PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HPLC”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

CEDIA sirolimus assay compared with HPLC-MS/MS and HPLC-UV in transplant recipient specimens.

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA SRL assay has the potential to improve this situation. The present communication has compared the CEDIA SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 microg/L and 20 microg/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 microg/L and 20 microg/L, respectively. The lower limit of quantification was found to be 3.0 microg/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA method showed a Deming regression line of CEDIA=1.20xHPLC-MS/MS-0.07 (r=0.934, SEE=.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Chromatography, High Pressure Liquid↗

High performance liquid chromatography (HPLC) of natural products. IV. The use of HPLC in biosynthetic studies of cephalosporin C in the cell-free system.

A new cepham metabolite has been isolated from the filtered broth of Cephalosporium acremonium by high performance liquid chromatography (HPLC) and identified as 7 beta-(5-D-amino-adipamido)-3 beta-hydroxy-3 alpha-methyl-cepham-4 alpha-carboxylic acid (I). Pure penicillin N was prepared using HPLC in the analytical mode. When I was added in place of penicillin N as substrate for the cell-free biosynthetic of cephalosporin, no formation of deacetoxycephalosporin C (II) was observed. A synthetic cepham derivative, 7 beta-(5-D-aminoadipamido)-3-exomethylene-cepham-4 alpha-carboxylic acid (III) was also tested in the cell-free system as a possible intermediate. The compound III was shown to be an inhibitor of the ring expansion enzyme that converts penicillin N to deacetoxycephalosporin C.

Acremonium↗

High performance liquid chromatographic (HPLC) measures of hydrophobicity as determined by means of new HPLC columns.

Two new commercially available reversed phase high performance liquid chromatographic (HPLC) columns were tested from the view point of their usefulness for determination of hydrophobicity by means of partition chromatography. One column comprised a specially prepared hydrocarbon-bonded silica stationary phase material. The other column was packed with a polybutadiene-coated alumina (PBCA) phase. As reference served a regular commercial octadecylsilica (ODS) column. A series of test solutes were pyrazine CH- and NH-acids--the compounds which are able to take part in specific as well as in nonspecific intermolecular interactions. Unique properties of the new hydrocarbonaceous column manifested themselves in regular linear relationships between logarithms of capacity factors and volume percent of methanol in aqueous eluent. The main advantage of the PBCA column is a possibility of performing chromatography at alkaline pH. Both new columns are superior to regular ODS columns in respect of providing reliable chromatographic measures of hydrophobicity. It was observed that hydrophobicity parameters determined in individual HPLC systems are not highly intercorrelated and hence can reflect different structural features of solutes.

Aluminum↗

[Serum monitoring of methotrexate (MTX) and 7-hydroxymethotrexate concentrations in patients treated with MTX using high-pressure liquid chromatography (HPLC) and comparison of serum MTX levels between HPLC method and fluorescence polarization immunoassay (FPIA)].

In order to measure simultaneously the serum levels of methotrexate (MTX) and its major metabolite, 7-hydroxymethotrexate (7-OH-MTX), in samples obtained from patients treated with MTX, we have investigated the reversed-phase high-pressure liquid chromatographic assay using ion-pairing reagents. The mobile phase consisted of 77.5% solution of 0.005M tetrabutylammonium and 22.5% acetonitrile. SEP-PAK C18 Cartridges were used for the precolumn. The detectable range of MTX and 7-OH-MTX were 0.02-0.03 and 1.0 mumol/l respectively. A significant positive correlation was observed (r = 0.983) between FPIA and HPLC methods. Serum MTX levels with FPIA were significantly (p less than 0.05) higher than those of HPLC method. The serum 7-OH-MTX levels at 24 hr and 48 hr were 4.857 +/- 1.383 (n = 10) and 1.835 +/- 0.286 (n = 6) mumol/l respectively with the dosage of 400 mg/m2. The serum 7-OH-MTX levels at 48 hr were 6.254 +/- 3.053 mumol/l (n = 5) with the dosage of 3,000 mg. The serum half lives of MTX and 7-OH-MTX were 8.05 +/- 1.03 (n = 4) and 14.8 +/- 1.35 (n = 6) hours respectively between 24 hr and 48 hr after administration. The T1/2 7-OH-MTX/MTX ratio was 1.8. Percent cross-reactivity of 7-OH-MTX with concentrations ranging from 1-10 mumol/l were 0.6-2.0% by FPIA. However, patients' serum levels of 7-OH-MTX were 15-85 times (n = 21) higher than those of MTX. MTX levels of containing both MTX and 7-OH-MTX (7-OH-MTX/MTX ratio was 50/1) were significantly higher than those of containing MTX alone by FPIA.

