PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Coagulation factor VIII”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Long-term expression of human coagulation factor VIII and correction of hemophilia A after in vivo retroviral gene transfer in factor VIII-deficient mice.

Hemophilia A is caused by a deficiency in coagulation factor VIII (FVIII) and predisposes to spontaneous bleeding that can be life-threatening or lead to chronic disabilities. It is well suited for gene therapy because a moderate increase in plasma FVIII concentration has therapeutic effects. Improved retroviral vectors expressing high levels of human FVIII were pseudotyped with the vesicular stomatitis virus G glycoprotein, were concentrated to high-titers (10(9)-10(10) colony-forming units/ml), and were injected intravenously into newborn, FVIII-deficient mice. High-levels (>/=200 milliunits/ml) of functional human FVIII production could be detected in 6 of the 13 animals, 4 of which expressed physiologic or higher levels (500-12,500 milliunits/ml). Five of the six expressers produced FVIII and survived an otherwise lethal tail-clipping, demonstrating phenotypic correction of the bleeding disorder. FVIII expression was sustained for >14 months. Gene transfer occurred into liver, spleen, and lungs with predominant FVIII mRNA expression in the liver. Six of the seven animals with transient or no detectable human FVIII developed FVIII inhibitors (7-350 Bethesda units/ml). These findings indicate that a genetic disease can be corrected by in vivo gene therapy using retroviral vectors.

Animals↗

T cell recognition of the A2 domain of coagulation factor VIII in hemophilia patients and healthy subjects.

Hemophilia A patients treated with coagulation factor VIII (FVIII), and also some healthy subjects, may develop anti-FVIII antibodies (Ab), whose synthesis is driven by FVIII-specific CD4+ T cells. Some Ab block the procoagulant function of FVIII (inhibitors). Many inhibitors recognize epitopes on the FVIII A2 domain. Here, we have sought to identify A2 epitopes recognized by CD4+ T cells. We tested the proliferative response of CD4+ blood lymphocytes (BL) from hemophilia patients and healthy subjects, to overlapping synthetic peptides spanning the A2 domain sequence. Many A2 peptides induced proliferative responses of CD4+ BL from one or more subjects. The peptide-induced responses were strongest in hemophilia patients with inhibitors, weakest in healthy subjects. A2 peptides comprising residues 371-400, 621-650 and 671-690 elicited frequent and strong responses in hemophilia A patients, and especially in those with inhibitors. Healthy subjects recognized frequently only the sequence 371-400. A three-dimensional model of the A2 domain suggests that these CD4+ epitope sequences have structural features typical of 'universal' CD4+ T epitopes.

Adolescent↗

An enzyme immunoassay (ELISA) for the quantitation of human factor VIII coagulant antigen (VIII:CAg).

For the purposes of prenatal diagnosis and carrier detection of haemophilia A, an enzyme linked immunosorbent assay (ELISA) was developed for the quantitation of plasma Factor VIII coagulant antigen (VIII:CAg). It is based upon a human antibody. Results are compared to assays for Factor VIII coagulant activity (VIII:C) and Factor VIII related antigen (VIIIR:Ag) in plasma from 30 normal female individuals, 5 fetuses from mothers normal with respect to bleeding status, 10 obligate carriers of haemophilia A, 10 patients with haemophilia A, 5 with von Willebrand's disease, and 5 with haemophilia B. The ELISA developed is simpler than previously published VIII:CAg methods owing to its use of total IgG instead of immunologically affinity-purified antibodies. It is specific (as judged from clinical results), sensitive (detection limit: 0.005 units/ml), and sufficiently precise (between-assay coefficient of variation: 11%) for the purposes mentioned. The coefficient of correlation between VIII:CAg and VIII:C results is 0.86. The introduction of ELISA for quantitating VIII:CAg represents an advantage as compared to existing immunoradiometric assays (IRMA) mainly due to the stable and non-radioactive reagents used in the ELISA.

Antigens↗

[Retroviral-mediated high efficient in vitro expression of human coagulation factor VIII].

