PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROENCEPHALOGRAPHY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Electroencephalography and brain damage in preterm infants.

Electroencephalography (EEG) is a sensitive method for detection of brain injury in preterm infants. Although the acute and chronic EEG changes are mainly non-specific regarding type of damage, they correlate with later neurological and cognitive function. In infants developing brain white matter damage, acute EEG findings include depression of background activity and presence of epileptic seizure activity. The chronic EEG changes associated with white matter injury and abnormal neurological development include delayed maturation, and presence of abundant Rolandic sharp waves. Cognitive limitations in preterm infants have been associated with changes in various sleep measures in EEG's recorded at full term. Continuous EEG-monitoring during neonatal intensive care shows that cerebral electrical activity during this vulnerable period can be affected by several extracerebral factors, e.g. cerebral blood flow, acidosis and some commonly used medications. For diagnosis of brain damage in preterm infants with neurophysiological methods, a combination of early continuous EEG monitoring during the initial intensive care period and full EEG, performed at later stages, is probably optimal.

Brain Injuries↗

Lack of influence of mild hypothermia on amplitude integrated-electroencephalography in neonates receiving extracorporeal membrane oxygenation.

OBJECTIVE: To observe amplitude integrated electroencephalography (aEEG) in neonates receiving ECMO and to determine whether mild hypothermia influenced the aEEG recording. METHODS: Twenty-six consecutive neonates enrolled in a pilot study of mild hypothermia during ECMO were studied. The first group (N=6) was maintained at 37 degrees C throughout the study period. Subsequent groups were cooled to 36 degrees C (N=4), 35 degrees C (N=5), and finally 34 degrees C (N=6) respectively for 24 h and the final group (N=5) to 34 degrees C for 48 h before being rewarmed to 37 degrees C. The aEEG was recorded continuously during the first 5 days of ECMO. The aEEG was classified as normal, moderately or severely suppressed and examined for the occurrence of seizures. To assess the effect of temperature, the aEEG was compared over 12 h during the final 6 h of cooling and during the first 6 h once infants were rewarmed. RESULTS: No change in aEEG amplitude was noted over the temperature range studied. Of the 26 traces obtained, 16 (62%) were normal throughout, 6 (23%) were intermittently moderately abnormal and 1 (14%) was severely abnormal. Three (11%) traces had periods of frequent seizure activity and these were not associated with clinical manifestations in two neonates. In one infant who suffered a cerebral haemorrhage, the aEEG became abnormal before cranial ultrasound abnormalities were apparent. CONCLUSIONS: Continuous cerebral monitoring with aEEG is feasible during ECMO and may add information to clinical examination. Mild hypothermia to 34 degrees C for up to 48 h does not influence the aEEG suggesting that cerebral monitoring with aEEG is possible during mild hypothermia.

Body Temperature↗

Changes in amplitude-integrated electroencephalography in neonates treated with extracorporeal membrane oxygenation: a pilot study.

Neonates (n = 20) treated with extracorporeal membrane oxygenation were evaluated with serial amplitude-integrated electroencephalography (aEEG). There was no acute change in aEEG during extracorporeal membrane oxygenation cannulation, nor were there lateralizing effects. An abnormal aEEG predicted death or moderate to severe intracranial neuropathology with sensitivity = 1.0, specificity = 0.75, positive predictive value = 0.86, and negative predictive value = 1.0.

Brain Infarction↗

Conversion from mild cognitive impairment to Alzheimer's disease is predicted by sources and coherence of brain electroencephalography rhythms.

Objective. Can quantitative electroencephalography (EEG) predict the conversion from mild cognitive impairment (MCI) to Alzheimer's disease (AD)? Methods. Sixty-nine subjects fulfilling criteria for MCI were enrolled; cortical connectivity (spectral coherence) and (low resolution brain electromagnetic tomography) sources of EEG rhythms (delta=2-4 Hz; theta=4-8 Hz; alpha 1=8-10.5 Hz; alpha 2=10.5-13 Hz: beta 1=13-20 Hz; beta 2=20-30 Hz; and gamma=30-40) were evaluated at baseline (time of MCI diagnosis) and follow up (about 14 months later). At follow-up, 45 subjects were still MCI (MCI Stable) and 24 subjects were converted to AD (MCI Converted). Results. At baseline, fronto-parietal midline coherence as well as delta (temporal), theta (parietal, occipital and temporal), and alpha 1 (central, parietal, occipital, temporal, limbic) sources were stronger in MCI Converted than stable subjects (P<0.05). Cox regression modeling showed low midline coherence and weak temporal source associated with 10% annual rate AD conversion, while this rate increased up to 40% and 60% when strong temporal delta source and high midline gamma coherence were observed respectively. Interpretation. Low-cost and diffuse computerized EEG techniques are able to statistically predict MCI to AD conversion.

