PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MRI”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Field-focusing hyperthermia and magnetic resonance imaging (MRI) with a grounded probe and a commercial MRI scanner.

A method for performing magnetic resonance imaging (MRI) and producing field-focusing hyperthermia sequentially in phantoms and rat tissues with a grounded hyperthermic probe and a commercial MRI scanner was demonstrated. In the treatment mode the MRI scanner was used as a radiofrequency (RF) power source, and an invasive, electrically grounded, tuned probe was used to produce hyperthermia in phantoms via induced eddy current convergence. Temperature increases of 4.5 degrees C/5 minutes in a dielectrically uniform phantom and 5.0 degrees C/6 minutes in the peritoneum of a rat were measured in the vicinity (3-5 mm) of the grounded probe with the transmitter of the MRI scanner working at 2 per cent duty cycle. The advantage of this combined diagnostic and therapeutic approach is that the position of the hyperthermic probe can be monitored before each treatment, with observation of the tumor during and after treatment, if desired. In addition, the total cost is significantly less than that of both an MRI scanner and an RF hyperthermia treatment system.

Animals↗

[Tumor staging and follow-up care in rectosigmoid carcinoma: colonoscopic endosonography compared to CT, MRI and endorectal MRI].

BACKGROUND AND STUDY AIMS: Endosonography has become the best available method for local staging of primary rectal cancer and diagnosing recurrent local tumor. The aim of this prospective study is to compare the accuracy of endoscopic ultrasound (EUS), using an echo colonoscope (CF-UM 3, CF-UM 20, Olympus optical) to computed tomography (CT), body coil magnetic resonance imaging (MRI) and endorectal coil magnetic resonance imaging (EMRI). PATIENTS AND METHODS: From February 1991 to July 1993 90 patients with primary rectosigmoidal tumors (n = 32: 9 women, 23 men, mean age 68 years [range 37 to 84]) or follow-up examinations for recurrent local cancer (patients: n = 58, examinations: n = 93; 41 women, 52 men, mean age 61 years [range 31 to 84]) were investigated. The results of preoperative examinations were compared to histopathological findings regarding T and N stages. RESULTS: In T staging, accuracy of EUS (78%) was superior to CT (50%) and equivalent to both MRI (75%) and EMRI (80%). The accuracy of EUS (84%) in assessing transmural tumor infiltration was superior to CT, MRT and EMRT (50%, 75% and 80%, resp.); however, CT (77%) and MRI (86%) were more accurate than EUS (64%) and EMRI (33%) in assessing N stages. Recurrent local cancer was found in 22 patients. All but one were detected by EUS. Sensitivity, specificity and accuracy in follow-up examinations for recurrent disease for EUS were 95%, 94% and 95%, for CT 75%, 73% and 74%, for MRI 57%, 100% and 70%, and for EMRI 83%, 100% and 90% resp. CONCLUSIONS: Endoscopic ultrasound proved to be a safe and accurate method of preoperative staging and early diagnosis of recurrent rectal cancer and was superior or at least equivalent to CT, MRI and EMRI.

Adult↗

Differentiation between completely hyalinized uterine leiomyomas and ordinary leiomyomas: three-phase dynamic magnetic resonance imaging (MRI) vs. diffusion-weighted MRI with very small b-factors.

PURPOSE: To assess the possibility of differentiating between completely hyalinized leiomyomas and ordinary leiomyomas by using diffusion-weighted (DW) magnetic resonance imaging (MRI) (DWI) employing very small b-factors (b = 1.51 and 55.3 seconds/mm(2)) in comparison with three-phase dynamic MRI. MATERIALS AND METHODS: The subjects were 25 patients with 52 histopathologically confirmed uterine leiomyomas. All leiomyomas were divided into two histopathologic subtypes (5 completely hyalinized leiomyomas and 47 ordinary leiomyomas). For each leiomyoma, the enhancement index (EI) at three-phase dynamic MRI and apparent diffusion coefficient (ADC) were obtained and then compared. RESULTS: The EIs at second and third dynamic phases clearly differentiated the two types of leiomyomas without overlap of values. ADCs also clearly differentiated the two types of leiomyomas without overlap of values. Moreover, there were significant positive correlations between ADCs and EIs at all dynamic phases (r = 0.41-0.50, P < 0.01). CONCLUSION: Not only three-phase dynamic MRI but also DWI with very small b-factors could be useful for differentiating completely hyalinized leiomyomas from ordinary leiomyomas.

