PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Dose-volume analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Cost benefit of emerging technology in localized carcinoma of the prostate.

PURPOSE: In a health care environment strongly concerned with cost containment, cost-benefit studies of new technology must include analyses of loco-regional tumor control, morbidity, impact on quality of life, and financial considerations. METHODS AND MATERIALS: This nonrandomized study analyzes 124 patients treated with three-dimensional conformal radiation therapy (3D CRT) and 153 with standard irradiation (SRT) between January 1992 and December 1995, for histologically proven adenocarcinoma of prostate, clinical Stage T1 or T2. Mean follow-up is 1.4 years. Three-dimensional CRT consisted of six or seven coplanar oblique and lateral and, in some patients, AP fields designed to treat the prostate with a 1 to 1.7 cm margin. SRT consisted of 120 degrees bilateral arc rotation. Total doses to prostate were 67 to 70 Gy when pelvic lymph nodes were irradiated or 68.4 to 73.8 Gy when prostatic volume only was treated; dose per fraction was 1.8 Gy. Patients were interviewed weekly for severity of 12 acute intestinal and urinary pelvic irradiation side effects (0 to 4+ grading). Time and effort for 3D RTP and daily treatment with 3D CRT and SRT were recorded. Dose-volume histograms (DVHs) were calculated for gross tumor volume, planning target volume, bladder, and rectum. Actual reimbursement to the hospital and university was determined for 41 3D CRT, 43 SRT, and 40 radical prostatectomy patients treated during the same period. RESULTS: Average treatment planning times (in minutes) were: 101 for 3D conformal therapy simulation, 66 for contouring of target volume and sensitive structures, 55 for virtual simulation, 39 for plan preparation and documentation, 65 for physical simulation, and 20 for approval of treatment plan. Daily mean treatment times were 19 min for 3D CRT with Cerrobend blocking, 16 with multileaf collimation, and 10 with bilateral arc rotation. Dosimetric analysis (DVHs) showed a reduction of 50% in volume of bladder or rectum receiving doses higher than 65 Gy. Acute side effects included dysuria, moderate difficulty in urinating, and nocturia in 25-39% of both SRT and CRT patients; loose stools or diarrhea in 5-12% of 3D CRT and 16-22% of SRT patients; moderate proctitis in 3% of 3D CRT and 12% of SRT patients (p = 0.01). Chemical disease-free survival (prostate-specific antigen < or =2 ng/ml) at 3 years was 90% with 3D CRT and 80% with SRT (p = 0.01). Average initial treatment reimbursements were $13,823 (3D CRT), $10,864 (SRT), and $12,250 (radical prostatectomy). Average total treatment reimbursement and projected cost of management of initial therapy failures per patients were $15,173, $16,264, and $16,405, respectively. CONCLUSIONS: Three-dimensional CRT irradiated less bladder and rectum volume than SRT; CRT initial reimbursement was 28% higher than SRT and 12% higher than radical prostatectomy. Because of projected better local tumor control, average total cost of treating a patient with 3D CRT or radical prostatectomy is equivalent to cost of SRT. Treatment morbidity was lower with 3D CRT. Our findings reflect an overall benefit with 3D CRT as a new promising technology in treatment of localized prostate cancer. Dose-escalation studies may enhance its efficacy and cost benefit.

Adenocarcinoma↗

The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy.

OBJECTIVE: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. MATERIALS & METHODS: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. RESULTS: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. CONCLUSION: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue.

Adolescent↗

Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy.

