PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “CARDIAC VALVES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves in vitro.

OBJECTIVE: To assess the influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves. METHODS: US-made CarboMedics bileaflet valve, China-made Jiuling bileaflet valve and C-L tilting disc valve were tested via a pulsatile flow simulator in the aortic position. Testing conditions were set at mimic cardiac rates of 55 bpm, 75 bpm, 100 bpm with a constant mimic cardiac output of 4 L/min. The mean pressure differences (deltaP), leakage volumes (L(E)V) and closing volumes (C(L)V) across each valve, and effective orifice areas (EOA) were analyzed. RESULTS: Within physiological range, deltaP, L(E)V, and C(L)V decreased as mimic cardiac rate increased, with a large extent of variance. EOA increased along with an increase in mimic cardiac rate. It was a different response in terms of cardiac rate alteration for different types of mechanical prosthetic cardiac valves. CONCLUSION: Mimic cardiac rate change affects hydrodynamics of mechanical prosthetic cardiac valves. Within physiological range, the hydrodynamic of prosthetic bileaflet valve is better than that of tilting disc valve.

Biomechanical Phenomena↗

Initial experimental experience with a "replaceable" cardiac valve prosthesis.

An easily "replaceable" cardiac valve prosthesis has been designed. It consists of two parts: (1) a sewing ring incorporating a circlip and (2) a functioning valve (either mechanical or tissue). The circlip is encased in a sewing ring, which is sutured into the natural valve annulus, and grips the functional part of the prosthesis, thereby preventing dislodgment. A simple instrument has been designed to open the circlip a few millimeters to allow easy removal or insertion of the functional element. This sewing ring/circlip with the functional element of a Björk-Shiley prosthesis was used in 10 baboons undergoing mitral valve replacement. Removal and replacement of the functional element was carried out at a second operation between 1 and 12 weeks later. There were no operative deaths. Baboons were electively killed one day to twelve months after the second operation. There were no complications related to the prosthesis; cardiac catheterization showed normal hemodynamics before and after the second operative procedure.

Animals↗

Staphylococcus aureus induces tissue factor expression in cultured human cardiac valve endothelium.

In vitro infection of cultured human cardiac valve endothelium (HCVE) with Staphylococcus aureus was used as a model to study potential mechanisms of vegetation formation in infective endocarditis. S. aureus was observed to adhere to and be ingested by HCVE. Infection for 8 h resulted in increased levels of procoagulant activity in HCVE, shown to be tissue factor by a specific assay. Mean activity in infected HCVE was 662 +/- 149 (mU/10(5) HCVE +/- 1 SD) versus 221 +/- 78 in control HCVE; surface-expressed activity was 57 +/- 25 in infected monolayers and undetectable (less than or equal to 10) in controls. Bacteria alone had no activity. These results suggest that endothelium may have a functional role in the pathogenesis of S. aureus endocarditis and may provide one potential mechanism for activating coagulation to initiate vegetation formation on a colonized cardiac valve.

Cell Survival↗

Prevalence of asymptomatic cardiac valve anomalies in idiopathic scoliosis.

The prevalence of asymptomatic cardiac valve anomalies was determined in 82 patients (69 females and 13 males) diagnosed as having idiopathic scoliosis and scheduled for corrective surgery (mean age at surgery 16.3 years). The preoperative study in each patient included echocardiography and ultrasound Doppler. Twenty-three valvular anomalies were found in 20 patients (24.4%). The most frequent was mitral valve prolapse. The occurrence of valvular anomalies did not correlate with sex, curve magnitude, or age at diagnosis. Eighteen patients presented a total of 20 comorbid conditions: positive family history of scoliosis (five cases), isthmic spondylolisthesis (five cases), nervous anorexia (two cases), hereditary exostosis, cystic fibrosis, ureteral stenosis, mammary hypoplasia, slipped capital femoral epiphysis, psoriasis, celiac disease, and lactose intolerance. A significant relationship was found between valvular anomalies and comorbidity. Valvular anomalies were detected in 11 out of 64 patients (17.2%) with no comorbidity and in nine out of 18 patients (50%) with a comorbid condition (Chi-square 8.2, p = 0.004). In this latter group of patients, routine echocardiographic study seems advisable in the preoperative evaluation.

Adolescent↗

Comparison of laparoscopic versus open cholecystectomy in patients with cardiac valve replacement.