Adult↗

Asymmetric activation of chiral alkoxyzinc catalysts by chiral nitrogen activators for dialkylzinc addition to aldehydes: super high-throughput screening of combinatorial libraries of chiral ligands and activators by HPLC-CD/UV and HPLC-OR/RIU systems.

Asymmetric catalysts, prepared by chiral ligand exchange or chiral modification, can evolve further into highly activated catalysts through engineering with chiral activators. Two new methodologies for "super high-throughput screening" (SHTS) of chiral ligands and activators have been developed as a combination of HPLC-CD/UV (CD/ UV = circular dichroism/ultraviolet spectroscopy) or -OR/RIU (OR/RIU = optical rotation/refractive index unit) with a combinatorial chemistry (CC) factory. With these techniques, the % ee of the product is determined within minutes without separation of the enantiomeric products by using a nonchiral stationary phase. Therefore, those SHTS techniques combined with our 'asymmetric activation' concept can provide a powerful strategy for finding the best activated chiral catalyst.

Journal Article↗

Detection of isorhamnetin glycosides in extracts of apples (Malus domestica cv. "Brettacher") by HPLC-PDA and HPLC-APCI-MS/MS.

Extracts of apple fruits (Malus domestica cv. "Brettacher") were analysed by HPLC with photodiode array detection. An unknown peak was monitored displaying the same retention time as isorhamnetin 3-O-glucoside. Preliminary identification of the isorhamnetin aglycone was performed by comparison of UV spectral data of the unknown compound with a reference substance. Using atmospheric pressure chemical ionisation mass spectrometry in the negative ion mode, the presence of an isorhamnetin glycoside was supported by loss of 162 amu from the pseudomolecular ion (m/z 477). MS2 product ion analysis of the parent ion m/z 477 provided a fragmentation pattern identical to the reference. Collision-induced dissociation of the aglycone (m/z 315) in the MS3 product ion analysis allowed the differentiation of rhamnetin and isorhamnetin, and unambiguous assignment by comparison with standard compounds. A second isorhamnetin glycoside eluting prior to the glucoside was tentatively identified as isorhamnetin 3-O-galactoside. To the best of our knowledge, this is the first report of isorhamnetin glycosides in apple fruit extracts. Results are discussed with respect to chemotaxonomic relevance within the genera Malus and Pyrus, and especially in consideration of the control of the authenticity of apple products.

Atmospheric Pressure↗

Identification by HPLC-PAD-MS and quantification by HPLC-PAD of phenylethanoid glycosides of five Phlomis species.

The qualitative and quantitative determination of phenylethanoid glycosides in methanolic extracts of five species of the genus Phlomis (Lamiaceae) has been investigated using a new reversed-phase HPLC method combined with photodiode-array detection and electrospray/MS analysis. Forsythoside B, verbascoside, samioside, alyssonoside, isoverbascoside, leucosceptosides A and B and martynoside were detected. The quantification of the above constituents was performed using echinacoside as internal standard. Knowledge of the content of phenylethanoid glycosides contributes to the chemotaxonomy of the genus.

Chromatography, High Pressure Liquid↗

The development and validation of a high performance liquid chromatography (HPLC)/tandem mass spectrometry assay for fenticonazole in human plasma and comparison with an HPLC-UV method.

A method is described for the determination of fenticonazole in human female plasma. The method utilizes high performance liquid chromatography coupled to atmospheric pressure positive-ion chemical ionization triple quadrupole mass spectrometry. Multiple reaction monitoring is employed for selectivity and sensitivity which enables quantification over the range 0.5-20 ng mL-1 with acceptable precision and accuracy. A comparison is made with an existing HPLC-UV assay and the utility of the technology of combined liquid chromatography and tandem mass spectometry for subnanogram per mL assays is discussed.

Antifungal Agents↗

Squalene isolation by HPLC and quantitative comparison by HPLC and GLC.

A new procedure is described for isolating and measuring squalene in plasma and in several organs of the rat. The unsaponifiable material was fractionated by normal phase HPLC on a silica gel column using a mobile phase consisting of hexane/propanol-2/water. The eluate was monitored at 215 nm. The squalene in the hydrocarbon fraction thus collected was than quantified on an analytical column eluted with hexane. Squalene concentrations ranging from 3 to 200 micrograms per ml of plasma or per g of fresh tissue were accurately measured. The results obtained agree with those of the squalene assays carried out by gas chromatography on a packed or capillary column.

Animals↗

A validated HPLC assay for salmon calcitonin analysis. Comparison of HPLC and biological assay.