OBJECTIVE: To develop a retroviral-mediated high efficient expression system of human coagulation factor VIII. METHODS: The retroviral vector LNC-VIIIBD was generated by cloning a B-domain-deleted FVIII cDNA (760aa - 1639aa) into retroviral vector pLNCX. Several cell lines including NIH3T3, CHO, COS-7 and human hepatic cell line L-02 were infected with viral supernatant from the highest productive PA317 clones. The antigen and procoagulant activity of human FVIII in the cell culture medium were measured by ELISA assay and one-stage method, respectively. RT-PCR was performed for the detection of F VIII BD mRNA. RESULTS: Human FVIII was expressed in all four target cells. The highest expression was observed in NIH3T3, the procoagulant activity of secreted FVIII was up to 1.6 U, and the FVIII antigen was 500 ng by 10(6) cells/ml in 24 hours, respectively. CONCLUSION: The constructed retroviral vector was able to generate high level expression of human FVIII in some cell lines, and it might have potential utility in the gene therapy for Hemophilia A.

3T3 Cells↗

LMAN1 and MCFD2 form a cargo receptor complex and interact with coagulation factor VIII in the early secretory pathway.

Mutations in LMAN1 (ERGIC-53) and MCFD2 are the causes of a human genetic disorder, combined deficiency of coagulation factor V and factor VIII. LMAN1 is a type 1 transmembrane protein with homology to mannose-binding lectins. MCFD2 is a soluble EF-hand-containing protein that is retained in the endoplasmic reticulum through its interaction with LMAN1. We showed that endogenous LMAN1 and MCFD2 are present primarily in complex with each other with a 1:1 stoichiometry, although MCFD2 is not required for oligomerization of LMAN1. Using a cross-linking-immunoprecipitation assay, we detected a specific interaction of both LMAN1 and MCFD2 with factor VIII, with the B domain as the most likely site of interaction. We also present evidence that this interaction is independent of the glycosylation state of factor VIII but requires native calcium concentration in the endoplasmic reticulum. The interaction of MCFD2 with factor VIII appeared to be independent of LMAN1-MCFD2 complex formation. These results suggest that LMAN1 and MCFD2 form a cargo receptor complex and that the primary sorting signals residing in the B domain direct the binding of factor VIII to LMAN1-MCFD2 through calcium-dependent protein-protein interactions. MCFD2 may function to specifically recruit factor V and factor VIII to sites of transport vesicle budding within the endoplasmic reticulum lumen.

Animals↗

Factor VIII coagulant antigen in hemophilic plasma: a comparison of five alloantibodies.

Five independent alloantibodies directed to factor VIII coagulant antigen (VIII:CAg) were assessed against normal, von Willebrand's disease, and severe hemophilia A plasmas. Immunoradiometric assays (IRMAs) were developed for each antibody, one of which had arisen "spontaneously" and four in transfused hemophiliacs. The correlations between assays were very high for normal, vWd, and both CRM+ and CRM- hemophiliacs. This suggests that IRMAs maybe developed from almost any reasonably high titered alloantibody and used with confidence in diagnosing CRM- hemophilia A in utero by fetoscopy.

Antibody Specificity↗

Expression of human coagulation factor VIII in adipocytes transduced with the simian immunodeficiency virus agmTYO1-based vector for hemophilia A gene therapy.

We demonstrate that transduction of adipocytes with a simian immunodeficiency virus agm TYO1 (SIVagm)-based lentiviral vector carrying the human coagulation factor VIII gene (SIVhFVIII) resulted in expression of the human FVIII transgene in vitro and in db/db mice in vivo. Cultured human adipocytes were transduced with the SIVagm vector carrying the GFP gene in a dose-dependent manner and transduction of adipocytes with SIVhFVIII resulted in efficient expression of human coagulation factor VIII (hFVIII; 320 +/- 39.8 ng/10(6) adipocytes/24 h) in vitro. Based upon successful transduction of adipocytes by SIV vectors carrying the lacZ gene in vivo in mice, the adipose tissue of db/db mice was transduced with SIVhFVIII. There was a transient appearance of human FVIII in mouse plasma (maximum 1.8 ng/ml) on day 11 after the injection. Transcripts of human FVIII transgene and human FVIII antigen also were detected in the adipose tissue by RT-PCR and immunofluorescence, respectively, on day 14. Emergence of anti-human FVIII antibodies 14 days after the injection of SIVhFVIII may explain the disappearance of human FVIII from the circulation. These results suggest that transduction of the adipocytes with vectors carrying the human FVIII gene may be potentially applicable for gene therapy of hemophilia A.

Adipocytes↗

Stability of canine factor VIII: coagulant activity in vitro.

