PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Food Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Application of ion-exchange cartridge clean-up in food analysis. I. Simultaneous determination of thiabendazole and imazalil in citrus fruit and banana using high-performance liquid chromatography with ultraviolet detection.

A simple, rapid and reproducible analytical method for thiabendazole (TBZ) and imazalil (IMA) in citrus fruit and banana has been developed. The method involves the use of an ion-exchange cartridge for sample clean-up followed by ion-pair high-performance liquid chromatography with ultraviolet detection. The recoveries of TBZ and IMA from citrus fruits spiked at levels of 10 microgram/g and 5 microgram/g were in the range of 94-98% and 93-98% with coefficients of variation of 0.5-2.2% and 1.6-2.7%, respectively. The recoveries of TBZ and IMA from banana spiked at levels of 3 microgram/g and 2 microgram/g were 94% and 94% with coefficients of variation 1.1% and 4.9%, respectively. The detection limits for TBZ and IMA were 0.1 microgram/g in citrus fruit and 0.05 microgram in banana.

Anthelmintics↗

Application of ion-exchange cartridge clean-up in food analysis III. Determination of benzylpenicillin, phenoxymethyl-penicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in bovine liver and kidney by liquid chromatography with ultraviolet detection.

A multiresidue analytical method was developed for the simultaneous determination of benzylpenicillin (PCG), phenoxymethylpenicillin (PCV), oxacillin (MPIPC), cloxacillin (MCIPC), nafcillin (NFPC) and dicloxacillin (MDIPC) in bovine liver and kidney. The method involves the use of an ion-exchange cartridge for sample clean-up followed by ion-pair high-performance liquid chromatography with ultraviolet detection. The recoveries of PCG, PCV, MPIPC, MCIPC, NFPC and MDIPC from bovine liver spiked at levels of 0.5 mg/kg and 0.1 mg/kg were in the range of 73-91% and 83-96% with coefficients of variation of 1.4-4.2% and 3.4-8.7%, respectively. For bovine kidney spiked at levels of 0.5 mg/kg and 0.1 mg/kg, the recoveries of these compounds were 79-92% and 82-92% with RSDs of 1.8-5.9% and 2.7-7.8%, respectively. The detection limits for the six penicillins were 0.02-0.05 mg/kg in bovine liver and kidney.

Animals↗

Application of ion-exchange cartridge clean-up in food analysis. II. Determination of benzylpenicillin, phenoxymethylpenicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in meat using liquid chromatography with ultraviolet detection.

A multiresidue analytical method was developed for the simultaneous determination of benzylpenicillin (PCG), phenoxymethylpenicillin (PCV), oxacillin (MPIPC), cloxacillin (MCIPC), nafcillin (NFPC) and dicloxacillin (MDIPC) in meat. The method involves the use of an ion-exchange cartridge for sample clean-up followed by ion-pair high-performance liquid chromatography with ultraviolet detection. The recoveries of PCG, PCV, MPIPC, MCIPC, NFPC and MDIPC from pork muscle spiked at levels of 0.5, 0.1 and 0.05 mg/kg were in the range of 77-90, 73-95 and 80-93% with coefficients of variation of 0.5-1.7, 1.6-4.4 and 3.2-6.6%, respectively. For beef muscle spiked at levels of 0.5, 0.1 and 0.05 mg/kg, the recoveries of these compounds were 83-92, 71-86 and 77-90% with coefficients of variation of 1.7-4.4, 2.6-7.0 and 3.9-6.4%, respectively. The detection limits for each penicillin were 0.02 mg/kg in meat.

Animals↗

Optimised uncertainty in food analysis: application and comparison between four contrasting 'analyte-commodity' combinations.

