PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts.

Small-intestine submucosa (SIS) is cell-free collagen, 100 mu thick, derived from the small intestine. It has been used as a vascular graft and has the highly desirable property of remodeling itself to become host tissue. To date there has been limited reporting on its preimplantation mechanical properties as a vascular graft. In this study, compliance, elastic modulus, and burst pressure have been measured on 5- and 8-mm SIS grafts. The compliance (percent of diameter increase for a pressure rise from 80 to 120 mmHg) was 4.6% av (range 2.9 to 8.6%) for the 5-mm grafts. For the 8-mm graft, the increase in diameter for the same pressure rise was 8.7% av (range 7.2 to 9.5%). The modulus of elasticity (E) increased exponentially with increasing pressure according to E = E(o)e(alphaP), where Eo is the zero-pressure modulus and alpha is the exponent that describes the rate of increase in E with pressure; the units for E, Eo, and P are g/cm2. The mean value for Eo was 4106 (g/cm2 range 1348-5601). The mean value for alpha was 0.0059 (range 0.0028-0.0125). At 100 mmHg, the mean value for E was 8.91 x 10(3) g/cm2 (range 1.02-8.80 x 10(3)). The mean burst pressure for 5.5-mm grafts was 3517 mm Hg (range 2069-4654). In terms of preimplant compliance, the small-diameter SIS graft is about (1/2) as compliant as the dog carotid artery, about four times more compliant than a typical vein graft, and more than an order of magnitude more compliant than synthetic vascular grafts.

Animals↗

Sensible human projects: haptic modeling and surgical simulation based on measurements of practical patients with MR elastography--measurement of elastic modulus.

To provide realistic surgical simulation, 3D visualization and haptic feedback are important. In the existing surgical simulators, the fidelity of the deformation and haptic feedback is limited because they are based on the subjective evaluation of the expert-user and not on an objective model-based evaluation. To obtain accurate elastic modulus of whole human tissues, we have started a new project called the Sensible Human Project (SHP). This paper deals with establishing the measurement of elastic modulus by the magnetic resonance elastography (MRE) technique, as a first step of the SHP Project.

Computer Simulation↗

Osteonal effects on elastic modulus and fatigue life in equine bone.

We hypothesized that recently formed, incompletely mineralized, and thus, relatively deformable osteons in the equine third metacarpus enhance in vitro load-controlled fatigue life in two ways. Macroscopically, there is a compliance effect, because reduced tissue elastic modulus diminishes the stress required to reach a given strain. Microscopically, there is a cement line effect, in which new osteons and their cement lines more effectively serve as barriers to crack propagation. We studied 18 4 x 10 x 100 mm beams from the medial, lateral, and dorsal cortices of metacarpal bones from 6 thoroughbred racehorses. Following load-controlled fatigue testing to fracture in 4 point bending, a transverse, 100 microm thick, basic fuchsin-stained cross-section was taken from the load-bearing region. The number and diameter of all intact (and thus recently formed/compliant) secondary osteons in a 3.8 x 3.8 mm region in the center of the section were determined. The associated area fraction and cement line length of intact osteons were calculated, and the relationships between these variables, elastic modulus (E), and the logarithm of fatigue life (logN(F)) were analyzed. As expected, logN(F) was negatively correlated with E, which was in turn negatively correlated with intact osteon area fraction and density. (LogN(F))/E increased in proportion to intact osteon density and nonlinearly with cement line density (mm/mm(2)). These results support the hypothesis that remodeling extends load-controlled fatigue life both through the creation of osteonal barriers to microdamage propagation and modulus reduction.

Animals↗

Biaxial anisotropy of dog carotid artery: estimation of circumferential elastic modulus.

Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to retracted vessel length. These studies were performed in systematically randomized order. At each length, the vessels were pressurized in steps up to 200 mmHg transmural pressure, or until the traction force fell to zero. Results showed that longitudinal extension markedly increased the longitudinal elastic modulus, but had only a slight effect on the circumferential modulus. At physiological pressures, the vessels were nearly isotropic at about 70% longitudinal extension, but were anisotropic at shorter lengths. Estimates of the anisotropic circumferential modulus by a number of simplified methods revealed that use of a 'pressure-elastic modulus' (Ep) underestimated the anisotropic modulus by 80%, but was extremely consistent. Therefore when suitably corrected, Ep could be used to reliably estimate the anisotropic modulus of carotid arteries over a wide range of pressures and vessel lengths.

