteries of 15 pigs. No difference in tissue response, regarding inflammation or proliferation, was seen between both groups at five days or at four weeks follow-up. To evaluate the efficacy of the coating in preventing in-stent restenosis by adding a potential anti-restenotic drug, stents were dip-coated in 20 mg cytochalasin D/ml oil solution, resulting in 93 +/- 18 microg cytochalasin D/stent load (n = 3). In vitro drug release studies showed sustained release up to four weeks. Next, 11 oil-coated and 11 cytochalasin D-loaded stents were randomly implanted in coronary arteries of 11 pigs. At four weeks, a 39% decrease in neointimal hyperplasia (p < 0.05, ANCOVA, with injury as covariate) was found in cytochalasin D-loaded stents compared to oil-coated stents. CONCLUSIONS: This new natural oil stent-coating shows excellent biocompatibility to vascular tissue. Local cytochalasin D delivery from this stent-platform significantly inhibits neointimal hyperplasia in a porcine coronary model.

Animals↗

Biocompatibility of two novel dermal fillers: histological evaluation of implants of a hyaluronic acid filler and a polyacrylamide filler.

BACKGROUND: Several biomaterials are currently available for soft-tissue augmentation. Biocompatibility is an indispensable condition for any such product. Appropriate histologic evaluation is a prerequisite for understanding the responses of tissues to implant materials. Recently, hyaluronic acid and polyacrylamide gel products have been introduced as dermal fillers. Both types of product are widely considered to be biocompatible. METHODS: The present study compared tissue responses in a rat in vivo model (n = 80) to a hyaluronic acid filler (Restylane Perlane; Q-Med AB, Uppsala, Sweden) and a polyacrylamide gel filler (Aquamid; Contura SA, Montreux, Switzerland). Four groups were evaluated: group 1 (n = 20) received the Restylane Perlane implant, group 2 received the Aquamid implant (n = 20), group 3 comprised a placebo group (n = 20), group 4 was the control group (n = 20). Responses and biocompatibility were assessed by histopathologic and histomorphometric evaluations between 1 week and 8 months after implantation. RESULTS: The two products induced very different tissue responses. The polyacrylamide gel filler was highly bioactive, undergoing cell infiltration and integration into tissues. The hyaluronic acid filler underwent minimal cell infiltration, and the product remained surrounded by a uniformly thin capsule. CONCLUSIONS: This study reveals that two soft-tissue fillers considered to be biocompatible induce very different tissue reactions. This indicates that their behavior in clinical practice is likely to be different.

Acrylic Resins↗

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.

Insertable microelectrode arrays can be used to activate neurons or to sense neural signals for use in prosthetics. The relationship of the microelectrodes to the neurons is determined by random alignment and by biocompatibility. Issues that determine the biocompatibility of insertable microelectrode arrays were investigated. Arrays were implanted into the cortex of rabbit brain and fixed to the skull. Following six-month survival, neuron density as a function of distance from the shafts of the arrays was measured to assess destruction of neurons. Results from a limited number of tests indicated that there was minimal tissue response along the sides of the shafts when shafts were well sharpened, had sufficiently small tip angles, and were clean. Tissue was usually more reactive at the tips of the shafts. It was concluded that silicon microshafts of appropriate shaft and tip design were biocompatible along the sides of the shaft, but that relatively severe reactions could be anticipated at the tips. Recording or stimulation sites should be located away from the tips on the sides of the shafts for better coupling with individual neurons. Measurement of neuron density as a function of distance from the shafts was a sensitive and quantitative technique for assessing biocompatibility. Additional measures such as glial density as a function of distance from the shafts, and incidence of microhematoma formation were proposed.

Animals↗

The chemical constitution and biocompatibility of accelerated Portland cement for endodontic use.