Aged↗

Electroencephalography in neonatal seizures: comparison of a reduced and a full 10/20 montage.

This study compares a reduced electrode montage (9 electrodes) with the full 10/20 electrode montage for the ability to detect and characterize neonatal seizures and background electroencephalographic (EEG) characteristics, utilizing new digital technology allowing "remontage" of previously acquired records. A total of 151 neonatal EEG records were retrospectively and blindly analyzed by two readers. Records were first analyzed for seizure number, topography, duration, and characteristics of EEG background using the reduced montage, before reanalysis with the full montage. One hundred eighty-seven seizures were identified in 31 ictal recordings using the full montage. Using the reduced montage, 166 seizures were identified in 30 records. The sensitivity and specificity of the reduced montage for detecting electrographic seizures was 96.8% and 100% respectively. In only one patient's record, the single seizure was missed altogether. For grading background abnormalities, the sensitivity and specificity of reduced montage was 87% and 80%. Although there are inherent weaknesses in reduced montages with respect to both underestimation and overestimation of seizure number, a nine-electrode reduced montage can be a sensitive tool for identification of neonatal seizures and assessment of background characteristics of neonatal electroencephalography.

Brain Mapping↗

New perspectives in pharmaco-electroencephalography.

Recent research emphasizes that majority of brain disorders and psychiatric problems are accompanied by disruption in the temporal structure of brain activity. From this perspective, disruption is viewed as a disorder of the metastable balance between large-scale integration and independent processing in the brain, in favor of either independent or hyper-ordered processing. This paper proposes that the future of psychopharmacology lies in its ability to design the psychotropic drugs which can restore the normal temporal structure and metastable structure of brain activity. Quantitative electroencephalography (QEEG) is one of the key complex technologies utilized in psychopharmacology for this purpose. However, conventional approaches for EEG analysis used in clinical practice are not suitable for studying temporal structure of brain activity. To overcome this limitation, and in order to reveal dynamic and temporal characteristics of brain activity, the advanced analysis of EEG micro-structure should be used.

Animals↗

Effects of alcohol on spontaneous neuronal oscillations: a combined magnetoencephalography and electroencephalography study.

Electroencephalography (EEG) and magnetoencephalography (MEG) can detect different aspects of alcohol effects on auditory processing measured with event-related potentials and magnetic fields. The present study aimed to detect alcohol-induced changes in spontaneous neuronal oscillations with combined EEG and MEG techniques. The effects of alcohol on spontaneous neuronal rhythms were studied in 12 healthy subjects after 0.8 g/kg alcohol or juice in a double-blind, placebo-controlled, cross-over design using simultaneous high-resolution MEG and EEG in eyes-open and eyes-closed conditions. The data were analyzed with a power spectral density analysis. MEG recording showed that alcohol significantly increased the relative power of alpha rhythm (8-10 Hz) and reduced the relative power of beta activity (17-25 Hz) in both left and right hemispheres, but only in the eyes-closed condition. These effects did not depend on gender. No analogous statistically significant changes were observed in EEG rhythms. However, the power of alpha and beta rhythms was positively correlated in MEG and EEG recordings, indicating that MEG and EEG reflect similar processes. A distinct sensitivity of MEG and EEG to the sources of cortical oscillations, a better signal-to-noise ratio of MEG, as well as strong spatial blurring of potentials in EEG are most likely the reasons for the observed differences in the effects of alcohol on spontaneous oscillations as detected with two methods.

Adult↗

Unusual features in eyelid myoclonia with absences: a patient with mild mental retardation and background slowing on electroencephalography.