Adult↗

Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

In this methodological paper the authors report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system that is usable at the MR and the linear accelerator installations. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings (closed rings made of massive metal) led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties-nearly no distortion and high mechanical stability-are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be "corrected" (reducing displacements to the size of a pixel) by calculations based on modeling the distortion as a fourth-order two-dimensional polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms obtained by a maximum-intensity projection algorithm. As a result, information about the hemodynamics of the AVM was provided by a three-dimensional (3D) phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, the origin of the feeding arteries, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. The different imaging techniques of MR provide a sensitive, noninvasive, 3D method for defining target volume, critical structures, and for calculating dose distributions for radiosurgery of cerebral arteriovenous malformations, because dose calculation of radiosurgery at sufficient accuracy can be based on 3D MR data of the geometrical conformation of the patient's head.

Algorithms↗

[MRI of the small intestine with rapid MRI sequences in Crohn disease after enteroclysis with oral iron particles].

PURPOSE: To evaluate the efficacy of breathhold MRI following enteroclysis with addition of oral magnetic particles to study the extension, detection of stenoses and extraluminal manifestations in Crohn's disease. MATERIAL AND METHODS: 18 patients with Crohn's disease and potential of surgical intervention were studied with enteroclysis with addition of oral magnetic particles. T1-/T2-weighted breathhold MRI w/o spectral fat suppression w/o i.v. Gd-DTPA was applied. RESULTS: Typical findings were marked bowel wall thickening with strong contrast enhancement. 95.8% of affected small bowel segments and 94.7% of stenoses were correctly detected by MRI. All four fistulas were detected and important extraluminal findings were seen in 6/18 patients. Additionally, one ileoileal and two ileosigmoidal adhesions, two extraluminal abscesses and affection of the right ureter were delineated. CONCLUSION: MRI in Crohn's disease offers the potential to avoid radiation exposure in this relatively young patient group. Important additional findings relevant to indication of surgery are seen in approximately one third of cases. The replacement of transduodenal intubation by oral contrast application remains to be further studied.

Administration, Oral↗

[Fusion of MRI, fMRI and intraoperative MRI data. Methods and clinical significance exemplified by neurosurgical interventions].

The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion--requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions.

Adult↗

Truncus arteriosus communis in a midtrimester fetus: comparison of prenatal ultrasound and MRI with postmortem MRI and autopsy.

Different techniques are used in fetal cardiology, and their accuracy has been demonstrated on several occasions. Color Doppler US has proved to be a reliable and valuable tool in the diagnosis of fetal cardiac abnormalities. Magnetic resonance imaging (MRI) of the fetal heart has, so far, played no role in prenatal diagnostics. We report on a truncus arteriosus communis diagnosed prenatally during a screening ultrasound at 22 weeks of gestation. In addition to real-time ultrasound and color Doppler echocardiography, fetal MRI was performed. Fetal echocardiography arose suspicion of a type I common trunk. Fetal MR showed solely a widened vessel coursing retrocardially and additionally an inhomogeneous fluid distribution of the lung not shown on prenatal US. After termination of pregnancy at 23 weeks of gestation, MR fetography and autopsy were performed, and both found a type II common trunk. MR autopsy of the heart was very reliable in this case and could be an alternative when fetal pathology is not available for different reasons. Postmortem MRI was also able to demonstrate the inhomogeneous fluid distribution in the lung, which was confirmed by autopsy. Fetal and postmortem MR was reliable in the detection of an inhomogeneous fluid distribution in the lung not shown on prenatal US, providing a relevant additional finding to US. Therefore, MRI should be used more often in fetal cardiology, although it still must be further developed.

