PubMed HealthSearch

SEARCH · PubMed Health

Results for “Local Area Networks”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

[Computerized database system for pure tone audiometry].

The management and storage of pure tone audiometry data creates a major problem for otolaryngological clinics. We have devised a new computerized database system to overcome this problem. The hardware involved includes multiple audiometers and computers interfaced with a glassfiber local area network (Pi-Net). The software used is database 3 plus, a popular database language and utility software package. Programs were written for data entry, data transfer, reference, entry of patient ID, and evaluation of tympanoplasty. The following benefits of the system are noted. 1) Data entry is possible at every terminal (audiometer and computer). 2) Storage capacity is sufficient for more than 10 years of operation. 3) All data can be retrieved rapidly at any terminal. Evaluations of pre- and post-tympanoplasty hearing loss are facilitated by this system. This system is very effective for follow up of hearing disorders.

Audiometry, Pure-Tone

Effective staff communications in a large I.C.U.

A byproduct of the Quality Assurance process is the continual review of individual and group practice. The aim is to eliminate errors and to improve care. For managers and directors to know what issues are currently important to the staff members an upward channel of communication is also needed. In our SICU with over 120 staff there was no documentation of communication in either direction. Casual survey did not reveal a major problem - but the need to document the dissemination of information, particularly new policies - especially to satisfy accrediting agencies - led us to develop MEMOS, an electronic mail system for staff members within the local area network (LAN) in the SICU. The system will run on an individual PC. The network is used because of the physical configuration of the intensive care units. The system is used by nurse managers to keep staff members up to date. Features include: Easy file maintenance. Individual password access. A defined group of system operators with access to all system functions Limited access to all other users. As many as 40 definable sub-groups for the purposes of mail distribution. Easy operator tallying of those delinquent in reading their mail. Hard copy with distribution list for all memos added to system. Browse feature to allow re-reading of old memos. Feedback channel regularly read by system operators. This system has improved the level of staff awareness in the SICU and helped build morale.

Computer Systems

Platform independent implementation of DICOM-based miniPACS.

Platform independence is an important issue for a software designed to run across a hospital environment which is practically always heterogeneous one. This paper presents a simple miniPACS solution designed over an existing Intranet (Internet limited to a local area network). Platform independence is achieved with Java programming language which allows resulting code to be executed on virtually all machines. System consists of a server application providing DICOM (Digital Imaging and Communications in Medicine) services and clients that can use these services over a TCP/IP connection. The server application is capable of an image storage and supports a query mechanism to allow access to stored data, thus the clients may perform two major functions: providing image data for archiving or image retrieval for viewing. Presented client application provides both these functions. It retrieves stored images for further processing and returns calculated results to the archive. The parts of the system are connected through a DICOM interface. Consequently the system architecture is open and any devices like scanners or viewing stations supporting specific DICOM services may be attached.

Humans

Data interface between a radiology information system and a computed radiography system using a personal computer and standard software.

We describe the implementation of a simple data interface between a radiology information system and a computed radiography system that uses personal computers and standard software. The radiology information system was developed in house and runs in a local area network of personal computers. The computed radiography system is connected to a picture archiving and communication system. We have implemented a software data interface on a microcomputer, allowing automated transfer of patient data from the radiology information system program to the computed radiography scheduling program. The interface adds essential information used by the picture archiving and communication system to handle work lists, routing, and archiving algorithms. We have improved the user interface, shortened the scheduling time, enabled coherence of data bases, and eased the use of computed radiography and examination routing in the picture archiving and communication system. We have been using this interface for more than 1 year without difficulties. This custom solution addresses the problem of interconnecting existing equipment, avoiding proprietary restrictions or the lack of effective standards. This approach can be applied to any radiology environment that uses personal computers.

Humans

Evaluation of the medical diagnostic imaging support system based on 2 years of clinical experience.

The Medical Diagnostic Imaging Support (MDIS) system at Madigan Army Medical Center (MAMC) has been operational in a phased approach since March 1992. Since then, nearly all image acquisition has been digital with progressively increasing primary softcopy diagnosis used. More than 375,000 computed radiography (CR) images as well as other modality images have been archived. Considerable experience in installation and implementation phasing has been gained. The location and ergonomic aspects of equipment placement were refined with time. The original clinical scenario was insufficiently detailed and additions were made to facilitate smoother and more complete transition toward a filmless environment. The MDIS system effectiveness and performance have been good in terms of operational workload throughout, background operations, and reliability. The important areas regarding reliability are image acquisition, output, display, database operations, storage, and the local area network. Fail-safe strategies have been continually improved to maintain continuous clinical image availability during the times when the MDIS system or components malfunction. Many invaluable lessons have been learned for effective quality assurance in a hospital-wide picture archiving and communication system. These issues include training, operational quality control, practical aspects of CR image quality, and increased timeliness in the generation and distribution of radiographic reports. Clinical acceptability has been a continuous process as each phase has been implemented. Clinical physicians quickly used the workstations soon after the start of MDIS at MAMC. The major advantage for clinicians has been the amount of time saved when retrieving multimodality images for review. On the other hand, the radiologists have been slower in their acceptance of the workstation for routine use.(ABSTRACT TRUNCATED AT 250 WORDS)

Computers

The German teleradiology system MEDICUS: system description and experiences in a German field test.

