PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “LARYNGOSCOPY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

The effect of an intermediate dose of labetalol on heart rate and blood pressure responses to laryngoscopy and intubation.

STUDY OBJECTIVE: To evaluate the efficacy of an intermediate dose of labetalol (0.4 mg/kg) for attenuation of heart rate (HR) and blood pressure (BP) responses to laryngoscopy and intubation. DESIGN: Randomized, double-blind, placebo-controlled study. SETTING: Inpatient gynecology service at a university medical center. PATIENTS: Two groups of 18 patients each undergoing elective surgery under general anesthesia. INTERVENTIONS: Patients received either 0.4 mg/kg of labetalol or an equal volume of normal saline 5 minutes prior to laryngoscopy and intubation. MEASUREMENTS AND MAIN RESULTS: HR and BP were measured upon arrival in the operating room (OR) (baseline) and at 1 minute intervals thereafter for 4 minutes prior to intubation and through 10 minutes following intubation. The labetalol group had a significantly lower HR from induction through 1 minute following intubation. Intragroup differences in HR were greatest immediately following laryngoscopy and intubation (33% increase above baseline for the placebo group vs 1% for the labetalol group, p less than 0.05). At the same time, a significant increase in mean arterial pressure (MAP) from baseline was noted in both groups (29% for the placebo group vs 23% for the labetalol group), but the difference between the groups was not significant. CONCLUSIONS: An intermediate dose of labetalol blunted the HR response to laryngoscopy and intubation during rapid-sequence induction in healthy patients but had a minimal effect on BP.

Adult↗

Head and neck elevation beyond the sniffing position improves laryngeal view in cases of difficult direct laryngoscopy.

STUDY OBJECTIVE: To determine the influence of head and neck elevation beyond the "sniffing position" during difficult direct laryngoscopy. DESIGN: Prospective case series, with each patient serving as her or his control. SETTING: University hospital. PATIENTS: 21 patients scheduled for general anesthesia and endotracheal intubation, all of whom presented with a laryngoscopic grade III view (Cormack & Lehane) during direct laryngoscopy in the sniffing position. INTERVENTIONS: An assistant applied external laryngeal pressure with his left hand and elevated the patient's head and neck above the sniffing position with his right hand to improve laryngeal view. MEASUREMENTS AND MAIN RESULTS: External laryngeal pressure and elevation of head and neck improved the laryngoscopic view in 19 of 21 patients to grade II (p = 0.001, Wilcoxon signed rank test). Beyond that, laryngoscopy with the neck maximally elevated enabled visualization of parts of the cords in six patients (30%). CONCLUSIONS: Elevation of the head and neck beyond the sniffing position may improve visualization of glottic structures in cases of difficult direct laryngoscopy, leading to better intubation performance.

Adult↗

Hemodynamic and catecholamine response to tracheal intubation: direct laryngoscopy compared with fiberoptic intubation.

STUDY OBJECTIVE: To compare the stress response following tracheal intubation using direct laryngoscopy to that using fiberoptic bronchoscopy technique. DESIGN: Randomized, prospective study. SETTING: Operating rooms in a teaching hospital. PATIENTS: 51 ASA physical status I and II patients who were scheduled for an elective surgery with general anesthesia. INTERVENTIONS: Patients were randomly assigned to receive either direct laryngoscopy or fiberoptic orotracheal intubation, as part of general anesthesia. A uniform protocol of anesthetic medications was used. MEASUREMENTS: Blood pressure and heart rate were measured before induction, before endotracheal intubation, and 1, 2, 3, and 5 minutes afterwards. Catecholamine (epinephrine and norepinephrine) blood samples were drawn before the induction, and 1 and 5 minutes after intubation. MAIN RESULTS: Duration of intubation was shorter in the direct laryngoscopy group (16.9 (16.9 +/- 7.0 sec, range 8 to 40) compared with the fiberoptic intubation group (55.0 +/- 22.5 sec, range 29 to 120), p < 0.0,001. In both groups, blood pressure and heart rate were significantly increased at 1, 2, and 3 minutes after intubation, but there was no significant difference between the two study groups. Catecholamine levels did not increase after intubation and did not correlate with the hemodynamic changes. CONCLUSIONS: The use of either direct laryngoscopy or fiberoptic bronchoscopy produces a comparable stress response to tracheal intubation. Catecholamine levels do not correlate with the hemodynamic changes.

Adult↗

Reflex activity caused by laryngoscopy and intubation is obtunded differently by meptazinol, nalbuphine and fentanyl.