PURPOSE: To establish the rate of resolution of prostatic edema following transperineal interstitial permanent prostate brachytherapy, and to determine the results and impact of timing of the postimplant assessment on the dose-volume relationship. METHODS AND MATERIALS: A series of 19 consecutive patients with early-stage adenocarcinoma of the prostate receiving transperineal interstitial permanent prostate brachytherapy, were enrolled in this study. Twelve received 125I and seven received 103Pd. Postoperative assessment included a computed tomographic (CT) scan on postoperative days 1, 8, 30, 90, and 180. On each occasion, CT scans were performed on a GE helical unit at 3-mm abutting slices, 15-cm field of view. Prostate volumes were outlined on CT scans by a single clinician. Following digitization of the volumes and radioactive sources, volumes and dose-volume histograms were calculated. The prostate volume encompassed by the 80% and 100% reference isodose volumes was calculated. RESULTS: Preimplant transrectal ultrasound determined volumes varied from 17.5 to 38.6 cc (median 27.9 cc). Prostate volumes previously defined on 40 randomly selected postimplant CT scans were compared in a blinded fashion to a second CT-derived volume and ranged from -32% to +24%. The Pearson correlation coefficient for prostate CT volume reproducibility was 0.77 (p < 0.03). CT scan-determined volume performed on postoperative day 1 was an average of 41.4% greater than the volume determined by preimplant ultrasound. Significant decreases in average volume were seen during the first month postoperatively. Average volume decreased 14% from day 1 to day 8, 10% from day 8 to day 30, 3% from day 30 to day 90, and 2% thereafter. Coverage of the prostate volume by the 80% isodose volume increased from 85.6% on postoperative day 1 to 92.2% on postoperative day 180. The corresponding increase in the 100% reference dose coverage of the prostate volume ranged from 73.1% to 83.3% between postoperative days 1, and 180, respectively. CONCLUSIONS: Most of the prostatic edema induced by brachytherapy appears to resolve by postoperative day 30. Scans performed on postimplant day 30 appear to adequately describe the time-averaged dose coverage of the prostate. This suggests that waiting approximately 1 month to perform postimplant analysis gives the most accurate prostatic volume and, consequently, dosimetric description of the implant.

Adenocarcinoma↗

A dose-response study for I-125 prostate implants.

PURPOSE: No dose-response study has ever been performed for I-125 prostate implants using modern techniques of implant evaluation and modern treatment outcome end points. The amount of activity per volume implanted was increased over time based on review of postimplant dosimetry. This resulted in different delivered dose levels. This study explores the relationship between dose, biochemical failure, and biopsy results. MATERIALS AND METHODS: 134 patients with T1-T2 prostate cancer were implanted with I-125 radioactive seeds and followed from 12 to 74 months (median: 32) postimplant. No patient received external beam irradiation or hormonal therapy. All patients implanted with I-125 had Gleason scores < or =6. One month postimplant, a CT-based three-dimensional dosimetric evaluation was performed on all patients. Using TG43 guidelines, dose-volume histograms were calculated. The dose delivered to the gland was defined as the D90 (dose delivered to 90% of prostate tissue as defined by CT). The D90s ranged from 26.8 to 256.3 Gy (median: 140.8 Gy). Biochemical failure was defined as two consecutive rises in prostate specific antigen (PSA) or a nadir level above 1.0 ng/ml. Posttreatment prostate biopsies (six to eight core samples) were routinely performed at 2 years postimplant. RESULTS: Improvements in freedom from biochemical failure (FFBF) rates were seen with increasing D90 levels. The 4-year FFBF rates for patients with D90 values < 100 Gy, 100-119.9 Gy, 120-13.9 Gy, 140-159.9 Gy, and > or =160 Gy were 53, 82, 80, 95, and 89%, respectively (p = 0.02). Patients receiving a D90 < 140 Gy (65 patients) were similar with respect to presenting disease prognostic factors to those receiving a D90 > or =140 Gy (69 patients). Patients receiving a D90 < 140 Gy had a 4-year FFBF rate of 68% compared to a rate of 92% for those receiving a D90 > or =140 Gy (p = 0.02). Two-year posttreatment biopsies were negative in 70% (33 of 47) of patients with a D90 < 140 Gy compared to a rate of 83% (24 of 29) in patients with a D90 > or =140 Gy (p = 0.2). A multivariate analysis using dose, PSA, score, and stage revealed that dose was the most significant predictor of biochemical failure (p = 0.001). This dose response was more pronounced in patients presenting with PSA levels > 10 ng/ml. In these patients, the 4-year FFBF rates were 51 and 100% for the low and high dose groups, respectively (p = 0.009) and the negative biopsy rates were 64% (14 of 22) and 100% (8 of 8), respectively (p = 0.05). In patients with presenting PSA <10 ng/ml, the 4-year FFBF rates were 82 and 88% for the low and high dose groups, respectively (p = 0.29). CONCLUSION: A dose response was observed at a level of 140 Gy. Adequate I-125 implants should deliver a dose of 140-160 Gy using TG43 guidelines.