Animals↗

The effects of interphase and bonding on the elastic modulus of bone: changes with age-related osteoporosis.

A simple shear lag model is developed to analyze the physics of the stress transfer between the organic and mineral constituents of bone tissue in the presence of an interphase and changes in bonding. The analytical model is developed assuming interactions between overlapped bone mineral platelets. The platelets are assumed to carry the axial stresses while the organic matrix transfers the stresses from one platelet to another by shear. A decrease in the interphase mechanical properties decreases the elastic modulus due to increased shear between the overlapped platelets. A decrease in bonding decreases the elastic modulus due to an increase in the axial stress transferred from the ends of the platelet. The implications of the changes in parameters on the age-related disorders of bone (osteoporois) are discussed. It is suggested that the aspect ratio and volume fraction of the mineral in the remaining bone tissue would increase due to a reduction in the density of the bone. The mechanical properties of the organic are hypothesized to increase due to a reduction in the density of bone leading to an increased tendency for damage within the organic.

Blood Platelets↗

Vertebral trabecular bone microscopic tissue elastic modulus and hardness do not change in ovariectomized rats.

Ovariectomized rats have been used extensively and have received substantial acceptance as animal models for postmenopausal osteoporosis. However, little is known about the microscopic tissue properties of rat vertebral bone, especially during osteoporosis caused by estrogen depletion. This study applied a new nanoindentation technique to quantify the microscopic mechanical properties of vertebral trabecular bone tissue in ovariectomized rats. Seventeen-week-old Sprague-Dawley rats underwent an ovariectomy. After death at 37 weeks, the fraction of the trabecular bone area of the lumbar vertebrae (L4) was measured with scanning electron microscopy and the elastic modulus and hardness were determined with the nanoindentation technique. The bone area fraction was reduced significantly after the ovariectomy. However, the elastic modulus and hardness did not change significantly at the microscopic level. The results indicate that estrogen-dependent osteoporosis in rats manifests in a loss of bone mass whereas the elastic and hardness properties of the surviving bone tissue remain relatively unchanged.

Animals↗

How to select the elastic modulus for cancellous bone in patient-specific continuum models of the spine.

Patient-specific finite element (FE) modelling is a promising technology that is expected to support clinical assessment of the spine in the near future. To allow rapid, robust and economic patient-specific modelling of the whole spine or of large spine segments, it is practicable to consider vertebral cancellous bone in the spine as a continuum material, but the elastic modulus of that continuum material must reflect the quality of the individual vertebral bone. A numerical parametric model of lattice trabecular architecture has been developed for determining the apparent elastic modulus of cancellous bone Ecb in vertebrae. The model inputs were apparent morphological parameters (trabecular thickness TbTh and trabecular separation TbSp) and the bone mineral density (BMD), which can all be measured in vivo, using the spatial resolution of current clinical quantitative computed tomography (QCT) commercial whole-body scanners. The model predicted that Ecb values between 30 and 110 MPa represent normal morphology and BMD of human spinal cancellous bone. The present Ecb to TbTh, TbSp and BMD relationships pave the way for automatic generation of patient-specific continuum FE spine models that consider the individual's osteoporotic or other degenerative condition of cancellous bone.

Bone Density↗

Determination of the red blood cell apparent membrane elastic modulus from viscometric measurements.

Rhelogical measurements on a dilute suspension of red blood cells (RBCs) are interpreted by means of a microheological model that relates the shear evolution of the apparent viscosity to the intrinsic properties of the suspended particles. It is then possible to quantify the average deformability of a RBC population in terms of a mean value of the membrane shear elastic modulus, Es. Dilute suspensions of erthrocytes exhibit shear-thinning behavior with a constant high shear viscosity. This behavior is identical to the one predicted for a suspension of spherical capsules where the same phenomena of deformation and orientation prevail. A comparison between theoretical and experimental curves yields a mean value of Es, assuming all other cell properties--internal viscosity, geometry--to be otherwise equal. In Dextran, the values of Es for normal RBCs are found to be of order 3.10(-6) N/m. For erythrocytes hardened by heat exposure for 15 minutes at 48 degrees C, the increase in Es reaches 45 percent. This procedure of shear elastic modulus determination is easy to perform and seems to give a good discrimination between normal and altered erythrocytes.

