Insertion technique, not design, affects expulsion rates of postpartum intrauterine device.

A Lippes type intrauterine device (IUD) was modified to be used for immediate postpartum insertion. In 114 patients in whom the modified IUD was inserted immediately after delivery, expulsion rates at six months averaged approximately 30%. Expulsion rates were significantly different, at p less than 0.05, for women in whom the IUD was inserted digitally (19.5 +/- 5.6% at 6 months) compared to those in whom it was inserted using surgical forceps (39.6 +/- 7.1%). Furthermore, expulsion rates were higher for inexperienced inserters (p less than 0.01). We conclude that: 1) this modification of an otherwise standard IUD has a continued high expulsion rate, and 2) the technique of insertion has significant impact upon the likelihood of expulsion.

Adult↗

Immediate postplacental insertion and fixation of the CuFix postpartum implant system.

Since promising results were obtained with the CuFix interval implant system in international clinical trials conducted worldwide, a modification of the device adapting it for immediate postplacental insertion and fixation (IPPIF) seemed a logical approach to solve the expulsion problem of IUDs inserted at that particular time. Seventy-three insertions were performed at three university centers, during 1990 and 1991, both by skilled and unskilled investigators. The results of this multicenter study show the excellent retainability of the modified IUD supporting the validity of the anchoring principle. The insertion procedure is easy, requiring minimal training, and the insertion technique appeared to be safe.

Equipment Design↗

Performance of the frameless GyneFix and the TCu380A IUDs in a 3-year multicenter, randomized, comparative trial in parous women.

This study was conducted to evaluate a new and improved inserter (GyneFix) for the anchoring of the Frameless IUD in the uterine cavity. Previous studies conducted with a prototype inserter (Flexigard) did not show fully the advantages of the new anchoring concept because of the shortcomings of the Flexigard inserter and the complexity of the insertion technique. The GyneFix IUD was compared with the TCu380A IUD in six centers in China in approximately 300 women in each group. Only parous women were included in the study. The data from this 3-year, ongoing study demonstrate that the shortcomings of the inserter have been corrected, resulting in better performance and a much reduced rate of failed insertion/expulsion of the frameless and anchored device. The cumulative expulsion rate with the GyneFix IUD was 3.0 at 3 years (annual rates 2.67, 0.33, and 0.0, respectively) compared with a cumulative expulsion rate of 7.38 at 3 years with TCu380A (annual rates 4.63, 1.76, and 1.04, respectively). This difference is statistically significant. The majority of the expulsions with the anchored IUD occurred early in the study, indicating improper anchoring technique. The study also shows that both devices are highly efficacious. No pregnancies occurred with the GyneFix IUD (cumulative pregnancy rate 0.0 at 3 years) versus one pregnancy with TCu380A (cumulative pregnancy rate 0.34 at 3 years). The total use-related discontinuation rate at 3 years was significantly lower with the GyneFix IUD (8.34) than with the TCu380A IUD (14.13) and results in a higher rate of continuation with the GyneFix IUD compared to the TCu380A IUD (90.73 vs 85.25). Neither perforations nor pelvic inflammatory disease cases were encountered with either device in this study, demonstrating the safety of the anchoring system.

Adolescent↗

[Contraception with the intrauterine pessary Progestasert].

A prospective study was carried out from June 1973 to August 1976 in 131 women fitted with a newly developed IUD (Progestasert). The IUD's were removed as planned after 12 months with the exception of 4 cases in which they were retained for up to 17 months. The evaluation of the trial was performed according to the Life Table Analysis and the usual statistical methods. 1496 application months were evaluated. One case each of intrauterine and extrauterine pregnancies were observed. One patient experienced spontaneous expulsion of the IUD. In 9 cases medical reasons led to the removal of Progestasert at an earlier date. Duration, intensity, and interval of menstruation as well as frequency of spotting and dysmenorrhea were recorded. A slight increase in duration and interval of menstruation was seen whereas bleeding intensity was reduced. Increased spotting, especially during the first month after insertion, and a significant reduction of dysmenorrheal complaints were noted after 2 months. In addition to 8 removals due to bleeding disturbances, 6 other patients experienced spotting throughout the entire treatment period. Laboratory tests such as ESR, WBC, hemoglobin, hematocrit and cytological smear determinations were carried out. No pathological alterations of these parameters were found.

Adolescent↗

IUD (TCu380A) insertion following induced first trimester abortion.