Brachytherapy↗

Temporal lobe (TL) damage following surgery and high-dose photon and proton irradiation in 96 patients affected by chordomas and chondrosarcomas of the base of the skull.

PURPOSE: To determine the temporal lobe (TL) damage rate in 96 patients treated with high-dose proton and photon irradiation for chordomas and chondrosarcomas of the base of the skull. METHODS AND MATERIALS: The records of 96 consecutive patients treated at Massachusetts General Hospital (MGH) and Harvard Cyclotron Laboratory (HCL) between June 1984 and 1993, for chordomas and chondrosarcomas of the base of the skull were reviewed. All the patients had undergone some degree of resection of the tumor prior to radiation therapy. Seventy-five patients were classified as "primary tumors" and 21 as recurrent or regrowing tumors after one or more surgical procedures. All the patients were randomized to receive 66.6 or 72 cobalt Gray equivalent (CGE) on a prospective dose-searching study by proton and photon irradiation (Radiation Therapy Oncology Group #85-26) with conventional fractionation (1.8 CGE/day, 5 fractions/week). All treatments were planned using the three-dimensional (3D) planning system developed at the Massachusetts General Hospital, and the dose was delivered using opposed lateral fields for the photon component and a noncoplanar isocentric technique for the proton component. Clinical symptoms of TL damage were classified into 4 grades. Computerized tomography (CT) and magnetic resonance imaging (MRI) scans were evaluated for white matter changes. Abnormalities associated with persistent or recurrent tumor were distinguished from radiation-induced changes. TLs were delineated on the original scans of the 10 patients with damage and those of a group of 33 patients with no clinical or MRI evidence of injury. Dose distributions were calculated and dose-volume histograms were obtained for these patients. RESULTS: Of the patients, 10 developed TL damage, with bilateral injury in 2 and unilateral injury in 8. The cumulative TL damage incidence at 2 and 5 years was 7.6 and 13.2%, respectively. The MRI areas suggestive of TL damage were always separated from the tumor bed. Symptoms were severe to moderate in 8 patients. Several baseline factors, tumor- or host-related, were analyzed to evaluate their predictivity for TL damage: age, gender, tumor site, histology, type of presentation, type and number of surgical procedures, primary tumor volume, prescribed dose, normal tissue involvement, and volume of TL receiving doses ranging between 10 and 50 CGE or more. Only gender, in a univariate analysis (log rank) was a significant predictor of damage (0.0155), with male patients being at significantly higher risk of TL injury. In a stepwise Cox regression that included gender as a variable, no other baseline variable improved the prediction of damage. CONCLUSIONS: The 2- and 5-year cumulative TL damage rates were 7.6 and 13.2%, respectively. Despite the different TL damage rates related to age, tumor volume, number of surgical procedures prior to radiation therapy, and prescribed doses to the tumor, only gender was a significant predictor of damage (p = 0.0155) using a univariate (log rank) test. Chordomas and chondrosarcomas of the base of the skull may represent an interesting model to evaluate the TL damage rates because of their extradural origin, displacing the white matter instead of infiltrating it as gliomas do, because of their longer local recurrence-free survival other than gliomas and other brain tumors and because of the high doses of irradiation delivered to the target volume to obtain local control.

Adolescent↗

Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients.

