PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MAGNETICS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Growth of human cultured cells exposed to a non-homogeneous static magnetic field generated by Sm-Co magnets.

A static magnetic field, with a strong spatial gradient, was established on the surface of cell culture dishes by use of a gilded iron needle set vertically above an Sm-Co magnet. The calculated magnetic flux density was more than 1.5 T at the center of the needle tip, and the products of the flux density and its gradient were about 200 and 60 T2/m at distances of 0.1 and 0.3 mm, respectively, from the center. The DNA content, DNA synthesis and labeling index of cultured cells located within 0.1 mm from the center of the needle, and the growth rate of cells located within 0.3 mm from the center, were measured. HeLa cells grew at a normal rate for 96 h in the magnetic field and showed no significant change in shape, detectable by scanning electron microscopy. The growth of HeLa cells was not influenced by exposure to the magnetic field. Similarly, exposure for 48 h to the magnetic field had no effect on growth of normal human gingival fibroblasts (Gin-1). The DNA content, assayed by microfluorometry of the nuclei of both types of cells stained by the Feulgen reaction, was not significantly different from that of controls. Moreover, exposure to the magnetic field had no effect on DNA synthesis or the labeling index of HeLa cells assayed by autoradiography of incorporated [3H]thymidine. It is concluded that a non-homogeneous magnetic field of the intensity and the gradient used in this study does not significantly influence the growth of HeLa cells or Gin-1 cells.

Cells, Cultured↗

Magnetic Marker Monitoring: An application of biomagnetic measurement instrumentation and principles for the determination of the gastrointestinal behavior of magnetically marked solid dosage forms.

Magnetic Marker Monitoring offers an alternative to investigate the behavior of solid dosage forms in the organs of the gastrointestinal tract without the need to apply radiation. For Magnetic Marker Monitoring, the dosage form is marked as a permanent magnetic dipole by the incorporation of small amounts of ferromagnetic material, as for example the colorant black iron oxide, and subsequent magnetization. Thereby, the dosage form is labeled as the source of a well defined magnetic field, which can be measured using a measurement technique that is established for biomagnetic investigations. Using the established concepts for magnetic source localization, the three dimensional localization and orientation as well as the strength of the magnetic source can be reconstructed from these magnetic measurement data as a function of time. Furthermore, it is possible to gain quantitative information on the disintegration of dosage forms in vivo. Examples are given for results obtained concerning the esophageal transit, the gastric and the intestinal behavior of capsules and tablets.

Capsules↗

Novel detection system for biomolecules using nano-sized bacterial magnetic particles and magnetic force microscopy.

A system for streptavidin detection using biotin conjugated to nano-sized bacterial magnetic particles (BMPs) has been developed. BMPs, isolated from magnetic bacteria, were used as magnetic markers for magnetic force microscopy (MFM) imaging. The magnetic signal was obtained from a single particle using MFM without application of an external magnetic field. The number of biotin conjugated BMPs (biotin-BMPs) bound to streptavidin immobilized on the glass slides increased with streptavidin concentrations up to 100 pg/ml. The minimum streptavidin detection limit using this technique is 1 pg/ml, which is 100 times more sensitive than a conventional fluorescent detection system. This is the first report using single domain nano-sized magnetic particles as magnetic markers for biosensing. This assay system can be used for immunoassay and DNA detection with high sensitivities.

Bacterial Proteins↗

Magnetic split-flow thin fractionation of magnetically susceptible particles.

We recently built a magnetic separation system to extend the applications of split-flow thin (SPLITT) fractionation to magnetically susceptible particles. Here, we characterize the magnetic SPLITT system using magnetically susceptible particles and ion-labeled particles. The flow axis of separation channel was orientated parallel and perpendicular to gravitational forces to exclude and include, respectively, gravitational effects on separation. Both operating modes were used to test the theory experimentally, with emphasis on the parallel mode. The magnetic susceptibilities of carrier and ion-labeled particles were varied, and various ion-labeled and unlabeled particles were studied experimentally, resulting in successful separation of labeled particles, yeasts, and cells from unlabeled ones. The minimal difference in magnetic susceptibility (delta(chi)) required for complete particle separation was about 1.75 x 10(-5) [cgs], corresponding to about 10(9) labeling ions per particle in this study. The throughput was around 7.2 x 10(8) particles/h using the present setup. Magnetic SPLITT fractionation shows good potential for use in obtaining particles magnetic susceptibilities from a simple theoretical treatment.

