A phase I trial of alfimeprase for peripheral arterial thrombolysis.

PURPOSE: To evaluate the safety profile, pharmacokinetics, and thrombolytic activity of alfimeprase, a novel direct-acting thrombolytic agent, in patients with chronic peripheral arterial occlusion (PAO). MATERIALS AND METHODS: In this multicenter, open-label, single-dose, dose-escalation study, 20 patients with worsening symptoms of lower extremity ischemia within 6 months of enrollment were treated with alfimeprase in five escalating dose cohorts (0.025 mg/kg, 0.05 mg/kg, 0.1 mg/kg, 0.3 mg/kg, and 0.5 mg/kg) by means of intraarterial and sometimes intrathrombic pulsed infusion. The primary endpoint was safety assessed by adverse event rates. Additional safety assessments included vital sign monitoring, serum chemistry testing, hematologic testing, and coagulation testing for 28 days after the procedure, as well as alpha2-macroglobulin and antialfimeprase antibody testing for as long as 3 months after treatment. Pharmacokinetic parameters were evaluated with use of an assay that measures free and alpha2-macroglobulin-bound (ie, total) alfimeprase. RESULTS: No patient experienced a hemorrhagic adverse event. Mean plasminogen and fibrinogen concentrations were not substantially altered by treatment. Three transient treatment-related adverse events were reported in the same patient: one incidence each of increased blood fibrinogen level, skin rash, and headache. All three adverse events were graded as mild. The pharmacokinetic profile of alfimeprase suggested that the half-life for total alfimeprase ranges from 11 to 54 minutes (median, 25 min) in patients with PAO. The serum alpha2-macroglobulin concentrations decreased transiently in a dose response-like manner between 12 and 24 hours and returned to within normal limits approximately 14 days after alfimeprase exposure. CONCLUSIONS: Alfimeprase in doses as high as 0.5 mg/kg was generally well-tolerated in patients with chronic PAO. No bleeding complications were noted. The stable fibrinogen concentrations suggest that the activity of alfimeprase may be limited to the target thrombus. Alfimeprase holds the potential to achieve dissolution of thrombus with a diminished risk of hemorrhage.

Adult↗

[Total hematological analysis system as a screening test for hematological malignancy].

Measurement of complete blood cell count and white blood cell differentiation is an essential laboratory test and the most important screening test for hematological malignancy. Recently, several automated blood cell analyzers have been developed to improve accuracy and precision. When flag messages generated in the presence of morphological abnormalities of the samples are displayed, manual revision is necessary. In our laboratory, the manual revision rate has been 35-40%. Therefore blood cell analyzers are useful in screening for abnormalities as well as greatly reducing expensive and time-consuming manual differential procedures. In addition, automated blood cell analyzers can provide several types of useful information including the leukocyte distribution scattergram. However, most such information is not utilized in the clinical field. In the future, a total hematological analysis system will be constructed so that all information provided by automated blood cell analyzer and by manual methods are available.

Blood Cell Count↗

[Molecular diagnostic tests in hematologic diseases].

Molecular diagnostic tests are widely performed in managing hematologic malignancies such as leukemia and lymphoma. In this article, we review the present application and problems of the tests. Karyotyping is performed at diagnosis of all kinds of hematologic malignancies. This method needs dividing cells as samples and skilled experts. Fluorescence in situ hybridization(FISH) analysis using cells in interphase is performed, for example, to monitor the effect of interferon on chronic myelogenous leukemia patients. The weak point of this method is that approximately 2% of false-positive cells are inevitable. Southern blot method is used for clonal analysis in some disease, for example, adult T-cell leukemia/lymphoma. Polymerase chain reaction(PCR) method using genomic DNA is performed for limited types of diseases such as lymphoma with bcl-2/IgH fusion gene. Reverse transcription(RT)-PCR method can detect fusion gene transcripts with high sensitivity. This method is useful for detecting minimal residual diseases after chemotherapy or bone marrow transplantation. To perform quantitative analysis, real-time PCR or competitive PCR must be done. In the near future, new technology such as gene expression profiling analysis using DNA microarrays or spectral karyotyping(SKY) method will be used in clinical practice.

Blotting, Southern↗

Pulmonary hypertension in sickle cell disease.

