PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ION EXCHANGE RESINS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

[Sorption of acid ribonuclease from Penicillium brevi-compactum by various ion-exchange resins].

Sorption of acid ribonuclease from Penicillium brevi-compactum F-399 was studied. The effect of nature and structure of various ion-exchange resins on the sorption capacity and reversibility was determined. High rate and reversibility of the enzyme sorption on the strong base anion-exchange fiber TsM-A2 were demonstrated. It is suggested that sorption of acid ribonuclease of the TsM-A2 fiber proceeds as ion exchange and on carboxyl cation exchange resins as molecular sorption.

Chromatography, Ion Exchange↗

Equilibrium and dynamic investigations of organic acids adsorption onto ion-exchange resins.

The aim of the study was to determine properties of selected ion-exchange resins for citric and lactic acids recovery, to define sorption isotherms for these acids at different temperatures (in the range of 20-60 degrees C) and to determine diffusion coefficients inside sorbent particles. A mathematical model of the ion-exchange process in the chromatographic column and its experimental verification is also presented. During investigations 18 types of ion-exchange resins were tested. It was found that weakly basic resins were more suitable for the recovery process than strongly basic ones. The best resin for the separation of citric acid was Amberlite IRA-67 and for lactic acid Amberlite IRA-92. As a result of transient-state sorption experiments diffusion coefficients of the citric acid inside the sorbent particle at different temperatures were obtained. It was found that D(p) increased with the temperature by two times in the range of 20-60 degrees C, and its value at 60 degrees C was 7.2 x 10(-10) m(2)/s. The proposed mathematical model was applied to identify bed operation parameters in the column for the needs of the simulated moving bed chromatography method.

Adsorption↗

The use of ion-exchange resins as a blood preservation system.

A system using ion-exchange resins for the storage of whole blood was investigated. Blood was collected into CPD, thoroughly mixed and then divided into equal amounts. To one half of the split units, four grams of phosphate charged Amberlite IR-45 resin were added, while no additions were made to the other split units. Both aliquots were stored at 4 C, adhering to routine blood banking standards. The blood stored with the resin for up to 28 days maintained high levels of 2,3-DPG and adequate levels of ATP. This new resin system has several advantages over the present blood preservation technology. There is initial increase in pH that promotes greater glucose utilization. Inorganic phosphate is provided to maintain both ATP and 2,3-DPG levels. The resin buffers the blood and maintains a narrower pH range for red blood cell enzyme activity. The resin is totally inert, completely filterable and has the ability to adsorb bacteria from the suspending solution.

Adenosine Triphosphate↗

Carbon and SiC macroscopic beads from ion-exchange resin templates.

A method for preparing carbon and SiC macroscopic beads using ion-exchange resins as a macrotemplate that determines the macroshape and the pore structure of the product materials is reported. First, silicates are ion-exchanged into the resins to prevent the resin from collapsing during subsequent carbonization and allow them to be used as precursors for SiC formation. SiC is prepared via carbothermal reduction of carbon/silica composite beads obtained upon carbonization of the resin/silicate in an inert atmosphere. Finally, silica is removed by HF etching. Very high-surface area (1670-2026 m2 g-1) micro- or micro-/mesoporous carbon beads and relatively high-surface area (35-63 m2 g-1) macro- and meso-/macroporous SiC beads were prepared by the described method. The pore structure and the macroshape of the particles were controlled by the type of ion-exchange resins employed, gel or macroreticular.

Journal Article↗

Ion-exchange resin bezoar in a neonate.

A case of impacted ion-exchange resin causing intestinal obstruction associated with intraluminal calcification is described. This cause of bowel obstruction with intraluminal opacification has not previously been reported.

Bezoars↗

Using ion-exchange resins to study soil response to experimental watershed acidification.

Ion-exchange resins (IER) offer alternative approaches to measuring ionic movement in soils that may have advantages over traditional approaches in some settings, but more information is needed to understand how IER compare with traditional methods of measurement in forested ecosystems. At the Bear Brook Watershed in Maine (BBWM), one of two paired, forested watersheds is treated bi-monthly with S and N (28.8 and 25.2kg ha(-1)yr(-1) of S and N, respectively). Both IER and ceramic cup tension lysimeters were used to study soil solution responses after approximately 11 years of treatment. Results from both methods showed treatments resulted in the mobilization of base cations and Al, and higher SO(4)-S and inorganic N in the treated watershed. Both methods indicated similar differences in results associated with forest type (hardwoods versus softwoods), a result of differences in litter quality and atmospheric aerosol interception capacity. The correlation between lysimeter and IER data for individual analytes varied greatly. Significant correlations were evident for Na (r=0.75), Al (r=0.65), Mn (r=0.61), Fe (r=0.57), Ca (r=0.49), K (r=0.41) and NO(3)-N (r=0.59). No correlation was evident between IER and soil solution data for NH(4)-N and Pb. Both IER and soil solution techniques suggested similar interpretations of biogeochemical behavior in the watershed.

Ion Exchange Resins↗

[Speciation analysis of arsenic in traditional Chinese medicines by hydride generation-atomic fluorescence spectrometry with ion exchange resin separation].

A method for the determination of arsenic species (arsenide, arsenate) in traditional Chinese medicines using hydride generation atomic fluorescence spectrometry (HG-AFS) with ion exchange resin separation has been studied. The ion exchange resin was used to separate the arsenide and arsenate, and the separation conditions were investigated. The experimental conditions that influence the fluorescence intensity and the reduction of arsenic(V) were investigated and optimized, and the influence of foreign ions and its elimination were studied. The proposed method was applied to the determination of arsenic species in water leachate of traditional Chinese medicines. A detection limit of 89.1 ng x mL(-1) and a recovery range of 91.1%-109.3% were obtained.

Arsenates↗

[Clinical study on unmodified intravenous dried ion-exchange resin treated human normal immunoglobulin, SM-4300].

Unmodified intravenous dried ion-exchange resin treated human normal immunoglobulin, SM-4300, was administered to 4 patients with severely intractable infectious diseases. Obvious antipyretic effect, opsonic effect and and investigational findings on healing are not observed. However, in both subjective and objective clinical effects, we obtained the following test results, that is, 1 case of effective and 2 cases of rather effective. No side effects by SM-4300 were observed.

Adult↗

[Determination of palladium by ion exchange resin phase spectrophotometry].

A new method for the determination of palladium by ion exchange resin phase spectrophotometry has been established. It is based on the fixation of palladium as 1-(5-bromo-2-phridylazo)-2-naphthol-6-sulphonic acid (5-Br-PAN-S) compelled on a anion-exchange resin. The resin phase absorbances at 690 and 800 nm are measured directly and the linear range of 0-20 micrograms for palladium. The method has been applied to the determination of palladium in water samples and catalysts with satisfactory results.

Ion Exchange Resins↗