Ions↗

Acyclovir serum concentrations following peroral administration of magnetic depot tablets and the influence of extracorporal magnets to control gastrointestinal transit.

In the present investigations peroral acyclovir depot tablets with internal magnets were developed. An extracorporal magnet was used to prolong the gastric residence times of the dosage forms and to influence the duration of absorption of acyclovir. The magnetic depot tablets contained 200 mg acyclovir. In a three-way cross-over in vivo study with five healthy male subjects, the plasma concentration-time profiles of acyclovir were determined. The acyclovir plasma concentrations following peroral administration of magnetic depot tablets in the presence and absence of an extracorporal magnet were determined. A commercially available immediate release preparation was used as a reference preparation. In the presence of an extracorporal magnet which was placed in the stomach region, the plasma concentrations of acyclovir were significantly higher after 7, 8, 10 and 12 h (P<0.05, U-test, Wilcoxon, Mann-Whitney). The mean area under the plasma concentration-time-curve (AUC0-24h), in the presence of the extracorporal magnet was 2802.7 ngh/ml. Without the extracorporal magnet a mean AUC0-24h of 1598.8 ngh/ml was achieved. Computer simulations were carried out to show the influence of the gastric residence time of acyclovir depot preparations on the plasma concentration-time profiles of acyclovir.

Acyclovir↗

Safety of the magnetic field generated by a neuronal magnetic stimulator: evaluation of possible mutagenic effects.

OBJECTIVE: The possible mutagenicity of a magnetic stimulus was checked using the Ames test with Salmonella typhimurium TA98 and TA100 as tester strains. METHODS: Samples of these bacteria were exposed to a pulsed magnetic field, on the order of 1 T. The magnetic pulses were generated by a neuronal magnetic stimulator with a flat coil. The magnetic stimulus was a continuous sequence of slightly damped half sinusoids at a rate of 5 pulses/s. Exposure times were 2-5 and 15 min. Exposure position was such as to maximise the magnetic field and minimise the induced electric field. Room temperature was maintained at 28.5 +/- 0.5 degrees C and the temperature was measured inside the samples. RESULTS: None of the exposure conditions showed any increase in mutation in either of the two bacterial strains. CONCLUSIONS: These results are discussed in comparison with effects found in the literature. The magnetic stimulation used under the conditions of this study does not appear to have mutagenic effects. This does not apply to cases where both strong electric and magnetic fields are present.

Electric Stimulation↗

Self assembled magnetic PVP/PVA hydrogel microspheres; magnetic drug targeting of VX2 auricular tumours using pingyangmycin.

Chemotherapy in cancer treatment is associated with serious side effects and as a result there is great interest in research aimed at bringing down the level of systemic cytotoxicity. With advances in material science, magnetic drug targeting has emerged as one of the viable ways of attaining this. In this study, we used self assembled PVP/PVA magnetic hydrogel microspheres to deliver pingyangmycin (Bleomycin A5) to rabbit auricular VX2 tumours in the presence of a 0.5 T permanent magnet both during and 24 h after perfusion. A total of 22 New Zealand white rabbits ranging from 13 to 16 weeks and weighing 2.5-3.0 kg (2.46 +/- 0.2) successfully implanted with tumours 200-300 mm2 in size were used. In group D (1 mg pingyangmycin in 50 mg ferrofluid without a magnet) 2 weeks post treatment, there was statistically significant difference compared to the control (p = 0.05) in favor of group D. However, when compared to the group with 1 mg pingyangmycin(BLM) in 50 mg of ferrofluid and 0.5 mg (BLM) in 50 mg ferrofluid both with a permanent magnet in place for 24 h, the statistically significant difference was in favor of combined treatment, i.e. ferrofluid carrying drug in presence of a permanent magnet (p = 0.01). The microspheres in conjunction with the magnet did deliver pingyangmycin to the tumour and hence may be of use in future as far as magnetic drug targeting is concerned. However, more studies are still required to establish biodistribution and biostability not to forget drug release of ferrofluid of different chemotherapeutic agents available.

Animals↗

Magnetic navigation in AV nodal re-entrant tachycardia study: early results of ablation with one- and three-magnet catheters.