In this study, 110 women (study group) who received an IUD (TCu380A) immediately after induced legal first trimester abortion were compared with 90 women (group 1) who started another type of contraception following legal abortion. Additionally, 100 women (group 2) who had an interval IUD insertion, were compared with both. In the study group, 3 (2.7%) patients were found to have an infection which did not fulfill the diagnostic criteria described by WHO and were treated easily by relevant antibiotics. One of 90 patients (1.1%) in group 1 developed acute PID after induced abortion within 7 days. None of group 2 patients had either a suspicion of pelvic infection or infection within the follow-up period (3 months). Among the women in the study group, bleeding and pain were not found to be more frequent, intense or of longer duration when compared with the other groups. Spontaneous expulsion of an IUD occurred in 2 patients (1.8%) of the study group and in 1 patient (1%) of group 2. At the end of the follow-up period, the continuation rates of the study group, group 1 and group 2 were 96.3%, 86.6%, 99%, respectively.

Abortion, Induced↗

Characteristics of women having abortion in China.

A pre-coded, closed response questionnaire was administered to women at abortion clinic sites in August 1985. The convenience sample was comprised of 1200 women, 200 samples in both Chengdu and the Lianshan Yi Autonomous Region in Sichuan Province, 400 in Nanjing and Jiangsu Province, and 400 in the municipality of Shanghai. The women were interviewed by physicians as part of the women's intake medical history. The sample yielded 574 respondents who were urban and 624 who were rural. The number of previous abortions reported ranged from 0 to 5. Nearly half of the abortion recipients had had at least one prior abortion and 18% had had two or more prior abortions. Education, age, marriage duration and residence have apparent effect on abortion order. The urban respondents reported an average of 1.08 children vs 1.60 children for the rural respondents. Approximately 72% of the respondents claimed to have been using a contraceptive method at the time they became pregnant. The most commonly used method was the IUD (41.6%), followed by the pill (21.3%) and the condom only (16.5%). Residence appeared to be the greatest factor determining the type of contraceptive methods. The data presented here are limited and cannot be generalized to the larger population. However, they do shed some light on the contraception characteristics of a group of women who undergo abortion procedures in China. Their response to questions to contracepting behavior prior to abortion suggests that the problem, in part, is behavioral. For example after the expulsion of the IUD, no other method was substituted to avert pregnancy. In order to alleviate the problem of contraceptive failure, and subsequent abortion, there are policy as well as training and education implications for the state.

Abortion Applicants↗

Cesarean section IUD insertion.

A trial was carried out on 154 selected volunteers who underwent cesarean section and then received an ML Cu 250 IUD during the operation. 56% of the operations were planned while 44% were not. The IUD was inserted in 65, 80, and 9 cases in the 1st, 2nd, and 3rd cesarean section, respectively. The patients were followed-up after 1, 3, 6, 12, and 24 months. Hospitalization time and postoperative morbidity did not increase with device insertion. Maternal lactation was not altered. 8% of the patients had postpartum bleeding which lasted more than 40 days. At the 1 year examination, 52% of the patients were menstruating normally while at 2 years, the percentage had increased to 62.5%. The acceptability, continuity, and efficiency of the contraceptive procedure proved successful. There were only 4 cases (2.6%) in which the device had to be removed for medical reasons (due largely to endometritis) and 8 cases (5.2%) because of patient desire (menstrual abnormalities). Spontaneous expulsion of the IUD occurred in 4 cases (2.6%). As of the present time, no pregnancies have been detected. The cesarean section insertion of an ML Cu 250 IUD produced excellent results and further, more widespread use is suggested.

Endometritis↗

IUD insertion at cesarean section--the Chinese experience.

This review reports the experience of nine studies in Chinese maternity hospitals with insertions of an intrauterine device (IUD) at the time of cesarean section. In contrast to the usually high expulsion rates associated with immediate postpartum vaginal insertions, all nine studies reported low expulsion rates, thus resulting in high continuation rates with this procedure, comparable to those with interval insertions. This immediate post-cesarean section insertion procedure was also found to be safe. These findings are of programmatic importance for postpartum family planning delivery services and may eventually lead to an understanding of the expulsion mechanism in postpartum IUD contraception. Results of these reports have been synthesized in this review. Seven of these nine reports were originally in Chinese and were translated into English for the benefit of a broad international audience. Future research directions on this insertion procedure are also discussed.