A high-performance liquid chromatographic (HPLC) method is described for the assay of salmon calcitonin. The method uses a 5-microns octadecasilyl silica column (100 x 4.6 mm) at 50 degrees C and an initial mobile phase (flow rate 1 ml min-1) comprising 35% of B (1 M tetramethylammonium hydroxide-water-acetonitrile, 8:392:600) and 65% of A (1 M tetramethylammonium hydroxide-water-acetonitrile, 20:880:100) with linear gradient elution over 21 min to a final mobile phase of 57% B; solutions A and B are adjusted to pH 2.5 with phosphoric acid. Detection was by UV spectrophotometry at 210 nm. The method has been shown to be selective, precise and rapid and, in a collaborative study to give excellent correlation with the results obtained by using the biological assay method of the European Pharmacopoeia. The method, which has been applied successfully to the assay of different batches of salmon calcitonin in bulk drug and in formulated products, is recommended for adoption as the pharmacopoeial assay method.

Amino Acid Sequence↗

NO-donors, part X [1] : investigations on the stability of pentaerythrityl tetranitrate (PETN) by HPLC-chemoluminescence-N-detection (CLND) versus UV-detection in HPLC.

HPLC in combination with chemoluminescence-N-detection (CLND) is very useful for the analysis of pentaerythrityl tetranitrate (PETN) and its possible biological and chemical degradation products pentaerythrityl trinitrate (PETriN), pentaerythrityl dinitrate (PEDiN) and pentaerythrityl mononitrate (PEMonoN). Quantification is more convenient and sensitivity of this method is about four times higher compared to UV-detection. The present study demonstrates that PETN is a chemically more stable compound in vitro than expected. No degradation was observed in aqueous buffers (37 degrees C, pH 5.6, 7.4), human plasma, and simulated intestinal or gastric fluid. On the other hand, the addition of increasing amounts of thioles (cysteine, thioglycolic acid) induced an increasing degradation of PETN.

Chromatography, High Pressure Liquid↗

Determination of phenolic compounds in fennel by HPLC and HPLC-MS using a monolithic reversed-phase column.

A reversed-phase high-performance liquid chromatography (HPLC) method for analyzing phenolic compounds in fennel (Foeniculum vulgare) has been developed. The use of a monolithic column with short dimensions in combination with optimized chromatographic conditions allows over 100 samples per day to be analyzed. Chromatographic parameters such as column temperature and injection volume, were found to be crucial in obtaining adequate selectivity and resolution, consequently allowing short run times. The method was validated for the major phenolic compounds present in fennel plant material: 3-O-caffeoylquinic acid (3-CQA), chlorogenic acid, 4-O-caffeoylquinic acid (4-CQA), eriocitrin, rutin, miquelianin, 1,3-O-dicaffeoylquinic acid (1,3-diCQA), 1,5-O-dicaffeoylquinic acid (1,5-diCQA), 1,4-O-dicaffeoylquinic acid (1,4-diCQA) and rosmarinic acid. The limits of detection (LOD) and the limits of quantitation (LOQ) ranged from 0.05 to 1.0 microg/mL and from 0.15 to 2.5 microg/mL, respectively. With some adaptation, the extraction procedure could be even less invasive, which is useful in screening work.

Chlorogenic Acid↗

Separation, identification, quantification, and method validation of anthocyanins in botanical supplement raw materials by HPLC and HPLC-MS.

A method has been established and validated for identification and quantification of individual, as well as total, anthocyanins by HPLC and LC/ES-MS in botanical raw materials used in the herbal supplement industry. The anthocyanins were separated and identified on the basis of their respective M(+) (cation) using LC/ES-MS. Separated anthocyanins were individually calculated against one commercially available anthocyanin external standard (cyanidin-3-glucoside chloride) and expressed as its equivalents. Amounts of each anthocyanin calculated as external standard equivalent were then multiplied by a molecular-weight correction factor to afford their specific quantities. Experimental procedures and use of a molecular-weight correction factors are substantiated and validated using Balaton tart cherry and elderberry as templates. Cyanidin-3-glucoside chloride has been widely used in the botanical industry to calculate total anthocyanins. In our studies on tart cherry and elderberry, its use as external standard followed by use of molecular-weight correction factors should provide relatively accurate results for total anthocyanins, because of the presence of cyanidin as their major anthocyanidin backbone. The method proposed here is simple and has a direct sample preparation procedure without any solid-phase extraction. It enables selection and use of commercially available anthocyanins as external standards for quantification of specific anthocyanins in the sample matrix irrespective of their commercial availability as analytical standards. It can be used as a template and applied for similar quantification in several anthocyanin-containing raw materials for routine quality control procedures, thus providing consistency in analytical testing of botanical raw materials used for manufacturing efficacious and true-to-the-label nutritional supplements.

Anthocyanins↗

An improved model for prediction of retention times of tryptic peptides in ion pair reversed-phase HPLC: its application to protein peptide mapping by off-line HPLC-MALDI MS.