The optimised uncertainty (OU) methodology is applied across a range of analyte-commodity combinations. The commodities and respective analytes under investigation were chosen to encompass a range of input factors: measurement costs (sampling and analytical), sampling uncertainties, analytical uncertainties and potential consequence costs which may be incurred as a result of misclassification. Two types of misclassification are identified-false compliance and false non-compliance. These terms can be used across a wide range of foodstuffs that have regulations requiring either minimum compositional requirements, maximum contaminant allowances or compositional specifications. The latter refers to foodstuffs with regulations that state an allowable tolerance around the compositional specification, i.e. the upper specification limit (USL) and the lower specification limit (LSL). The traditional OU methodology has been adapted so that it is applicable in these cases and has been successfully applied in practice. The Newton-Raphson method has been used to determine the optimal uncertainty value for the two case studies in which analyte concentration is assessed against a 'single threshold' regulatory requirement. This numerical method was shown to give a value of the optimal uncertainty that is practically identical to that given by the previously used method of visual inspection. The expectation of financial loss was reduced by an average of 65% over the four commodities by the application of the OU methodology, showing the benefit of the method.

Food Analysis↗

Applications of liquid chromatography-mass spectrometry interfacing systems in food analysis: pesticide, drug and toxic substance residues.

This paper reviews applications of different LC-MS techniques for the determination of xenobiotic substances in foods. Specific examples of contaminants discussed are pesticides, herbicides, insecticides and drugs; concerning toxic substances, mycotoxins, phycotoxins, cyanobacterial toxins, mutagenic and heterocyclic amines and beta-carbolines, arsenic, tin and inorganic halogen compounds, packaging materials and various epoxy resins are considered. Advantages and limitations are outlined for the different LC-MS interfacing systems (particle beam, thermospray, atmospheric pressure ionization with electrospray, ionspray and heated pneumatic nebulizer). The impact of developments in instrumental analysis on methodology and the limitations of the various LC-MS methods are discussed. Further, the coupling of LC with element-selective detection systems such as inductively coupled plasma mass spectrometry is discussed, with emphasis on speciation of trace toxic elements in foods.

Chromatography, Liquid↗

Multi-analyte optimisation of uncertainty in infant food analysis.

The Optimised Uncertainty (OU) methodology has been developed to optimise multi-analyte situations. It has then been applied to a retail survey of infant food for trace elements, classifying the food as compliant or non-compliant with the regulatory thresholds or specification limits that are appropriate for each element. The large-scale survey of infant foods was successfully adapted to allow the estimation of uncertainties, from both primary sampling and chemical analysis, for elemental concentrations in infant formula (milk) and wet meals. The analytes included in this investigation comprised both contaminants (Pb and Cd) and elements essential for child development (Zn and Cu). Optimisation of the measurement process for a 'single analyte' demonstrated the potential financial benefits of optimising future surveys for a false compliance scenario. Uncertainty estimates for the measurement of elemental concentrations in infant formula were dominated by uncertainty from the analytical method. Large potential savings (up to pounds 575,000 per batch) are predicted for both Pb and Zn by increasing the expenditure on chemical analysis to the optimal level. In comparison the uncertainty estimates for elemental concentration in wet meals showed a dominance of sampling as a source of uncertainty for Cd and Cu due to the increased heterogeneity. The feasibility of 'multi-analyte' optimisation is demonstrated for the case study of infant milk. Single analyte optimisation of the four analytes for a false compliance scenario indicated a decrease in expectations of financial loss of between 99% and 8%. An overall decrease in the total expectation of financial loss of 99% is indicated following multi-analyte optimisation.

Child, Preschool↗

[Fluorescence bacterioscopy, a direct method for bacteriological food analysis].

The present bacteriological method which is intended for the simultaneous direct detection of live and dead germs in foods, offers certain difficulties in differentiating between bacterial cells and food consituents of similar forms. Furthermore, gram-negative germs are not disclosed. To overcome these difficulties, the authors performed comparative model experiments with Gram's stain and the fluorescence method, including pure cultures and foods of animal and vegetable origin. Among the fluorochromes tested (primuline, auramine, acridine orange and acridine yellow), acridine yellow has proved to be specially suited and superior to Gram's stain. A method is described which is termed fluorescence bacterioscopy. Its advantages and disadvantages are discussed.

Acridines↗

Determination of mercury in seafood by flow injection-cold vapor atomic absorption spectrometry after microwave digestion: NMKL interlaboratory study. Nordic Committee on Food Analysis.