A pilot study was undertaken to assess the stability of canine factor VIII:coagulant (FVIII:C) activity over three days, under various storage conditions (plasma at 4, 20 and 37 degrees C, whole blood at 4 and 20 degrees C). Blood collected from normal and hemophiliac dogs was used. Both plasma and whole blood samples appeared to be stable for up to 48 h at 4 and 20 degrees C. A subsequent study evaluated FVIII:C stability at 4 and 20 degrees C when stored as whole blood only. Samples were tested at 0, 24 and 48 h after collection. At 4 degree C there was a significant decline at 24 h (p less than 0.05), from 110% to 97% (mean values). Although the mean value was further decreased at 48 h (89%) this was not significant (p greater than 0.05). No significant change in FVIII:C activity was observed in whole blood stored at 20 degrees C for 24 or 48 h (110% and 107% respectively). These results suggest that canine whole blood samples collected into sodium citrate stored at 20 degrees C are adequate for routine FVIII:C assay for up to 48 h after collection.

Animals↗

[Activated partial thromboplastin time. Evaluation of sensitivity and validity for determination of factor VIII coagulant activity].

The authors evaluate the sensibility and validity of some reagents for activated partial thromboplastin time during construction of a curve for measurement of factor VIII coagulant activity. For every reagent three clotting factor VIII deficient plasmas have been used; Baldacci, Dade and Behering. Significant differences in results between every reagent for aPTT and laboratory have been observed. By these results the Authors show the best reagent for aPTT. Future fields of research have been analyzed.

Adolescent↗

The interaction of the calcium- and integrin-binding protein (CIBP) with the coagulation factor VIII.

The gene encoding the C-terminal part of A1-domain of human blood coagulation factor VIII (FVIII), a 110-amino acid fragment from Ala(227) to Arg(336), namely A1(Delta1-226), was cloned and used as a 'bait' to screen a protein, which might interact with this region by using the yeast two-hybrid system. A gene coding for a related protein of FVIII named calcium- and integrin-binding protein (CIBP) was isolated from the normal human liver cDNA library. The results were confirmed by using the mammalian two-hybrid system and coimmunoprecipitation. The gene coding for CIBP was constructed by polymerase chain reaction (PCR) and then cotransfected with the B-domain-deleted FVIII gene into mammalian cell lines using the expression vector of FVIII for transient or stable expression. The culture supernatant was collected and analyzed both by enzyme-linked immunosorbent assay (ELISA) for FVIII antigen level and by one-stage method for procoagulant activity. Coexpressed with CIBP, the antigen level of FVIII in the mammalian cell line baby hamster kidney (BHK) cells increased up to about 170% and its bioactivity rose accordingly.

Animals↗

Manufacturing challenges in the commercial production of recombinant coagulation factor VIII.

Advances in gene technology have led to the development of a method to manufacture recombinant coagulation Factor VIII (rFVIII) for haemophilia A. Because rFVIII is a large and complex protein, its commercialization has required that many challenges in manufacturing, purification and processing be overcome. In order to license the first generation of rFVIII (Kogenate) in 1993, Bayer Corporation invested over 10 years in research and manufacturing development. Seven additional years were subsequently devoted to research and manufacturing improvements in order to accomplish the recent licensing of a second rFVIII product (KOGENATE Bayer or Kogenate FS). This product differs from its predecessor, in that human albumin is removed from the purification and the formulation steps. In addition, fewer chromatography steps are involved resulting in greater yields per mL of conditioned medium, and a solvent-detergent viral inactivation step replaces the heat-processing step used for the previous product. Despite these changes in the manufacturing, the protein backbone and carbohydrate structure of the final rFVIII molecule are identical. The complexity of the production processes is reflected by over 100 000 manufacturing data entries and by 600 quality control tests for each batch of rFVIII. Manufacturers are continuing to develop the next generation of rFVIII, which will be produced without the addition of any human or animal proteins or byproducts. Investments in research, development and manufacturing technology are expected to result in the development of new products with enhanced safety profiles, and in an increase in the production capacity for products that are chronically in short supply.

Drug Design↗

Detection of haemophilia carriers: multivariate analysis compared with discriminant analysis using up to five factor VIII variates.