Biomechanical Phenomena↗

Elastic modulus and strength of emu cortical bone.

The emu (Dromaius novaehollandiae) shows potential as a unique animal model for replicating the femoral head collapse process seen in end-stage human osteonecrosis. Since the collapse phenomenon (and interventions to prevent it) involve mechanical processes, it is important to elucidate the similarities and differences of emus versus humans in terms of hip joint biomechanics. A first step for comparison is the intrinsic mechanical properties of the respective bone tissues, as reflected in cortical bone flexural stiffness and strength. In four-point bending, emu cortical bone was found to have an elastic modulus of 13.1 GPa. Its yield stress was determined to be 113 MPa and the ultimate strength was 146 MPa. Emu cortical bone's elastic modulus was similar to that of other avian species, and falls approximately 25% below that of the human (17.3 GPa).

Animals↗

Glycoprotein IIb/IIIa blockade inhibits platelet-mediated force development and reduces gel elastic modulus.

The effects of GPIIb/IIIa blockade on clot retraction were studied utilizing an instrument which directly measures force produced by platelets. GPIIb/IIIa disruption by calcium chelation, and GPIIb/IIIa blockade by peptides and anti-GPIIb/IIIa antibodies were investigated. One mM EDTA suppressed ADP-induced platelet aggregation by 72% and reduced force developed at 1200 s by 33%. At 234 microM, the tetrapeptide Arg-Gly-Asp-Ser (RGDS) suppressed platelet aggregation by 74%, reduced force at 1200 s by 45% and reduced gel elastic modulus by 19%. At 10 microM, the peptide D-Arg-Gly-L-Asp-L-Try (D-RGDW) completely suppressed platelet aggregation, reduced force development by 38% and reduced gel elastic modulus by 29%. At 0.133 microM, monoclonal anti-GPIIIa antibody (AP-3) reduced force development by 74% and reduced gel modulus by 60%. Murine antiGPIIb/IIIa antibodies 10E5 and 7E3 markedly suppressed force development. At 0.133 microM, 10E5 reduced force by 89% and reduced gel modulus by 67%. At 0.053 microM, 7E3 completely stopped force development and reduced gel modulus by 46%. Platelet aggregation was blocked by 0.027 microM 7E3. Selective GPIIb blockade by antibodies did not affect force development. None of the agents studied altered fibrin structure as monitored by effects of fibrin mass/length ratios. Suppression of platelet aggregation occurred at inhibitor concentrations substantially lower than those required to suppress force development. Complete suppression of platelet aggregation did not assure inhibition of clot retraction probably due to profound platelet activation by thrombin.(ABSTRACT TRUNCATED AT 250 WORDS)

Amino Acid Sequence↗

Mechanical properties of the dentinoenamel junction: AFM studies of nanohardness, elastic modulus, and fracture.

The dentinoenamel junction (DEJ) is a complex and poorly defined structure that unites the brittle overlying enamel with the dentin that forms the bulk of the tooth. In addition, this structure appears to confer excellent toughness and crack deflecting properties to the tooth, and has drawn considerable interest as a biomimetic model of a structure uniting dissimilar materials. This work sought to characterize the nanomechanical properties in the region of the DEJ using modified AFM based nanoindentation to determine nanohardness and elastic modulus. Lines of indentations traversing the DEJ were made at 1-2 microm intervals from the dentin to enamel along three directions on polished sagittal sections from three third molars. Nanohardness and elastic modulus rose steadily across the DEJ from bulk dentin to enamel. DEJ width was estimated by local polynomial regression fits for each sample and location of the mechanical property curves for the data gradient from enamel to dentin, and gave a mean value of 11.8 microm, which did not vary significantly with intratooth location or among teeth. Nanoindentation was also used to initiate cracks in the DEJ region. In agreement with prior work, it was difficult to initiate cracks that traversed the DEJ, or to produce cracks in the dentin. The fracture toughness values for enamel of 0.6-0.9 MPa . m(1/2) were in good agreement with recent microindentation fracture results. Our results suggest that the DEJ displays a gradient in structure and that nanoindenation methods show promise for further understanding its structure and function.