Abortion, Eugenic↗

MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system.

The purpose of this study was to test the hypothesis that when ultrasound (US) guidance is not feasible, abdominal biopsies can be performed safely and accurately under magnetic resonance imaging (MRI) guidance in a low-field environment. MRI-guided abdominal biopsy was performed on 31 consecutive patients, in whom US-guided abdominal biopsy was not possible because the lesion was not visualized in US (n=27) or an US-guided procedure was not considered safe (n=4). The locations of the lesions were liver (n=14), pancreas (n=6), lymph node (n=4), retroperitoneal mass (n=3), adrenal gland (n=3) and spleen (n=1). The average size of the lesion was 2.2 cm (range 1-4 cm) in maximum diameter. All procedures were done by using a 0.23-T open-configuration C-arm-shaped MRI scanner with interventional optical tracking equipment and software. Fine-needle aspiration (FNA) biopsy was performed on all 31 patients; 18 patients underwent both FNA biopsy and cutting needle core biopsy. Procedures were evaluated for diagnostic sensitivity, specificity and accuracy as well as procedure time and complications. The FNA biopsy specimens were adequate for interpretation in 27 (87%) of 31 cases. Two of these proved to be false-negative findings during follow-up or subsequent biopsy. The final diagnosis was malignant in 15 and benign in 16 patients. The sensitivity, specificity and accuracy of FNA biopsy were 71, 100 and 81%, respectively. Of the 18 core-needle biopsies, one was determined false-negative owing to nonrepresentativeness. The sensitivity, specificity and accuracy of histological samples were 90, 100 and 94%, respectively. The needle time was 19 min on average and the mean room time was 1 h 48 min. No immediate or late complications occurred. MRI-guided abdominal biopsy can be performed safely and accurately in a low-field environment in patients for whom an US-guided procedure is not feasible.

Abdomen↗

Open MRI-guided microsurgery of intracranial tumours. Preliminary experience using a vertical open MRI-scanner.

OBJECTIVES: A number of different image-guided surgical techniques have been developed during the past decade. None of these methods can provide the surgeon with information about the dynamic changes that occur intra-operatively. The development of open configurated MRI-scanners leads to new perspectives in the intra-operative management and resection control of intracranial tumours. MATERIAL AND METHOD: Using a vertical open 0.5 T MRI-scanner for intra-operative MR image guided neurosurgery, forty-four patients (20 female/24 male) with different intracranial tumours have been operated on since August 1997. The patients ranged in age from 20 to 70 years (mean +/- standard deviation = 47.2 +/- 15.9 ys). RESULTS: In 36 (82%) of 44 patients the tumours were completely removed with the aid of MR image-guidance. In 8 cases (18%) complete removal was not achieved. Postoperatively 6 (14%) of 44 patients developed neurological deficits which were transient in 5 cases (paresis, dysphasia). In these patients the tumours were located in or near eloquent brain areas (sensorimotor cortex/speech center). CONCLUSION: Intra-operative MRI is helpful for navigation as well as determining of tumour margins to achieve a complete and safe resection of intracranial lesions. Complications related to the surgical procedure are reduced and the risk of neurological deterioration due to tumour removal and postoperative complications is minimized. It can be concluded that the intra-operative application of interventional MRI technology may represent a major step foreward in the field of neurosurgery.

Adult↗

Comparison of voxel-based 3-D MRI analysis and subtraction ictal SPECT coregistered to MRI in focal epilepsy.