Multivariate analysis is potentially superior to the linear discriminant analysis which is commonly used to identify carriers of haemophilia. Our aim was to compare these two statistical methods, and to find which factor VIII variates most effectively partitioned carrier and normal subjects. In this study we assayed one- and two-stage factor VIII coagulant activity, factor VIII related antigen by electroimmunoassay and by fluoroimmunoassay, and ristocetin co-factor in 50 normal females and 50 carriers of haemophilia. From the results we calculated multivariate ellipses which circumscribed the normal and the carrier populations, and we displayed these on the monitor of a microcomputer. These ellipses separated the two populations better than linear discriminants calculated on the same data. Multivariate analysis correctly identified 94% of the carriers whereas discriminant analysis correctly identified only 84%. Discriminant analysis gave poorer results because the statistical assumption of equal variance was breached, whereas the assumption of multivariate normality was upheld. Of the five factor VIII variates, two-stage factor VIII coagulant activity and factor VIII related antigen by electroimmunoassay correctly identified the most subjects. Ristocetin co-factor did not improve the diagnostic ability, either when in lieu of or when added to factor VIII related antigen.

Antigens↗

A HindIII RFLP and a gene lesion in the coagulation factor VIII gene.

The presence and inheritance of restriction fragment length polymorphisms (RFLPs) and gene lesions in the coagulation factor VIII gene were investigated in 15 hemophilia families. An abnormal HindIII 2.6-kb band, previously detected in a severe hemophiliac, was observed in a not severely affected patient and also in the normal gene of a woman carrying a hemophilic gene in which the lesions was found. The TaqI site in exon 24 of this defective gene was removed by a C to T transition causing an amino acid change (Arg----Gln). Very low amounts of factor VIII activity and antigen were detected in the severely affected grandson. The presence of the HindIII 2.6-kb fragment in both normal and pathological genes indicates that a factor VIII RFLP without functional meaning was found. Its frequency, determined in 60 chromosomes, is 0.18. Double digestions enabled us to map the polymorphic site 3' to the exon 19.

Antigens↗

Molecular analysis of the heavy chain variable region genes of human hybridoma clones specific for coagulation factor VIII.

HemophiliaA is a X-linked hematologic disorder characterized by undetectable or low amounts of functional coagulation factor VIII (FVIII). Replacement therapy induces FVIII neutralizing antibody (Ab) (inhibitor) in a proportion of patients which makes further treatment of these patients ineffective and costly. To envisage mechanisms underlying inhibitor development, seven hybridoma clones specific for FVIII were generated from two hemophilia A patients with high titer of inhibitor. Specificity and isotype of the monoclonal antibodies (mAbs) were determined by ELISA. Immunoglobulin (Ig) variable region heavy (VH) chain gene family usage was identified by RT-PCR using VH1-6 specific primers. Nucleotide sequences of the VH gene of FVIII specific clones were determined and aligned to the most homologous germ line genes in the GenBank. Analysis of the expressed VH genes by RT-PCR revealed that the hybridomas utilized either the VH1 (71%) or the VH3 (29%) gene family. Three VH domains were encoded by V1-69 (DP-10),V1-2 (DP-8), and V1-8 (DP-15) genes and two by V1-18 (DP-14) gene, all from the VH1 gene family. Of theVH3-gene family expressing clones, one belonged to V3-66 (DP-86) and the other one to V3-21 (DP-77) germline genes. The CDR3 length was found to be highly different amongst these clones ranging from 11 to 22 amino acid residues. These data suggest that FVIII-specific Abs preferentially use VH gene segments derived from VH1 gene family. Diversity of the expressed VH genes and their CDR3 length implies that different epitopes are recognized by these mAbs.

Adult↗

An efficient retrovirus-mediated transduction of human blood coagulation factor VIII cDNA in regenerating rat liver.

A retrovirus-mediated transduction of B-domain-deleted human blood coagulation factor VIII (FVIII-B) was attempted in partially hepatectomized rats. FVIII-B cDNA was inserted into a retroviral vector (pLNSX) and infective recombinant virus particles were produced in packaging cell lines (psi2 and PA317). Transfection of mouse NIH-3T3 cells with the FVIII-B cDNA inserted recombinant viruses, followed by G418 selection, gave a viral titer of 3.5 x 10(4) CFU/ml. FVIII-B protein, as well as FVIII-B mRNA, was detected in these cells. Transfusion of FVIII-B-expressing retrovirus particles into the tail vein of rats subjected to partial hepatectomy resulted in a relatively higher level of FVIII-B expression in liver and circulating plasma as compared with the sham-operated rats. These results indicate that the augmentation of FVIII activity in the blood of an animal by retroviral gene delivery can be enhanced by partial hepatectomy, and that the retrovirus-mediated FVIII-B cDNA delivery to regenerating liver may be an alternative method for the expression of FVIII-B cDNA in vivo.

3T3 Cells↗

3-Dimensional structure of membrane-bound coagulation factor VIII: modeling of the factor VIII heterodimer within a 3-dimensional density map derived by electron crystallography.