To evaluate the benefits and safety of laparoscopic cholecystectomy (LC) in patients with cardiac valve replacement (which frequently leads to cholelithiasis), 12 patients with cholelithiasis associated with cardiac valve replacement were studied. The patients were divided into two groups, of 6 patients each, according to the type of operation performed, open cholecystectomy (OC) or LC. The postoperative course was monitored with respect to laboratory data on postoperative days (POD) 1, 3, and 7. The mean duration of operation, blood loss, days to food resumption, length of hospital stay, and morbidity were compared between the two groups. Significant differences (P < 0.05) were found between the OC and LC groups in white blood cell counts on POD 1 (12 980 +/- 3040/mm3 vs 8300 +/- 1590/mm3), days to food resumption (2.7 +/- 0.4 days vs 1.0 +/- 0.7 days), and length of postoperative stay (15.8 +/- 1.0 days vs 10.8 +/- 1.6 days). There were no complications in the LC group, but 1 patient in the OC group had heart failure postoperatively. Our findings indicate the efficacy and safety of LC in patients with cardiac valve replacement.

Adult↗

Pregnancy in patients after homograft cardiac valve replacement.

Thirteen pregnancies in ten patients with homograft cardiac valves resulted in 11 healthy infants, one spontaneous abortion, one elective termination of pregnancy, and the stillbirth of one member of a twin pregnancy. Two forceps deliveries and three cesarean sections were performed and routine antibiotic prophylaxis at the time of delivery was utilized to prevent infective endocarditis in all patients. No hemorrhagic or teratogenic complications were observed, and this was considered directly related to the fact that anticoagulant therapy was rendered unnecessary with the homograft valve--a distinct advantage. A more permissive policy of allowing pregnancy in young women with homograft cardiac valves is suggested by the satisfactory outcome of the pregnancies reported here.

Abortion, Induced↗

Cardiac valve calcification as an important predictor for all-cause mortality and cardiovascular mortality in long-term peritoneal dialysis patients: a prospective study.

Calcification complications are frequent among long-term dialysis patients. However, the prognostic implication of cardiac valve calcification in this population is not known. This study aimed to determine if cardiac valve calcification predicts mortality in long-term dialysis patients. Baseline echocardiography was performed in 192 patients (mean +/- SD age, 55 +/- 12 yr) on continuous ambulatory peritoneal dialysis (mean +/- SD duration of dialysis, 39 +/- 31 mo) to screen for calcification of the aortic valve, mitral valve, or both. Valvular calcification was present in 62 patients. During the mean follow-up of 17.9 mo (range, 0.6 to 33.9 mo), 46 deaths (50% of cardiovascular causes) were observed. Overall 1-yr survival was 70% and 93% for patients with and without valvular calcification (P < 0.0001, log-rank test). Cardiovascular mortality was 22% and 3% for patients with and without valvular calcification (P < 0.0001). Multivariable Cox regression analysis showed that cardiac valve calcification was predictive of an increased all-cause mortality (hazard ratio [HR], 2.50; 95% CI, 1.32 to 4.76; P = 0.005) and cardiovascular death (HR 5.39; 95% CI, 2.16 to 13.48; P = 0.0003) independent of age, male gender, dialysis duration, C-reactive protein, diabetes, and atherosclerotic vascular disease. Eighty-nine percent of patients with both valvular calcification and atherosclerotic vascular disease, 23% of patients with valvular calcification only, 21% of patients with atherosclerotic vascular disease only, and 13% of patients with neither complication died at 1-yr (P < 0.0005). The cardiovascular death rate was 85% for patients with both complications, 13% for patients with valvular calcification only, 14% for patients with atherosclerotic vascular disease only, and 5% for those with neither complication (P < 0.0005). The number of calcified valves was associated with all-cause mortality (P < 0.0005) and cardiovascular death (P < 0.0005). One-year all-cause mortality was 57% for patients with both aortic and mitral valves calcified, 40% for those with either valve calcified, and 15% for those with neither valve calcified. In conclusion, cardiac valve calcification is a powerful predictor for mortality and cardiovascular deaths in long-term dialysis patients. Valvular calcification by itself has similar prognostic importance as the presence of atherosclerotic vascular disease. Its coexistence with other atherosclerotic complications indicates more severe disease and has the worst outcome.

Aged↗

Rifampin blood and tissue levels in patients undergoing cardiac valve surgery.