AIM: To evaluate the biocompatibility of mineral trioxide aggregate and accelerated Portland cement and their eluants by assessing cell metabolic function and proliferation. METHODOLOGY: The chemical constitution of grey and white Portland cement, grey and white mineral trioxide aggregate (MTA) and accelerated Portland cement produced by excluding gypsum from the manufacturing process (Aalborg White) was determined using both energy dispersive analysis with X-ray and X-ray diffraction analysis. Biocompatibility of the materials was assessed using a direct test method where cell proliferation was measured quantitatively using Alamar Blue dye and an indirect test method where cells were grown on material elutions and cell proliferation was assessed using methyltetrazolium assay as recommended by the International standard guidelines, ISO 10993-Part 5 for in vitro testing. RESULTS: The chemical constitution of all the materials tested was similar. Indirect studies of the eluants showed an increase in cell activity after 24 h compared with the control in culture medium (P<0.05). Direct cell contact with the cements resulted in a fall in cell viability for all time points studied (P<0.001). CONCLUSIONS: Biocompatibility testing of the cement eluants showed the presence of no toxic leachables from the grey or white MTA, and that the addition of bismuth oxide to the accelerated Portland cement did not interfere with biocompatibility. The new accelerated Portland cement showed similar results. Cell growth was poor when seeded in direct contact with the test cements. However, the elution made up of calcium hydroxide produced during the hydration reaction was shown to induce cell proliferation.

Aluminum Compounds↗

Dilemma of membrane biocompatibility and reuse.

Numerous articles have been published on the multiple use of dialyzers and on the effect of different reprocessing chemicals and techniques on the dialyzer biocompatibility and performance. The results often appear contradictory, especially those comparing standard biocompatibility parameters. Despite this confusion, a discerning review of the published works allows certain limited conclusions to be drawn. Reprocessing of used hemodialyzers changes the biocompatibility profile of a dialyzer as defined by the parameters complement activation, leukopenia, and cytokine release. The effect of reprocessing depends on the chemicals and reprocessing technique applied and also on the type of membrane polymer being subjected to the reprocessing procedure. Reports of pyrogenic reactions indicate that the flux of the membrane also influences how suitable it is for safe reuse. An increased risk of allergic and pyrogenic reactions appears to be associated with dialyzer reuse. Furthermore, there has been a lack of investigations into the immunologic effect of the layer of adsorbed and chemically altered proteins that remains on the inner surface of reprocessed dialyzers. We conclude that the clinical benefit of dialyzer reuse cannot be generally accepted from a biocompatibility point of view.

Anaphylaxis↗

Does an alteration of dialyzer design and geometry affect biocompatibility parameters?

The aim of the study was to assess the biocompatibility profile of a newly developed high-flux polysulfone dialyzer type (FX-class dialyzer). The new class of dialyzers incorporates a number of novel design features (including a new membrane) that have been developed specifically in order to enhance the removal of small- and middle-size molecules. The new FX dialyzer series was compared with the classical routinely used high-flux polysulfone F series of dialyzers. In an open prospective, randomized, crossover clinical study, concentrations of the C5a complement component, and leukocyte count in blood and various thrombogenicity parameters were evaluated before, and at 15 and 60 min of hemodialysis at both dialyzer inlet and outlet in 9 long-term hemodialysis patients using the FX60S dialyzers and, after crossover, the classical F60S, while in another 9 patients, the evaluation was made with the dialyzers used in reverse order. The comparison of dialyzers based on evaluation of the group including all procedures with the FX60S and the group including procedures with the F60S did not reveal significant differences in platelet count, activated partial thromboplastin times, plasma heparin levels, platelet factor-4, D-dimer, C5a, and leukocyte count at any point of the collecting period. Both dialyzer types showed a significant increase in the plasma levels of the thrombin-antithrombin III complexes; however, the measured levels were only slightly elevated compared with the upper end of the normal range. Biocompatibility parameters reflecting the behavior of platelets, fibrinolysis, complement activation, and leukopenia do not differ during dialysis with either the FX60S or the F60S despite their large differences in design and geometry features. Although coagulation activation, as evaluated by one of the parameters used, was slightly higher with the FX60S, it was still within the range seen with other highly biocompatible dialyzers and therefore is not indicative of any appreciable activation of the coagulation system. Thus, the incorporation of various performance-enhancing design features into the new FX class of dialyzers does not result in a deterioration of their biocompatibility profile, which is comparable to that of the classical F series of dialyzers.