BACKGROUND AND OBJECTIVE: To evaluate the different potencies of several opioids in obtunding reflex mechanisms of laryngoscopy and intubation. METHODS: Three groups of patients (each n = 25, ASA 1-2) undergoing elective plastic surgery were randomly given meptazinol (2.5 mg kg-1), nalbuphine (0.3 mg kg-1) or fentanyl (5 microg kg-1) in a blinded fashion prior to laryngoscopy and intubation. This was followed by a standardized bolus induction of a barbiturate and a muscle relaxant. The response to laryngoscopy and intubation was studied, using blood pressure, heart rate and bispectral index. RESULTS: With fentanyl, there was an increase of heart rate by 17%, and systolic blood pressure by 7% when compared to control. Bispectral index dropped an additional 8% when compared to 1 min after barbiturate induction. In the nalbuphine group there was a 16% increase in systolic blood pressure, and a 16% increase in heart rate when compared to control. Also, bispectral index increased by 18% when compared to 1 min after barbiturate injection. The group receiving meptazinol demonstrated no cardiovascular changes although bispectral index dropped by an additional 19% when compared to 1 min after barbiturate injection. CONCLUSION: Meptazinol, appears to depress cardiovascular stimulatory effects and electroencephalogram arousal induced by laryngoscopy and intubation better than nalbuphine or fentanyl.

Adolescent↗

Laryngoscopy findings in outpatient notes: the accuracy of the recording of the side of the lesion.

An analysis of 100 patient notes was performed in the South-west Thames Region to determine the accuracy of recording the side of the abnormality in outpatient clinic notes when compared to the findings at direct laryngoscopy. Direct laryngoscopy was felt to be the most accurate method of viewing the larynx. The results were analysed to determine if the specific method of outpatient laryngoscopy or grade of examiner influenced the error rates. Inconsistencies occurred in 29% of the clinic notes when a diagram of the larynx was present. Specialist Registrars made 59% of the errors. Flexible nasendoscopy accounts for more errors than indirect laryngoscopy.

Ambulatory Care↗

EEG arousal during laryngoscopy and intubation: comparison of thiopentone or propofol supplemented with nitrous oxide.

We studied EEG arousal after laryngoscopy and intubation with standardized bolus induction of anaesthesia. Twenty patients were prospectively allocated randomly to induction with propofol 3 mg kg-1 (n = 10) or thiopentone (6 mg kg-1 (n = 10) and 50% nitrous oxide in oxygen. Neuromuscular block was produced with vecuronium 0.2 mg kg-1 given 30 s after induction. Three minutes after induction, laryngoscopy was performed for 60 s, with intubation at 3 min 30 s, and study end at 5 min. Nociception to laryngoscopy and intubation was followed by loss of low (relative delta activity change: thiopentone -30%, propofol -7%; P < 0.05) and a shift to higher frequency EEG activity (beta activity change: thiopentone +647%, propofol +61%; P < 0.05). This EEG arousal was greater in the thiopentone group, despite the fact that EEG depression was similar to that produced by propofol before laryngoscopy and intubation. Propofol and thiopentone in combination with nitrous oxide had similar cortical depressant effects, but propofol appeared to depress subcortical nociceptive processing more than thiopentone. While the degree of cortical EEG depression seems less useful for predicting reaction to subsequent nociception, EEG arousal reactions may prove suitable for monitoring intra-anaesthetic nociception and its modulation.

Anesthetics, Inhalation↗

Sternomental distance as the sole predictor of difficult laryngoscopy in obstetric anaesthesia.

Sternomental distance and view at laryngoscopy were documented in 523 parturients undergoing elective or emergency Caesarean section under general anaesthesia. Eighteen (3.5%) had a grade III or IV laryngoscopic view (Cormack and Lehane's classification) and were classified as potentially difficult tracheal intubations. There was a significant difference between sternomental distance in those patients with a grade III or IV laryngoscopic view compared with those with a grade I or II (13.17 (SD 1.54) cm vs 14.3 (1.49) cm; P = 0.0013). A sternomental distance of 13.5 cm or less with the head fully extended on the neck and the mouth closed provided, using discriminant analysis, the best cut-off point for predicting subsequent difficult laryngoscopy. A sternomental distance of 13.5 cm or less had a sensitivity, specificity, positive and negative predictive values of 66.7%, 71.1%, 7.6% and 98.4%, respectively. While there was no association between sternomental distance and age, weight, height or body mass index (BMI), there was a significant association between grade of laryngoscopy (III and IV) and older (P = 0.049) and heavier (P = 0.0495) mothers. The results suggest that while sternomental distance on its own may not be an adequate sole predictor of subsequent difficult laryngoscopy the measurement should be incorporated into a series of quick and simple preoperative tests.