MEDICUS is a teleradiology system which has been developed in a joint project of the German Cancer Research Center (Deutsches Krebsforschungszentrum) and the Transfer Center Medical Informatics (Steinbeis-Transferzentrum Medizinische Informatik) in Heidelberg, Germany. The system is designed to work on ISDN lines as well as in a local area network. Special attention has been given to the design of the user interface and data security, integrity, and authentication. The software is in use in 13 radiology departments in university clinics, small hospitals, private practices, and research institutes. More than 25 thousand images have been processed in 6 months. The system is in use in six different application scenarios. MEDICUS is running under the UNIX operating system. The connection of the modalities could in most cases not be realized with the DICOM protocol as older machines were not equipped with this standard protocol. Clinical experiences show that the MEDICUS system provides a very high degree of functionality. The system has an efficient and user friendly graphical user interface. The result of a comparison with other systems shows that MEDICUS is currently the best known teleradiology system. Cost reductions are already obvious, but additional research has to be performed in this field. An even more powerful commercial successor is currently under construction at the Steinbeis-Transferzentrum Medizinische Informatik in Heidelberg.

Ambulatory Care Facilities

PADS (Patient Archiving and Documentation System): a computerized patient record with educational aspects.

Rapid acquisition and analysis of information in an Intensive Care Unit (ICU) setting is essential, even more so the documentation of the decision making process which has vital consequences for the lives of ICU patients. We describe an Ethernet based local area network (LAN) with clinical workstations (Macintosh fx, ci). Our Patient Archiving and Documentation System (PADS) represents a computerized patient record presently used in a university hospitals' ICU. Taking full advantage of the Macintosh based graphical user interface (GUI) our system enables nurses and doctors to perform the following tasks: admission, medical history taking, physical examination, generation of problem lists and follow up notes, access to laboratory data and reports, semiautomatic generation of a discharge summary including full word processor capabilities. Furthermore, the system offers rapid, consistent and complete automatic encoding of diagnoses following the International Classification of Disease (ICD; WHO, [1]). For educational purposes the user can also view disease entities or complications related to the diagnoses she/he encoded. The system has links to other educational programs such as cardiac auscultation. A MEDLINE literature search through a CD-ROM based system can be performed without exiting the system; also, CD-ROM based medical textbooks can be accessed as well. Commercially available Macintosh programs can be integrated in the system without existing the main program thus enabling users to customize their working environment. Additional options include automatic background monitoring of users learning behavior, analyses and graphical display of numerous epidemiological and health care related problems. Furthermore, we are in the process of integrating sound and digital video in our system. This system represents one in a line of modular departmental models which will eventually be integrated to form a decentralized Hospital Information System (HIS).

Computer User Training

Benchmarking the perioperative process. I. Patient routing systems: a method for continual improvement of patient flow and resource utilization.

The article presents an overview of the design and application of a real-time patient routing system, based on barcode and local area network technology, that was designed to track the progress of patients during the perioperative process. We present data on all patients undergoing ambulatory surgery. Patients' progress during their surgical stay was recorded at 17 strategic events using this real-time patient tracking technology. These times were used to identify inefficiencies in the perioperative process by identifying bottlenecks and areas of high variation. We found that both raw and actual operating room (OR) utilization efficiency was less than 50%. Points of high variation in a patient's progress occurred during the time from admit to the hospital until the patient was ready for the OR; the time from when a patient was ready for the OR until they were called for; and the time a patient spends in the OR preoperative holding room. Causes for variation were identified and traced back to individual procedures, activities, and work processes. Multidisciplinary improvement teams were created to improve the pinpointed problem areas. The real-time patient routing system is a process that has proven to be highly valuable to all participants in the surgical process in bringing about rational, data driven efficiencies in perioperative services. This process has the potential to facilitate multidisciplinary cooperation in efforts to contain and reduce costs of perioperative services.

Appointments and Schedules

Prototype system for archiving and transmitting digitized radiographs.

A prototype system for archiving and transmitting digitized dental radiographs is described. The system uses a CCD video camera, IBM compatible personal computer with a frame-grabber and a high resolution VGA monitor. All archived images were compressed lossless by a factor of about 3. Digitized radiographs were archived together with their exposure data and assembled in an examination with a unique identifier and date of examination, together with the patient's history and reason for radiological examination. A radiological report with a list of differential diagnoses could be attached. Each examination could contain 50 digitized radiographs which could be converted to a tagged image file (TIFF) and printed halftone with a laser printer. Users of the system could receive examinations from the network-server and share the images in a local area network.