Ten laboratories participated in an interlaboratory method-performance (collaborative) study of a method for the determination of mercury in foods of marine origin by flow injection-cold vapor atomic absorption spectrometry after wet digestion using a microwave oven technique. The study was preceded by a training round of samples of known identity. The method was tested on a total of 7 seafood products: blue mussel (Mytilus edulis), cod muscle (Gadus morhua), crab (Cancer pagurus), scampi (Nephrops norwegicus), black scabbard fish (Aphnopus carbo), longnose velvet dogfish (Centroscymus crepidater), and Portuguese dogfish (Cenbroscymus coelolepis) with mercury concentrations of 0.14, 0.24, 0.35, 0.59,11.42, 4.2, and 13.2 microg/g, respectively. The materials were presented to the participants in the study as blind duplicates, and the participants were asked to perform single determinations on each sample. Repeatability relative standard deviations (RSDr) for mercury ranged from 2.4 to 14.0%. Reproducibility relative standard deviations (RSDR) ranged from 7.7 to 16.6%. HORRAT values for all samples were <1.0.

Animals↗

Evaluation of lateral-flow Clostridium botulinum neurotoxin detection kits for food analysis.

The suitability and sensitivity of two in vitro lateral-flow assays for detecting Clostridium botulinum neurotoxins (BoNTs) in an assortment of foods were evaluated. Toxin extraction and preparation methods for various liquid, solid, and high-fat-content foods were developed. The lateral-flow assays, one developed by the Naval Medical Research Center (Silver Spring, MD) and the other by Alexeter Technologies (Gaithersburg, MD), are based on the immunodetection of BoNT types A, B, and E. The assays were found to be rapid and easy to perform with minimum requirements for laboratory equipment or skills. They can readily detect 10 ng/ml of BoNT types A and B and 20 ng/ml of BoNT type E. Compared to other in vitro detection methods, these assays are less sensitive, and the assessment of a result is strictly qualitative. However, the assay was found to be simple to use and to require minimal training. The assays successfully detected BoNT types A, B, and E in a wide variety of foods, suggesting their potential usefulness as a preliminary screening system for triaging food samples with elevated BoNT levels in the event of a C. botulinum contamination event.

Animals↗

Application of ion-exchange cartridge clean-up in food analysis. VI. Determination of six penicillins in bovine tissues by liquid chromatography-electrospray ionization tandem mass spectrometry.

A multiresidue analytical method was developed for the quantification of benzylpenicillin (PCG), phenoxymethylpenicillin (PCV), oxacillin (MPIPC), cloxacillin (MCIPC), nafcillin (NFPC) and dicloxacillin (MDIPC) in bovine tissues using liquid chromatography- electrospray ionization tandem mass spectrometry (LC-ESI MS/MS) with a multiple reaction monitoring technique. Using the deuterated PCG and NFPC as internal standard was effective for improvement of repeatability and accuracy. We chose [M-H-141]- as a monitor ion of MRM analysis and [M-H]- as a precursor ion for each penicillin. Combination of an ion-exchange cartridge clean-up and ion-pair LC enable us to determine the residual penicillins using the standard curves made from standard solutions without the influence of sample matrix on the MS. The average recoveries of PCG, PCV, MPIPC, MCIPC, NFPC and MDIPC from bovine liver, kidney and muscle at the same concentrations as the tolerance levels of PCG (50 microg/kg) ranged from 77 to 101% with the coefficients of variation ranging from 0.7 to 4.2% (n = 5). The limits of quantification for the six penicillins were 2-10 microg/kg in bovine muscle, liver and kidney (S/N ratio >10).

Animals↗

Analysis of food oligosaccharides using MALDI-MS: quantification of fructooligosaccharides.

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful new technique that will have a great impact on food analysis. This study demonstrates the applicability of MALDI-MS performed directly on an aqueous food extract for qualitative and quantitative analysis of food oligosaccharides. 2', 4',6'-Trihydroxyacetophenone was found to be the best matrix for analysis of oligosaccharides in the foods examined. The relationship between laser strength, resolution, and the response factors of individual oligosaccharides using MALDI-MS was investigated. A MALDI-MS method for quantitative analysis of fructooligosaccharides with standard addition of a pure fructooligosaccharide was developed. High performance anion exchange chromatography with pulsed amperometric detection was compared to MALDI-MS for the analysis of fructooligosaccharides. The fructooligosaccharide analyses were performed on red onions, shallots, and elephant garlic.