Adolescent↗

Effects of lightwand (Trachlight) compared with direct laryngoscopy on circulatory responses to tracheal intubation.

We compared the effects of the lightwand technique on circulatory responses to tracheal intubation with those of direct-vision laryngoscopy. Forty adult patients received propofol and vecuronium, and their lungs were ventilated for 2 min via a mask with 5% sevoflurane in oxygen, after which the trachea was intubated orally using either the lightwand (Trachlight, n = 20) or the Macintosh laryngoscope (n = 20). Maximum mean arterial pressure changes did not differ between groups during (lightwand group, 25 (SD 21) mm Hg vs laryngoscopy group, 23 (19) mm Hg) and after (21 (24) mm Hg vs 21 (16) mm Hg) tracheal intubation. Maximum heart rate changes were similar for groups during (16 (14) beat min-1 vs 16 (15) beat min-1) and after (2 (11) beat min-1 vs 7 (19) beat min-1) tracheal intubation. There were no differences between the lightwand technique and direct-vision laryngoscopy in changes in mean arterial pressure and heart rate during and after tracheal intubation. We conclude that the effects of the lightwand technique on circulatory responses to tracheal intubation were similar to those of direct-vision laryngoscopy.

Adult↗

Force, torque, and stress relaxation with direct laryngoscopy.

The anesthetist exerts axial force on the laryngoscope handle to expose the glottis. The anesthetist must also apply a perpendicular force to balance the torque on the laryngoscope. Several studies have measured axial force during direct laryngoscopy, but none has measured torque. This study used a newly designed laryngoscope handle to measure force and torque simultaneously during direct laryngoscopy of ASA grade I and II patients requiring general anesthesia and endotracheal intubation for elective surgery. In 58 patients, peak force averaged 38 +/- 2 newtons. Peak torque averaged 4 +/- 0.2 newton-meters, and the perpendicular force was estimated as 40 +/- 2 newtons. The peak torque that can be balanced by the wrist is approximately 6 newton-meters, suggesting that torque may be a limiting factor for laryngoscopy in some situations. Peak force and torque demonstrated stress relaxation, a viscous property of biologic tissues. Force and torque decreased monoexponentially to approximately 70% of peak values with a half-time of 4 +/- 0.3 s. The phenomenon occurred in spite of administration of muscle relaxants, and was probably due to stress relaxation of pharyngeal tissues that are passively stretched during laryngoscopy.

Adult↗

The disposition of the cervical spine and deformation of available cord space with conventional- and balloon laryngoscopy-guided laryngeal intubation: a comparative study.

UNLABELLED: Orotracheal intubation causes cervical spine (C-spine) extension and potential (hypothetical) space available for the cord (SAC)-deformation. In the present study, we determined and compared the changes induced by conventional- and balloon laryngoscopy-guided orolaryngeal intubation in the upper C-spine's osseous unit-orientation, segmental angulation, segmental SAC-sagittal surface areas (SSAs), segmental/total posterior SAC-aspect, and segmental SAC-width. Eight healthy volunteers were enrolled. A set of neutral head position (baseline)- and two sets of intubation-lateral C-spine radiographs were obtained. Relative to baseline, both intubation techniques induced significant changes in the occiput (OCC)-, third cervical vertebra (C3)-, C4-, and C5-orientation, the OCC-C1-segmental angulation, all the segmental SAC-SSAs, and the OCC-C1-, and C1-2-posterior SAC-aspect (P < 0.05 to < 0.001); conventional intubation caused additional significant changes in C2-orientation, total (OCC through C5)-posterior SAC-aspect, and OCC-C1-SAC-width (P < 0.05 to < 0.001). Relative to conventional intubation, balloon-assisted intubation caused less change in C3-orientation and C2-3-SAC-width (P < 0.05), and less reduction in OCC-C1-, C1-2-, and C4-5-SAC-SSAs (P < 0.05 to < 0.01). Orotracheal intubation should be cautiously performed in patients with space-occupying upper-C-spine-SAC lesions, even if there is no concomitant osseous/ligamentous pathology. In such cases, balloon laryngoscopy may be chosen over the conventional technique, because it causes less SAC deformation. IMPLICATIONS: This study shows that direct laryngoscopy-guided orotracheal intubation causes deformation of the upper cervical space available for the cord, even in the absence of cervical spine instability. These effects are attenuated with balloon laryngoscopy, and thus, its use is recommended in patients with space-occupying lesions within the spinal canal.