Humans

[Current network in Hokkaido University School of Medicine].

Recently campus LAN (Local Area Network) HINES (Hokkaido university Information NEtwork System) has been popularized rapidly in Hokkaido University. A lot of personal computers have been connected to HINES. Although many people in our school of medicine are coming to be familiar with the Internet, the network has not been utilized sufficiently yet. Establishment of efficient education and research with network, that is the essential purpose of HINES, is the problem to be solved in the near future. In this document, how to set up both modem and ISDN (Integrated Services Digital Network) is also referred for the help of access to HINES from outside of the campus.

Computer Communication Networks

[From a registry to a clinical information system. Development of the Datacor system at the surgery department A, Rikshospitalet].

Based on a simple register for thoracic and cardiovascular operations a modulated system has been built up at Department of Surgery A. The register covers waiting list, a basic patient record, extensive operative data, the postoperative course and the final outcome. A local area network includes 36 microcomputers with approximately 75 users. Owing to lack of commercially available programs, local applications based on dBase have been developed. In this article we discuss our positive experiences from use of the local system with respect to administration, quality assurance and local research, its future place within a larger hospital system interconnected via a backbone, the need for better support and graphic user interface.

Cardiac Surgical Procedures

A high-speed network for cardiac image review.

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning that the same software and hardware is used for a small local area network or for a large multi-institutional network. The system can handle uncompressed digital angiographic images, considered to be at the "high-end" of the bandwidth requirements. Along with the networking, a general-purpose multi-modality review station has been implemented without specialized hardware. This station can store a full injection sequence in "loop RAM" in a 512 x 512 format, then interpolate to 1024 x 1024 while displaying at 30 frames per second. The network and review stations connect to a central file server that uses a virtual file system to make a large high-speed RAID storage disk and associated off-line storage tapes and cartridges all appear as a single large file system to the software. In addition to supporting archival storage and review, the system can also digitize live video using high-speed Direct Memory Access (DMA) from the frame grabber to present uncompressed data to the network. Fully functional prototypes have provided the proof of concept, with full deployment in the institution planned as the next stage.

Cardiology

Simulation of patient flow in a picture archival and communications system network.

As hospital radiology departments expand their use of digitally formatted imaging devices, these machines will be connected in local area networks called Picture Archival and Communications Systems (PACS). The purpose of this paper is to demonstrate the use of computer simulation to analyze the process of patients using a PACS. The flexibility of using simulation on a proposed PACS is shown, starting with the description of a basic model. Different machine networks are run and the results compared. Simulation modeling provides a valuable tool to hospital and department administrators in detecting possible problem areas which may occur with proposed PACS configurations under assumed patient loads.

Computer Communication Networks

Wide-area network connecting a hospital drug informatics center with a university.

A wide-area network (WAN) connecting a new drug informatics center in a university-affiliated hospital with the university's campus-based computer network is described. In 1994 a pharmacy school developed a drug informatics center in an affiliated hospital. The center was originally designed around a local-area network (LAN) to be located at the hospital and planned to provide clients with easy access to typical productivity software and various electronic information resources. Only occasional modem connections to the university network were envisioned. However, large price increases in information retrieval systems and decreases in the cost of a frame relay connection (T1 line) to the campus network led to the installation of a WAN when the drug informatics center was established. Technical, political, and legal problems were overcome, and the connection was made. The WAN gave faculty and students at the hospital access to many of the university's computing and Internet resources. In addition, the faculty and students have access to various files and programs available only on the drug informatics center's file server at the affiliated hospital. It cost about $6500 to install all WAN equipment and maintain the frame relay for the first year, or a third of what would have been necessary for information retrieval software had a separate LAN been established at the hospital. A WAN connecting a drug informatics center and a university's computer network gave the center access to more electronic information resources at lower cost than would have been possible with a separate LAN.

Computer Communication Networks

Processing haematological data on a network environment.

A system for computerising full blood picture reporting developed in-house using dBASE IV on IBM-compatible microcomputers in a local area network environment is described. The software package has a user-friendly interface which consists of a horizontal main menu bar with associated pull-down submenus. The package captures data directly from an automatic blood cell counter and provides options to modify or delete records, search for records, print interim, final or cumulative reports, record differential counts with an emulator, facilitate house-keeping activities which include backing-up databases and repairing corrupted indices. The implementation of this system has helped to improve the efficiency of reporting full blood picture in the haematology laboratory.

Blood Cell Count

An audio-video system for automated data acquisition in the clinical environment. LOTAS Group.