Adult↗

[Factors for expulsion of intrauterine device Tcu380A applied immediately postpartum and after a delayed period].

OBJECTIVE: To determine the frequency of expulsion of the intrauterine device TCu380A (IUD) inserted either immediately postpartum or after a delayed period. We aimed to identify the factors associated with expulsion. MATERIALS AND METHODS: A longitudinal and comparative study was carried out in three Family Medicine Units of the Instituto Mexicano del Seguro Social (IMSS) of Leon, Guanajuato. One hundred twenty-five women who had a vaginal delivery and who elected to have IUD inserted immediately after delivery participated in the study along with 125 women who elected to have the IUD inserted after a delayed period after delivery. Studied factors were parity, technique, and insertion by the doctors assigned to the service and medical personnel in training (pre or postdegree). A medical review was performed one month and three months after insertion of the IUD. Results were analyzed by chi-square and Student t test. RESULTS: The expulsion rates of IUDs during immediate puerperium and also after a delayed period were 16 and 2.7%, respectively (p<0.0004). There was no statistically significant association between expulsion of the IUD and the following factors that were taken into account: age, primipara, personnel who inserted the device, and the application technique. In immediate puerperium, 25.9% of women who had multiple deliveries expelled the IUD, and in those who delayed IUD insertion, it was 4% (p=0.03). CONCLUSIONS: There is a greater risk of expulsion if the IUD is inserted immediately after delivery and it is associated with multiparity. The percentage of expulsion in immediate puerperium is similar to that reported in the literature.

Adult↗

Clinical experience with intrauterine devices in a private practice.

Clinical experience with intrauterine devices was evaluated, based on 627 insertions over a 14-year period in a private practice. Overall, there were few differences in the event rates leading to IUD discontinuation for the IUDs evaluated, principally Cu-7, Dalkon Shield and Lippes Loop. Pelvic infections were infrequent (0.7-2.2 cases per 100 woman-years of IUD use). The rate of PID in the study population appeared to be similar to that noted in the general population. IUD use did not appear to compromise future fertility, based on evaluations of patients after removal of their IUDs or from their return to fertility following IUD removal. IUD event rates (pregnancy, expulsion, displacement, removal for bleeding and/or pain) were related to the difference between endometrial cavity length and IUD length. A significant increase in the event rates was noted, regardless of the IUD type, when the endometrial cavity length exceeded IUD length by 2.0 cm or more, or when the difference between the endometrial cavity and IUD length was less than 0.5 cm.

Adult↗

Hormonally impregnated intrauterine systems (IUSs), versus other forms of reversible contraceptives as effective methods of preventing pregnancy.