Adult↗

What is the best way to determine oropharyngeal classification and mandibular space length to predict difficult laryngoscopy?

BACKGROUND: Previous studies have suggested that the degree of visibility of oropharyngeal structures (OP class) and mandibular space (MS) length can predict difficult laryngoscopy. However, those studies were either inconsistent or omit description of how to perform these tests with regard to body, head and tongue position, and the use of phonation, hyoid versus thyroid cartilage and inside versus outside of the mentum. The purpose of this investigation was to determine which method of testing best predicts difficult laryngoscopy. METHODS: In each of 213 consenting adults the OP class was determined in 24 method combinations: two body positions (sitting and supine), three head positions (neutral, sniff, and full extension), two tongue positions (in and out), and with and without phonation. In each patient MS length was measured in 24 method combinations: two body positions (sitting and supine), three head positions (neutral, sniff, and full extension), two distal end points (hyoid and thyroid cartilage), and two proximal end points (inside and outside of the mentum). In each patient the laryngoscopic grade was determined at the time of induction of anesthesia. We defined laryngoscopic grades III (n = 24) and 4 (n = 0) as difficult. The area under the receiver operating characteristic curve (ROC area) for each combination was used to compare the combinations and determine significant differences: ROC area = 0.5 implied a totally uninformative combination and ROC area = 1.0 a combination that predicted perfectly. Logistic regression analysis was used to calculate a predictor of difficult intubation that combined both OP class and MS length (the performance index). The performance index could then be used to calculate sensitivity, specificity, positive and negative predictive value, and probability of difficult intubation. RESULTS: The ROC areas for the different combinations used to assess OP class ranged from 0.78 to 0.94. The best combination was with the patient sitting, head in extension, tongue out, and with or without phonation. For MS length, the ROC areas ranged from 0.58 to 0.77; the best combination was the patient sitting, with the head in extension, with distance measured from the inside of the mentum to the thyroid cartilage. Combining the OP class and MS length (performance index = 2.5 X OP class - MS length in centimeters) significantly increased predictability of difficult intubation. At performance index = 0 and = 2, the probability of difficult intubation was 3.5% and 24%, respectively. With clinically relevant cutpoints for the performance index it was found that most difficult intubations could be predicted, but approximately half of those predicted to be difficult would in fact be easy. CONCLUSIONS: Based on the above ROC areas and ease of performing the test for the patient, we recommend that these tests be performed with patients in the sitting position, with the head in full extension, the tongue out, and with phonation, and with distance measured from the thyroid cartilage to inside of the mentum. Nevertheless, it is clear that these two tests, either used alone or in combination, will fail to predict a few difficult laryngoscopies and that they will predict difficult laryngoscopy in a significant number of patients in whom the trachea is easy to intubate.

Adult↗

Cervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes.

BACKGROUND: Direct laryngoscopy requires movement of the head, neck, and cervical spine. Spine movement may be limited for anatomic reasons or because of cervical spine injury. The Bullard laryngoscope, a rigid fiberoptic laryngoscope, may cause less neck flexion and head extension than conventional laryngoscopes. The purpose of this study was to compare head extension (measured externally), cervical spine extension (measured radiographically), and laryngeal view obtained with the Bullard, Macintosh, and Miller laryngoscopes. METHODS: Anesthesia was induced in 35 ASA 1-3 elective surgery patients. Patients lay on a rigid board with head in neutral position. Laryngoscopy was performed three times, changing between the Bullard, Macintosh, and Miller laryngoscopes. Head extension was measured with an angle finder attached to goggles worn by the patient. The best laryngeal view with each laryngoscope was assessed by the laryngoscopist. In eight patients, lateral cervical spine radiographs were taken before and during laryngoscopy with the Bullard and Macintosh blades. RESULTS: Median values for external head extension were 11 degrees, 10 degrees, and 2 degrees with the Macintosh, Miller, and Bullard laryngoscopy (P < 0.01), respectively. Significant reductions in radiographic cervical spine extension were found for the Bullard compared to the Macintosh blade at the atlantooccipital joint, atlantoaxial joint, and C3-C4. Median atlantooccipital extension angles were 6 degrees and 12 degrees for the Bullard and Macintosh laryngoscopes, respectively. The larynx could be exposed in all patients with the Bullard but only in 90% with conventional laryngoscope (P < 0.01). CONCLUSIONS: The Bullard laryngoscope caused less head extension and cervical spine extension than conventional laryngoscopes and resulted in a better view. It may be useful in care of patients in whom cervical spine movement is limited or undesirable.