PURPOSE: To determine the relation between the incidence of radiation pneumonitis and the three-dimensional dose distribution in the lung. METHODS AND MATERIALS: In five institutions, the incidence of radiation pneumonitis was evaluated in 540 patients. The patients were divided into two groups: a Lung group, consisting of 399 patients with lung cancer and 1 esophagus cancer patient and a Lymph./Breast group with 78 patients treated for malignant lymphoma, 59 for breast cancer, and 3 for other tumor types. The dose per fraction varied between 1.0 and 2.7 Gy and the prescribed total dose between 20 and 92 Gy. Three-dimensional dose calculations were performed with tissue density inhomogeneity correction. The physical dose distribution was converted into the biologically equivalent dose distribution given in fractions of 2 Gy, the normalized total dose (NTD) distribution, by using the linear quadratic model with an alpha/beta ratio of 2.5 and 3.0 Gy. Dose-volume histograms (DVHs) were calculated considering both lungs as one organ and from these DVHs the mean (biological) lung dose, NTDmean, was obtained. Radiation pneumonitis was scored as a complication when the pneumonitis grade was grade 2 (steroids needed for medical treatment) or higher. For statistical analysis the conventional normal tissue complication probability (NTCP) model of Lyman (with n=1) was applied along with an institutional-dependent offset parameter to account for systematic differences in scoring patients at different institutions. RESULTS: The mean lung dose, NTDmean, ranged from 0 to 34 Gy and 73 of the 540 patients experienced pneumonitis, grade 2 or higher. In all centers, an increasing pneumonitis rate was observed with increasing NTDmean. The data were fitted to the Lyman model with NTD50=31.8 Gy and m=0.43, assuming that for all patients the same parameter values could be used. However, in the low dose range at an NTDmean between 4 and 16 Gy, the observed pneumonitis incidence in the Lung group (10%) was significantly (p=0.02) higher than in the Lymph./Breast group (1.4%). Moreover, between the Lung groups of different institutions, also significant (p=0.04) differences were present: for centers 2, 3, and 4, the pneumonitis incidence was about 13%, whereas for center 5 only 3%. Explicitly accounting for these differences by adding center-dependent offset values for the Lung group, improved the data fit significantly (p < 10(-5)) with NTD50=30.5+/-1.4 Gy and m=0.30+/-0.02 (+/-1 SE) for all patients, and an offset of 0-11% for the Lung group, depending on the center. CONCLUSIONS: The mean lung dose, NTDmean, is relatively easy to calculate, and is a useful predictor of the risk of radiation pneumonitis. The observed dose-effect relation between the NTDmean and the incidence of radiation pneumonitis, based on a large clinical data set, might be of value in dose-escalating studies for lung cancer. The validity of the obtained dose-effect relation will have to be tested in future studies, regarding the influence of confounding factors and dose distributions different from the ones in this study.

Dose-Response Relationship, Radiation↗

Patterns of failure following high-dose 3-D conformal radiotherapy for high-grade astrocytomas: a quantitative dosimetric study.