"Eyelid myoclonia with and without absences" has been incorporated into the new ILAE diagnostic scheme as a type of epileptic seizure with etiologic, therapeutic, and prognostic implications. Eyelid myoclonia with absences (EMA) is characterized by eyelid myoclonia and absences provoked mainly by eye closure and photosensivity. EMA can be a part of idiopathic, symptomatic, or probably symptomatic epileptic syndromes. EMA is the defining seizure symptom that differentiates the idiopathic reflex epileptic syndrome Jeavons syndrome from eyelid myoclonia with absences. Jeavons syndrome is characterized by unique clinical and electroencephalographic features and often genetic clustering. EMA is easily diagnosed by clinical manifestations and properly conducted electroencephalography. However, it is often misdiagnosed as tics or other types of epileptic seizures and syndromes, particularly in patients with mental retardation, behavioral disturbances, and atypical electroencephalographic findings. We describe a 19-year-old woman with EMA who remained undiagnosed for many years. She was mildly mentally retarded and her electroencephalogram showed slow background activity, which are unusual findings in Jeavons syndrome.

Adult↗

Simultaneous electroencephalography and functional magnetic resonance imaging applied to epilepsy.

Among the recent advances in neuroimaging and clinical neurophysiology, simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI), that is SEM, stands apart as a challenging integration of techniques with great potential to provide unique information. The benefit of this integration is the utilization of each technique's strengths: the high temporal resolution and sensitivity to epileptic abnormalities of EEG and the high spatial resolution and noninvasive localization of cerebral metabolic change of fMRI. With SEM, electroencephalographic events that occur during fMRI may be identified and subsequently mapped with high resolution according to the hemodynamic changes that accompany them. Reaching the point of technically reliable SEM has required solutions to the many safety and electrical noise problems inherent to this technique. Recording an electroencephalogram during MRI requires special, MRI-compatible EEG equipment and a means to identify the low-amplitude electroencephalographic signal within an electrically noisy environment. With the results obtained at several institutions, SEM is now at a point in its development where the understanding of its validity as an indicator of the epileptic irritative and ictal-onset zones can be expanded. Because of its integration of both electrophysiologic and metabolic information, SEM also may be used to gain a greater understanding of cerebral physiology, in general, and fundamental aspects of epilepsy, in particular.

Brain↗

"Gating" of human short-latency somatosensory evoked cortical responses during execution of movement. A high resolution electroencephalography study.

The present study aimed at investigating gating of median nerve somatosensory evoked cortical responses (SECRs), estimated during executed continuous complex ipsilateral and contralateral sequential finger movements. SECRs were modeled with an advanced high resolution electroencephalography technology that dramatically improved spatial details of the scalp recorded somatosensory evoked potentials. Integration with magnetic resonance brain images allowed us to localize different SECRs within cortical areas. The working hypothesis was that the gating effects were time varying and could differently influence SECRs. Maximum statistically significant (p<0. 01) time-varying gating (magnitude reduction) of the short-latency SECRs modeled in the contralateral primary motor and somatosensory and supplementary motor areas was computed during the executed ipsilateral movement. The gating effects were stronger on the modeled SECRs peaking 30-45 ms (N30-P30, N32, P45-N45) than 20-26 ms (P20-N20, P22, N26) post-stimulus. Furthermore, the modeled SECRs peaking 30 ms post-stimulus (N30-P30) were significantly increased in magnitude during the executed contralateral movement. These results may delineate a distributed cortical sensorimotor system responsible for the gating effects on SECRs. This system would be able to modulate activity of SECR generators, based on the integration of afferent somatosensory inputs from the stimulated nerve with outputs related to the movement execution.

Adult↗

Pharmacodynamics of temazepam in primary insomnia: assessment of the value of quantitative electroencephalography and saccadic eye movements in predicting improvement of sleep.