Carbohydrate Conformation↗

MALDI-TOF MS analysis of food flavonol glycosides.

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a new technique that is having a great impact on food analysis. This study is the first to demonstrate the use of MALDI-TOF MS to identify flavonol glycosides in food samples. 2',4',6'-Trihydroxyacetophenone was chosen as the best matrix because it worked for crude sample extracts and ionized flavonol glycosides in both positive and negative MALDI-TOF MS modes. In the positive mode, multiple ion forms were observed for flavonol glycosides, including [M + H](+), [M + Na](+), [M + K](+), and [M - H + Na + K](+), with further fragmentation through loss of glycosidic residues. The negative mode for all flavonol glycosides resulted in [M - H](-) ion formation without detectable fragmentation. The multiple ions in the positive mode gave more information on individual flavonol glycoside structures than the negative mode. Flavonol glycosides showed similar intensities or responses in the positive mode, while kaempferol glycosides exhibited much less response than quercetin glycosides in negative mode.

Flavonoids↗

Application of immunoassay in the food industry.

Immunoassay techniques using the highly specific and sensitive nature of immunological reactions have been developed and applied in the food industry for detecting the naturally occurring constituents, antibiotics, pesticide residues, microorganisms, and fragments of microbial constituents related to food analysis, food production, food processing, and food safety. Both polyclonal and monoclonal antibodies are employed for the development of the various immunoassay systems, including enzyme-linked immunoassay (ELISA) and radioimmunoassay (RIA). Immunoassay techniques provide complementary and/or alternate approaches in reducing the use of costly, sophisticated equipment and analysis time, but still maintaining reliability and improved sensitivity. Immunoassay techniques in their most simple forms provide excellent screening tools to detect adulteration and contaminations qualitatively. The application of immunoassay techniques contributes tremendously to the quality control and safety of our food supply.

Animal Feed↗

The use of glass capillary columns for food and essential oil analysis.

Foods and essential oils represent complex mixtures whose components frequently embrace a wide range of functional groups and volatilities. The analyst concerned with these products may be interested in overall separation or "fingerprinting," in correlating the amount of individual compounds with specific flavor notes, in the detection and measurement of specific substances such as nitrosamines or pesticides, or in following the progress of a biochemical reaction. Analytical speed and the sensitivity of the method may also be important, as well as the ability of reactive compounds to survive the analysis. Toward all of these goals, glass capillary gas chromatography offers distinct advantages.

Chromatography, Gas↗

Biosensors for the analysis of food- and waterborne pathogens and their toxins.

Biosensors are devices which combine a biochemical recognition element with a physical transducer. There are various types of biosensors, including electrochemical, acoustical, and optical sensors. Biosensors are used for medical applications and for environmental testing. Although biosensors are not commonly used for food microbial analysis, they have great potential for the detection of microbial pathogens and their toxins in food. They enable fast or real-time detection, portability, and multipathogen detection for both field and laboratory analysis. Several applications have been developed for microbial analysis of food pathogens, including E. coli O157:H7, Staphylococcus aureus, Salmonella, and Listeria monocytogenes, as well as various microbial toxins such as staphylococcal enterotoxins and mycotoxins. Biosensors have several potential advantages over other methods of analysis, including sensitivity in the range of ng/mL for microbial toxins and <100 colony-forming units/mL for bacteria. Fast or real-time detection can provide almost immediate interactive information about the sample tested, enabling users to take corrective measures before consumption or further contamination can occur. Miniaturization of biosensors enables biosensor integration into various food production equipment and machinery. Potential uses of biosensors for food microbiology include online process microbial monitoring to provide real-time information in food production and analysis of microbial pathogens and their toxins in finished food. Biosensors can also be integrated into Hazard Analysis and Critical Control Point programs, enabling critical microbial analysis of the entire food manufacturing process. In this review, the main biosensor approaches, technologies, instrumentation, and applications for food microbial analysis are described.

Biosensing Techniques↗