BACKGROUND: Recurrent vaso-occlusive episodes lead to progressive end-organ damage in patients with sickle cell disease. We sought to determine the prevalence of pulmonary hypertension in adult patients with sickle cell disease and to identify factors associated with this life-threatening complication. METHODS: Sixty patients (> or =18 years of age; mean [+/- SD] age, 37 +/- 13 years) followed at a University Medical Center were evaluated. They were selected by a systematic sampling of patients presenting to the clinic for routine follow-up visits. All enrolled subjects underwent a clinical examination, Doppler echocardiography, pulmonary function tests, and hematologic tests during a single visit. Pulmonary hypertension was defined using an age- and body mass index-adjusted nomogram. RESULTS: The prevalence of pulmonary hypertension was 30% (18/60). Ten patients had mild pulmonary hypertension (up to 44 mm Hg), 5 had moderate pulmonary hypertension (45 to 74 mm Hg), and 2 had severe pulmonary hypertension (> or =75 mm Hg). In a logistic regression model, both lower fetal hemoglobin level and lower systolic blood pressure were associated with the presence of pulmonary hypertension. CONCLUSION: We found that the prevalence of pulmonary hypertension in adult patients with sickle cell disease was substantial, particularly in those with lower levels of fetal hemoglobin and lower systolic blood pressure.

Adult↗

[Problems on emergency laboratory tests for blood cell counts (BCC) and coagulation].

Emergency laboratory tests need to clarify sudden changes in disease conditions in inpatients and outpatients. Such tests are used for various purposes and at various times. In the department of Clinical Laboratory in Osaka City University Medical School Hospital, the emergency laboratory office was established and blood cell counts and coagulation tests are the hematological tests performed. Blood cell counts are performed throughout the day on weekdays and holidays, but coagulation tests are only performed from 9 am to 5 pm on weekday. Laboratory tests are requested using the ordering system with computer and laboratory results are shown on line. The number of emergency blood cell counts per year is approximately 23,539, accounting for about 20% of the number of routine blood cell counts each year, 14,561 (61.9%) on weekdays, 8,978 (38.1%) on holidays, 17,695 (75.2%) for inpatients and 5,844 (24.8%) for outpatients. The number of inpatients tested per year was 8,760 (49.5%) on holidays and 8,935 (50.5%) on weekdays. The number of outpatients tested per year was 5,626 (96.3%) on weekdays and 218 (3.7%) on holidays. Emergency laboratory tests will be more useful for large-scale hospitals in the future. The construction of an emergency laboratory system suitable for each hospital is important. Furthermore, the continuous improvement in emergency laboratory systems and greater advances in the quality of clinical laboratory test are necessary.

Blood Coagulation Tests↗

Investigation of statistical decision rules for sequential hematologic laboratory tests.

A statistical data processing program for identifying patients who are likely to have abnormalities on various hematologic laboratory tests is described. The prediction of abnormal levels of serum vitamin B12, serum folate, transferrin saturation, and reticulocyte counts is based on a statistical analysis of the patient's age, sex, and routine blood cell measurements. The program was developed using data from normal-value studies and data from patients who had these laboratory abnormalities. The sensitivity and specificity of the program were evaluated in a controlled prospective study of about 5,000 ambulatory adult patients. The program's predictions also were compared with the laboratory tests requested by the patients' attending physicians. The program was most sensitive for predicting low serum vitamin B12 (74%) and low transferrin saturation (78%). In the prospective evaluation, the predictive values varied from 11% for predicting low serum folate to 65% for predicting low transferrin saturation.

Adult↗

[Quality assurance of the molecular diagnostic tests in hematological malignancies].

Analyses of nucleic acid sequences in hematological malignancies are now essential in managing patients with hematological malignancies. Because of the impact of the test on decision-making in patient care, its accuracy is quite important. Detection of BCR-ABL mRNA by polymerase chain reaction, one of the most popular molecular diagnostic tests for hematological malignancies, has been used for diagnosis of Philadelphia-positive leukemias. Quality of the test must be assured in the process of diagnostic plan, sampling, measurement(nucleic acid isolation, amplification, detection), report and interpretation. Risk of false-positive results due to contamination of in vitro nucleic acid amplification reactions can be decreased through the use of protocols for contamination control. False-negative results may be caused by variability in BCR breakpoint, and loss or degradation of RNA due to inappropriate procedures as well as an insufficient detection sensitivity. Presence of inhibitors of amplification is also to be considered as a cause of false-negative results. Thus, quality control techniques such as internal standards are mandatory to ensure efficient amplification as well as RNA extraction. For the precise evaluation of minimal residual diseases, accurate and sensitive quantitative analyses are required. For quality assurance of assays in the present status of no commercially available kits, it is particularly important to monitor the clinical validation of the results by correlating them with the patient's status to prove clinically relevant. Staffs need to be trained to be familiar with both molecular pathogenesis and technology so that they can provide informative test results with a high quality.

Genes, abl↗

[Hematological-biochemical tests in patient with migraine].

