PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Contraceptive Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Vasospasm following transsphenoidal tumor removal associated with the arterial changes of oral contraception.

A case of fatal cerebral vasospasm after transsphenoidal removal of a pituitary macroadenoma with suprasellar extension is reported. On the second postoperative day the patient developed headache, lethargy, and cardiorespiratory arrest. Five days later, after recovery from this episode, she developed signs of involvement of the left hemisphere. At that time she demonstrated severe cerebral vasospasm, which was worse in the left supraclinoid segment of the internal carotid artery, and she died 19 days postoperatively. Postmortem examination showed left hemispheric and hypothalamic infarction with subsequent herniation. In addition, pathologic arterial changes usually related to use of oral contraceptives were present.

Adenoma↗

Alveolitis sicca dolorosa after removal of impacted mandibular third molars.

The aim of the investigation was to study the occurrence of alveolitis and other side effects in women taking oral contraceptives after surgical removal of impacted mandibular third molars. Reactions to surgical removal of 156 bilateral third molars were examined in 78 patients. The material was divided into 2 groups. In 1 group, the patients took oral contraceptives of the combined type and in the other group the patients took no contraceptives. Each group was further divided into 2 subgroups: (1) removal of a molar during menstruation; and (2) removal of the contralateral molar in the same patient at the middle of the menstrual cycle. The results showed significantly more alveolitis in the group taking oral contraceptives and in women who were operated on during menstruation. These findings would suggest that oral surgery involving fertile women should be undertaken during periods free from oral contraceptives and menstruation.

Adolescent↗

Laparoscopic removal of an intraperitoneal translocated intrauterine contraceptive device.

The use of an intrauterine contraceptive device (IUD) is often accompanied by various complications, the perforation of the uterus constituting the most dangerous. Here we report the case of a patient who complained of abdominal pains. She had had an IUD inserted 15 months previously. Three months later, as she could no longer see the IUD strings at the external os of the cervix, she underwent pelvic ultrasonography, which did not show the IUD in the uterine cavity. A diagnosis of expulsion of the IUD was made. A few months later, the patient accidentally became pregnant, and decided to have an abortion. From that time on, she started to complain of the above-mentioned symptoms. She had an abdominal X-ray which revealed the IUD in the abdominal cavity. She then underwent a laparoscopic removal of the translocated IUD.

Adult↗

Management of translocated and incarcerated intrauterine contraceptive devices.

Thirty-seven consecutive patients who reported with absent or snapped strings and failed attempts at removal of intrauterine contraceptive devices (IUCD) by hooks or curette were posted for hysteroscopy/laparotomy following a plain X-ray of the pelvis to exclude unrecognized spontaneous expulsion. Direct visualization of the endometrial cavity was invaluable in locating and removing IUCDs, particularly the embedded and fragmented ones. Translocated medicated devices were associated with dense adhesions, suggesting the need for their prompt removal. There appears to be an increased risk of translocation in lactating women.

Adult↗

Recovery of fertility and outcome of planned pregnancies after the removal of Norplant subdermal implants or Copper-T IUDs.

The recovery of fertility after discontinuation of NORPLANT implant use was assessed in ninety women who stated a desire for a new child at the time of removal. Three subjects were lost to follow-up after removal. The cumulative probability of conception in the remaining 87 women was 25, 49, 73 and 86 percent at one, three, six and twelve months after removal, respectively. Nine observations were censored either because of the use of a contraceptive method soon after removal of the implants (n = 7) or separation (n = 2). All other cases were pregnant at the end of two years with exception of three subjects where a male factor for infertility was present. There was no significant correlation between the length of NORPLANT use and the length of the interval from removal to conception. A significantly higher frequency of intervals longer than 6 months was observed among women older than 30 years as compared to younger women. Pathology during pregnancy was cholestasia (n = 5), hypertension (n = 1) and gestational diabetes (n = 1). The outcome was term delivery in 59 cases, premature delivery in 4 cases, and spontaneous abortion in 7 cases. One woman is still pregnant and the outcome is unknown in 4 cases. One premature infant died. A contemporary control group of Copper T users enrolled under the same criteria as NORPLANT implant users provided 44 women who had the device removed to become pregnant. The cumulative probability of pregnancy was 27, 69, 84 and 89 at one, three, six and twelve months and all were pregnant by the end of the second year. Six censored observations occurred because of the use of another contraceptive method after removal (n = 3) or loss to follow-up (n = 3). The outcome of pregnancy was term delivery in 23 cases and abortion in 7 cases. Recovery of fertility occurred at a normal rate after NORPLANT implant removal and the incidence of problems detected in the ensuing pregnancy were within the expected range for Chilean women.