AIMS: Steering soft, flexible catheters using an external magnetic field could have advantages for heart catheterization, especially for therapy of tachyarrhythmias. Our aims were to assess the feasibility of magnetic navigation to Koch's triangle and reliable ablation of atrioventricular nodal re-entry tachycardia (AVNRT) with a magnetic catheter. METHODS AND RESULTS: Consecutive patients with AVNRT were mapped and ablated with a magnetically enabled catheter (Helios I or II), with, respectively, one and three magnets at the tip. The catheter was remotely advanced with the Cardiodrive system and orientated with the Navigant control system. After initial positioning with the external magnets, adjustment was made in 5 degrees steps. Success rates, procedure, and fluoroscopy times were analysed, and compared with a local contemporary series of conventional AVNRT ablations. Magnetic navigation was feasible in all 20 patients. Targets were easily reached. Catheters remained stable in position during accelerated junctional rhythms. Ablation was successful in 18/20 procedures (90%). No significant complications occurred. Median patient fluoroscopy time was 12 min, median physician fluoroscopy time was 4 min. Fluoroscopy times tended to be shorter than that in the conventionally treated group. Procedure duration decreased significantly over time, median procedure time was similar to that in the conventional group. CONCLUSION: AVNRT can be successfully mapped and ablated using magnetic navigation. A learning curve was evident, unrelated to catheter type, but to increasing operator experience. Physician radiation times were one-third of patient times. No complications occurred. Procedure time is comparable with that of conventional ablation.

Cardiac Catheterization↗

Magnetic properties of magnetically soft nanocomposite Co-SiO2 prepared via mechanical milling.

Nanocomposite of Co-SiO2, a soft magnetic material, with Co weight fraction x = 0.3 and 0.7 was prepared via mechanical milling. The magnetic properties of these samples, both zero-field-cooled (ZFC) and field-cooled (FC), have been measured as a function of x, milling time, and temperature. The structural assessment of the composite indicates a presence of only ferromagnetic (FM) hcp-Co phase in the composite. However, reported magnetic properties of these composites appear to be dependent on the presence of antiferromagnetic (AFM) phases of cobalt oxide as well. The observed enhancement in ZFC coercivity and a reduction in saturation magnetization with the milling time are due to an increase in defect density upon milling. The ZFC coercivity for the x = 0.3 samples has been found to be much higher than the x = 0.7 samples for all milling times. The coercivity above 50 K depends on temperature according to the law corresponding to isotropic uniaxial superparamagnetic particles. Below 50 K the presence of an AFM phase Co3O4 (TN approximately 33 K) and increased interparticle interactions bring in a departure from that law. The saturation magnetization is found to be temperature dependent for the x = 0.3 samples and temperature independent for the x = 0.7 samples, which further provides evidence of the presence of higher AFM phase fraction in the composite with a low metal volume fraction. The FC magnetic measurements show a presence of an exchange bias field and an enhanced coercivity which are higher than the ZFC measurements. All magnetic measurements indicate that the overall magnetic properties of the composite are dictated by the presence of a trace amount of cobalt oxides.

Cobalt↗

'Fixed-axis' magnetic orientation by an amphibian: non-shoreward-directed compass orientation, misdirected homing or positioning a magnetite-based map detector in a consistent alignment relative to the magnetic field?

Experiments were carried out to investigate the earlier prediction that prolonged exposure to long-wavelength (>500 nm) light would eliminate homing orientation by male Eastern red-spotted newts Notophthalmus viridescens. As in previous experiments, controls held in outdoor tanks under natural lighting conditions and tested in a visually uniform indoor arena under full-spectrum light were homeward oriented. As predicted, however, newts held under long-wavelength light and tested under either full-spectrum or long-wavelength light (>500 nm) failed to show consistent homeward orientation. The newts also did not orient with respect to the shore directions in the outdoor tanks in which they were held prior to testing. Unexpectedly, however, the newts exhibited bimodal orientation along a more-or-less 'fixed' north-northeast-south-southwest magnetic axis. The orientation exhibited by newts tested under full-spectrum light was indistinguishable from that of newts tested under long-wavelength light, although these two wavelength conditions have previously been shown to differentially affect both shoreward compass orientation and homing orientation. To investigate the possibility that the 'fixed-axis' response of the newts was mediated by a magnetoreception mechanism involving single-domain particles of magnetite, natural remanent magnetism (NRM) was measured from a subset of the newts. The distribution of NRM alignments with respect to the head-body axis of the newts was indistinguishable from random. Furthermore, there was no consistent relationship between the NRM of individual newts and their directional response in the overall sample. However, under full-spectrum, but not long-wavelength, light, the alignment of the NRM when the newts reached the 20 cm radius criterion circle in the indoor testing arena (estimated by adding the NRM alignment measured from each newt to its magnetic bearing) was non-randomly distributed. These findings are consistent with the earlier suggestion that homing newts use the light-dependent magnetic compass to align a magnetite-based 'map detector' when obtaining the precise measurements necessary to derive map information from the magnetic field. However, aligning the putative map detector does not explain the fixed-axis response of newts tested under long-wavelength light. Preliminary evidence suggests that, in the absence of reliable directional information from the magnetic compass (caused by the 90 degrees rotation of the response of the magnetic compass under long-wavelength light), newts may resort to a systematic sampling strategy to identify alignment(s) of the map detector that yields reliable magnetic field measurements.