Algorithms↗

Elastic modulus in young diabetic patients (ultrasound measurements of pulse wave velocity).

Aim of this study is to confirm the validity of non-invasive evaluation with Doppler C.W. in the study of arterial diseases and in the identification of pre-clinical arterial lesions. We studied twenty-eight children suffering from diabetes mellitus, and dependent on insulin and a control group composed of twenty-eight healthy persons. All subjects were studied using the methodology of the transit time for the determination of the elastic modulus of the lower limb arterial wall and results were analysed according to a statistical method. Although the groups were small, an increase in pulse wave velocity was noted in diabetic children and a significative correlation was found between the elastic modulus and duration of diabetes.

Adolescent↗

The elastic modulus of central and perilimbal bovine cornea.

Data on the elastic properties of corneal tissue are needed to define the parameters involved in a model for radial keratotomy. Using bovine corneal tissue, we measured stress-strain relationships of tissue at different locations in the cornea. From this data we calculated Young's modulus of elasticity of five specimens at peripheral and central corneal locations. Increasing levels of stress produced increased resistance to stretch, a property typical of soft biologic materials such as cornea. Linear regression analysis of the data showed that the elastic modulus of the peripheral tissue was greater than that of central tissue at all values of applied stress. These linear relationships were statistically different, using an analysis of covariance, indicating that peripheral corneal tissue is stiffer than central corneal tissue. This information supports the suggestion that a peripheral circular ligament of corneal tissue exists and helps to maintain the curvature of the cornea. It is the disruption of this ligament that is believed to cause some of the change in corneal curvature when radial keratotomy is done.

Animals↗

The effect of uremia on platelet contractile force, clot elastic modulus and bleeding time in hemodialysis patients.

INTRODUCTION: Uremic bleeding frequently occurs in dialysis patients. Although its mechanism is not well characterized, acquired platelet dysfunction has been implicated in its pathogenesis. Skin bleeding time has been used to characterize platelet dysfunction in this population. However, the bleeding time is prone to error. The goal of this study was to compare the bleeding time to the novel platelet function parameters platelet contractile force and clot elastic modulus as well as platelet aggregation studies in controls and patients receiving maintenance hemodialysis. MATERIALS AND METHODS: Forty-five subjects completed this study (25 controls, 20 dialysis). All subjects had the Ivy skin bleeding time procedure performed, as well as the collection of whole blood samples for the determination of platelet contractile force, clot elastic modulus, % von Willebrand Factor antigen, and platelet aggregation studies. Pearson's correlation determined the relationships between skin bleeding time and platelet function and clot structure parameters and markers of renal dysfunction. RESULTS: Bleeding time was significantly prolonged in the dialysis group relative to controls. The platelet function parameters were not significantly different between groups. There was a significant relationship between bleeding time and creatinine concentration, however, no relationship existed between bleeding time and platelet function parameters. CONCLUSIONS: Skin bleeding time poorly correlates with measurements of platelet function. There were no significant differences noted in platelet function between the groups despite the prolongations in bleeding time in the dialysis group. These data may suggest that the bleeding time reflects perturbations in platelet adhesion or secretion, and not aggregation. Further study is needed to characterize platelet function in dialysis patients.

Adult↗

Ultrasonic measurement of the elastic modulus of the common carotid artery. The Atherosclerosis Risk in Communities (ARIC) Study.