Single 600-mg capsules of rifampin were given orally to 26 patients as prophylaxis during cardiac valve replacement. Antibiotic concentrations were measured in blood (serum or plasma) and tissue (excised cardiac valve). The serum or plasma levels of rifampin in 18 patients who ingested this drug 2 h before they received preoperative opiates and anticholinergics intramuscularly were not significantly different from the levels in four normal volunteers who received the drug. These levels were 15.9 +/- 6.5 micrograms/ml (mean +/- standard deviation) 2 h after drug administration, 7.1 +/- 4.3 micrograms/ml 8 h after drug administration and 2 h after a mean of 1.4 h on cardiopulmonary bypass, and 1.6 +/- 1.6 micrograms/ml 24 h after drug ingestion. The valve tissue level was 3.8 +/- 2.7 micrograms/g (mean +/- standard deviation; n = 10). This value was 65% of the simultaneous serum and plasma levels and 31% of the peak serum and plasma levels. Eight patients who were given rifampin at the same time that they received other preoperative medications had significantly lower blood levels than the 18 patients who received rifampin 2 h earlier (P less than 0.001). No rifampin was detected in valves from seven of these patients. Decreased rifampin absorption due to simultaneous administration with opiates and anticholinergics was the probable reason for the low plasma and serum levels observed. These data suggest that, if properly dosed, rifampin administered orally gives high blood and valve tissue levels, which are affected minimally by cardiopulmonary bypass in patients undergoing cardiac valve surgery.

Female↗

Autologous blood transfusion in elective cardiac valve operations.

BACKGROUND AND AIM OF STUDY: The aim of this study was to detect any outcome differences between patients who donated autologous blood versus nondonors undergoing nonemergent cardiac valve surgery. Of further interest was whether autologous donors required less allogeneic blood products overall than patients who did not donate. METHODS: We conducted a nested case-control study in which data were collected prospectively on 225 variables. Cases underwent nonemergent, cardiac valve surgery and donated autologous blood products (n = 40). Controls also had nonemergent, cardiac valve surgery but did not donate autologous blood products (n = 120). Cases were matched to controls 1:3 on age (+/-3 years), gender, and New York Heart Association Functional Classification. We controlled for 12 potential confounding variables and examined 17 outcomes of interest. To generate the unadjusted risks of each outcome, chi-square and t-tests were performed comparing cases and controls to each outcome of interest. Then logistic regression analysis investigated the adjusted risk between cases and controls and for the outcomes of interest, each controlling for the potential confounding variables. RESULTS: There were no significant differences between the cases and controls for 11 of the 12 possible confounding variables. Controls had significantly more chronic obstructive pulmonary disorder. There were no significant differences between cases and controls for 13 of the 17 outcomes of interest. Autologous blood donors received more total packed red blood cells (PRBCs) (p = 0.0373) and more total fresh frozen plasma than controls (p = 0.0002). Fewer autologous blood donors required allogeneic packed red blood cell transfusion (p = 0.0134), and the total length of stay was shorter for autologous donors (p = 0.0782). CONCLUSION: Four of the 17 outcomes of interest were different for patients who donated autologous blood versus those who did not. Our experience demonstrated that elective cardiac valve surgery can safely reduce (by 18.3%) the need for allogeneic PRBCs by utilizing preoperative autologous blood donation.

Blood Loss, Surgical↗

Glycoproteins synthesized by cultured cardiac valve endothelial cells: unique absence of fibronectin production.

We have previously reported that cultured porcine cardiac valve endothelial cells released less fibronectin into the culture supernatant when compared to other porcine endothelial cells. In this report we compared the spectrum of glycoproteins synthesized by cardiac valve endothelial cells to glycoproteins synthesized by comparison endothelial cells derived from the ascending thoracic aorta. The cells were endogenously radiolabeled and extracted with detergent. Glycoproteins in the cell extracts were then isolated on wheat germ lectin-agarose and compared using autoradiography following polyacrylamide gel electrophoresis. Fibronectin was identified by immunoblotting with specific antibody. The results showed that the outstanding difference between the endothelial cell types was the virtual absence of fibronectin in the cardiac valve endothelial cell extract.

Animals↗

Actuarial analysis of the risk of undergoing repeat cardiac valve replacement.

One thousand five hundred ninety-eight patients who underwent cardiac valve replacement were reviewed. One hundred fifty-two patients (10 percent) required a second valve replacement. The indications for repeat valve replacement were prosthetic valve dysfunction in 53 patients (35 percent), development of a new valvular lesion in 46 patients (30 percent), simple closure of a perivalvular leak in 14 patients (9 percent), change of the valve poppet in 13 patients (8 percent), severe hemolysis or emboli in 21 patients (14 percent), and prosthetic valve endocarditis in 5 patients (3 percent). The mean preoperative New York Health Association functional class improved from 3 to 1.5 in the nonreoperated patients and from 2.9 to 1.8 in patients who underwent a second valve replacement. Similarly, the mean cardiac index improved from 2.5 to 2.9 and from 2.5 to 2.8 in nonreoperated and reoperated patients, respectively. The operative mortality rate was 14 percent in the nonreoperated patients and 16 percent at second operation in the reoperated patients. Using actuarial techniques, the risk of repeat valve replacement was 1 to 4 percent per year. Long-term survival was compared between groups. Using actuarial techniques, the estimated survival rates at 1, 5, and 10 years were 89 percent, 69 percent, and 52 percent, respectively in nonreoperated patients and 87 percent, 60 percent, and 37 percent in reoperated patients. This study has documented the excellent improvement in functional and hemodynamic state after second cardiac valve replacement. The operative mortality and long-term survival rates were similar to those of the nonreoperated patients. Patients having repeat cardiac valve replacement can expect good improvement in length and quality of life.