Adult↗

Skin vasomotor reflex predicts circulatory responses to laryngoscopy and intubation.

BACKGROUND: An evaluation of autonomic reactivity may help to predict circulatory responses to intubation. The relation between the magnitude of the skin vasomotor reflex (SVmR) immediately before laryngoscopy and the circulatory responses to intubation was examined. METHODS: Forty-four adult patients (classified as American Society of Anesthesiologists physical status I or II) were studied. General anesthesia was induced with fentanyl and thiamylal and maintained with nitrous oxide and sevoflurane. The SVmR was evoked by an electrostimulus to the ulnar nerve, and decreases in skin blood flow were detected using a laser-Doppler flowmeter. In study 1, two groups of patients were studied. In the monitored group (n = 14), laryngoscopy was performed when the SVmR amplitude had decreased to less than 0.1. In the control group (n = 15), intubation was performed regardless of changes in the SVmR amplitude. In study 2, after induction, the end-tidal concentration of sevoflurane was maintained at 1 MAC (n = 9) or 1.3 MAC (n = 6) for 5 min. The SVmR was tested by changing the electric intensity. RESULTS: In study 1, the blood pressure and heart rate of the control group increased significantly (P < 0.01) after laryngoscopy. The blood pressure of the monitored group did not increase. The SVmR amplitude and the systolic blood pressure changes showed a significant linear correlation (P < 0.001). In study 2, the relation between the electric intensity and the SVmR amplitude showed a weak but significant correlation (P < 0.01) in the 1 MAC group. CONCLUSION: The evaluation of the SVmR provides useful information for determining the optimal anesthetic depth for laryngoscopy and intubation in individual patients.

Adult↗

Evaluation of tracheal intubation difficulty in patients with cervical spine immobilization: fiberoptic (WuScope) versus conventional laryngoscopy.

BACKGROUND: The WuScope is a rigid, fiberoptic laryngoscope designed to facilitate tracheal intubation without the need for head extension. The study evaluated the WuScope in anesthetized patients with neck immobilization. METHODS: Patients were randomized to one of two groups: those receiving fiberoptic laryngoscopy (WuScope, n = 43) and those receiving conventional laryngoscopy (Macintosh blade, n = 44). Manual in-line stablization of the cervical spine was done during intubation. Seven parameters of intubation difficulty were measured (providing an intubation difficulty scale score): number of operators, number of attempts, number of techniques, Cormack view, lifting force, laryngeal pressure, and vocal cord position. RESULTS: Successful intubation occurred in 95% of patients in the fiberoptic group and in 93% of patients in the conventional group. There were no differences in number of attempts. In the fiberoptic group, 79% of patients had an intubation difficulty scale score of 0, representing an ideal intubation: that is, one performed by the first operator on the first attempt using the first technique with full glottic visualization. Only 18% of patients in the conventional group had an intubation difficulty scale score of 0 (P < 0.001). More patients had Cormack grade 3 or 4 views with conventional than with fiberoptic laryngoscopy (39 vs. 2%, P < 0.001). Intubation times in patients with one attempt were slightly longer in the fiberoptic (median, 25th-75th percentiles: 30, 23-53 s) compared with the conventional group (24, 17-30 s, P < 0.05). Corresponding times in patients requiring > one attempt were 155 (range, 112-201) s and 141 (range, 95-186) s in the fiberoptic and conventional groups, respectively (P value not significant). CONCLUSIONS: Compared with conventional laryngoscopy, tracheal intubation using the fiberoptic laryngoscope was associated with lower intubation difficulty scale scores and better views of the laryngeal aperture in patients with cervical imnmobilization. However, there were no differences in success rates or number of intubation attempts.

Adult↗

Suspension laryngoscopy for endotracheal stenting.