PURPOSE: To analyze the failure patterns for patients with high-grade astrocytomas treated with high-dose conformal radiotherapy (CRT) using a quantitative technique to calculate the dose received by the CT- or MR-defined recurrence volume and to assess whether the final target volume margin used in the present dose escalation study requires redefinition before further escalation. METHODS AND MATERIALS: Between 4/89 and 10/95, 71 patients with high-grade supratentorial astrocytomas were entered in a phase I/II dose escalation study using 3-D treatment planning and conformal radiotherapy. All patients were treated to either 70 or 80 Gy in conventional daily fractions of 1.8-2.0 Gy. The clinical and planning target volumes (CTV, PTV) consisted of successively smaller volumes with the final PTV defined as the enhancing lesion plus 0.5 cm margin. As of 10/95, 47 patients have CT or MR evidence of disease recurrence/progression. Of the 47 patients, 36 scans obtained at the time of recurrence were entered into the 3-D radiation therapy treatment planning system. After definition of the recurrent tumor volumes, the recurrence scan dataset was registered with the pretreatment CT dataset so that the actual dose received by the recurrent tumor volumes during treatment could be accurately calculated and then analyzed dosimetrically using dose-volume histograms. Recurrences were divided into several categories: 1) "central," in which 95% or more of the recurrent tumor volume (Vrecur) was within D95, the region treated to high dose (95% of the prescription dose); 2) "in-field," in which 80% or more of Vrecur was within the D95 isodose surface; 3) "marginal," when between 20 and 80% of Vrecur was inside the D95 surface; 4) "outside," in which less than 20% of Vrecur was inside the D95 surface. RESULTS: In 29 of 36 patients, a solitary lesion was seen on recurrence scans. Of the 29 solitary recurrences, 26 were central, 3 were marginal, and none were outside. Multiple recurrent lesions were seen in seven patients: three patients had multiple central and/or in-field lesions only, three patients had central and/or in-field lesions with additional small marginal or outside lesions, and one patent had 6 outside and one central lesion. Since total recurrence volume was used in the final analysis, 6 of the 7 patients with multiple recurrent lesions were classified into centra/in-field category. CONCLUSION: Analysis of the 36 evaluable patients has shown that 32 of 36 patients (89%) failed with central or in-field recurrences, 3/36 (8%) had a significant marginal component to the recurrence, whereas only 1/36 (3%) could be clearly labeled as failing mainly outside the high-dose region. Seven patients had multiple recurrences, but only 1 of 7 had large-volume recurrences outside the high-dose region. This study shows that the great majority of patient recurrences that occur after high-dose (70 or 80 Gy) conformal irradiation are centrally located: only 1/36 patients (with 7 recurrent lesions) had more than 50% of the recurrence volume outside the region previously treated to high dose. Further dose escalation to 90 Gy (and beyond) thus seems reasonable, based on the same target volume definition criteria

Adult↗

[Hyperfractionated reirradiation after salvage surgery in cervico-facial carcinoma. Result of a pilot study in 14 patients].

PURPOSE: Between November 1988 and May 1992, 14 patients were enrolled in a pilot study to evaluate the feasibility and results of hyperfractionated reirradiation for the treatment of head and neck recurrences or of second primary tumors developed in a previously irradiated volume. MATERIALS AND METHODS: All patients underwent a surgical resection for the treatment of their recurrence or second cancer. Reirradiation was proposed because of positive margins and/or lymph node metastasis with extra-capsular spread. The planned reirradiation dose was 60 Gy over 5 weeks, with two daily fractions of 1.2 Gy delivered 6-8 hours apart. RESULTS: Of the 14 patients, 10 received the reirradiation scheduled dose (ie, 60 Gy). All patients experienced an acute mucositis that never led to disruption of the treatment. Ten patients died 3 to 41 months after reirradiation (mean: 14 months), three were disease-free 48 to 71 months after reirradiation and one was alive with local progressive disease 74 months after reirradiation. The overall local control rate within the reirradiated volume was 43%. The 24- and 36-month overall survival rates were 50 and 35%, respectively. Overall, 13 late complications were noted: four were grade 1, seven were grade 2, and two were grade 3. Three patients still alive in September 1993 and whose initial files were available were enrolled in an additional study to assess from dose-volume histograms the cumulative doses delivered by the two irradiations. CONCLUSION: Despite poor local control, reirradiation using a hyperfractionation schedule with high dose level is feasible in terms of acute and late toxicity.

Adult↗

Proton beams in radiation therapy.