Actuarial Analysis↗

A population-based study of appetite-suppressant drugs and the risk of cardiac-valve regurgitation.

BACKGROUND: Recent case reports suggest that a combination of the appetite suppressants fenfluramine and phentermine is associated with an increased risk of cardiac-valve regurgitation. There are also reports of valvular disorders in persons taking fenfluramine or dexfenfluramine alone, particularly for more than three months. METHODS: We conducted a population-based follow-up study and a nested case-control analysis of 6532 subjects who received dexfenfluramine, 2371 who received fenfluramine, and 862 who received phentermine to assess the risk of a subsequent clinical diagnosis of a valvular disorder of uncertain origin. For comparison, we identified a group of 9281 obese subjects who had not taken appetite suppressants who were matched to the treated subjects for age, sex, and weight. All subjects were free of diagnosed cardiovascular disease at the start of follow-up. The average duration of follow-up for all subjects was about four years. RESULTS: There were 11 cases of newly diagnosed idiopathic valvular disorders, 5 after the use of dexfenfluramine and 6 after the use of fenfluramine. There were six cases of aortic regurgitation, two cases of mitral regurgitation, and three cases of combined aortic and mitral regurgitation. There were no cases of idiopathic cardiac-valve abnormalities among the subjects who had not taken appetite suppressants or among those who took only phentermine. The five-year cumulative incidence of idiopathic cardiac-valve disorders was 0 per 10,000 subjects among those who had not taken appetite suppressants (95 percent confidence interval, 0 to 15.4) and among those who took phentermine alone (95 percent confidence interval, 0 to 76.6), 7.1 per 10,000 subjects among those who took either fenfluramine or dexfenfluramine for less than four months (95 percent confidence interval, 3.6 to 17.8; P=0.02 for the comparison with subjects who had not taken appetite suppressants), and 35.0 per 10,000 subjects among those who received either of these medications for four or more months (95 percent confidence interval, 16.4 to 76.2; P<0.001). CONCLUSIONS: The use of fenfluramine or dexfenfluramine, particularly for four months or longer, is associated with an increased risk of newly diagnosed cardiac-valve disorders, particularly aortic regurgitation.

Adult↗

The initial experience with the ATS Medical mechanical cardiac valve prosthesis.

BACKGROUND: From May 1994 through October 2000, a total of 1,146 patients underwent valve replacement with the ATS Medical mechanical cardiac valve prosthesis under a study protocol approved by international ethics committees (non-United States participants) or under a United States Food and Drug Administration-approved Investigational Device Exemption study. The study took place at 19 domestic and three international centers. METHODS: As required by the Food and Drug Administration's Heart Valve Guidance Document, only isolated implants were included in the study (double-valve implants were excluded), with operative and follow-up data collected from each center. RESULTS: Aortic valve replacement (AVR) was conducted in 801 patients (309 with coronary bypass) and mitral valve replacement (MVR) in 345 patients (78 with coronary bypass). Overall operative (< or = 30 days post implant) mortality was 2.1% (17 AVR = 2.1%, 7 MVR = 2.0%), 7 of which (AVR = 4, MVR = 3) were valve related. In 2,086 patient-years (1,459 AVR patient-years, 627 MVR patient-years) of follow-up, there were an additional 50 patient deaths of these, 18 were valve related, 9 due to anticoagulant related bleeding, 5 sudden/unexplained, and 1 each after stroke, thrombosis, prosthetic valve endocarditis, and thromboembolism. Late (>30 days post implant) valve-related complications included: transient and chronic thromboembolism (27 AVR (linearized rate 1.85%/patient-year) and 20 MVR (3.19%/patient-year), of which 11/47 (0.53%/patient-year) had chronic deficits, thrombosis (1 AVR = 0.07%/patient-year and 4 MVR = 0.64%/patient-year), paravalvular leak (10 AVR = 0.69%/patient-year and 8 MVR = 1.28%/patient-year), anticoagulant related hemorrhage (34 AVR = 2.33%/patient-year and 8 MVR = 1.28%/patient-year), prosthetic valve endocarditis (3 AVR = 0.21%/patient-year and 2 MVR = 0.32%/patient-year), and structural valve failure or dysfunction (0%). Echocardiographic gradients were proportional to valve size and did not significantly change over the follow-up period. CONCLUSIONS: This study documented the ATS Medical mechanical cardiac valve prosthesis to be a valuable addition to the surgeon's armamentarium in the treatment of cardiac valvular disease.