Aged↗

Biocompatibility of hemodialysis membranes: interrelations between plasma complement and cytokine levels.

Hemodialysis (HD) membrane biocompatibility is defined as absence of complement activation. We have recently shown that circulating levels of interleukin (IL) 1 and IL-2 predict death and survival, respectively, of HD patients. Studies have assessed IL-1 in treatments with biocompatible and less biocompatible dialysis membranes, but no study has correlated circulating levels of all these immunoreactants. We assessed these immunoreactants, and temperature as an outcome, during HD in patients treated with different membranes. Twelve stable patients, receiving thrice-weekly chronic bicarbonate HD, were randomly dialyzed with three different types of membranes, composed of: Cuprophan, cuprammonium rayon modified cellulose, and Hemophan. Blood was drawn from the arterial line port before (Pre) and 15, 30, and 60 min during and after (Post) HD. Patients' temperatures were measured before and after each treatment. The plasma concentrations of IL-1 and IL-2 and factors C3a and C5a were assessed by ELISA. There were no differences between baseline levels of any of the immunoreactants in patients treated with different dialyzers. C3a, C5a, and IL-1 levels increased significantly during HD treatments with all three different membranes. C3a, C5a, and IL-1 levels during Cuprophan and Hemophan treatments were significantly higher than the levels during modified cellulose treatment at 30 and 60 min and Post (p < 0.01). For all the immunoreactants, however, the Post levels were higher than the Pre levels. In contrast to IL-1, there were no differences in mean IL-2 levels during treatments when different membranes were compared. There were few correlations of plasma C3a and C5a levels with plasma IL-1 levels, but there was only one treatment time in one dialyzer group during which IL-2 and any of the other factors were correlated. Pre and Post temperature values and percent change in temperature were not correlated with any of the immunoreactants measured. These data show that C3a, C5a, and IL-1 responses are similar, but not identical, during treatments with different membranes. The response of circulating IL-2 levels to treatments is quite different from that of plasma C3a, C5a and IL-1 levels and suggests that these changes are not solely due to treatment factors. Treatment with modified cellulose membranes is associated with a different immunoreactive profile as compared with patients dialyzed using other cellulose membranes. We suggest that circulating IL-1 levels are good biocompatibility markers.

Adult↗

Enhanced biocompatibility for SAOS-2 osteosarcoma cells by surface coating with hydrophobic epoxy resins.

BACKGROUND AND AIMS: Implants for surgical needs are produced from different materials including metals, alloys, ceramics or polymers. Metal implants are preferred in those disciplines where sufficient mechanical strength is needed, including traumatology, orthopedic or dental surgery. Further, modern tissue engineering techniques require scaffold materials to generate shape and stability for in vitro generated transplants. However, the biocompatibility and surface contact of most implants or scaffold materials to vital bone or other tissues are not optimal. Therefore we investigated the biocompatibility of different polymer surfaces to an osteoblastic cell line as a function of wettability or hydrophobicity to describe some of the surface parameters influencing the cell to implant or cell to scaffold contact. METHODS: Glass slides were coated with different polymers and in some cases physically or chemically modified. SAOS-2 osteosarcoma cells were used for the biocompatibility tests on 16 different polymers and modifications thereof. The viability of the adherent cells was investigated by MTT assay. Commercially available tissue culture vessels served as controls. RESULTS: We report that excellent biocompatibility to SAOS-2 osteoblastic cells can be obtained with hydrophobic surfaces generated for instance by epoxy resins. Chemical modification of epoxy resin surfaces yielded even a further increased viability index surpassing the viability index obtained with cell culture vessels. CONCLUSION: We conclude that modified hydrophobic surfaces represent an interesting group of compounds for coating endoprosthetic implants or scaffolds for the purposes of tissue engineering.