BACKGROUND AND OBJECTIVE: Quantitative electroencephalographic parameters and saccadic eye movements are frequently used as pharmacodynamic measures of benzodiazepine effect. We investigated the relationship between these measures and the hypnotic effect. METHODS: The correlation between the pharmacodynamic measures and sleep quality was determined in 21 patients with primary insomnia. The pharmacokinetic-pharmacodynamic relationships were characterized after administration of 20 mg oral temazepam. The hypnotic effect was determined on the basis of polysomnographic sleep recordings and a subjective sleep evaluation questionnaire. Correlations between pharmacodynamic measures and the improvement of sleep were investigated. RESULTS: The pharmacokinetic-pharmacodynamic relationships for the parameters derived from electroencephalography and saccadic eye movements showed considerable interindividual variability. Administration of temazepam led to a significant improvement in the objective parameters sleep period efficiency, wake time after sleep onset, and sleep efficiency and in the subjective assessment of sleep quality. No significant correlations were observed between the pharmacokinetic-pharmacodynamic-derived parameters and the improvement in objective or subjective sleep parameters. CONCLUSION: In subjects with primary insomnia the administration of 20 mg oral temazepam results in changes in both the pharmacodynamic measures and in quality of sleep. No individual correlations between the pharmacodynamic measures and quality of sleep were observed. We concluded that the investigated pharmacodynamic measures are of value in the first assessment of clinical efficacy and for the selection of the dose(s) to be investigated in subsequent trials that aim at showing clinical efficacy. However, the conclusive quantification of clinical efficacy should be performed only on the basis of the clinical end point itself.

Adult↗

Quantitative electroencephalography: a method to assess cerebral injury after hypothermic circulatory arrest.

Although hypothermic circulatory arrest and low-flow cardiopulmonary bypass are routinely used for surgical correction of congenital cardiac anomalies, use of long durations of arrest, often required for more complex repairs, raises serious concerns about cerebral safety. Searching for an intraoperative assessment that can reliably predict cerebral injury, we have found an excellent correlation between changes in quantitative electroencephalography intraoperatively and immediately postoperatively after prolonged hypothermic arrest, and neurologic and behavioral evidence of cerebral injury. After epidural placement of four recording electroencephalographic electrodes and baseline neurologic/behavioral and electroencephalographic assessment, 32 puppies were randomly assigned to one of four groups: hypothermic controls in which cooling to 18 degrees C was followed immediately by rewarming, 30 minutes of hypothermic circulatory arrest at 18 degrees C, 90 minutes of arrest at 18 degrees C, and 90 minutes of low-flow cardiopulmonary bypass at 25 ml/kg per minute at 18 degrees C. An electroencephalogram was recorded at baseline, after cooling, during rewarming, and at 2, 4, and 8 hours after the start of rewarming, as well as before the operation and 1 week after the operation. Postoperative neurologic and behavioral outcome was assessed 24 hours after cardiopulmonary bypass and daily for 1 week by means of a graded scale in which 0 is normal and 12 and 13 indicate severe neurologic injury (coma and death). Thirty animals survived the experimental protocol: two animals in the 90-minute hypothermic arrest group died before neurologic evaluation could be completed, and the remainder exhibited various degrees of neurologic and behavioral impairment, more severe on day 1 than on day 6. No animal in the remaining groups had a significant neurologic deficit. Quantitative electroencephalographic analysis shows marked differences between the 90-minute arrest group and the controls in the percent electroencephalographic silence during rewarming and at 2 hours, and in the percent recovery of baseline power at 2, 4, and 8 hours. At 2 hours after the start of rewarming, a correlation between electroencephalographic amplitude and neurologic/behavioral score on day 1 was carried out, which predicts with great certainty (p < 0.00001) that if electroencephalographic power at this time is less than 500 microV2, overt neurologic injury will subsequently become apparent. In addition, a significant shift from higher to lower frequency in the day 6 postoperative electroencephalogram compared with baseline occurs only in the 90-minute arrest group.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Electroencephalography and bladder innervation.

Combined electroencephalography and cystometry provides the only method presently available to analyze central micturition reflex disturbances. When these techniques are used in sleep cystometry they provide a rational method to evaluate nocturnal enuresis.

Cerebral Cortex↗

A simple algorithm for a digital three-pole Butterworth filter of arbitrary cut-off frequency: application to digital electroencephalography.