The rationale for study of proton radiation therapy is that, for some anatomic sites and tumors, the treatment volume is smaller; i.e., there is less irradiation of nontarget tissue while the target is included in three dimensions at each treatment session. As a result, the dose to the target can be raised. The consequence is that the tumor control probability improves and the frequency and severity of treatment-related morbidity decrease. These results come about from the physical fact that the proton range in tissue is finite; in comparison, absorption of photons is an exponential function and, hence, some dose is received for the full-beam path through the body. Accordingly, the dose deep to the target for proton treatments can be zero for each beam path. This situation provides a virtually certain means of improving the treatment outcome for selected categories of patients. Experience to date with proton radiation therapy has been quite limited. As of June 1991, the total number of proton radiation-treated patients was 11,763 from the various centers. Of that number, approximately 46% and 32% have been treated for small benign intracranial lesions (principally pituitary adenomas and arteriovenous malformations) and for tumors of the eye, respectively. Thus, only some 2500 patients have been treated for all other tumor types. The results from three centers and approximately 2800 patients with uveal melanoma are that the local control rate was 96% (for failures in-field, marginal, and in other parts of the eye). The local control results for chondrosarcomas and chordomas of the skull base are 91% and 65%, respectively. These percentages compare with some 35% achieved with conventional treatment. Experience with arteriovenous malformations indicates that control of bleeding and disappearance of the lesion are comparable to those achieved by other procedures. The developments from the proton therapy programs have contributed greatly to radiation treatment planning, e.g., the first three-dimensional treatment planning system put into regular clinical use (uveal melanoma), beam's eye view, digital-reconstructed radiograph, dose-volume histograms, and definitions of the uncertainty in dose around any defined point. The potential for clinical gains is high. In May 1991, the Proton Radiation Oncology Group was formed to design, supervise, and coordinate clinical trials and to assist in data analysis. The efficacy of proton radiation therapy will be compared with that of photon therapy of the very highest technology.

Arteriovenous Malformations↗

Alternating conformal neutron and photon irradiation for locally advanced adenocarcinoma of the prostate.

The substantial local failure rate for patients with locally advanced carcinoma of the prostate (LACaP) following photon irradiation, the association of local failure with a poor prognosis, and the promising results of mixed neutron/photon (40%/60%) radiotherapy supplied the rationale for this study. The purpose of this study was to evaluate the combined advantages of mixed neutron/photon (75%/25%) irradiation, 3D treatment planning, as well as fully conformal beam shaping capabilities in reducing the morbidity associated with neutron irradiation. The first 35 patients treated with this technique are the basis for this analysis. After CT stimulation and treatment planning, the normal tissue and target structures were entered into the 3D planning system. The neutron dose was delivered in 15 fractions at 1.0 Gy/fraction (NGy) to the prostate and seminal vesicles (PSV) and 0.6 NGy/fraction to the pelvic lymph nodes (LN). The photon dose was given in 10 fractions of 1.8 Gy each to both the PSV and LN volumes. Neutron and photon dose-volume histograms (DVHs) were generated in each patient for the prostate, seminal vesicles, lymph nodes, bladder, and rectum. The adequacy of the neutron and photon components of the treatment were compared with respect to target volume and normal tissue irradiation. Based on the DVH analysis, the prostate and seminal vesicles received the prescribed dose with both neutrons (99% +/- 2%) and photons (99% +/- 2%). There was no significant difference in the dose to the bladder and rectum for both the neutrons and photons. The acute treatment related reactions have been mild, with only one grade III bladder reaction. The 3D conformal technology utilized in this study has been shown to allow for the delivery of neutron irradiation with no increase in dose to the adjacent normal tissues compared with that achieved with conformal photon treatment. Further follow-up will reveal whether the dosimetric advantage demonstrated by this technique translates into an improved therapeutic ratio.

Adenocarcinoma↗

Results of re-irradiation of primary intracranial neoplasms with three-dimensional conformal therapy.