Animals↗

Biomedical applications of magnetic fluids. i. Magnetic guidance of ferro-colloid-entrapped albumin microsphere for site specific drug delivery in vivo.

Magnetic guidance of magnetic albumin microsphere for site specific drug delivery was investigated in vivo. After intravenous injection in mice, magnetic microspheres localized in the site (lung) at which two permanent magnets were placed. Injection into the renal artery in rats also indicated that the microspheres were concentrated at the kidney by a magnetic field. When magnet was not applied, however, the microspheres were concentrated mainly in the liver. Such preferential localization by magnetic means suggested that magnetic albumin microspheres could become effective drug carriers with site specificity for the delivery of chemotherapeutic agents in cancer therapy.

Albumins↗

Removal of intralenticular magnetic foreign bodies with intraocular magnet.

PURPOSE: To investigate the possibility of conservation of the lens after removal of intralenticular magnetic foreign bodies with intraocular magnet. METHODS: Intralenticular magnetic foreign bodies of 15 patients were removed by using an intraocular magnet. The lens of each injury eye was conserved. Follow-up observation of these cases ranged from one to four years. RESULTS: The intralenticular magnetic foreign bodies of 15 patients were successfully removed. The lens of each injury eye was conserved and the transparence of the lens was properly maintained. Sizes of these foreign bodies were measured, ranging from 0.3 mm to 3 mm in diameter. The follow-up observation showed that the corrected visual acuity of 14 cases was not changed after operation. CONCLUSIONS: The intraocular magnet is very helpful for removal of magnetic foreign bodies from the transparent lens. This magnet allows removing of the foreign body by the surgeon and no damage to the lens was induced during the operation. Thus, maintenance of visual acuity of most of the patients can be achieved.

Accidents, Occupational↗

[Studies on magnetic responsiveness and renal embolization with magnetic microspheres in dogs].

The responsiveness and transcatheter embolization with magnetic gelatin microspheres (MG-ms) in dog kidney were reported. In experiments with magnet using a constant flow apparatus such as roller pump, the percent retention was determined by counting the carrier retained by the magnetic field and divided by the total starting counts. Factors influencing the percent retention of MG-ms include: velocity of medium flow, magnetic field intensity, alpha-Fe2O3 content in the MG-ms, viscosity of the medium and so on. Transcatheter embolization with MG-ms (10-30 microns) was performed under external magnet control in dog kidney. The result of angiogram and histological section showed that the MG-ms were in the arteries, arterioles, and glomerular capillaries with no adverse reactions. The embolized effect with magnet field was more prominent than the group without magnet field. These results show that the MG-ms is a promising embolic agent for treatment of renal cancer under external magnet control.

Animals↗

Metabolic changes after repetitive transcranial magnetic stimulation (rTMS) of the left prefrontal cortex: a sham-controlled proton magnetic resonance spectroscopy (1H MRS) study of healthy brain.