Alloys↗

Differential degradation rates in vivo and in vitro of biocompatible poly(lactic acid) and poly(glycolic acid) homo- and co-polymers for a polymeric drug-delivery microchip.

The biocompatibility and biodegradation rate of component materials are critical when designing a drug-delivery device. The degradation products and rate of degradation may play important roles in determining the local cellular response to the implanted material. In this study, we investigated the biocompatibility and relative biodegradation rates of PLA, PGA and two poly(lactic-co-glycolic acid) (PLGA) polymers of 50:50 mol ratio, thin-film component materials of a drug-delivery microchip developed in our laboratory. The in vivo biocompatibility and both in vivo and in vitro degradation of these materials were characterized using several techniques. Total leukocyte concentration measurements showed normal acute and chronic inflammatory responses to the PGA and low-molecular-weight PLGA that resolved by 21 days, while the normal inflammatory responses to the PLA and high-molecular-weight PLGA were resolved but at slower rates up to 21 days. These results were paralleled by thickness measurements of fibrous capsules surrounding the implants, which showed greater maturation of the capsules for the more rapidly degrading materials after 21 days, but less mature capsules of sustained thicknesses for the PLA and high-molecular-weight PLGA up to 49 days. Gel-permeation chromatography of residual polymer samples confirmed classification of the materials as rapidly or slowly degrading. These materials showed thinner fibrous capsules than have been reported for other materials by our laboratory and have suitable biocompatibility and biodegradation rates for an implantable drug-delivery device.

Biocompatible Materials↗

Preparation, in vitro release, in vivo absorption and biocompatibility studies of insulin-loaded microspheres in rabbits.

The purpose of this study was to develop a single-dose insulin delivery system based on poly (lactide-co-glycolide) (PLGA) microspheres to provide basal insulin level for a prolonged period. Insulin-loaded PLGA microspheres were prepared by water-in-oil-in-water double emulsion (batch A) and solid-in-oil-in-water emulsion (batch B) methods. Microspheres were characterized for physical characteristics and in vitro release. In vivo absorption of insulin and biocompatibility of insulin-loaded PLGA microspheres were performed in diabetic New Zealand white rabbits. Light and transmission electron microscopy were performed on the skin tissues excised from microspheres injected sites in order to study the biocompatibility. The burst release of insulin was high (47%) from batch B and low (5%) from batch A. Therefore, we mixed microspheres of batch A and B in ratio of 3:1 w/w, which produced desirable in vitro release profile. In vivo absorption study showed that insulin-loaded microspheres provided a serum insulin level of 20-40 microU/ml up to 40 days. Biocompatibility study provided evidence of normal inflammatory and foreign body reactions, which were characterized by the presence of macrophages, fibroblasts and foreign body giant cells. Neither necrosis nor tissue damage was identified. At the end of 12 weeks, no distinct histological differences were observed in comparison to the control tissue samples. In conclusion, insulin-loaded PLGA microspheres controlled the in vivo absorption of insulin to maintain the basal insulin level for longer period and the delivery system was biocompatible.

Animals↗

In-vitro release and oral bioactivity of insulin in diabetic rats using nanocapsules dispersed in biocompatible microemulsion.