Migraine is periodical disorder which is characterized by recurrent headache seizures different in intensity, frequency and duration. Amylases L-1,4 glycol: gluckanohidrolises, (EC.3.2.1.1) are enzymes from hydrolase's group which dissolve starch meaning glycogen. Activity of amylases in serum grows: at acute pancreatitis, at carcinoma of pancreas, heavy necroses of pancreas. Total number of examinees was 92 out of which 45 were male (48.9 %) and 47 female or 51.1 %. Average age of the examines was 42.9. Neuroticism scale which was tested by Cornell scale was 55,03. Out of the total number of examinees 30 or 32,6 were non-smokers while 62 or 67,4 % smoked regularly. The aim of this work is to perform hematological-biochemical test of blood in patients with migraine. In the beginning of this research it was planned for all the patients to have hematological blood test done (sedimentation of erythrocytes, trombocytes, complete blood test and differential blood test) and biochemical blood test (hepatogram, transamynase, amylase, Lactal dehydrogenase, Alkalic phosphatase, ferrum in serum, Glucose, Cholesterol, Calcium and Phosphorus in serum. After reviewing the received values of hematological and biochemical tests, all values were within the borders of normal values. Amylases had higher values at 49 or 53,3 % of patients, and 43 or 46,7 % of patients had normal values of amylases. Normal values of amylases are to 220 U/l measured by I.F.C. at 37 degrees C. Medium value in tested group is 219.09. It means that every second examinee had increased values of amylase in blood; there is no statistics difference of amylase value between sexes.

Adolescent↗

Hematologic screening tests in patients with operative prostatic disease.

One hundred sixty-five patients with operative prostatic disease were investigated for hematologic abnormalities. The tests were useful in the clinical management of 6 (3.7 per cent) patients. Preoperative hematologic screening tests are recommended in patients with prostatic cancer, potential sepsis, and in patients with a known bleeding tendency.

Blood Coagulation Disorders↗

Clinical safety of recombinant factor VIII. The rFactor VIII Clinical Trial Group.

The safety of rFVIII has been studied in patients with severe or moderate hemophilia A in a noncontrolled observation study. A total of 40 patients participated in the study. Thirteen patients were included in stage I and 40 patients in stage II. Patients were treated at 11 centers in North America and Europe. As the results show, rFVIII is a substance with only a few unspecific side effects. Because of the constantly investigated infusion, vital signs and laboratory tests like hematology tests, serum chemistries, and urinalyses an elevation of the transaminases was found in 3 patients, which would not be correlated to rFVIII, as these patients had had in the past hepatitis B and probably non-A non-B hepatitis. Further studies with more patients will show whether these results can be confirmed.

Adult↗

In vitro chemosensitivity testing of hematological cancers: immunohistochemical detection of ornithine decarboxylase.

A new method for in vitro chemosensitivity testing of human lymphoma and leukemia patients has been developed. The method is based on the use of ornithine decarboxylase (ODC), a universal marker of proliferation, which is expressed early during the cell cycle and has a short half-life. This marker was detected by a quantitative immunohistochemical analysis, using an ODC antibody and a FITC-linked second antibody. The in vitro chemosensitivity of lymphocytes from four normal individuals was tested by the immunohistochemical method. Lymphocytes from 25 cancer patients were also examined. In drug-sensitive cells, the intensity of the marker declined in the presence of the drug, whereas resistance to the drug was demonstrated by the presence of the marker. A good correlation was found between the predicted chemosensitivity and the outcome of the therapy. It has been suggested that this approach could be used for in vitro chemosensitivity testing of hematological cancers and most likely also for other malignancies.

Adult↗

Usefulness of complete blood counts as a case-finding tool in medical outpatients.

OBJECTIVE: To determine the usefulness of routine complete blood counts as a case-finding tool in medical outpatients. DESIGN: Prospective evaluation in a consecutive, unselected cohort. SETTING: A university-based outpatient clinic providing primary and referral care in general internal medicine. PATIENTS: A total of 595 patients (mean age [+/- SD], 40 +/- 15 years) making their initial clinic visit. INTERVENTION: A complete blood count was done in all patients. Components of the complete blood count that were not indicated for diagnostic or management purposes at the initial visit were classified as routine tests. MAIN OUTCOME MEASURES: The number and nature of new diagnoses leading to new patient management; the number of additional visits and diagnostic tests precipitated by positive results. MAIN RESULTS: Of the 2378 tests done, 1540 (65%) were routine tests. The percentages of abnormal test results for the four hematologic test components were as follows: leukocyte count, 7.6%; hemoglobin, 5.8%; mean corpuscular volume (MCV) of red blood cells, 7.9%; and platelet count, 4.5%. In only three patients (0.5%) was a new diagnosis made that led to a new management strategy (treatment of iron deficiency). Further work-up was unprofitable in 14 patients (2.4%). Two additional visits were necessary because of abnormal results on routine tests. No abnormality-associated clinical disease developed during a 15-month follow-up period in patients with unexplained abnormal results on routine hematologic tests. CONCLUSIONS: The routine complete blood count has limited usefulness as a case-finding tool and has a minimal effect on care in middle-aged medical outpatients.

Adolescent↗