BACKGROUND AND PURPOSE: The Atherosclerosis Risk in Communities Study is a prospective investigation of the etiology and natural history of atherosclerosis and the etiology of clinical disease in four US communities. METHODS: Noninvasive ultrasonic methods were used to determine mean wall thickness (WT), radius (R), and circumferential arterial strain (CAS) in the left common carotid artery of 3,321 white male and female study participants between the ages of 45 and 64 years. The mean and standard deviation of Young's elastic modulus (Y) in 5-year age groups were determined for each sex by combining the ultrasonic data with concurrent noninvasive measurements of pulse pressure (PP) in the right brachial artery using the equation Y = (R/WT) x (PP/CAS). RESULTS: Significant (p = 0.0001) age group differences in Y were observed in both sexes, with the mean value increasing from 701 kPa in women and 771 kPa in men in the 45-49-year-old age group to 965 and 983 kPa, respectively, in the 60-64-year-old age group. Significant (p = 0.0001) age group differences were also observed for WT, the WT/R ratio, PP, CAS, and the PP/CAS ratio in both sexes. A sex difference in Y was detected (male greater than female, p = 0.0006) only in the 45-49-year-old age group. Significant (p less than 0.0001) sex differences were found, with men having a greater lumen diameter calculated as 2 x (R - WT), a greater WT, and a greater 2R in all age groups. The WT/R ratio did not differ in both sexes in all age groups. CONCLUSIONS: Knowledge of the arterial wall elastic modulus and the parameters required for its determination can provide important insight into structural changes occurring within the arterial wall with age and sex, and possibly with the onset of very early arterial disease.

Aging↗

The effect of elastic modulus of the backing material on the fatigue notch factor and stress.

In cemented acetabular cup design it is acknowledged that bone resorption and fatigue fracture of cement may cause the most common problems after total hip replacement. Previous studies have optimized the shape of metal backing (MB) shell used in cemented acetabular components in order to minimize the fatigue notch factor (Kf) in cement, whilst at the same time maximizing Kf in bone at the central part of acetabulum to prevent stress shielding and subsequent bone resorption [1]. The optimal shape was found to be thin at the edges and thick at the dome. The present study describes the effect of changing the elastic modulus of the backing material on Kf and stresses as predicted by the initial shape of the backing shell of (3 mm) thick, and the optimized backing shape of non-uniform thickness in order to find the optimal material for the backing shell. It is recommended to use a backing shell material with elastic modulus equals 70 GPa (which can be readily attained using a fiber reinforced polymer composite). It is shown that such a material will decrease the fatigue notch factor and the stresses in cement at cup edges, at the same time it will increase the stresses and the fatigue notch factor in bone at the central part of acetabulum. Thereby, reducing the possibility of fatigue fracture of cement, whilst at the same time decreasing the stress shielding effect and the resulting bone resorption. The effect of lower bone resorption and lower probability of fatigue fracture of the cement will also reduce the incidence of loosening and premature revision operations.

Aged↗

Single beat evaluation of circumferential aortic elastin elastic modulus in conscious dogs. Potential application in non-invasive measurements.

A description of the arterial wall elastic properties comprehends both collagen and elastin, clearly shown in a biphasic stress-strain relationship. From chronically instrumented conscious dogs, aortic pressure-diameter curves can be obtained in a single beat, which is impossible to perform in human beings. In control conditions, the collagen fibers are almost not distended and the resistance to stretch is mainly supported by the elastin fibers. Therefore, the mechanical properties of the aorta are almost purely elastic in the basal beat to beat conditions. In this study we propose and test five indexes, which include as variables: systolic, diastolic and mean arterial pressure and diameter; besides, arterial compliance and pressure-strain elastic modulus as suggested to evaluate the elastic behaviour of the elastic fibers. This data can be easily obtained by non-invasive methods, such as Doppler-ultrasound techniques and auscultative esphygmomanometrical measurements, while the indexes evaluated can be retrieved from a single beat evaluation. Of three measurements performed in chronically instrumented conscious dogs on different days, one of these indexes, the ME5 = [formula: see text] x Rdias proved to be an accurate and reliable parameter to evaluate the mechanical behaviour of arteries. This kind of parameter may be useful for research and evaluation of several diseases that markedly alter the arterial wall compliance.

Algorithms↗

On the measurement of human osteosarcoma cell elastic modulus using shear assay experiments.

This paper presents a method for determining the elastic modulus of human osteosarcoma (HOS) cells. The method involves a combination of shear assay experiments and finite element analysis. Following in-situ observations of cell deformation during shear assay experiments, a digital image correlation (DIC) technique was used to determine the local displacement and strain fields. Finite element analysis was then used to determine the Young's moduli of HOS cells. This involved a match of the maximum shear stresses estimated from the experimental shear assay measurements and those calculated from finite element simulations.

Biomechanical Phenomena↗