OBJECTIVES: To assess the contraceptive efficacy, tolerability and acceptability of hormonally impregnated intrauterine systems (IUSs) in comparison to other reversible contraceptive methods. SEARCH STRATEGY: Literature was identified through database searches, reference lists and individuals/organisations working in the field. SELECTION CRITERIA: All randomised controlled trials comparing IUSs with other forms of reversible contraceptives and reporting on pre-determined outcomes in women of reproductive years. The primary outcomes were pregnancy due to method/user failure and continuation rate. DATA COLLECTION AND ANALYSIS: The quality assessment of studies and data extraction were completed independently by two blinded reviewers. A quality checklist was designed to identify general methodological and contraceptive specific factors which could bias results. Events per women months and single decrement life table rates were extracted where possible for pregnancy, continuation, adverse events and reasons for discontinuation. Events per total number of women at follow up were collected for hormonal side effects and menstrual disturbance. When appropriate, data were pooled at the same points of follow up to calculate rate ratios in order to determine the relative effectiveness of one method compared to another. For the single decrement life table rates, the rate differences were pooled to determine the absolute difference in effectiveness of one method compared to another. Interventions were only combined if the contraceptive methods were similar. Non-hormonal IUDs were divided into three categories for the purpose of comparison with IUSs: IUDs >250mm2 (i.e. CuT 380A IUD and CuT 380 Ag IUD), IUDs <=250mm2 (i.e. Nova-T, Multiload, CuT 200 and CuT 220 IUDs) and non-medicated IUDs. MAIN RESULTS: Nineteen RCTs comparing hormonally impregnated IUSs to a reversible contraceptive method met the inclusion criteria and it was possible to include eight of these in the meta-analyses, four comparing LNG-20 IUSs with non-hormonal IUDs, one comparing the LNG-20 IUS with Norplant-2 and three comparing Progestasert with non-hormonal IUDs. No significant difference was observed between the pregnancy rates for the LNG-20 users and those for the IUD >250mm2 users. However, women using the LNG-20 IUS were significantly less likely to become pregnant than those using the IUD <=250mm2. Women using the LNG-20 IUS were more likely to experience amenorrhoea and device expulsion than women using IUDs >250mm2. LNG-20 users were significantly more likely than all the IUD users to discontinue because of hormonal side effects and menstrual disturbance, which on further breakdown of the data was due to amenorrhoea. When the LNG-20 IUS was compared to Norplant-2, the LNG-20 users were significantly more likely to experience amenorrhoea and oligomenorrhoea, but significantly less likely to experience prolonged bleeding and spotting. No other significant differences were observed. Progestasert users were significantly less likely to become pregnant and less likely to continue on the method than non-medicated IUD users after one year, but no significant differences was noted for these two outcomes when Progestasert users were compared to IUD<=250mm2 users. The only other significant differences found in the meta-analyses were that Progestasert users were less likely to expel the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWER'S CONCLUSIONS: Current evidence suggests LNG-20 IUS users are no more or less likely to have unwanted pregnancies than IUD >250mm2 and Norplant-2 users. The LNG-20 IUS was more effective in preventing either intrauterine or extrauterine pregnancies than IUDs <=250mm2. The contraceptive effectiveness of Progestasert was significantly better than non-medicated IUDs, but no difference was observed when compared to IUDs<=250mm2. Continuation of LNG-20 IUS use was similar to continuation of the non-hormonal IUDs and Norplant-2. Amenorrhoea was the main reason for the discontinuation for the LNG-20 IUS and women should be informed of this prior to starting this method.

Contraceptive Agents, Female↗

Hormonally impregnated intrauterine systems (IUSs) versus other forms of reversible contraceptives as effective methods of preventing pregnancy.

BACKGROUND: In the 1970s a new approach to the delivery of hormonal contraception was researched and developed. It was suggested that the addition of a progestogen to a non-medicated contraceptive device improved its contraceptive action. An advantage of these hormonally impregnated intrauterine systems (IUS) is that they are relatively maintenance free, with users having to consciously discontinue using them to become pregnant rather than taking a proactive daily decision to avoid conception. OBJECTIVES: To assess the contraceptive efficacy, tolerability and acceptability of hormonally impregnated intrauterine systems (IUSs) in comparison to other reversible contraceptive methods. SEARCH STRATEGY: Literature was identified through database searches, reference lists and individuals/organisations working in the field. Searches covered the period from 1972 to November 2003. SELECTION CRITERIA: All randomised controlled trials comparing IUSs with other forms of reversible contraceptives and reporting on pre-determined outcomes in women of reproductive years. The primary outcomes were pregnancy due to method/user failure and continuation rate. DATA COLLECTION AND ANALYSIS: The quality assessment of studies and data extraction were completed independently by two blinded reviewers. A quality checklist was designed to identify general methodological and contraceptive specific factors which could bias results. Events per women months and single decrement life table rates were extracted where possible for pregnancy, continuation, adverse events and reasons for discontinuation. Events per total number of women at follow up were collected for hormonal side effects and menstrual disturbance. When appropriate, data were pooled at the same points of follow up to calculate rate ratios in order to determine the relative effectiveness of one method compared to another. For the single decrement life table rates, the rate differences were pooled to determine the absolute difference in effectiveness of one method compared to another. Interventions were only combined if the contraceptive methods were similar. Non-hormonal IUDs were divided into three categories for the purpose of comparison with IUSs: IUDs >250mm2 (i.e. CuT 380A IUD and CuT 380 Ag IUD), IUDs <=250mm2 (i.e. Nova-T, Multiload, CuT 200 and CuT 220 IUDs) and non-medicated IUDs. MAIN RESULTS: Twenty-one RCTs comparing hormonally impregnated IUSs to a reversible contraceptive method met the inclusion criteria and it was possible to include eight of these in the meta-analyses, four comparing LNG-20 IUSs with non-hormonal IUDs, one comparing the LNG-20 IUS with Norplant-2 and three comparing Progestasert with non-hormonal IUDs. No significant difference was observed between the pregnancy rates for the LNG-20 users and those for the IUD >250mm2 users. However, women using the LNG-20 IUS were significantly less likely to become pregnant than those using the IUD <=250mm2. Women using the LNG-20 IUS were more likely to experience amenorrhoea and device expulsion than women using IUDs >250mm2. LNG-20 users were significantly more likely than all the IUD users to discontinue because of hormonal side effects and menstrual disturbance, which on further breakdown of the data was due to amenorrhoea. When the LNG-20 IUS was compared to Norplant-2, the LNG-20 users were significantly more likely to experience amenorrhoea and oligomenorrhoea, but significantly less likely to experience prolonged bleeding and spotting. No other significant differences were observed. Progestasert users were significantly less likely to become pregnant and less likely to continue on the method than non-medicated IUD users after one year, but no significant difference was noted for these two outcomes when Progestasert users were compared to IUD<=250mm2 users. The only other significant differences found in the meta-analyses were that Progestasert users were less likely to expel the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWERS' CONCLUSIONl the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWERS' CONCLUSIONS: Current evidence suggests LNG-20 IUS users are no more or less likely to have unwanted pregnancies than IUD >250mm2 and Norplant-2 users. The LNG-20 IUS was more effective in preventing either intrauterine or extrauterine pregnancies than IUDs <=250mm2. The contraceptive effectiveness of Progestasert was significantly better than non-medicated IUDs, but no difference was observed when compared to IUDs<=250mm2. Continuation of LNG-20 IUS use was similar to continuation of the non-hormonal IUDs and Norplant-2. Amenorrhoea was the main reason for the discontinuation for the LNG-20 IUS and women should be informed of this prior to starting this method.