While voxel-based 3-D MRI analysis methods as well as assessment of subtracted ictal versus interictal perfusion studies (SISCOM) have proven their potential in the detection of lesions in focal epilepsy, a combined approach has not yet been reported. The present study investigates if individual automated voxel-based 3-D MRI analyses combined with SISCOM studies contribute to an enhanced detection of mesiotemporal epileptogenic foci. Seven consecutive patients with refractory complex partial epilepsy were prospectively evaluated by SISCOM and voxel-based 3-D MRI analysis. The functional perfusion maps and voxel-based statistical maps were coregistered in 3-D space. In five patients with temporal lobe epilepsy (TLE), the area of ictal hyperperfusion and corresponding structural abnormalities detected by 3-D MRI analysis were identified within the same temporal lobe. In two patients, additional structural and functional abnormalities were detected beyond the mesial temporal lobe. Five patients with TLE underwent epileptic surgery with favourable postoperative outcome (Engel class Ia and Ib) after 3-5 years of follow-up, while two patients remained on conservative treatment. In summary, multimodal assessment of structural abnormalities by voxel-based analysis and SISCOM may contribute to advanced observer-independent preoperative assessment of seizure origin.

Adult↗

MRI-clinical correlations in the primary progressive course of MS: new insights into the disease pathophysiology from the application of magnetization transfer, diffusion tensor, and functional MRI.

Despite patients with primary progressive multiple sclerosis (PPMS) experience a progressive disease course from onset, the burden and activity of lesions on conventional magnetic resonance imaging (MRI) scans of the brain are lower than in all other main clinical phenotypes of MS. This review outlines the major contributions given by magnetization transfer MRI, diffusion tensor MRI and functional MRI to the understanding of the pathophysiology of PPMS and provides evidence that, at least, three factors might explain this clinical/MRI discrepancy: (a) the presence of a diffuse tissue damage at a microscopic level; (b) a prevalent involvement of the cervical cord, and (c) an impairment of the adaptive capacity of the cortex to limit the functional consequences of subcortical structural damage.

Brain↗

Screening for cerebellopontine angle tumours: conventional MRI vs T2 fast spin echo MRI.

BACKGROUND: Unilateral audiovestibular symptoms are commonly seen in clinical practice and are rarely caused by retrocochlear pathology. However, clinicians are often required to rule out potentially serious causes of these unilateral symptoms. Gadolinium enhanced magnetic resonance imaging (GdMRI) is the most accurate test for detecting small cerebellopontine angle lesions and also screens the adjacent CNS structures. Its main disadvantage is the cost of the procedure. METHODS: We studied 100 consecutive patients with both GdMRI and a newer MRI screening study utilizing unenhanced T2-weighted fast spin echo (fse) MRI. Acquired images were randomly assessed by a panel of three neuro-radiologists. RESULTS: We found that the screening (fse) MRI was as sensitive and specific when detecting cerebellopontine angle tumors. CONCLUSIONS: We conclude that T2-weighted fse MRI is a safe and cost-effective alternative to GdMRI and offers better diagnostic utility when compared to auditory brain stem response (ABR) and CT scans.

Brain Stem↗

Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI.

OBJECTIVE: The purpose of this work was to evaluate the results from sodium and proton magnetic resonance imaging (MRI) in detecting small changes in proteoglycan (PG) content in bovine articular cartilage specimens. DESIGN: Articular cartilage from 15 specimens of bovine patellae were subjected to partial PG depletion with different concentrations of trypsin for 30 min. Sodium and proton MR images of the intact specimen were obtained on a 4T GE clinical MRI system. Two custom-built 7 cm-diameter solenoid coils tuned to proton and sodium frequencies were employed. Fast gradient echo and spin echo imaging sequences were used to determine sodium density, proton density and proton relaxation times (T(1)and T(2)) of the specimens. Spectrophotometric assay was performed after MRI to determine PG concentrations of the cartilage specimens. RESULTS: The sodium signal change correlated well with the observed PG loss (R(2)=0.85, P< 0.01) whereas the proton signal change was inconsistent (R(2)=0.10, P< 0.8). The change in proton T(1)and T(2)between the two regions did not correlate with PG loss (R(2)=0. 07 and R(2)=0.06, respectively). CONCLUSIONS: Results from these studies demonstrate that sodium MRI is both sensitive and specific in detecting small changes in PG concentration, whereas proton density and relaxation properties are not sensitive to small changes in PG content.