The proposed model is based on the measurement of the retention times of 346 tryptic peptides in the 560- to 4,000-Da mass range, derived from a mixture of 17 protein digests. These peptides were measured in HPLC-MALDI MS runs, with peptide identities confirmed by MS/MS. The model relies on summation of the retention coefficients of the individual amino acids, as in previous approaches, but additional terms are introduced that depend on the retention coefficients for amino acids at the N-terminal of the peptide. In the 17-protein mixture, optimization of two sets of coefficients, along with additional compensation for peptide length and hydrophobicity, yielded a linear dependence of retention time on hydrophobicity, with an R2 value about 0.94. The predictive capability of the model was used to distinguish peptides with close m/z values and for detailed peptide mapping of selected proteins. Its applicability was tested on columns of different sizes, from nano- to narrow-bore, and for direct sample injection, or injection via a pre-column. It can be used for accurate prediction of retention times for tryptic peptides on reversed-phase (300-A pore size) columns of different sizes with a linear water-ACN gradient and with TFA as the ion-pairing modifier.

Amino Acid Sequence↗

Identification and quantification of metallothionein isoforms and superoxide dismutase in spiked liver extracts using HPLC-ESI-MS offline coupling and HPLC-ICP-MS online coupling.

A two-dimensional chromatographic method for the characterization of metallothionein isoforms (MT) and superoxide dismutase (SOD) in spiked liver extracts was developed for the optimization of extraction procedures from liver samples. Element-specific detection (ICP-MS) and molecule-specific detection (ESI-MS) were applied for maximum species information. A special focus was laid on the quantitative data evaluation (species stoichiometry, calibration with and without matrix, recovery), which is neglected in most MT/SOD publications with hyphenated techniques. Linearity, precision (residual standard deviation of calibration curves <10%), and detection limits (<0.6 mg L(-1) for MT isoforms and 13 mg L(-1) for SOD) prove the suitability of the method for quantification. An alternative quantification is proposed for the extension towards other lesser or even unknown trace element species, especially the native porcine MT and SOD.

Animals↗

Activity assay of His-tagged E. coli DNA photolyase by RP-HPLC and SE-HPLC.

Escherichia coli DNA photolyase was expressed as C-terminal 6x histidine-fused protein. Purification of His-tagged E. coli DNA photolyase was developed using immobilized metal affinity chromatography with Chelating Sepharose Fast Flow. By one-step affinity chromatography, approximate 4.6 mg DNA photolyase was obtained from 400 ml E. coli culture. The purified His-tagged enzyme was combined with two chromophors, FADH and MTHF. Using the oligonucleotide containing cyclobutane pyrimidine dimer as substrate, both reversed-phase high-performance liquid chromatography and size-exclusion high-performance liquid chromatography were developed to measure the enzyme activity. The enzyme was found to be able to repair the cyclobutane pyrimidine dimer with the turnover rate of 2.4 dimers/photolyase molecule/min.

Chromatography, High Pressure Liquid↗

Normal-phase HPLC and HPLC-MS studies of the metabolism of a cytosolic phospholipase A(2)alpha inhibitor with activated ketone group by rat liver microsomes.

Inhibition of cytosolic phospholipase A(2)alpha (cPLA(2)alpha) is assumed to provide a novel therapeutic approach for the treatment of many inflammatory diseases. 1-[3-(4-Octylphenoxy)-2-oxopropyl]indole-5-carboxylic acid (2) is a potent inhibitor of cPLA(2)alpha. An important part of the pharmacophore of 2 is its activated electrophilic ketone moiety. Since it is known that activated ketones may be metabolically unstable, the metabolism of 2 by rat liver microsomes was investigated. For quantification of the metabolites normal-phase HPLC/UV on a cyano column was used, because under reversed-phase conditions with aqueous solvents 2 was partly transformed into its hydrate resulting in chromatograms with splitted peaks. Under the conditions applied about 30% of 2 were metabolized. The main metabolite was the alcohol 4 as shown by LC/MS(n).

Alcohols↗

Optimization and validation of HPLC-UV-DAD and HPLC-APCI-MS methodologies for the determination of selected PAHs in water samples.

Polycyclic aromatic hydrocarbons (PAHs) are environmental contaminants resulting from emissions of a variety of sources including industrial combustion, discharge of fossil fuels, and residential heating. Because of their mutagenic and carcinogenic properties, the study of PAHs in environmental matrices is of great importance. In this work, the extraction of 9 out of the 16 PAH priority pollutants according to the U.S. Environmental Protection Agency is carried out through liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The determination of PAHs is made by high-performance liquid chromatography with diode-array detection and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. Between the extraction techniques used, LLE is revealed to be efficient in the extraction of the higher molecular weight PAHs, though SPE is adequate for the extraction of all PAHs. In the real water samples analyzed, no PAH is detected under the analysis conditions used.

Atmospheric Pressure↗