Aged↗

[Long-term results of cardiac valve replacement: a 10- to 25-year retrospective study].

A total of 149 patients who underwent cardiac valve replacement between January, 1964 and June, 1979 in our institution have been survived more than 10 years postoperatively. The prosthetic valves primary employed in this series were both mechanical valve such as Starr-Edwards, Smeloff-Cutter, Wada-Cutter, Lillehei-Kaster valves and biological valve such as Hancock valve. Of these, 69 patients (46%) implanted with Starr-Edwards or Wada-Cutter valve were not anticoagulated postoperatively, and 52 (53%) underwent reoperation mainly for valve-related complications or aggravated other valve lesions during the follow-up period. One hundred and thirteen patients were confirmed to be alive at the end of June, 1989, with the follow-up period of 10 to 25 years. Of these, 98 patients (87%) are in the NYHA I or II at the present time. Other twenty-two patients were dead and fourteen were lost to follow-up over 10 years after operation. Although cardiac valve replacement may improve the longevity and the quality of life, available prosthetic valves were not ideal both in material and design. The increased risk of thrombogenesis of mechanical valve and the limited durability of biological valve necessitated re-replacement in the long-term period. Therefore, in addition to selection of the appropriate valve prosthesis, and optimal prevention of valve-related complications, early diagnosis and treatment of these complications are important to improve the long-term results of cardiac valve replacement.

Adolescent↗

Focal and patchy cardiac valve lesions: a clinicopathological review.

Pathologists and surgeons often encounter cardiac valves with focal or patchy abnormalities either at postmortem examination or during the assessment of a valve removed at surgery. Many health professionals including nurses, cardiologists, echocardiographers, sonographers and radiologists may be called upon to assess these lesions. With the development of increasingly more sophisticated and sensitive imaging techniques, including transesophageal echocardiography and magnetic resonance imaging, more valve lesions are being discovered. Many patients with metabolic abnormalities, systemic diseases or storage disease have valvular findings. Some are characteristic and distinctive for the specific disease, while others are seen in numerous diseases. Most patients develop age-related valvular changes, and these are more frequently encountered with the aging population. A practical approach the health professional should take to assess these valve lesions is given. The major categories of disease that produce focal lesions of the cardiac valves are presented.

Diagnostic Imaging↗

Factors affecting warfarin therapy following cardiac valve surgery.

OBJECTIVE: To determine the factors that affect the initial response to warfarin therapy in Korean patients after cardiac valve surgery. METHODS: A retrospective analysis of 127 patients who had undergone cardiac valve surgery at Seoul National University Hospital was performed. On the first day, most patients received warfarin 5 mg, while some received an individualized warfarin dose according to their physician's decision. Doses to be given on the following days were determined based on daily international normalized ratio (INR) and the previous doses. To measure warfarin sensitivity, the warfarin dose index (WDI), defined as the INR divided by the mean warfarin dose administered during the preceding 3 days, was introduced. The effects of age, gender, weight, serum albumin concentration, baseline INR, cardiopulmonary bypass time, and concurrent administration of amiodarone were evaluated. RESULTS: The patients' weight, initial serum albumin concentration, and baseline INR value influenced their initial response to warfarin. The initial WDI correlated negatively with the initial serum albumin concentration (p < 0.001) and body weight (p < 0.05) and positively with the baseline INR (p < 0.01). The initial WDI of the patients taking amiodarone was significantly higher (mean +/- SD 0.74 +/- 0.34) than that of patients without amiodarone (0.46 +/- 0.22) (p < 0.001). Maintenance doses correlated negatively with the initial warfarin response (p < 0.001) and positively with body weight (p = 0.053). CONCLUSIONS: The factors associated with an increased initial warfarin response in patients after cardiac valve surgery were high baseline INR, low postoperative serum albumin concentration, and concurrent administration of amiodarone. Thus, patients with any of these factors should receive a smaller initial warfarin dose. Also, to predict the warfarin maintenance dose from the initial response, the effect of transient changes in the sensitivity to warfarin during the initial period should be considered.

Adult↗