Animals↗

[Follow-up of scaphoid pseudarthroses and scaphoid fractures after Herbert screw implantation in the extremities--MRI (low-field MRI)].

From January 1993 to September 1996, 59 patients with a scaphoid nonunion (38 times mid/distal third, 21 times proximal third) and 21 patients with a scaphoid fracture (17 times mid/distal third, four proximal third) underwent surgery in our clinic. Fractures of the scaphoid were treated by Herbert screw fixation. The operative treatment of nonunions of the scaphoid included the transplantation of an iliac crest graft and Herbert screw fixation. In all cases, an MRI of the carpus in a low-field MRI was carried out pre-operatively in addition to standard X-ray examination. Post-operatively, all patients were again controlled by MRI within defined intervals. The signal intensities of the MRI in the fragments of the scaphoid were determined qualitatively and quantitatively by computer calculation, comparing the pre- and post-operative results with one another. It was possible to depict the entire scaphoid and to determine the signal intensities of the proximal and distal fragments after Herbert screw fixation due to reduced artefacts on T1-weighted images in all cases. 41 patients with scaphoid nonunion and five patients with a scaphoid fracture showed a pre-operative diminishing of the signal in the proximal fragment compared to the distal fragment. For these patients, the fusion rate was lower than in patients without pre-operative signal reduction.

Adolescent↗

Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI.

PURPOSE: To differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. MATERIAL AND METHODS: Tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. RESULTS: Axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm(3). In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420 % (p < 0.001) and 424 % (p < 0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. CONCLUSION: The results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model.

Animals↗

Spinal MRI in patients with suspected multiple sclerosis and negative brain MRI.

Although MRI detects the white matter lesions of multiple sclerosis within the brain with high sensitivity, a minority of patients have normal brain MRI. We describe 20 patients, selected from over 170 who had undergone brain imaging with minimal (n = 12) or no (n = 8) abnormalities (median number of lesions = I, range, 0-3) but in whom spinal MRI was abnormal. Twelve had clinically definite or laboratory supported definite multiple sclerosis according to the Poser criteria; one had clinically probable disease and seven, not fulfilling the Poser criteria, were classified as possible multiple sclerosis. All had presented with symptoms and signs referable to the spinal cord or optic nerves. Eleven had a primary progressive course, eight relapsing-remitting and only one secondary progressive. Moderate or severe disability was the rule in the primary progressive cases; all the relapsing-remitting patients had minimal disability. All had at least one lesion visible in the spinal cord (median 2; range 1-6). In patients in whom the diagnosis of multiple sclerosis is not supported by abnormalities on brain MRI, imaging of the spinal cord can be of considerable value.

Adult↗

Post-mortem high-resolution MRI of the spinal cord in multiple sclerosis: a correlative study with conventional MRI, histopathology and clinical phenotype.