OBJECTIVE: Our objective was to develop an audiovideo data acquisition system that facilitates studying the activities of anesthesia care providers in the clinical environment. METHOD: Ceiling-mounted miniature video cameras, vital sign monitors, and videocassette recorders (VCRs) were interfaced to digital computers in two patient admitting areas and two operating rooms of a trauma center. This video data acquisition system network (VASNET) is simple to operate. Insertion of a videotape activates the system and begins video overlay of updated vital signs onto the video image every 5 sec. Recorded data is passed via a local area network, allowing remote monitoring of the data acquisition process. To facilitate analysis of the video at a later time, the image, soundtrack, and vital signs data are stamped with the same time code. Each tape is initialized by recording the data file name and wall clock time for 30 sec at the start of taping. This initialization enables comparison of the video recordings with anesthesia, surgical, and nursing records. RESULTS: During 2 years of operation, VASNET was used to record over 100 cases of acute trauma management. Vital signs overlaid onto the video image identified when patient monitors were in use and providing data. Participants found videotape review useful in assessing their own performance. VASNET was nonintrusive and acquired data with minimum user interaction. In one operating room, separate from the trauma center, VASNET was installed to function as a remote monitor, with the option of videotaping. Although users were aware of when videotaping occurred, once patient management was underway, the activities of the anesthesia care providers did not appear to be influenced by the videocassette recording. Equipment maintenance was not excessive. The most frequent problems were changes to the VCR control settings and disconnection of the power supply or interface connections. CONCLUSIONS: Videotapes of the process of anesthetizing and resuscitating trauma patients provided a record of the activities of anesthesia care providers. Video vignettes may be useful training tools. Excerpts from real scenarios can be incorporated into anesthesia stimulators. The soundtrack and timing of real events from such video acquisition may be useful in the development of multimedia simulations of trauma patient resuscitation. The data collection may be useful for research into human performance, ergonomics, training techniques, quality assurance, and certification of anesthesia care providers in trauma patient management. Potential additional applications of VASNET include remote monitoring of patients in the operating room, in the intensive care unit, during transportation, in hazardous environments, and in the field. Such VASNET telemetry may facilitate the availability of expert opinions during medical and other consultations.

Anesthesia

Building a computer-supported quality improvement system in one year: the experience of a large state psychiatric hospital.

BACKGROUND: G. Pierce Wood Memorial Hospital, a large state psychiatric hospital, implemented a data-intensive quality improvement (QI) program as part of its efforts to attain Joint Commission accreditation. EARLY STEPS OF QI IMPLEMENTATION: With the December 1993 Joint Commission survey date in mind, the Executive QI Committee started weekly meetings in December 1992 to plan initiatives and establish a viable information management system for the QI process. A QI coach was hired to help plan all phases of the QI program, and a 40-hour training program on statistics and QI principles was provided to key middle managers. SOFTWARE CHOICE ISSUES: Software options can be examined in terms of data cleaning, data manipulation, statistical flexibility, graphics strength, word processor compatibility, and utility strength. SOFTWARE CONFIGURATION: The present configuration of our statistical software is relatively elaborate. Organizations new to using statistical software should start off modestly to avoid being overwhelmed by the infinite possibilities that large numbers of interlinked modules present. DATA NETWORK CONFIGURATION: The technical core of the computerized QI system and how it operates are discussed. The data interface between the local area network (LAN) and statistical system data is described in three stages: (1) the creation of the "system" file; (2) the generation of the raw data; and (3) the transference of the raw data into the system file. QI ACTIONS: A QI reporting form was developed on which each report user states his/her analysis of the monthly indicator data report and identifies root causes, describes the actions taken to resolve the problems, or evaluates the effectiveness of prior actions taken. In addition, each indicator manager presents a quarterly verbal report to the Executive QI Committee on QI occurrences in his/her area of responsibility. CASE STUDIES: A nursing department indicator revealed an insufficient amount of supplies being placed in the code-blue ambulance. Determination of root causes led to the identification of a breakdown in the process whereby each shift adds and reviews supplies. As another example, the initiation of the stat IM (use of intramuscular injections or tranquilizing medications to restrain persons) indicator report led to a decrease in the number of IMs ordered. CONCLUSIONS: If we could have developed this statistical software-based QI program in only one year, then virtually any organization, large or small, can attain the technical capability to conduct "state of the art" QI.

Data Interpretation, Statistical

[Networks for image communication. Current status].

Networks for the transport of digital images are key components of PACS systems. In order to create a platform for the selection of appropriate network technology, first the quantitative requirements for image data communication in a PACS system are analyzed. State-of-the-art local area networks as well as developments in progress are mentioned, and their performance is discussed with respect to the PACS requirements. Furthermore, the linkage of PACS systems and hospital or radiology information systems is discussed. Finally, a scenario is outlined for extra-mural applications of medical image communication.

Computer Communication Networks