This study evaluated the potential of poly(iso-butyl cyanoacrylate) (PBCA) nanocapsules dispersed in a biocompatible microemulsion to facilitate the absorption of insulin following intragastric administration to diabetic rats. Insulin-loaded PBCA nanocapsules were prepared in-situ in a biocompatible water-in-oil microemulsion by interfacial polymerisation. The microemulsion consisted of a mixture of medium-chain mono-, di- and tri-glycerides as the oil component, polysorbate 80 and sorbitan mono-oleate as surfactants and an aqueous solution of insulin. Resulting nanocapsules were approximately 200 nm in diameter and demonstrated a high efficiency of insulin entrapment (> 80%). In-vitro release studies showed that PBCA nanocapsules could suppress insulin release in acidic media and that release at near neutral conditions could be manipulated by varying the amount of monomer used for polymerisation. Subcutaneous administration of insulin-loaded nanocapsules to diabetic rats demonstrated that the bioactivity of insulin was largely retained following this method of preparing peptide-loaded nanocapsules and that the pharmacodynamic response was dependent on the amount of monomer used for polymerisation. The intragastric administration of insulin-loaded nanocapsules dispersed in the biocompatible microemulsion resulted in a significantly greater reduction in blood glucose levels of diabetic rats than an aqueous insulin solution or insulin formulated in the same microemulsion. This study demonstrates that the formulation of peptides within PBCA nanocapsules that are administered dispersed in a microemulsion can facilitate the oral absorption of encapsulated peptide. Such a system can be prepared in-situ by the interfacial polymerisation of a water-in-oil biocompatible microemulsion.

Administration, Oral↗

Metallic dental material biocompatibility in osteoblastlike cells: correlation with metal ion release.

Ions released from metallic dental materials used in orthodontic appliances could induce undesirable effects on cells and tissues. This study evaluates the biocompatibility of two of the most labile components of metallic dental alloys on osteoblastlike cells. The influence of protein and ions on metal dissolution properties is also investigated using different electrolyte solutions. Morphological alterations, cell growth, and differentiation of osteoblasts were assessed after exposure to pure metals (Ag, Cu, Pd, Au) and Ni-Ti alloy and correlated with the kinetics of elements released into the culture media. Results showed that Cu and Ag were the most cytotoxic elements and the other metals were biocompatible with the osteoblasts. The parameters of biocompatibility were correlated with the levels of ions detected into the culture media. Metal ions induced cell death through early mitosis arrest, apoptotic phenomena, and necrotic processes. Voltammograms showed that anions and proteins interfered in the corrosion process. Fetal bovine serum (FBS) strongly affected the electrochemical process, decreasing the oxidation rate of the metals. In conclusion, copper and silver ions showed a time-dependent low biocompatibility, which correlated with the concentration of released ions. The dissolution of the metallic materials was dependent on the composition of the simulated biological media.

Animals↗

Glass ionomer cements: a review of composition, chemistry, and biocompatibility as a dental and medical implant material.

Glass ionomer cements are a group of materials based on the acid/base reaction between poly(alkenoic) acid and an ion-leachable silicate glass. The material was developed in dentistry as a tooth restorative material that released fluoride ions over an extended time, bonded to tooth structure, and was very biocompatible. Its use in dentistry was initially limited by its slow setting time and lack of strength; however, modern formulations of the material have yielded materials with properties that are clinically useful in dentistry. Its biocompatibility, osteoconductive behavior, and ability to bond to bone and metals have generated interest in the material for medical applications. Glass ionomer cements in medicine have been used as bone cements, implants to replace ossicular bones of the inner ear, as well as other craniofacial implants. The early release of fluoride and aluminum ions and release of polyacids have been implicated in tissue biocompatibility in medical use. Additional material development is necessary to optimize its properties for use in medicine. This article reviews the literature written on the composition, chemistry, fluoride release, biocompatibility, and medical uses of glass ionomer cements.

Biocompatible Materials↗

[Comparative analysis of the efficacy and biocompatibility of various methods of dialysis].