We used high-resolution MRI to study the post-mortem appearance of spinal cord multiple sclerosis in relation to histopathology and low-resolution images. Fifty-nine 3 cm long formalin-fixed spinal cord specimens from 19 multiple sclerosis patients and three controls were studied. Clinical characteristics of each patient were reviewed. High-field MRI consisted of proton-density weighted spin-echo imaging with an in-plane resolution of 80 microm. Specimens were also imaged at 1.0 T, with 1 mm pixel resolution. After MRI, the specimens were cut at 5 mm intervals and stained for myelin (Luxol fast blue/cresyl violet) and axons (Bodian method). Two observers scored the MRIs for abnormalities and divided them into (i) well-delineated areas of high signal intensity (SI) and (ii) poorly defined areas of mildly increased SI. Abnormalities were scored semiquantitatively, white matter and grey matter separately. In 81 sections the total area of abnormalities per section was measured on both histopathology sections and on matched high-field MRIs. Abnormalities ranged from just a few abnormal areas to complete involvement of the spinal cord specimen. Patients with an aggressive disease course had more abnormalities than patients with a mild or intermediate disease course. Areas of mildly increased SI were seen in all specimens, and were often found around focal high-SI lesions. However, in six patients, areas of mildly increased SI were the predominant finding on the MRIs, correlating with a primary progressive disease course. Histopathologically, high-SI areas correlated with complete demyelination, while mildly increased SI corresponded with partial demyelination. All areas scored as abnormal by the neuropathologist were also found on the MRIs, and sizes measured using both methods correlated well (r = 0.85, P<0.01). On conventional MRIs, abnormalities could be recognized fairly well. However, better differentiation could be made between high-SI and mildly increased SI abnormalities on the 4.7 T images. In conclusion, high-resolution MRI revealed a great range of abnormalities in spinal cord multiple sclerosis, which related to disease course during life. Furthermore, we found very good correlation between the extent of abnormalities shown by histopathology and the SI changes on proton-density MRIs, mainly relating to demyelination revealed histopathologically.

Adult↗

Multiparametric MRI ISODATA ischemic lesion analysis: correlation with the clinical neurological deficit and single-parameter MRI techniques.

BACKGROUND AND PURPOSE: The purpose of this study was to show that the computer segmentation algorithm Iterative Self-Organizing Data Analysis Technique (ISODATA), which integrates multiple MRI parameters (diffusion-weighted imaging [DWI], T2-weighted imaging [T2WI], and T1-weighted imaging [T1WI]) into a single composite image, is capable of defining the ischemic lesion in a time-independent manner equally as well as the MRI techniques considered the best for each phase after stroke onset (ie, perfusion weighted imaging [PWI] and DWI for the acute phase and T2WI for the outcome phase). METHODS: We measured MRI parameters of PWI, DWI, T2WI, and T1WI from patients at the acute phase (<30 hours) and DWI, T2WI, and T1WI at the outcome phase (3 months) of ischemic stroke. The clinical neurological deficit was graded with the National Institutes of Health Stroke Scale (NIHSS). We compared the ISODATA lesion size with the PWI, DWI, and T2WI lesion sizes measured within the same slice at each phase. The lesion sizes were also correlated with NIHSS score of each phase. RESULTS: We included 11 patients; 9 (82%) were women, and 7 (64%) were black. The mean+/-SD age was 65.5+/-9.3 years (range, 45 to 82 years). The median NIHSS score was 15 (minimum, 4; maximum, 24)at the acute phase and 3 (minimum, 0; maximum, 22) at the outcome phase. The median time interval from stroke symptom onset to the acute MRI study was 10 hours (range, 6 to 29 hours), and the mean time interval to the outcome study was 93+/-11 days (range, 72 to 106 days). In the acute phase, the ISODATA lesion size had high correlation with the PWI lesion size (r=0.95; 95% CI, 0.89 to 0.98; P<0.0001), DWI lesion size (r=0.83; 95% CI, 0.66 to 0.92; P<0.0001), and T2WI lesion size (r=0.67; 95% CI, 0.39 to 0.84; P=0.008) and moderate correlation with NIHSS score (r=0.59; 95% CI, 0.02 to 0.88; P=0.06). In the outcome phase, the ISODATA lesion size had high correlation with the T2WI lesion size (r=0.97; 95% CI, 0.94 to 0.99; P<0.0001) and NIHSS score (r=0.78; 95% CI, 0.34 to 0.94; P=0.004). CONCLUSIONS: The integrated ISODATA method can identify and characterize the ischemic lesion independently of time elapsed since stroke onset. The ISODATA lesion size highly correlates with the PWI and DWI lesion size in the acute phase and with the T2WI lesion size in the outcome phase of ischemic stroke, as well as with the clinical neurological status of the patient.

Aged↗