Rapid transcranial magnetic stimulation is being increasingly used in the treatment of psychiatric disorders, especially major depression. However, its mechanisms of action are still unclear. The aim of this study was to assess metabolic changes by proton magnetic resonance spectroscopy following high-frequency rapid transcranial magnetic stimulation (20 Hz), both immediately after a single session and 24 h after a series of five consecutive sessions. Twelve healthy volunteers were enrolled in a prospective single-blind, randomized study [sham (n = 5) vs. real (n = 7)]. Three brain regions were investigated (right, left dorsolateral prefrontal cortex, left anterior cingulate cortex). A single as well as a series of consecutive rapid transcranial magnetic stimulations affected cortical glutamate/glutamine levels. These effects were present not only close to the stimulation site (left dorsolateral prefrontal cortex), but also in remote (right dorsolateral prefrontal cortex, left cingulate cortex) brain regions. Remarkably, the observed changes in glutamate/glutamine levels were dependent on the pre-transcranial magnetic stimulation glutamate/glutamine concentration, i.e. the lower the pre-stimulation glutamate/glutamine level, the higher the glutamate/glutamine increase observed after short- or long-term stimulation (5 days). In general, the treatment was well tolerated and no serious side-effects were reported. Neither transient mood changes nor significant differences in the outcome of a series of neuropsychological test batteries after real or sham transcranial magnetic stimulation occurred in our experiment. In summary, these data indicate that rapid transcranial magnetic stimulation may act via stimulation of glutamatergic prefrontal neurons.

Adult↗

Crystal refinement and magnetic structure of KNi4(PO4)3: a novel example of three interacting magnetic sub-lattices.

KNi(4)(PO(4))(3) has been synthesised following a method previously reported by some of us and studied on the basis of magnetization and neutron powder diffraction (NPD) data. Magnetization measurements suggest the coexistence of ferromagnetic (FM) and antiferromagnetic (AFM) interactions: magnetization versus magnetic field curves present a remanent magnetization of around 2.15 micro(B) at T=2 K. The magnetic structure of the KNi(4)(PO(4))(3) has been determined at low temperature from the NPD data. These measurements show that there are three magnetic sub-lattices of Ni(2+) ions, which interact through common oxygen or phosphate groups, giving rise to FM and AFM couplings. The resulting interactions are FM in nature. Such a complex behaviour could provide an interesting model to analyse magnetic interactions in more condensed systems, such in mixed metal oxides.

Journal Article↗

Periodic structure of spicular magnetic clusters in a magnetic liquid.

The behavior of clusters formed by magnetic particles of magnetic liquid placed into a cylindrical capillary tube in magnetic field is described. Spicular clusters are formed from the sediment at the application of a magnetic field. They arrange themselves along the capillary repeating the direction of external magnetic field. Clusters distribute uniformly in the region of a magnetic field maximum. Such a state remains steady with respect to changes of the magnetic field gradient profile in definite limits. The structure of the uniformly ordered clusters is obtained experimentally. The capability of control of the structure period is shown. It is observed that increasing of magnetic field gradient up to the magnitude higher than a certain threshold value results in rearrangement of the clusters row into a multi-row hexagonal structure.

Journal Article↗

Destabilizing effect of time-dependent oblique magnetic field on magnetic fluids streaming in porous media.

The present work studies Kelvin-Helmholtz waves propagating between two magnetic fluids. The system is composed of two semi-infinite magnetic fluids streaming throughout porous media. The system is influenced by an oblique magnetic field. The solution of the linearized equations of motion under the boundary conditions leads to deriving the Mathieu equation governing the interfacial displacement and having complex coefficients. The stability criteria are discussed theoretically and numerically, from which stability diagrams are obtained. Regions of stability and instability are identified for the magnetic fields versus the wavenumber. It is found that the increase of the fluid density ratio, the fluid velocity ratio, the upper viscosity, and the lower porous permeability play a stabilizing role in the stability behavior in the presence of an oscillating vertical magnetic field or in the presence of an oscillating tangential magnetic field. The increase of the fluid viscosity plays a stabilizing role and can be used to retard the destabilizing influence for the vertical magnetic field. Dual roles are observed for the fluid velocity in the stability criteria. It is found that the field frequency plays against the constant part for the magnetic field.

Journal Article↗

Investigation of magnetic fluids by ultrasonic and magnetic methods

The influence of magnetic field on the acoustic and magnetic properties of magnetic liquids is discussed. By fitting the curve of Taketomi's theory to the experimental data of the anisotropy of ultrasonic attenuation, the values of quantities describing the structure of magnetic liquids have been determined. Moreover, the dependence of magnetic susceptibility on frequency has been measured. It shows that two processes of magnetization, based on the mechanisms proposed by Brown and Neel, contribute to the magnetization of the magnetic liquid.

Journal Article↗