We evaluated the potential of three-dimensional conformal therapy for re-irradiation of selected intracranial neoplasms and reviewed the retreatment of 20 patients at the University of Michigan between May 1988 and August 1991. All patients had previously undergone a full course of external beam radiotherapy (RT) to a median dose of 5,940 cGy (range 5,100-6,500 cGy), including five whole brain treatments. All recurrences were unsuitable for brachytherapy or radiosurgery. Various histologies were retreated, including 14 high-grade gliomas. Median time to re-irradiation was 38 months (range 9 months to 19 years, 6 months). RT was delivered with complex plans designed using fully integrated computed tomography/magnetic resonance imaging (CT/ MRI) tumor volume information, and regions of previous parenchymal treatment were avoided if possible. Composite (initial+retreatment) dose-volume histograms (DVH) of dose to nontarget brain allowed comparison of alternative plans to select beam orientations which minimized normal brain irradiation. Mean target dose of re-irradiation was 3,600 cGy (range 3,060-5,940 cGy). Total cumulative dose ranged from 8,060 to 11,940 cGy. Median survival was 9 months, and 1-year actuarial survival was 26%. After retreatment, 8 of 12 patients (67%) had steroid dose decrement and neurologic improvement at 4-48 months (median duration 14 months). Radiographic regression or stabilization of disease was noted in 11 of 16 patients (68%). Re-irradiation with highly conformal three-dimensional planning provides frequent clinical improvement with acceptable morbidity and should be considered in selected patients with recurrent intracranial neoplasms.

Actuarial Analysis↗

3-D dose-volume compensation using nonlinear least-squares regression technique.

A method for external beam dose-volume optimization is presented. The Gauss-Marquardt nonlinear least-squares regression technique is applied to compensator design and determination. The dose distribution (uniform or otherwise) desired throughout a volume is specified. Compensators optimized to produce the necessary variation of beam intensity across the surface of each beam are simultaneously determined for all the beams. Solutions for homogeneous dose, homogeneous target dose, and restricted dose to exterior target volume structures, and inhomogeneous target dose cases are presented. Dependence of the results on the number of parameters as well as the role of degree of desirability weighting is explained and illustrated via examples. Discussion of the significance and limitations of this optimization method is also presented.

Humans↗

Dose-volume histogram computations for small intracranial volumes.

A sampling formalism is presented to accurately compute the absolute volumes and integral dose-volume histograms of small volumes treated in stereotactic radiosurgery. The presence of small volumes and sharp dose gradients places special constraints on the computational formalism and the accuracy required to compute the dose-volume relationships. We use a spatially nonuniform random sampling method to allow an efficient and accurate computation of the dose-volume histograms for an arbitrary number of volumes. The computation of absolute volume vs dose allows intercomparison of dose delivered to target and dose-critical volumes and allows a quantitative trade-off analysis often critical to an optimal treatment of the lesion.

Algorithms↗

Dose-volume distributions: a new approach to dose-volume histograms in three-dimensional treatment planning.

A new approach to calculating and displaying dose-volume relationships in 3D radiation therapy is presented. We have developed a concept of a dose-volume distribution (DVD) and its corresponding differential dose-volume distribution (DDVD), based on organization of the data in the volume rather than in the dose domain. The new concepts make full use of the information that can be obtained from the dose calculation points and the sampling pattern and are designed to overcome shortcomings of the classical concepts of dose-volume histograms (DVH) and differential dose-volume histograms (DDVH). The new concepts can be applied to any number of dose calculation points, but they are especially advantageous when a small number of points is used. DVDs are particularly well suited to pseudo- and quasi-random sampling of dose distributions. We have developed an error analysis for DVDs and DDVDs in the case of pseudorandom sampling. We also describe an adaptive technique for minimizing the amount of data needed for purposes of display.

Biophysical Phenomena↗

Dose-surface histograms as treatment planning tool for prostate conformal therapy.