Age Factors↗

Location and removal of non-palpable Implanon implants with the aid of ultrasound guidance.

BACKGROUND: Implanon insertion appears to be an easy procedure, but in a small minority of cases difficulties have been encountered with removal if the rod is impalpable. METHODS: Patients were referred to the contraceptive and sexual health service with non-palpable Implanon. Following a clinical assessment and examination of the arm where the implant had been inserted, an ultrasound examination was carried out to identify and locate the implant. These implants were subsequently removed, some under general anaesthesia and others under local anaesthesia. RESULTS: Twenty-seven patients were referred to the unit with impalpable Implanon rods. In four cases the rods were palpable and were removed in the clinic setting without the need for further intervention. Positive identification of the implants was achieved in 21 of the remaining 23 cases using ultrasound. No implant was detected in two cases and etonogestrel was not demonstrated serologically in either woman, suggesting non-insertion. All 21 Implanon rods identified by ultrasound were successfully removed. In just over 52% of women a previous attempt at removal had been undertaken prior to referral. CONCLUSIONS: It is possible to identify and locate impalpable Implanon rods with the aid of ultrasound, facilitating their subsequent safe removal. Although previous reports have identified the position of 'lost' implants using ultrasound, this is the first case series to discuss measuring the skin/implant depth. This parameter, together with the precise position of the implant (in muscle or fat), aids removal. All health professionals inserting and removing contraceptive implants should have been appropriately trained.

Adult↗

Results of Hysteroscopic Method of Foreign Body Removal out of Uterus Cavity

Recognition of foreign bodies in the uterine cavity is of great importance for successful treatment of secondary infertility: e.g. a piece of intrauterine contraceptive (after a removal failure), suture after cesarean section, or cylindrical and flat small bones after abortions. Sixty-nine foreign bodies were removed with a hysteroscope during 1992-93. Sixty-one of the foreign bodies were intrauterine devices. Twelve patients (19.7%) had had several unsuccessful removal attempts. The remaining eight women (11.9%) underwent fetal bone removals. Removal of ligatures in the area of scar on the uterus after cesarean section was carried out in two patients and both were done under hysteroscopic control. Hysteroscopy allows exact determination of foreign body position in uterus and for their atraumatic removal.

Journal Article↗

Insertion and removal of intrauterine devices.

The intrauterine device (IUD) is an effective contraceptive for many women. The copper-releasing IUD can be used for 10 years before replacement and is a good choice for women who cannot, or choose not to, use hormone-releasing contraceptives. However, some women experience an increase in menstrual blood loss and dysmenorrhea. The progestin-releasing IUD can be used for five years. It may reduce menorrhagia and dysmenorrhea, although some women have increased spotting and bleeding during the first months after insertion. The ideal candidates for IUD use are parous women in stable, monogamous relationships. Pregnancy, unexplained vaginal bleeding, and a lifestyle placing the woman at risk for sexually transmitted diseases are contraindications to IUD use. Insertion of the IUD can take place at any time during the menstrual cycle provided the woman is not pregnant. Before insertion, a bimanual examination and a sounding of the uterus are necessary to determine the uterus position and the depth of the uterine cavity. The IUD is inserted into the uterus according to individual protocols, with the threads cut at a length to allow the patient to check the device's position. Expulsion may occur with both types of IUDs.

Contraception↗

Pharmacokinetic observations on ST-1435 administered subcutaneously and intravaginally.

Plasma levels of ST-1435 were determined by radioimmunoassay in 36 women and three men during treatment with subdermal capsules releasing ST-1435. The total lengths of the capsules used were 180 mm, 90 mm, 30 mm, 15 mm and 7.5 mm. A linear correlation between the mean plasma concentrations of ST-1435 and capsule length was found during the treatment period studied. However, great interindividual variation in plasma levels of ST-1435 between study subjects having similar capsules was observed. In comparison with the mean plasma concentrations in the initial months, only less than half of these plasma concentrations of ST-1435 were measured after six months of treatment, which indicates a short lifetime for this contraceptive system. In two women the disappearance of ST-1435 from the circulation was studied by measuring ST-1435 concentrations in the plasma after removal of a contraceptive vaginal ring (CVR) releasing ST-1435. Triphasic disappearance curves of ST-1435 were found, with half-lives 0.7-1.0 h, 3.1-4.0 h, and 10.7.3-11.8 h.

Adult↗

Retrieval of intrauterine contraceptive devices with missing tails, using Lamicel.

Preliminary cervical dilatation using Lamicel, followed by relatively painless uterine probing was successful in removing 30 of 31 contraceptive devices that had not been removable in the outpatient clinic. This technique is simple, safe, inexpensive and well tolerated. It can be utilized to retrieve intrauterine contraceptive devices with missing tails when other conventional clinic procedures fail.