BACKGROUND/AIM: The efficacy and biocompatibility of hemodialysis have a singnificant impact on dialysis patient morbidity and mortality rate. The aim of our study was to compare the efficacy and biocompatibility of different hemodialysis modalities in our patients. METHODS: A total of 55 patients were included in the study, and on the basis of dialysis modality, they were divided in four groups: group I--post-dilution on-line hemodiafiltration (n=15), group II--bicarbonate high-flux polysulphone hemodialysis (n=15), group III--bicarbonate low-flux polysulphone hemodialysis (n=15), and groupe IV--bicarbonate cuprophane hemodialysis (n=10). The efficacy was evaluated on the basis of urea reduction rate (URR), urea Kt/V index and serum beta2-microglobuline reduction rate, and the biocompatibility was evaluated on the basis of the leukocyte count fall during the first fiftheen minutes of dialysis session, and of the serum C-reactive protein (CRP) level. RESULTS: The highest mean URR was achieved in the group I (70.53 +/- 6.49%), and it was significantly higher in comparison with the average URR in the group IV (54.8 +/- 6.35%) (p = 0.001). The average value of urea Kt/V index in the group I (1.48 +/- 0.22) was significantly higher in comparison with the average value in the group II 1.30 +/- 0.22 (p < 0.05), group III (1.05 +/- 0.22), and group IV (0.98 + 0.22) (p = 0.001). Serum beta2-microglobuline reduction rate was 68.93 +/- 8.25% in the group I, and 58.86 +/- 7.98% in the groupe II (p = 0.01). During the first 15 minutes of hemodialysis the leukocyte number was decreased by 12.57 +/- 9.35% in the group 1, 13.61 +/- 9.64% in the group 11, 18.3 +/- 13.24 in the group III and 62.3 +/- 15.4 in the group IV, on average. The mean serum level of CRP was 9.4 +/- 6.47 mg/l in the group IV, and less than 3.5 mg/l in the group I of the patients (p = 0.001). CONCLUSION: Postdilution on-line hemodiafiltration in comparison with standard hemodialysis provided the more effective elimination of small and middle uremic toxins molecules and a significantly higher degree of biocompatibility. The patients treated with standard hemodialysis frequently do not achieve the minimal value of urea Kt/V index prescribed by National Kidney Foundation-Dialysis Outcomes Quality Inatiatives standards. These patients also have significantly higher serum CRP values which suggest the state of chronic microinflammation.

Adolescent↗

Rationale for the design of biomaterials and the evaluation of their biocompatibility.

The biocompatibility of a material can be considered as the ideally expectable result of its interactions with living tissues with which it is interfaced. This property determines the ability of devices involving this material in their constitution, to correctly assume their ascribed function; reciprocally a bad fitting, between devices and their intended use, coming from a non-optimized design or from an inappropriate prescription, may alter the original biocompatibility of constitutive materials. Accordingly, the actual biocompatibility of a biomaterial depends upon both its intrinsic properties and the application in which it is involved. Such considerations must be taken into account by specialists who try to design more performant biomaterials, or new assist devices, should they be implantable or not; but they draw also methodological guidelines for the evaluation of the biocompatibility of these biomedical products.

Biocompatible Materials↗

Biocompatibility in transfusion medicine.

The first measurable event upon interaction of artificial surfaces with blood is adsorption of proteins within seconds or minutes. At a later stage, blood cells interact with the surfaces through the initially deposited protein layer. The chemical composition of the surface is only one criterion for differential deposition of various plasma proteins, with molecular motion (polymer chain ends, loops and their flexibility), and topography (roughness, porosity) of the surface decisively influencing the interactions as well. Initially incompatible surfaces, which may be dangerous to the patient, may be rendered compatible by physicochemical surface modifications. Modern methods to estimate biocompatibility have become so sensitive that they may detect biological modifications of the blood after contact with a surface, which has no consequence for the patient. In these cases it is often difficult to decide whether a material should be classified as biocompatible or non-biocompatible. This paper discusses some methods that we have used for the study of biocompatibility of extracorporeal circuitry. It seems to us that minute signs of laboratory evidence for bioincompatibility should not preclude usage of the material in a clinical setting.

Biocompatible Materials↗