Dose-surface histograms are studied and compared with dose-volume histograms, as an evaluation tool for prostate treatment planning. For thin walled hollow organs, such as the rectum and bladder, the surface area irradiated is a more appropriate measure of the biological effect than the full volume. It is also more accurate and efficient to define the surface for a hollow structure and compute the surface area histograms. Application of the dose-surface histograms provide new insights into prostate treatment planning. A simple idealized geometry model demonstrates that the percentage surface area intersected by the geometric beam edge differs from the percentage volume intersected. For a group of prostate patients, it is shown that the dose-surface histograms yield substantially different results from the dose-volume histograms in ranking four-, six-, and, eight-field treatment plans and in calculating the fraction of the rectum irradiated to high dose. The difference in terms of surface area between these plans in the high-dose region is usually less than that in terms of the volume, and a reverse of plan ranking order can consequently occur. The percentage of organ surface irradiated to high dose is typically greater than the percentage volume by 5% to 10%. The use of the dose-surface histograms in analysis of organ motion and/or patient setup uncertainty, and analysis of rectal complications, is also discussed.

Biophysical Phenomena↗

Reporting and analyzing dose distributions: a concept of equivalent uniform dose.

Modern treatment planning systems for three-dimensional treatment planning provide three-dimensionally accurate dose distributions for each individual patient. These data open up new possibilities for more precise reporting and analysis of doses actually delivered to irradiated organs and volumes of interest. A new method of summarizing and reporting inhomogeneous dose distributions is reported here. The concept of equivalent uniform dose (EUD) assumes that any two dose distributions are equivalent if they cause the same radiobiological effect. In this paper the EUD concept for tumors is presented, for which the probability of local control is assumed to be determined by the expected number of surviving clonogens, according to Poisson statistics. The EUD can be calculated directly from the dose calculation points or, from the corresponding dose-volume distributions (histograms). The fraction of clonogens surviving a dose of 2 Gy (SF2) is chosen to be the primary operational parameter characterizing radiosensitivity of clonogens. The application of the EUD concept is demonstrated on a clinical dataset. The causes of flattening of the observed dose-response curves become apparent since the EUD concept reveals the finer structure of the analyzed group of patients in respect to the irradiated volumes and doses actually received. Extensions of the basic EUD concept to include nonuniform density of clonogens, dose per fraction effects, repopulation of clonogens, and inhomogeneity of patient population are discussed and compared with the basic formula.

Cell Division↗

A gradient inverse planning algorithm with dose-volume constraints.

An inverse planning algorithm for determining the intensity-modulated beams that will most closely generate a desired dose distribution is presented. The algorithm is three-dimensional and does not explicitly depend on beam energies and modalities. It allows a single prescription dose or a window of acceptable doses to be specified for the target, with additional constraints to account for under- or over-dosing. For the protection of organs at risk, it provides maximum-dose and dose-volume constraints. The latter apply to the entire volume of the organ exposed to the corresponding dose levels. Several levels of each type of constraint, with varying penalty weights, may be specified for each organ. The objective function that serves as the measure of the goodness of the solution is of the least-squares type and is minimized using conjugate gradient methods. Typical clinical cases involving 40,000 points and 4000 rays to be determined require about 10 min of CPU time on a DEC AlphaStation. Results are presented for two clinical sites, prostate and lung. The optimization algorithm yielded plans that featured higher target dose homogeneity, compared with the human planner's plan, while selectively sparing more of the normal organs at the desired dose regions.

Aged↗

[The dose-volume factor in radiotherapy. Significance of the focal or tumor volume for the evaluation of radiotherapeutic effect].

The absorbed energy dose, in dependence on the irradiated tissue volume or tumor volume (dose-volume-relations) has great significance for the valuation of radiation injuries and of the prognosis of the disease. The present paper includes an analysis, formal demonstrations and interpretation of these relations. Clinical observations and radiobiological experiments in literature were the basis of the present investigation. The assessment is kept simple, the models derived from it interprete well the clinical findings. Through these models, radiobiological findings and clinical experimental principles are connected. This results in a clear conception of the future development of irradiation planning, and the application technique of radiation. The range of validity of the cited models includes the treated volumes usual in radiotherapy. An extrapolation to the cellulary area or to the whole body may only be made with great reservations.

Humans↗