Biocompatible Materials↗

Pharmacological female contraception: an overview of past and future use.

Female hormonal contraceptive methods have undergone slow change over the past four decades. Due to social, political and legal reasons, as well as medical complications, several new methods have been removed from the contraceptive armamentarium almost as quickly as they have been added. With worldwide unintended pregnancy rates approaching 50% of all pregnancies, there is an increased need for the development of new methods of effective, safe, acceptable hormonal contraception. Pharmacological methods of contraception are reversible and contraceptive steroids are now formulated in pills, patches, intravaginal rings, subdermal implants and injections. All currently marketed formulations are made from synthetic steroids and contain no natural oestrogens or progestins. This article reviews the current state of female contraception and explores future directions.

Administration, Cutaneous↗

Large bowel perforation by intrauterine contraceptive devices.

Two cases of large bowel perforation by intrauterine contraceptive devices are presented. Both the Lippes LoopTM and Dalkon ShieldTM have the potential of evoking omental adhesions and causing bowel perforation. These serious complications justify the immediate removal of a contraceptive device from the peritoneal cavity by either laparoscopy or laparatomy.

Adult↗

Reproductive health in Romania: reversing the Ceausescu legacy.

As a result of the restrictive reproductive health policies enforced under the 25-year Ceausescu dictatorship, Romania ended the 1980s with the highest recorded maternal mortality of any country in Europe--159 deaths per 100,000 live births in 1989. An estimated 87 percent of these maternal deaths were caused by illegal and unsafe abortion. Under the Ceausescu regime, all contraceptive methods were forbidden and induced abortion was available only for women who met extremely narrow criteria. Immediately after the December 1989 revolution that overthrew Ceausescu, the new government removed restrictions on contraceptive use and legalized abortion. This legislative change has had beneficial effects on women's health, seen in the drop in maternal mortality in 1990 to 83 deaths per 100,000 live births--almost half the ratio in 1989. In addition, changes instituted since the revolution have led to the improved availability of reproductive health services and to the creation of new educational and training opportunities related to reproductive health services and to the creation of new educational and training opportunities related to reproductive health. The newly created contraceptive and abortion services have presented health system managers and policymakers with many challenges as they work to expand the availability of high-quality, comprehensive reproductive health care in a setting of economic hardship, political unrest, insufficient infrastructure, and outdated medical knowledge and practice.

Abortion, Legal↗

A randomized comparative study of the TCu380A and Cu-Safe 300 IUDs.

The Cu-Safe 300 is one of the latest additions to the array of available IUDs. It was specifically designed to decrease unwanted side-effects (e.g. bleeding, pain and expulsion) while providing simplicity of insertion, ease of removal and fair contraceptive protection. For comparison, the TCu380A was chosen. Both types were inserted at random in 600 recipients by a group of independent physicians with a long standing experience in intrauterine contraception. Life table analysis was used for comparison over a period of three years. The Cu-Safe 300 produced a slightly but not statistically significant higher pregnancy rate and more expulsions. Removals for bleeding and pain, however, were significantly less frequent. All inserting physicians agreed that insertion and removal of this new device was remarkably easy.

Adolescent↗

Bacteriological cultures of removed intrauterine devices and pelvic inflammatory disease.

Intrauterine devices (IUDs) are highly effective, long-term methods of contraception. Although evidence of a direct association between IUD use and pelvic inflammatory disease (PID) is scarce, concerns about PID related to IUDs use has limited their use throughout the world. We designed this study to examine the effect of IUDs on PID. For the study, we recruited 200 participants from among women who requested an IUD as a means of contraception. The IUDs were removed 36 months later or in case of PID. No PID cases were recorded during the follow-up period. Prior to IUD insertion, 121 women (60.5%) had symptoms and/or signs of lower genital tract infection, whereas during the follow-up period 179 women (89.5%) had symptoms and/or signs of lower genital tract infection. The Papanicolaou smears were negative for Actinomyces throughout the study period. Also, cultures for sexualy transmitted disease microorganisms were negative throughout the study period. Following IUD removal, 189 IUD cultures (94.5%) were positive. The bacterial flora of the removed IUDs consisted of common aerobic and anaerobic microorganisms that do not account for PID. The most common microorganisms identified were Staphylococcus coagulase negative, Eschericia coli, and Enterococcus faecalis. IUDs are a very effective and safe method of contraception if potential recipients are selected carefully. Culture of the removed IUDs and therapeutic management of women with positive cultures are not recommended when women are asymptomatic for PID.

Bacterial Infections↗