Contraceptive Agents, Female↗

An evaluation of six new intrauterine devices.

A newer generation of IUDs that includes the Copper T-380A/Ag (TCu-380A/Ag) IUDs and the Multiload Copper-375 (MLCu375) IUDs has been developed and marketed. The high efficacy of these IUDs in preventing accidental pregnancies has been equated to that of oral contraceptives and even sterilization. However, the reduction of two other IUD-related pertinent events, namely, expulsion and medical removal due to bleeding and/or pain, has been less impressive. Therefore, efforts are continuing to develop new IUDs. In this paper, the authors review the physical structures of six new IUDs: the CU-SAFE, Cu-Fix, Ombrelle, Fincoid, and Multiload Mark II IUDs, and the intracervical fixing device (ICFD). The clinical performance of the first four devices is also evaluated. Independent, noncomparative studies suggest that all of the four new IUDs may perform as well as, or even better than, the TCu-380A IUD in terms of expulsions and medical removals attributable to bleeding and/or pain. However, we deem these results tentative, and emphasize the need for multi-center, randomized comparative clinical trials with larger sample sizes and long-term follow-up.

Evaluation Studies as Topic↗

The value of X-ray with uterine sound in the diagnosis of IUDs with missing tails.

Missing IUD tails may result from expulsion, retraction of filaments, uterine perforation or pregnancy. Missing IUD tails occur in 5-25% of all IUD insertions, and require a safe and correct diagnostic technique. Plain X-ray with uterine sound in utero is a popular, simple technique which does not require special skills. This study discusses the feasibility and accuracy of this method in 104 women presenting with a history of missed IUD. Twenty women with suspected pregnancy or uterine abnormalities were excluded from the study. The diagnosis was verified by examination of the patient under anesthesia, D & C, laparoscopy or laparotomy. The accuracy rate was 95.23% (80 women). The diagnosis was wrong in 4.76% (4 women) where the X-ray technique wrongly diagnosed intrauterine location of the device, while examination under anesthesia and laparoscopy located these 4 devices in an extrauterine location. Through the use of this technique it was possible to reduce the hospital stay to one day in 95% (80 patients). The technique is feasible, reliable and without complications; it is particularly suitable in hospitals where other diagnostic facilities are not available.

Female↗

Intrauterine device insertion-related complications: can they be predicted?