Algorithms for low-pass and high-pass three-pole recursive Butterworth filters of a given cut-off frequency have been developed. A band-pass filter can be implemented by sequential application of algorithms for low- and high-pass filters. The algorithms correspond to infinite impulse-response filters that have been designed by applying the bilinear transformation to the transfer functions of the corresponding analog filters, resulting in a recursive digital filter with seven real coefficients. Expressions for filter coefficients as a function of the cut-off frequency and the sampling period are derived. Filter performance is evaluated and discussed. As in the case of their analog counterparts, their transfer function shows marked flattening over the pass band and gradually higher attenuation can be seen at frequencies above or below the cut-off frequency, with a slope of around 60 dB/decade. There is a 3 dB attenuation at the cut-off frequency and a gradual increase in phase shift over one decade above or below the cut-off frequency. Low-pass filters show a maximum overshoot of 8% and high-pass filters show a maximum downwards overshoot of approximately 35%. The filter is mildly under-damped, with a damping factor of 0.5. On an IBM 300GL personal computer at 600 MH with 128 MB RAM, filtering time with MATLAB 5.2 running under Windows 98 is of the order of 50 ms for 60000 samples. This will be adequate for on-line electroencephalography (EEG) applications. The simplicity of the algorithm to calculate filter coefficients for an arbitrary cut-off frequency can be useful to modern EEG laboratories and software designers for electrophysiological applications.

Algorithms↗

Quantitative electroencephalography in mild cognitive impairment: longitudinal changes and possible prediction of Alzheimer's disease.

The present study evaluated the clinical course of patients with mild cognitive impairment (MCI), the pattern of electroencephalography (EEG) changes following cognitive deterioration, as well as the potential of neurophysiological measures in predicting dementia. Twenty-seven subjects with MCI were followed for a mean follow up period of 21 months. Fourteen subjects (52%) progressed (P MCI) to clinically manifest Alzheimer's disease (AD), and 13 (48%) remained stable (S MCI). The two MCI subgroups did not differ in baseline EEG measures between each other and the healthy controls (n = 16), but had significantly lower theta relative power at left temporal, temporo-occipital, centro-parietal, and right temporo-occipital derivation when compared to the reference AD group (n = 15). The P MCI baseline alpha band temporo-parietal coherence, alpha relative power values at left temporal and temporo-occipital derivations, theta relative power values at frontal derivations, and the mean frequency at centro-parietal and temporo-occipital derivations overlapped with those for AD and control groups. After the follow-up, the P MCI patients had significantly higher theta relative power and lower beta relative power and mean frequency at the temporal and temporo-occipital derivations. A logistic regression model of baseline EEG values adjusted for baseline Mini-Mental Test Examination showed that the important predictors were alpha and theta relative power and mean frequency from left temporo-occipital derivation (T5-O1), which classified 85% of MCI subjects correctly.

Adult↗

Simultaneous electroencephalography and functional magnetic resonance imaging of primary and secondary somatosensory cortex in humans after electrical stimulation.

Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) measurements were performed in six healthy subjects to determine the representation of stimulation of the right thumb in somatosensory cortex. In all subjects EEG-based dipole locations could be determined in primary (S1) and secondary (S2) somatosensory cortex. The stimulus-induced blood oxygenation level dependent response of the fMRI showed deviations of 23.5 mm (standard deviation, SD = 6.9) for S1 and 15.7 mm (SD = 3.5) for S2 cortex. fMRI constrained dipole searches lead to higher residual variances. The data show that simultaneous EEG and fMRI measurements of somatosensory activity are feasible and yield reliable and valid results.

Adult↗

High frequency repetitive transcranial magnetic over the medial cerebellum induces a shift in the prefrontal electroencephalography gamma spectrum: a pilot study in humans.

In the present study the anatomical projections from the medial cerebellum to the prefrontal cortex (PFC) were investigated in healthy human subjects, using high frequency repetitive transcranial magnetic (rTMS) stimulation and electroencephalography (EEG). Medial cerebellar rTMS, compared to placebo induced a significant shift in anterior asymmetry, from left to right dominance in the fast (30-50 Hz) EEG spectrum, whereas occipital and lateral cerebellum stimulation did not show such an effect. Moreover elevations in mood and alertness were reported again after medial cerebellar stimulation only. Taken together, these data confirm and further specify the assumed cerebellar modulation of PFC activity and affect.

Adult↗

Differential outcomes from magneto- and electroencephalography for the analysis of human cognition.

Theoretical considerations show that magnetoencephalography (MEG) and electroencephalography (EEG) provide different information about ongoing human brain activity. The paper presents simultaneously measured MEG and EEG data showing that these measures may lead to different conclusions about cognitive models under investigation. This was demonstrated for amplitude results of the P300/N400 complex in a study of the secondary processing of lexical and non-verbal information in visual stimuli. As both methods provide different information about ongoing brain activity, their combined analysis is valuable. This seems particularly true for studies of higher order cognitive processing.

Analysis of Variance↗