OBJECTIVES/HYPOTHESIS: Airway stents have recently been used to establish and maintain patent airways in patients with malignant central airway obstruction, but insertion modalities remain controversial to date. The study seeks to determine the role of suspension laryngoscopy in interdisciplinary airway stenting. STUDY DESIGN: Retrospective, single-institution analysis of a case series treated by a multidisciplinary airway team. METHODS: Ninety-three consecutive patients with malignant obstruction of the trachea and/or tracheobronchial bifurcation underwent endotracheal stenting through a suspension laryngoscopy approach for the relief of impending respiratory distress. Feasibility, mortality, survival, and complications were analyzed as main outcome measures. RESULTS: Stenting through a suspension laryngoscopy approach was feasible 91 of 93 patients (97.8%). Fifteen patients needed repeated stenting, and in all, 121 stents were implanted during the observation period. This approach allowed for the repeated insertion of rigid bronchoscopes of graded sizes to establish an airway and for precise stent positioning. Optical instruments and stent introducer systems could easily be used while adequate ventilation was continuously maintained. Silicone stents of maximal size were inserted without injury of the vocal cords during intubation. Median survival for all patients was 8 months. No intraoperative airway complications were observed, and no patient died secondary to stenting. CONCLUSIONS: Suspension laryngoscopy and jet ventilation provide an ideal setting for the precise placement of tracheal and bifurcation airway stents. Laryngologists should actively participate in interdisciplinary airway stenting programs.

Airway Obstruction↗

Nifedipine prevents the pressor response to laryngoscopy and tracheal intubation in patients with coronary artery disease.

The efficacy of sublingual nifedipine, administered one minute before anaesthetic induction, in order to minimise the pressor response to laryngoscopy and tracheal intubation was studied in a group of 15 patients who underwent coronary artery bypass surgery. Another group of 15 similar patients served as control. Premedication consisted of oral diazepam 5-10 mg, intramuscular morphine 0.2 mg/kg and promethazine 0.4 mg/kg. Anaesthesia was induced with morphine 0.1-0.15 mg/kg and thiopentone 3-5 mg/kg. Laryngoscopy and tracheal intubation were facilitated with suxamethonium 1.5 mg/kg. A significant increase in blood pressure occurred during and after laryngoscopy and tracheal intubation in the control group. This increase was absent in the patients pretreated with nifedipine. The nifedipine group also maintained a lower rate-pressure-product than the control group during the period of study. It is concluded that nifedipine 10 mg is a useful pretreatment to prevent the pressor response to laryngoscopy and tracheal intubation in patients with coronary artery disease.

Adult↗

The effect of laryngoscopy of different cervical spine immobilisation techniques.

Fifty patients underwent laryngoscopy with two different cervical spine immobilisation techniques. First the cervical spine was immobilised in a rigid collar with tape across the forehead and sandbags on either side of the neck, then with an assistant providing manual in-line immobilisation. Finally, patients underwent laryngoscopy in the routine intubating position. In 56% of patients the view of the larynx improved by one grade and in 10% the view improved by two grades when manual immobilisation was substituted for the collar, tape and sandbags (p < 0.0001). There was a poor view on laryngoscopy (grade 3 or 4) in 64% of patients when immobilised in a collar, tape and sandbags compared to 22% of patients undergoing in-line manual immobilisation (p < 0.001). Mouth opening was significantly reduced when patients were wearing cervical collars and this was the main factor contributing to the increased difficulty of laryngoscopy in this particular form of cervical spine immobilisation. It is recommended that manual in-line immobilisation should be the method of choice for cervical spine stabilisation during tracheal intubation.

Cervical Vertebrae↗

Effect of cricoid pressure on the view at laryngoscopy.

The impact of cricoid pressure on laryngoscopy is unknown. We have developed a quantitative method of recording the laryngoscopic view using a rigid, zero-degree endoscope. We found that an image matching the laryngoscopist's view could be obtained by positioning the endoscope along the laryngoscopist's 'line of sight'. Photographing this image allowed us to measure laryngeal exposure. We set out to define the effect of cricoid pressure on laryngoscopy using this method. In 40 patients undergoing elective surgery, laryngoscopy was performed with cricoid pressures of 0-60 N, increasing by increments of 10 N. We photographed the laryngoscopic view at each force and recorded dynamic images as cricoid pressure was released. The change in laryngoscopic view with increasing cricoid pressure fell into one of four broad patterns: little change (11 subjects); gradual deterioration (10 subjects); improvement at low force (< 20 N) followed by deterioration (9 subjects); improvement at high force (> 30 N) (10 subjects). We identified five subjects with a good initial view (anteroposterior length of the rima glottidis > 5 mm) who showed a marked deterioration in laryngoscopic view as cricoid pressure increased; in three of these subjects this progressed to obscure the larynx completely at a force of 30 N, 40 N and 60 N, respectively. We conclude that the effect of cricoid pressure on laryngoscopy is complex. However, in some individuals, a force close to that currently recommended (30 N) may cause a complete loss of the glottic view.

Adult↗