OBJECTIVE: To determine risk factors affecting the incidence of intrauterine device (IUD) insertion-related complications and failures and, in particular, whether postcoital IUD insertions have a higher incidence of complications than routine IUD insertions. DESIGN: Retrospective case notes analysis. PARTICIPANTS: The study examined 545 case notes of patients having IUD insertions at East Cheshire NHS Trust family planning clinics between 1 October 1997 and 31 December 2000. MAIN OUTCOME MEASURES: The incidence of complications at insertion, or up to 12 weeks after insertion, was determined and included failed insertion, cervical problems, syncope, bradycardia, convulsions, early perforation and early expulsion. Fourteen potential risk factors were examined to determine the effect on incidence of complications. RESULTS: Failed insertions were statistically more likely in women who had never previously had a vaginal delivery and also when a less experienced doctor performed the insertion. Nulliparous women were at statistically increased risk of cervical problems and bradycardia. Cervical problems at insertion also increased significantly with age. Patients who were amenorrhoeic at insertion were more likely to suffer an early IUD expulsion. CONCLUSIONS: Of the potential risk factors, nulliparity was the most important. IUD insertion failures and complications were no more common in postcoital than routine IUD insertions. In general, complications were unpredictable, indicating the need for constant vigilance and the inserting doctor being trained and prepared to deal with any complication arising.

Adolescent↗

Transvaginal ultrasonographic assessment of the expulsion rate of intrauterine devices inserted in the immediate postpartum period: a pilot study.

OBJECTIVE: To compare the expulsion rates of intrauterine devices (IUDs) inserted in the immediate postpartum after vaginal birth and cesarean section. METHODS: Nineteen patients who had a vaginal birth and 19 patients who had a cesarean section at Hospital de Clínicas de Porto Alegre, Brazil, were selected for copper T 380A IUD insertion. With the aim of detecting clinically unnoticed dislodged devices, ultrasound examinations were performed at 1 month and between 3 and 12 months after delivery. The IUDs were considered completely expelled when found outside the endometrial cavity (e.g., in the cervical canal) or outside the uterus (in the vagina). RESULTS: Expulsion rates were statistically different between the two groups: after a vaginal birth, 50% (ultrasound only) + 27.8% (clinical examination); and post-cesarean section, 0% (p < .001; OR 5.75, 95% CI 2.36-14.01). CONCLUSION: Considering that the contraceptive efficacy of IUDs is associated with their intrauterine location, the high expulsion rates seen when they are inserted immediately after vaginal delivery contraindicate their use in this setting. The use of IUDs immediately after a cesarean section is still a reasonable alternative because its expulsion rate was zero. Ultrasound assessment of IUD positioning performed better than clinical examination, which failed to detect expulsion after postpartum insertion in 75% of the cases (9 from 12 cases).

Adult↗

Performance of the frameless IUD (Flexigard prototype inserter) and the TCu380A after six years as part of a WHO multicenter randomized comparative clinical trial in parous women.

The clinical performance of the new Frameless IUD was compared with the TCu380A, the most widely used copper IUD in the world today. Insertions of the Frameless IUD were conducted with a prototype inserter (Flexigard). We report on the 6-year results from a randomized comparative clinical trial conducted at the Shanghai Institute of Planned Parenthood Research, as part of an international multicenter WHO clinical trial, involving 200 women, respectively recruited for use of each device. The cumulative 6-year pregnancy rates were 0.0 per 100 women for the Frameless IUD and 3.3 for TCu380A. Termination due to partial expulsion was significantly less for the Frameless IUD as compared with TCu380A (0.0 and 4.3 per hundred women, respectively). Complete expulsion, bleeding, pain, bleeding and pain and other medical reasons for termination did not differ significantly between the two devices. The net cumulative continuation rates at six years per 100 women were 80.8 for TCu380A, and 83.0 for the Frameless IUD. Both Frameless IUD and TCu380A are highly effective, safe and acceptable contraceptive devices, because of low pregnancy rates (per 100 women), and low termination rates due to expulsion, pain, bleeding, and bleeding and pain. Due to its anchoring, the Frameless IUD is significantly more effective than the TCu380A IUD as regards proper retention of the IUD in the uterine cavity. This may also explain its lower failure rate.

Adult↗

The relationship of IUD dimensions to event rates.

The relationship of horizontal-to-vertical ratio (HVR) of 14 commonly used IUDs was compared to medical removal and expulsion rates. A significant positive statistical correlation between IUD HVR and medical removal rate existed. However, no correlation existed between HVR and expulsion. A ratio of about 0.5 for multiparous and 0.7 for nulliparous women less frequently in medical removal of the device. The endometrial cavity length sizes have boundary values on IUD width of 15-18 mm for nulliparae and 18-25 mm for multiparae. The endometrial cavity is thus functionally an isosceles triangle or isosceles trapezoid.

Birth Rate↗