Despite recent studies, the organization of coagulation factor VIII (FVIII) on a phospholipid (PL) membrane is not known in detail. Thus, 2-dimensional (2D) crystals of human FVIII lacking the B domain were prepared for electron microscopy onto negatively charged PL monolayers. The 3-dimensional (3D) density map of the PL-bound FVIII protein was calculated at 1.5 nm. Existing atomic data and models for FVIII domains were fitted unambiguously within the 3D density map of the molecule. FVIII domains arrangement followed a compact spiral organization with the A3 domains in close association with the C1 and C2 domains near the PL surface. Viewed toward the membrane the A domains' heterotrimer is oriented side-on with the pseudo-3-fold axis almost parallel to the PL surface and A1 fully covering C1. The C2 domain is partially overlapped by the A2 domain of an adjacent molecule in the 2D crystal, favoring close packing. Viewed parallel to the membrane, C2 is slightly inclined to the PL surface covering an area of 12 nm(2). Four C2 loops are embedded within the lipid monolayer at about 0.7 to 1.0 nm depth. C1 forms almost a right angle with C2, its long axis nearly parallel to the membrane. The proposed structure for membrane-bound FVIII results from modeling of the FVIII domains within a 3D density map obtained from electron crystallography and accords with the main biochemical and structural information known to date. A model is proposed for FVIIIa and factor IXa assembly within the membrane-bound factor X-activating complex. (Blood. 2002;99:1215-1223)

Binding Sites↗

Factors affecting the performance of factor VIII coagulant activity assays. Results of proficiency surveys of the College of American Pathologists.

To evaluate sources of interlaboratory variation in factor VIII coagulant assays and the effects of uniform calibration on it, data were analyzed from Survey Set H2-C, 1987, of the College of American Pathologists, Northfield, Ill, into which the College of American Pathologists Reference Preparation for Factor VIII was incorporated. Peer group performance and its improvement by uniform calibration were evaluated by comparing means, precisions, and numbers of acceptable survey scores. Results showed a poorer performance by less experience laboratories and by those that used undesirable calibrators. Substantial improvement was seen with uniform calibration, especially among laboratories that had employed poorer calibrators. Although variance component analysis showed that the type of calibrator was the most important contributor to interlaboratory variation, it accounted for only 10% of total variability. Participant summaries and questionnaires that spanned several years revealed steady improvement in methodology but no striking changes in interlaboratory variation.

Analysis of Variance↗

D-dimer, factor VIII coagulant activity, low-intensity warfarin and the risk of recurrent venous thromboembolism.

BACKGROUND: Elevated plasma D-dimer and factor VIII coagulant activity (FVIIIc) may be associated with the risk of recurrent venous thromboembolism (VTE). OBJECTIVES: To evaluate D-dimer and FVIIIc as risk factors for recurrent VTE and assess the efficacy of extended low-intensity warfarin (target International Normalized Ratio 1.5-2.0) in preventing recurrence by biomarker level. PATIENTS AND METHODS: In the Prevention of Recurrent Venous Thromboembolism trial, 508 idiopathic VTE patients treated for > or = 3 months with full-intensity warfarin, and who had stopped warfarin for 7 weeks on average, were randomized to low-intensity warfarin or placebo and followed for 2.1 years for recurrent VTE. Prerandomization blood samples were analysed for D-dimer and FVIIIc. RESULTS: One-third of participants had elevated baseline D-dimer (> or = 500 ng mL(-1)) and one-fourth, elevated FVIIIc (> or = 150 IU dL(-1)). Adjusting for other risk factors, the hazard ratios (HRs) for recurrent VTE with elevated D-dimer or FVIIIc were 2.0 [95% confidence interval (CI) 1.2-3.4] and 1.5 (95% CI 0.8-2.8), respectively. The association of elevated D-dimer with recurrence was larger among patients with one prior VTE (HR 3.2, 95% CI 1.3-8.0) than in patients with more than one event (HR 1.4, 95% CI 0.7-2.2). For patients with one prior VTE on placebo, the annual recurrence incidence was 10.9% with elevated D-dimer and 2.9% with normal values. Low-intensity warfarin was equally effective in recurrence risk reduction in those with normal or elevated biomarkers. CONCLUSIONS: Among patients with idiopathic VTE, measurement of D-dimer, but not FVIIIc, might be useful for risk stratification. The efficacy of extended low-intensity warfarin therapy did not vary by biomarker level.

Adult↗